Sensor Features
- Reliable solid state metal oxide technology
- Rugged, long lasting sensor
- Large dynamic range
- Tolerates a wide range of temperature,
pressure and humidity levels
- Low cost
|
|
Figaro Engineering Inc. specializes in the research, development, manufacturing and marketing company of gas sensors and gas detection equipment.
In 1968, Figaro Engineering Inc. became the first company in the world to develop and commercialize semiconductor gas sensors. Globally, major concerns in the fields of gas detection, air quality control, HVAC appliances, and the automotive industry have relied on Figaro Engineering Inc. for gas sensing products.
Based on its extensive and broad-based experience in developing and manufacturing gas sensors, Figaro continues to expand its expertise into new areas of gas detection.
|
|
The Alphasense patented carbon dioxide sensor is a world first in CO2 monitoring:
Requires no power
Operates at room temperature
One sensor measures from 500ppm to 95% CO2
Small size
Low cost
Simple interfacing
Using the potentiometric measuring principle with our patented silver halide solid state electrolyte, this sensor does not have the high power requirement or high price tag of NDIR technology. This sensor is ideal where low cost and low power are critical for CO2 measurement.
This sensor is the result of seven years of research and development, and this work continues. While not as accurate as NDIR, and not suitable for IAQ measurements, this sensor is ideal for safety alarms, combustion gas monitoring and high CO2 process monitoring.
Contact us with your application. Evaluation boards are available.
|
|
ADEV plans and produces probes for the analysis of oxygen to employ in the various industrial fields with problematic different applicative.
The range, based on sensors to zirconium oxide differs for temperature of employment, onerous length of immersion, background, applications and applications to low cost.
It is placed side by side to the extractive models, or to zirconium oxide that paramagnetic or electrochemical and allows the analysis of oxygen in the better solution, beginning from fractions than ppm in volume to 100%.
|
|
Honeywell's high accuracy oxygen sensor range employs two ZrO2 discs with a small, hermetically sealed chamber between the discs. The first disc functions as a reversible oxygen pump, which successively fills and empties the chamber. The second disc measures the ratio of the partial pressure difference and generates a corresponding voltage. A heat element produces the 700 °C required for the ZrO2 to operate as an O2 pump. The time needed for the pump to achieve specific minimum and maximum pressures within this chamber provides a measure of the partial oxygen pressure of the environment.
Best Used For:
Industrial process and aircraft on-board oxygen generation system control, automotive exhaust gas diagnostics, service instruments, environmental oxygen monitoring, agriculture, combustion systems and environmental control.
|
|
Sensortechnics is a leading manufacturer and distributor of a wide range of sensors and fluid control devices. The product portfolio includes basic pressure sensors, rugged transmitters, submersible level sensors and customised pressure sensing systems from 1 mbar up to 1000 bar as well as liquid level sensors and switches, flow, oxygen and force sensors. Additionally, Sensortechnics offers ultrasonic air bubble, air-in-line, liquid level and fluid monitoring detectors. Fluid control devices include miniature solenoid valves, diaphragm pumps and electronic pressure controllers.
Sensortechnics has more than 25 years of experience in providing highly customised sensing products and in the development of complex integrated fluid control systems for OEM customers worldwide.
|
|
|
|
|
|
Specifications:
Sensor: Mini Zirconia Sensor
Measurement Range: 0-10PPM/0-100PPM/0-1,000PPM/0-2,000PPM/auto range or fixed range
Display: 0.75” (19.05mm) LED digital display, Color coded LEDs for system status, Alarms 1&2= RED, system fault= YELLOW, OK and online= GREEN
Response Time: <15 sec. to 90% step change @ PPM level
Intrinsic Error (accuracy):
±3PPM @ 0-50PPM/±5PPM @ 51-500PPM/±5PPM @ 501-2000 PPM O2 @ STP when calibrated @ target concentration @ STP: ±1% range
Operating Temperature: 5-45º C
Signal Interface: RS-232 service port, 4-20mA negative ground, 0-10VDC range ID and choice of 0-1VDC or 0-5VDC or 0-10VDC analog oxygen signal
Alarm Outputs: Two alarms with adjustable form C relay outputs. Configurable for fail-safe or fail-alarm mode, ascending or descending trip. One system fault relay. One alarm/relay for sensor heater OK.
Sample Port: 1/8” NPT female ports
Electrical Connections: Removable terminal blocks on back of analyzer
Power, Analyzer: 5W at 115/230VAC 50/60Hz, single phase or 12-30VDC (battery backup capability)
Environmental Ratings, Analyzer:
Faceplate: NEMA type 4, IP66
Housing: NEMA type 1, IP20
Warranty: Electronics and sensor: One yr.
Weight: Analyzer: Less than 2 lb. (0.9 kg)
|
|
| ... products without technical information |
| |
|
|