The Tekran® Model 2600-NG Mercury Analyzer is designed for the analysis of gas phase sample cartridges. The system contains an atomic fluorescence detector, a dual stage thermal desorber and a data acquisition and control system. A single serial connection allows a Windows based PC to control the entire analysis process, acquire the detector output and calculate final results
Key Features
- Dedicated analyzer for manually exposed sampling cartridges.
- Sample path optimized for difficult matrices.
- Desorbs industry standard .25” OD x 5” to 6” long friction fit cartridges.
- Ultra sensitive Atomic Fluorescence (AF) detector.
- Dual stage gold preconcentrator/thermal desorber.
- Precision mass flowmeter gives superior long term stability.
- Auto carrier shutoff to conserve carrier gas
|
|
The MVI rapidly detects and continuously measures mercury
vapour. Revolutionary dual beam technology means the
instrument does not saturate or require regeneration
between readings as do traditional gold film detection
methods, ensuring instrument downtime is eliminated.
|
|
The Tekran Model 2537 Mercury Vapour Analyzer provides continuous analysis of total gaseous mercury (TGM) in air at sub-ng/m3 (parts per trillion (ppt) and parts per quadrillion (ppq)) levels.
The instrument samples air and traps mercury vapour into a cartridge containing an ultra-pure gold adsorbent. The amalgamated mercury is thermally desorbed and detected using Cold Vapour Atomic Fluorescence Spectrometry (CVAFS). A dual cartridge design allows alternate sampling and desorption, resulting in continuous measurement of the air stream.
Key Features
- Patented dual cartridge design.
- Capable of unattended operation for extended periods.
- High precision mass flow meter provides accurate measure of total sample volume.
- Ultraviolet excitation source is temperature controlled and features closed loop optical intensity control for optimum stability.
- Simple menu based operation allows modifications of all operational parameters to suit any monitoring application.
|
|
|
In addition to O2 and combustibles (CO + H2), the on-board methane detector provides extra safety during purge-down and light-off cycles of natural gas-fired boilers, furnaces and kilns. Analyzers are available with oxygen, combustibles and methane, or oxygen and methane only.
|
|
|
|
|
|
The Advance Optima process gas analyzers have a modular design that increases flexibility and saves money.
Analyzer modules can be combined into tailor-made solutions and upgraded to new features at any time.
Remote modules are easily attached and centrally operated.
One central unit and various analyzer modules
- with common controls
- with a common connection technology
- in a common system housing
All analyzers use high performance measurement technology and simplified calibration that doesn't require test gas bottles.
- Photometers
- In-Situ Laser Analyzer
- Oxygen Analyzers
- Trace Oxygen Analyzer ZO23
- Thermal Conductivity Analyzers
- FID Analyzers
read more...
The AO2000 analyzers provides Ethernet, TCP/IP interfaces. An OPC server is available. Profibus DP/PA and Modbus interfaces are available.
AO2000 system components are available with GOST-R certificates as with CSA approval for Class I Division 2 and ATEX approval for installation in Zone 1 or Zone 2.
For measuring flammable gases in hazardous locations the AO2000 series provides a safety concept with built-in purge control and alarm monitoring.
|
|
|
|
|
|
Gasmonitor Plus is just one of Crowcon’s control panel range. This flexible, rack based, microprocessor-controlled unit is used throughout the world, both onshore and offshore. Gasmonitor Plus provides the cost-effective solution to your system requirements.
Features:
Simple to Use
• All the day to day functions are available from the front panel
• The unique bar graph display per channel provides an instant representation of gas concentrations
• Common alarm LEDs on the display card mean that the whole rack status can be checked at a glance.
Flexible Architecture
• System is limitlessly expandable
• System customisation is achievable with minimal wiring
• Designed to industrial standards, Gasmonitor Plus will integrate fully with existing rack mounted protection systems on site
• Optional relay modules can be used to provide up to a total of 84 output relays per rack.
• Sixteen of these relays can be voted to activate from a combination of the three levels of alarm per channel
Other controllers in our fixed gas monitoring range include:
Vortex 1 to 12 channel control system
Gasmaster 1 to 4 channel control system
Gasflag Single channel control system
CellarSafe CO2 monitoring system
Ditech modular gas and fire detection and extinguishant control system
|
|
REGARD is a state-of-the-art microprocessor-driven, modular gas monitoring system.
Each card is fully configurable for all types of transmitters and gases, using the on-board push buttons. The gas concentration is displayed on a LED display and status LED’s allow a quick overview on the condition of the system.
|
|
|
MSA offers a complete range of safety related modular control systems, for all system sizes and applications, designed to process the input signals of gas detectors and other devices. In alarm conditions appropriate actions are triggered by the controller.
|
|
|
|
|
|
BW Technologies by Honeywell announces the arrival of the latest portable multi-gas solution – the GasAlertMax XT. Simultaneously monitoring for hydrogen sulfide (H2S) carbon monoxide (CO), oxygen (O2) and combustibles (%LEL), the GasAlertMax XT features a non-intrusive integrated sampling pump and SmartSample diaphragm pump technology. By offering one-button operation, the GasAlertMax XT provides ease of use and simple compliance to industry safety standards. Tamper-proof, user adjustable options enable the instrument to be customized to suit your specific application.
The GasAlertMax XT is ideally suited to a range of applications and customers including confined space entry, oil and gas, marine and shipping, utilities, wastewater treatment plants, power generation and municipal needs.
Powered by rechargeable batteries that provide enough power for an entire 13 hour shift, the compact GasAlertMax XT comes with standard event logging and datalogging. Calibration is simple with an automatic procedure. The GasAlertMax XT is compatible with the BW MicroDock II automatic test and calibration system. Multi-language support is available in English, French, German, Spanish and Portuguese.
For more information on the GasAlertMax XT, visit www.gasmonitors.com.
|
|
Compact Multi-gas Detector for H2S, CO, O2, Combustibles
The QRAE II is a full-featured, compact, one- to four-sensor gas detector for detection of combustibles, oxygen, hydrogen sulfide, and carbon monoxide. Key features include easy-to-change, externally accessed battery packs (available in rechargeable and alkaline versions), a water-resistant case and a new state-of-the-art O2 sensor technology with extended life.
Key features include:
Patented SPE O2? Oxygen sensor
Best EMI/RFI immunity technology for products in its class, eliminating radio interference
Easy access to sensors, filter and battery compartment without exposing electronic components to potential damage
Big graphic display for easy overview of gas type and concentration
Alkaline adapter and Lithium-ion battery pack
Rugged housing withstands harsh environments
|
|
|
FirstCheck is the very first multi-gas to combine complete VOC and toxic gas detection from 1 ppb up to 10,000 ppm with traditional multi-gas sensors for oxygen, hydrogen sulfied, carbon monoxide and explosive gas detection.
|
|
The MultiRAE Plus combines a PID (Photoionization Detector) with the standard four gases of a confined space monitor (O2, LEL, and two toxic gas sensors) in one compact monitor with sampling pump. The MultiRAE Plus gets the job done in more circumstances than any other gas detector. The MultiRAE Plus is quickly and easily changed from a sophisticated technician instrument to a simple text-only monitor. The same monitor can be used as a personal monitor, a hand-held sniffer, or as a continuous operational area monitor.
The MultiRAE Plus detector can be made wireless with the use of RAELink. This allows real-time monitoring information from the detector to be integrated into an existing AreaRAE system. A wireless, RF (radio frequency) modem allows detectors to communicate and transmit readings and other information on a real-time basis with a remotely located AreaRAE base controller up to two miles away.
This product has ATEX approval.
|
|
|
|
|
|
VA-3000/VS-3000 Multi-component Analyzer
Product Overview
From environmental monitoring to developing new energy sources and chemicals for the new era, gas analysis systems are faced with needs and challenges that have changed dramatically over time. Responding to these new needs, HORIBA has developed the VA-3000, the versatile gas analyzer that's ready for the future. A single analyzer is now capable of measuring a wider selection of gas components utilizing many different types of sensor technology. Non-dispersive infrared (NDIR) modules are available to measure gases such as CO, CO2, NO, N2O, CH4, SO2 and others. A chemiluminescent sensor module may be included to measure NO or NOx with a standard converter. And four different types of sensor modules are available to measure O2 - galvanic, paramagnetic, zirconium oxide or magnetopneumatic. Designed to be compact and lightweight, the VA-3000 may have up to three sensor modules installed in a single analyzer case. This unique feature means the VA-3000 can be used today for a broad range of applications including research and development or environmental pollution monitoring, where efficiency and space-saving are crucial.
|
|
FTIR, NDIR Infrared Gas Analysis Products
FTIR (Fourier Transform Infrared) and NDIR (Nondispersive Infrared) real-time and in-line gas analysis products from MKS are capable of ppb to ppm sensitivity for multiple gas species including NF3, NH3, H2, NO and N2O and gases with as much as 30% water.
|
|
SERVOPRO 1440 Gas Analyser
The 1440D provides a convenient solution for the measurement of one or two of the following gases: oxygen, carbon dioxide, carbon monoxide and methane.
- Excellent stability and performance
- Low maintenance
- No electrochemical cells to replace or renew
- Variants suitable for flammable / toxic sample gases
- 19” rack, panel mount or bench-top case options
- Concentration and low flow alarms
Technology Used
Oxygen – Servomex’ unique paramagnetic cell, which offers a fast, linear, accurate, highly stable and selective response in a non-depleting rugged package.
Carbon monoxide (CO), carbon dioxide (C02), Methane (CH4) – Single beam, single wavelength infrared technology, which gives a highly stable, selective measurement.
|
|
SERVOPRO 4100 Gas Analyser
The 4100 is designed to meet the process control and product qualification needs of industrial gas producers and users.
- Easy to set up and operate
- Low maintenance
- Extremely stable and reliable sensors
- Can measure up to four gases simultaneously
- External analogue input facilities
- RS232 / RS485 serial data output
- Modbus TM communications
|
|
ORBISPHERE 510 - Multi Channel O2, O3, CO2, N2 and H2 Gas Analyser
- Up to 3 sensors using electrochemical or thermal conductivity technologies reducing cost of installation and ownership
- High level accuracy, rapid response time and selective gas measurement gives reliable and effective process monitoring
- Thermal cut-off offers a longer life span for all ORBISPHERE sensors during CIP/abnormal high temperature conditions
- Cross-channel compensation that allows highly accurate dissolved gas readings whilst eliminating distortion from secondary gases (.....)
This analyzer offers multi channel capability for both electrochemical sensors measuring O2, O3 or H2 and for thermal conductivity sensors measuring CO2, N2, or H2 .It has been designed for process monitoring in liquid or gas phases across a wide range of applications for Beverage, Electronics Life Sciences and Power industries.
|
|
|
|
|
|
For the need to continuously and simultaneously measure the concentration of several gases in industrial and community applications, LumaSense offers different Multi-Gas monitors for detection in the ppm region.
The Photoacoustic Gas-Monitors 1412 and 1314 for:
- occupational health and safety measurements
- monitoring of anaesthetic gases in hospitals
- emission monitoring of exhaust from chemical processes
They can selectively measure the concentration of up to 5 component gases and water vapor in any air sample collected from points up to 50m away. Further, the instruments can compensate for interference between the measured gases, using the unique Cross-compensation feature. The 1412 is transportable and 1314 fits in a standard 19 inch rack.
The economical and versatile Multi Gas Monitor 1316 based on NDIR measurement technology can be used for gas analysis in a wide variety of industrial applications. The two models of 1316 are an excellent complement to the ultra-low detection ranges of photo-acoustic gas analyzers 1412 and 1314. They measure up to five gases, including Oxygen, and are configured from an assortment of available gas detection modules and sensors.
Gas Monitor 1316-1 for Industrial Combustion Monitoring and Control measures the concentration of Carbon monoxide, Carbon dioxide and Hydrocarbons (with reference to either Hexane or Propane). Combined with optional sensors it also can measure Oxygen and Nitric oxide.
Gas Monitor 1316-2 for Greenhouse Gas Monitoring, Refrigerant Leak Detection and other applications measures concentrations of Carbon dioxide, Ammonia and/or Freons. It can also be configured to measure Sulfur hexafluoride (SF6)
|
|
|
|
|
|
The premium multifunctional gas analyser MAPY 4.0 raises the bar in quality control regarding the connection between design, ergonomics and functionality and was awarded with the „red dot Award“ 2009 for outstanding product design.
The clearly arranged large touch screen provides optimal handling and easy visible information. MAPY 4.0 can be used for continuous monitoring of gas mixtures and for sample analysis via sample needle. Fast and highly accurate measurements, permanent system control and an automatic alarm signal when set limits are exceeded provide quality and safety in production processes. High-quality components and the robust easy-to clean stainless steel housing guarantee a long product lifetime and fulfill the high hygiene requirements for the food industry.
A multitude of connections (Ethernet, USB, Barcode-Reader) provide ease for communication. As an option the documentation software GAS CONTROL CENTER, an integrated printer, a barcode-reader are available, as well as a high pressure and a 19“ rack version of MAPY 4.0.
|
|
WITT’s MFA 6900 is a well established multigas analyser for measurements of up to ten different 2-component gas mixtures. It is the perfect unit for mobile analysis for on site service.
The measurement principle of thermal conductivity provides low maintenance, an unlimited life span of the sensor and a wide range of measurable gas mixtures. Easy handling and a robust housing make the MFA 6900 a practical gas analyser for numerous applications.
|
|
|
|
|
|
3 Gas - Landfill Gas Monitoring System (Wall Mount) - GIR5000
- For measuring oxygen, methane and carbon dioxide gas
- Alarms for all measurements and sample flow
- 4 to 20mA outputs for all measurements
- Optional safety alarm and shut-down system
The GIR5000 gas landfill monitoring system is a gas analyzer unit for measuring and monitoring the concentrations of oxygen and methane in landfill gas and biogas. As an option, the concentration of carbon dioxide can also be monitored. Used for:
- Landfill gas monitoring devices-methane
- Hazardous components in landfill gas
- Landfill safety
- Landfill gas monitor
- Landfill gas
- Landfill gases
- Landfill health effects
- Landfill pollution
Sample conditioning in the basic unit is provided by an external coalescing filter and water catch-pot assembly. When the external temperature is below 35°C (the internal temperature of the analyser) this technique is the most economic. For situations where the sample temperature at source is significantly higher than the ambient temperature, and the sample is saturated with water, an optional sample cooler can be fitted.
Analogue outputs and alarms are provided for all gases measured.
|
|
|
|
|
|
The Rapidox 3100B Oxygen and CO Analyser contains Cambridge Sensotec’s fast and accurate oxygen sensor complimented by an exceptionally stable and maintenance-free CO sensor.
The internal zirconia oxygen sensor gives high performance over its entire range of 100% oxygen down to 10 e-20 ppm. An internal pressure compensation system compensates for small changes in gas pressure to keep the readings especially stable. Calibration is quick and easy.
The CO sensor is based on infra-red silicon chip technology and its unique internal referencing means it requires no calibration or maintenance. A choice of CO ranges CO provides ultimate performance.
The Rapidox 3100B incorporates a powerful and near-silent linear piston pump for remote sampling of gas. Many features are fully programmable using the front panel keypad. Gas connections are made using 6/4mm flexible tubing and a flow gauge is provided to control the rate of gas flow.
The Rapidox has programmable alarms and outputs and is supplied with powerful Windows software for easy data-logging and graphing. Just switch on and start measuring.
- Bench mounted oxygen and carbon monoxide analyser with internal sensor and sample pump
- Rapid response long-life sensors
- Easy to calibrate using any two gases
- Fully programmable audible alarms with signal output
- Sample flow rate adjustable from 0 to 4 litres per minute
- Suitable for applications where the gas must be sampled remotely
- Gas is sampled through flexible tubing connected to the front of the analyser
- Perfect for analysis of room air and difficult to access locations
- Perfect for static gas applications
|
|
|
|
|
|
The Rapidox SF6 Multimeter performs a rapid analysis of the condition of SF6 by measuring the concentration of SF6, moisture and SF6 products in the gas. SF6 in air or nitrogen is continually sampled and a programmable alarm will trigger if the results are outside a programmable range. The Rapidox 3100C is ideal for monitoring the condition gas-insulated equipment and guarding against electrical breakdown.
The Rapidox SF6 Multimeter allows the sampled gas to be recycled and recovered, ensuring that no SF6 is released into the atmosphere. It is supplied with powerful Windows software for easy data-logging and graphing. Just switch on and start measuring...
- Ideal for controlling the SF6 quality in bus bars and circuit breakers
- Continuous gas sampling of SF6, SO2 and moisture
- Ideal for detecting the presence of leaks
- The Rapidox SF6 Multimeter is ideal for checking for the build-up of corrosive decomposition products
- High-precision catharometer for SF6 analysis over the range 0-100%
- Full-scale ceramic dew point sensor for moisture analysis -100°C to +20°C
- Input pressure 0.5 to 14 bar
- Windows data logging software with graphing
|
|
D-AGM Plus Series for biogas applications
NDIR-Dual Wavelenth Principle
OEM-Gastransmitter with improved characteristics
• Simultaneous measurement of CO2 and CH4
• No cross sensitivity to water steam and H2S
• Maximum long term stability due to high grade devices
on the PCB
• Fast response time
• Superior accuracy due to improved signal-to-noise-ratio
• USB and RS485 interface
• Linearized analogue output: 4...20mA / 0...8V
• Display for measurement range deviation: 2...22mA output
• Web based communication software
• Simple integration into analyzers and measurement systems
• Customizable to measure various combinations of gas
|
|
S-AGM Plus Series with NDIR-Dual Wavelenth Principle
For different gases, from ppm up to Vol.% ranges
OEM-Gastransmitter with improved characteristics
• NDIR-Dual wavelength sensor for gas measurement
• Low-grade drift characteristics
• Dual gas version or additional measurement range (D-AGM Plus)
• Fast response time
• Improved signal-to-noise ratio
• USB and RS485 interface
• Linearized analogue output: 4...20mA / 0...8V
• Display for measurement range deviation: 2...22mA output
• Temperature compensated
• Pressure compensated
• Web based communication software
• Simple integration into analyzers and measurement systems
|
|
AGM Series with NDIR-Dual Wavelength Principle
For different gases, from ppm up to Vol.% range
For CO,CO2,CH4,N2O,C3H8,C6H14 and other HC
OEM-Gastransmitter with improved characteristics
•NDIR-Dual wavelength sensor for gas measurement
•Proven and tested over 13 years
•Linearized analog output (current or voltage)
•Analog output signal with selectable time constant
•Separate output signal for 2 alarm thresholds
•RS 232 interface
•Zero and endpoint adjustable with potentiometers
•Temperature compensated
•Pressure compensation option
•European PCB format (160x100 mm)
|
|
S-AGM Plus Series with NDIR-Dual Wavelength Principle
For different gases, from ppm up to Vol.% range
For CO,CO2,CH4,N2O,C3H8,C6H14 and other HC
OEM-Gastransmitter with improved characteristics
• NDIR-Dual wavelength sensor for gas measurement
• Low-grade drift characteristics
• Dual gas version or additional measurement range (D-AGM Plus)
• Fast response time
• Improved signal-to-noise ratio
• USB and RS485 interface
• Linearized analogue output: 4...20mA / 0...8V
• Display for measurement range deviation: 2...22mA output
• Temperature compensated
• Pressure compensated
• Web based communication software
• Simple integration into analyzers and measurement systems
|
|
|
|
|
|
Its unique modular principle means that the system can be constructed individually. You can configure your multi EA 5000 to meet your needs, thus creating your personal analysis system. No problem if your analytical requirements change, the modular structure of the multi EA 5000 can be extended at any time.
The unique double furnace technology makes it quick to switch between vertical and horizontal applications in one instrument, i.e. fast and optimum adaptation to the sample matrix and analysis standard with minimal effort.
The flame sensor technology guarantees matrix-optimized, quantitative combustion. Even unknown samples, whose properties are undocumented, can be analyzed soot-free, precisely and reliably today.
Forget time-consuming method generation and optimization of process parameters, such as gas flow, temperature, dosing speed – these are in the past!
- Application diversity, analyzes solid, paste, fluid, gaseous and LPG samples
- Multi-element, with C, N, S and Cl determination in one instrument
- Multimatrix sampler, for fully automated determination of solid and fluid samples in vertical or horizontal furnace configuration
- Double furnace technology, optimal adaptation to the sample matrix – vertical and horizontal mode in a single instrument
- Extended measuring range with low maintenance, ultra-modern detectors, all the way from ppb to percent
- Modular design, freedom to select and extend your analysis system configuration
- Self Check System (SCS) for trouble-free operation
- Flame sensor technology for matrix-optimized sample digestion
|
|
TS-100V offer wide mesurement range from 0.02ppm to percent level in highest reliability by the contribution of Oxygen control combustion and unique optics.
The combination of the Ultra Violet Fluorescence method as a Sulfur detector and vertical furnace using Oxygen control combustion (patent pending) realize more defined trace Sulfur measurements for petroleum, petrochemical, fuel, biodiesels.
It can be upgraded to simultaneous Sulfur and Nitrogen analysis afterwards very easily.
Wide option are available for various application, autoliquid sampler, Gas&LPG injector, Trap&release unit, Nitrogen detector.
Model TS-100 Horizontal version also available for solid sample.
|
|
The Thermo Scientific TITAN 4000 is the ultimate Total Nitrogen,
Sulfur and Chlorine Analyzer, perfectly crafted for today’s
demanding laboratories. Powerful advances in technology deliver
brilliant results, with unprecedented sample throughput and
lowest cost of ownership.
• TN/TS analysis in less than 2 minutes
• Up to 60% reduction in bench space
• Consumable savings of at least 10% pa
• Future proof upgradeability
|
|
|
|