ADEV plans and produces probes for the analysis of oxygen to employ in the various industrial fields with problematic different applicative.
The range, based on sensors to zirconium oxide differs for temperature of employment, onerous length of immersion, background, applications and applications to low cost.
It is placed side by side to the extractive models, or to zirconium oxide that paramagnetic or electrochemical and allows the analysis of oxygen in the better solution, beginning from fractions than ppm in volume to 100%.
|
|
BULYSER 3 select
- Measurement of up to four gas components
- O -measurement: paramagnetic, electrochemical or/and ZrO
- IR-measuring cells (NDIR)
- Modular design, easy to maintain
- User-friendly touchscreen
- Graphical flow display
- Tested on the basis of EN 15267-3
- All relevant threshold and status alarms
- 4-20 mA output signal for each channel RS-232 interface
- Integrated pumps optional
- Pressure and temperature compensation optional
|
|
|
|
|
|
Binary Gas Analyzers
The 20 Series Gas Analyzer with thermal conductivity detector (TCD) is designed for non-continuous sampling and quantitative analysis of binary process streams of industrial gases and other gas mixing, cylinder identification, and atmospheric control applications.
The 50 Series Continuous Duty Gas Analyzer with thermal conductivity detector (TCD) is custom designed to your specific requirements. The analyzer contains a temperature regulated TCD which enables it to be used in continuous monitoring applications with minimum zero drift. Typical applications involve continuous monitoring of gas streams for low ppm impurity.
Both Analyzers:
- Optimized, Self-Contained Gas Flow System
- Built-in Gas Selection Manifold
- Custom Designed to Your Application
- Choice of standard, corrosion resistant or all stainless steel system
- Class 1, Div 1, Group B, C, D Class 1, Div 2, Group B, C, D available systems
We specialize in manufacturing custom engineered analyzers, therefore, we ask you to give us your specific application parameters in order to quote the appropriate analyzer for your needs.
|
|
|
|
|
|
Gasmet CR-series are desktop analyzers for high sensitivity, high speed gas analysis. The CR-series FTIR gas analyzers are especially suitable for vehicle exhaust measurements, catalytic research, gas purity tests and other research applications.
The liquid nitrogen cooled MCT - detector in the CR-series offers the lowest possible detection limits and shortest measurement times. Large selection of different sample cell path lengths (from 1.0 cm to 10 m) is also offered in order to suit different measurement needs. Gasmet Technologies can also supply customized sampling units to match different requirements.
There are three different CR - models available:
CR1000:
Gasmet™ CR1000 FTIR gas analyzer features a stainless steel single pass sample cell for highest measurement ranges (vol - %). Sample cell is heated (as standard 180 °C) in order to keep the sample in gas phase.
CR2000:
Gasmet™ CR2000 FTIR Gas Analyzer has a small volume sample cell which combined with the LN2 cooled detector makes it an excellent instrument for very fast measurements. Typical uses include vehicle exhaust measurements where short response times and high sensitivity are needed.
CR4000:
Gasmet™ CR4000 FTIR Gas Analyzer has a high-sensitivity sample cell and a LN2 cooled detector which give lowest possible detection limits. It´s therefore well suited for applications where very low levels of detection are needed.
|
|
|
|
|
|
Package Analyzer - Single pass headspace and liquid measurement - Flexible architecture
The ultimate tool for package analysis
The Package Analyzer is the ultimate tool for analysis of beer and soft drinks in glass bottles, PET containers and cans. The instrument is based on the popular MecSens piercer but its control, operation and data management are handled by a high performance touch screen PC. The ultra sophisticated miniature channel flow chamber allows accurate headspace analysis and is an example of MecSens engineering and its Swiss precision manufacturing capability.
The package incorporates two trace level oxygen sensors ingeniously connected to an ultra sophisticated miniature channel flow chamber for measuring headspace volume, temperature and the oxygen levels in headspace and the liquid. The Mecsens CO2 sensor allows the measurement of CO2 levels in liquid.
True TPO: No shaking of samples, no temperature preparation, no calculated values.
Client references proven technology.
|
|
|
|
|
|
U.S. EPA approved gas analyzers available with Ozone O3 analyzer, Carbon Monoxide CO analyzer, Oxides of Nitrogen NOX analyzer and Sulfur Dioxide SO2 analyzer.
The new Serinus series is the next generation of gas analyzers from Ecotech,
a leading manufacturer of environmental monitoring solutions. Completely
redesigned and incorporating innovative technology, the Serinus series will
deliver:
• Superior performance
• Low total cost of ownership
• Reduced maintenance intervals
Key features across the Serinus series include:
• Interchangeable components, consumables, spare parts and accessories, keeping operating and service costs low
• A low carbon footprint due to reduced power consumption and operation over a wider temperature range
• Use of zero volume fittings and flexible teflon tubing improves system integrity
• Redesigned electronics suite delivers greater stability and reliability
• Removable flash memory stores up to eight years of one minute data, including the ability to record up to 16 individual parameters, instrument settings and event logs
• Optional dual particulate filter can reduce scheduled on-site maintenance visits by up to 50%
• Intuitive Quick Menu and easier to read Graphical User Interface (GUI) simplifies instrument operation
• New advanced diagnostics protocol with detailed event tracking and convenient ‘Traffic Light’ analyzer state indicator
• Full remote control of instrument functions including calibrations, span/zero checks and diagnostics
|
|
The Andros 6500 offers unparalleled accuracy and performance exceeding its
predecessor, the Andros 6602, which has held the reputation as the highest performing system available for many years. Now taking advantage of the latest technology, Andros brings you a product with superior performance and reliability.
The Non-Dispersive InfraRed system (NDIR) measures gases, controls pneumatic components, communicates via RS-232 or USB with the host, and provides user-defined TTL outputs, as well as analog inputs and TTL Pulse Counter which can be integrated into the data output stream for user convenience.
|
|
|
|
|
|
RMT Ltd produces modular NDIR gas analyzer DX6100 Series. It is the second generation of gas analyzers after DX6000 model.
DX6100 gas analyzer is based on new integrated detector-emitter pair . The pair (optopair) is integrated into one housing with built-in thermoelectric cooling module. This solution provides high sensitivity, accuracy of operation.
Modular concept and universal solutions allow to supply analyzers for several gases: CO2, CH4, hydrocarbons.
- It is a cost-effective solution for application where accurate gas concentration measurements are required.
- Miniature design is suitable for field applications as well as for laboratory and indoor purposes.
- Friendly and and open for users architecture
- Two program levels for access: remote control through RS232C protocol using a developed set of external commands; RMT's analyst software for realtime operation is included into standard option.
- The instrument includes a basic datalogging function and continuous output facility to remote device (PC or indicator).
- The DX6100 is insensitive to partial non- transparency of measuring gas (smoke, etc).
- It operates well in wet conditions up to 100% of humidity
|
|
FTIR, NDIR Infrared Gas Analysis Products
FTIR (Fourier Transform Infrared) and NDIR (Nondispersive Infrared) real-time and in-line gas analysis products from MKS are capable of ppb to ppm sensitivity for multiple gas species including NF3, NH3, H2, NO and N2O and gases with as much as 30% water.
|
|
|
|
|
|
Gas density controllers
These operate mechanically. The density of the sample gas is compared via a bellows system with the gas density in a reference gas chamber. If the density of the sample gas alters, the bellows system actuates one or more micro switches. Gas density controllers function independent of any power supply.
Trafag gas density controllers are employed internationally in gas-insulated, high-voltage switchgear in power distribution networks. Their performance record is worldwide is unique. Even at climate-related temperature fluctuations of over 135°C, they provide precise measurement results and function reliably and maintenance-free. They are therefore to be found all around the world, in the ice-cold polar regions or under the blazing desert sun.
Gas density sensors
function electronically. The consistent resonant frequency of a quartz oscillator under vacuum is compared with the resonant frequency of an identical quartz situated in the sample gas. The difference in the resonant frequency is proportional to the density of the sample gas. This difference is processed into a digital or analogue output signal.
|
|
PerkinElmer recently acquired Arnel, a recognized leader in engineered solutions for GC applications in the hydrocarbon processing, food & beverage and industrial hygiene markets. PerkinElmer continues to provide standard and custom engineered solutions based upon the Clarus GC platform.
PerkinElmer offers more than 100 turnkey solutions with defined specifications that cover a wide range of applications and requirements in many industries – petroleum refining/petrochemical, natural gas and dissolved gases in transformer oils – providing superior analytical capabilities and ease-of-use.
And if our standard analyzers do not meet your needs, we can configure an analyzer to match your requirements.
|
|
With one of the most comprehensive families of sensors and on-line analyzers for pH, conductivity and dissolved oxygen, Yokogawa is recognized as a world leader in the field of analytical equipment.
|
|
Since 1984 B&B Thermo-Technik develop and manufacture successfully temperature probes.
New ideas were always a reason why B&B is one step further than its competitors. Our customers are the focus of our thinking and acting. For them we investigate, analize and realize almost everything in the temperature measurement.
B&B Thermo-Technik is specialized in the production of gas analysis probes. Just send us your inquiry and we will supply you with an detailed offer and the solution for your measuring problem.
You will find our range of standard sensors in our Online-Shop:
www.temperature-shop.eu
There you will also get more information about our range of temperature measuring technics:
- Temperature / Humidity Sensors
- Thermocouple Connectors
- Digital Thermomters
- Infrared Thermomters
- Stationary Pyrometers
- Controllers
- Indicators
- Data Loggers
- Hygrometers
- Transmitters
|
|
Conax Technologies retractable Sample Probe Assemblies are used to hot tap or inject into basically any type of liquid or gas stream. Typical applications of a sample probe are gas sampling, oil samplling, oxygen sampling, potable water sampling, waste water sampling, water quality sampling, and water or chemical injection.
Optional materials
Optional materials for the Sample Probe and the Conax Technologies Packing Gland body (wetted components) are available. Refer to the Conax Pressure and Vacuum Sealing Assemblies Catalog #5001C or our website for available options such as:
316L SST
316 NACE SST
316L CRN (gland body only)
Monel 405
Hastelloy C276
Inconel 600
Temperature and Pressure Ratings
Refer to the Conax Technologies Pressure and Vacuum Sealing Assemblies Catalog #5001C for temperature and pressure ratings for static conditions. Pressure ratings are reduced when the sealing gland cap is loosened to allow for the insertion or extraction of the Sample Probe.
|
|
|
The Clif Mock sample probe was the first truly isokinetic sampler available for crude oil sampling and is still the most accurate and reliable method for extracting a sample from a pipeline for BS & W analysis. Designed to be used with C-22 Isokinetic Samplers, the CD20 drive units are available in four configurations and are capable of pulse counting, timing, pacing from computer and sending out a "loss-of-signal" alarm. In the last few years, there has been increasing demand for much more elaborate systems. These CLIF MOCK True Cut systems commonly have multiple receptacles for separate products or batching operations and have controllers, which interface with central computer systems.
|
|
The analyser 2008 IR P is dependable and competitive, it is used to measure CO2 punctually (either CO or CH4) in all your techniques.
This portable analyser inserts a pomp of prélevement as well as a filter of porosity 0.1µm optional
|
|
KIMO, French manufacturer of measuring instruments, designed and developed AQ200 for CO/CO2, hygrometry, temperature and pressure control.
Key features of AQ200 :
- easy and friendly use: large display, browsing joystick
- multi-probe innovating system: can be used with 3 probes :
- CO / temperature: from 0 to 1,000 ppm and from -20 to +80°C
- CO2 / temperature: from 0 to 5,000 ppm and from -20 to +80°C
- CO2 / temperature / hygrometry: from 0 to 5,000 ppm, from -20 to +80°C, from 5 to 95%RH
- 3 interchangeable measuring modules: individually calibrated and automatically recognized by the instrument :
- 1 climatic conditions module (hygrometry, air pressure and temperature)
- 1 thermocouple temperature module (4 channels)
- 1 current / voltage module
AQ200 can measure and store up to 8,000 values, which can be saved on your PC, via wireless communication system.
|
|
|
|
|
|
The Vaisala CARBOCAP® Hand-held Carbon Dioxide Meter GM70 is available with a sampling pump. The GM70 with the pump-aspiration option is ideal for validating the calibration of incubators and environmental chambers.
To prevent condensation from occurring when drawing a gas sample from an environment with high humidity and temperatures into ambient air, an option called Nafionä tubing is available. The tubing prevents condensation in the gas sample by selectively removing the water vapor without affecting the level of CO2.
The GM70 incorporates the Vaisala CARBOCAP® Sensor, which is a silicon-based NDIR sensor that provides excellent reliability and long-term stability. Features include ten measurement ranges between 0…20% CO2 and a two year recommended calibration interval.
The GM70 has a multilingual user interface and a graphical LCD display. Data can be logged up to 30 days. The optional Windows® software provides an easy-to-use interface to a PC. Probes for measuring relative humidity, temperature and dewpoint temperature can also be connected to the GM70. A carrying case incorporates all the equipment and keeps the setup ready for immediate measurement.
|
|
Features
- Easy to use hand held 4 or 5 gas analyser
- Declaration of conformity to OIML R99 Class 1
- Certificate of calibration supplied Ideal for emissions diagnostics, tuning and regulated testing
- Measures CO, HC, O2 , CO2 , and Lambda (or AFR)
- Easily upgradeable to NOx or can be ordered as 5 gas analyser AUTO5-1
- Fast warm up time and fast response time with higher output pump
- Internal rechargeable battery; can be charge from AC or vehicle's own 12v supply
- RPM and oil temperature measurements plus accessories
- Prints via optional Infra-red printer
- PC compatible via RS232 for uploading stored data to PC for spreadsheet or graphical analysis and printing
- Complete with protective rubber sleeve, water trap and filter, lap-top style carry case, mains adapter/battery charger, 12v adapter cable, high temperature probe, RPM clamp, oil probe and manual
|
|
Besides the range of the portable ones from process, line FP is studied purposely according to problematic regarding the alimentary field. It concurs to obtain extremely precise analyzes sampling quantitative minimums (2 cc) extracts from confection beginning from containing modified atmospheres.
The analyzers in fact are equipped from a special syringe for the analysis spot that he captures alone quantitative of gas wished.
For he blots some to them confezionatrici are also available bread-boards that realize the analysis in continuous and to spot.
|
|
|
|
|
|
Modified Atmosphere Analyser (Portable) - MAPtest 800
- Rapid response time
- Low maintenance and calibration requirements
- Timed pumped sample
- Up to thirty hours running time between battery charges
- MAP/CAP (modified and controlled atmosphere packaging) techniques
The MAPtest 800 portable modified atmosphere packaging analyser has been designed specifically for measuring oxygen concentrations over a wide range of food packaging and storage atmospheres. Based on a galvanic cell sensor which is unaffected by the presence of carbon dioxide, the unit offers a high degree of accuracy across the range 0 to 100%, and can be calibrated easily on air.
Applications:
- Modified atmosphere packaging companies
- Modified atmosphere packaging tester
- Modified atmosphere packaging
- Gas ratio for modified atmosphere packaging
- Modified atmosphere sterilized packaging
- modified atmosphere sandwich packaging
- modified atmosphere packaging investment
- modified atmosphere carbon monoxide packaging
A sample probe or a syringe, both of which are supplied with the analyser, is used to introduce the sample. When the probe is used an in-built pump, activated from the front panel, draws the sample through the probe into the analyser. The pumped volume is adjustable allowing measurements from different pack sizes. Once a measurement is made the result is shown and held on a large 3½ digit display.
|
|
CheckPoint - for testing modified atmosphere packaging (MAP). Small ergonomically designed handheld analyser for oxygen and carbon dioxide quality control of modified atmosphere packages.
Battery operated with either standard AA batteries or a rechagable battery pack. Memory function, large easy readable display and a sturdy aluminium housing.
CheckPoint is available in two versions:
- CheckPoint O2 for oxygen only
- CheckPoint O2/CO2 for combined measuring of oxygen & carbon dioxide
Benefits of the PBI-Dansensor CheckPoint:
- Simple to use
- Ergonomical design
- Easy gas content indication for modified atmosphere packages
- Cordless and easy to transport
- CO2 measurement is temperature compensated
- O2/CO2 model compensates oxygen reading for carbon dioxide content in applications with high CO2 content
|
|
|
|
|
|
Portable oxygen Instrument for liquid and gas phase measurements
High quality analyzer for industrial use.
The MecSens series 512 hand-held analyzers are designed for off-line and in-line oxygen measurements in very harsh conditions. They fulfill all requirements for on-the-spot measurement in the beverage, power, water, semiconductor and chemical industries.
This high quality portable instruments with logging capabilities display both oxygen concentrations in either dissolved or gaseous units from trace levels to saturation and the temperature of the sample.
Ready to operate anywhere and anytime in the plant
These portable analyzers continuously measure temperature and oxygen concentration. They are compatible with all sensors in the 61 series. Exceptionally versatile, the customer can easily use the device as a log for automatically or manually storing measurement data with date and time. Featuring menu-driven user friendly operation, these analyzers can be easily configured using function keys and are built with the latest state-of-the-art technology.
|
|
|
|
|
|
Specifications:
Sensor: Mini Zirconia Oxygen Sensor with Integral Heater
Measurement Range: 0-1,000PPM Oxygen (over-range to 1500PPM)
Sample Method: Pump Drive with sample flow meter (includes internal mounted bypass check valve)
Display: 0.75” LED digital display,
Resolution: XXXX.X Color coded LEDs for system status: Alarms 1&2=RED, System Fault=YELLOW, System OK & on-line=Green
Response Time: <15 sec. for 90% response due to step change in PPM Oxygen @ 1 SCFH flow
Accuracy: ±3PPM @ 0-50PPM Oxygen (±1ppm with 2nd point cal near measurement point) ±5PPM at 51 500PPM Oxygen ±10PPM at 501-1,000PPM Oxygen
Operating Temperature: 32º-113º F (0º-45º C)
Signal Interface:
Serial service port: Bi-directional RS-232 Computer Communications of the following: Oxygen Concentration, Alarm Settings/Status, Fault Status
Analog Outputs: Voltage 0-1VDC or 0-5VDC or 0-10VDC +/- 0.5% @ 1K input min.
Non-isolated: 4-20mA: +/- 0.5%, negative ground (loop is powered by analyzer) Maximum loop impedance 500Ω.
Sample Port: 1/8 inch compression tube fitting (1/8” tubing assembly included)
Warm-Up Time: Approximately 2 min. to reach thermal equilibrium with ambient temperature.
Power: 9-250VAC, 50/60 Hz, Single Phase 10W
Power Electrical Connections: 2 meter power cable, ON/OFF Switch
Storage Temperature: 15º to 50º C (5-122º F)
Humidity: 0-95% non-condensing
Sample Flow: 1.0 to 2.0 SCFH @ constant pressure
Warranty: Analyzer & sensor: 12 mo. from date of shipment under normal operation
Weight: Less than 5 lb.
Mechanical: Aluminum chassis with carrying handle on top and rubber feet
|
|
|
|
|
|
Gas Analysers
WITT analysers are available as stationary or portable units for different types of gases and areas of application. Depending on type of application, they can be supplied separately or integrated with mixing systems. For local or remote monitoring and control extensive sensor technology and electronics are available. WITT are happy to design and build equipment to meet special requirements.
OXYBABY® 6.0 for 02 or 02/C02
Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate sample tests at the packaging machine, in stores or in laboratories.
OXYBABY® a cost effective mobile alternative to tabietop / fixed analysers for welding and food technology.
Ensure that the quality of packaged product is maintained (HACCP), guaranteed continued customer satisfaction.
The ideal instrument for sample tests with a minimum sample gas requirement, allowing the smallest of modified atmosphere packages (MAP) to be tested.
|
|
Features the sensitivity of larger instruments and easy handheld operation. Counts two sizes of particles; the second size is user-selectable. Configure sample times from one second up to 24 hours. Automatic shutoff when the battery charge drops below a safe operating level to maintain power to preserve data.
-0.3 micron sensitivity (227B) or a 0.5 micron sensitivity (227A)
-Counts two sizes of particles
-Compatible with PortAll Version 2 software
|
|
|
|
|
|
AEROTRAK™ HANDHELD PARTICLE COUNTER
The TSI AEROTRAK™ 9303 Handheld Particle Counter offers the most features and flexibility for customers interested in low cost and versatile handheld particle contamination monitoring. The 9303 features a sturdy and yet lightweight high-impact injection-molded plastic design for easy handling. The instrument is easy to configure using an intuitive keypad. The internal memory can store up to 1,500 sample records of particle count data which can be conveniently viewed on screen or downloaded using a USB port.
Features and Benefits:
- Size range 0.3 - 10 μm
- 0.1 CFM (2.83 LPM) flow rate
- Up to 3 channels of simultaneous data
I- SO 21501 compliant
- USB serial output
- 1,500 sample record storage
- 999 location labels
- Large 3.6-inch display
- On screen data review
- User selectable middle size channel
- Removable Li-ion battery
- Internal audible alarm
- Intuitive keypad menus
- High impact injection molded plastic
- Lightweight - only weighs 1.3 lbs (0.58 kg)
Applications:
- Particle contamination monitoring
|
|
|
|
|
|
P-TRAK® ULTRAFINE PARTICLE COUNTER
The TSI's P-TRAK® Ultrafine Particle Counter (UPC) - Model 8525 is a totally new approach to eliminating IAQ problems. This portable instrument detects and counts ultrafine or nanoparticles (smaller than 1 micrometer in aerodynamic diameter) that often accompany or signal the presence of a pollutant that is the root cause of complaints. It is now being used to track down some of the most difficult IAQ problems imaginable.
The P-TRAK UPC locates obvious pollutant sources such as boilers, furnaces, vehicles and also detects the not-so-obvious sources such as photocopy machines and printers. Use this instrument to detect the migration of toxic exhaust gases, malfunctioning office equipment, pinhole gasket leaks in boilers and a wide variety of other problems.
Features and Benefits:
- Real-time ultrafine particle counter
- Solves tough IAQ problems
- Easy to use
- Data log information
Applications:
- Check office equipment
- Clean room containment checks
- Filter checks
- Check fume hoods
- Check safety cabinets
- Vehicle emission migration
- Combustion leaks
- Control smoking areas
|
|
PC 2400 PS Portable Sampler
The PC 2400 PS Particle Counter provides the user unequaled flexibility. The instrument operates as a Grab-Sampler for analysis of individual samples, and in continuous, On-Line mode for real time process monitoring. Windows based software provides instrument configuration, data acquisition, and reporting capabilities to meet the user's specific needs.
BENEFITS/FEATURES
- Laboratory or On-Line use
- Fully portable with carrying case
- Low maintenance sample cell
- User adjustable size ranges
- Automatic sample purge
- Up to 16 size ranges
- Easy to use Windows based software
|
|
|
Kanomax handheld particle counters are designed for cleanroom certifications. The Model 3886 measures 5 particle sizes simultaneously with optional multi-functions, such as air velocity, temperature, and humidity. Its low air velocity measuring function is suitable for laminar flow units.
|
|
|
|