| Products 121 to 150 of 232 |
Direct reading of Total chlorine down to 0.01ppm and is unaffected by color or Turbidity of the sample
* Direct reading of Total Chlorine provides fast and easy measurements (less than 2 minutes)
* Low detection limit down to 0.01ppm
* Unaffected by sample color or turbidity
* Memory stores, tags and recalls up to 15 readings
* US EPA approved as an acceptable version of the ORION 97-70 electrode method for wastewater compliance monitoring of Total Chlorine.
|
|
|
|
|
|
Developed to meet all field and laboratory requierements, the Digital ODEON instruments combine the versatility of an easy-to-use, easy-to-read handheld unit.
Rugged, reliable and IP-67 waterproof, the ODEON measures dissolved oxygen with the new ODO optical probe, pH,ORP, conductivity, temperature, and turbidity.
Thanks to PONSEL plug and play digital probes, autodiagnostic and calibration data inside, you just have a total confidence in your readings. just measure !
You need a simple and robust mono-parameter instrument, purchase a ODEON Classic with one ultra low power probe (pH/ORP/T, DO, Conductivity or Turbidity)
You need a versatile instrument ? Purchase a ODEON OPEN ONE ! Thanks to the Open Technology, your one channel system will accepte all PONSEL probe.
Your application require simultaneously parameters from 2 probes, purchase the ODEON X
Available:
ODEON Classic line
ODEON Open line
ODEON X Line
ALWAYS READY TO MEASURE : Digital plug and play probes
ALWAYS CONFIDENCE : Autodiagnostic, status always displayed, GLP compliance
SIMPLICITY : Huge display and intuitive menus
HIGH PERFORMANCES : Mono/Multiparameters - 8 Mo Memory (100 000 datas),
FIELD INTRUMENTATION : IP67
|
|
Membrane covered galvanic
oxygen sensor
• Temperature compensation
• Up to 6 months usage of membrane
• High signal resolution
• Rapid response
• Waterproof sensor (IP 68 – 2 bar)
• Incl. calibration vessel OxiCal®-SL
• Membrane leakage monitoring
|
|
OM-51 Portable Dissolved Oxygen Meter
Product Overview
This field-type dissolved oxygen meter measures dissolved oxygen concentration (DO), oxygen concentration (O2), saturation (SAT.RATIO) and temperature of water solutions. It uses a laboratory sensor to enable BOD measurement. Waterproof construction enables use at virtually any measurement site. This meter is being used in research institutions, and at a variety water quality related production sites in the mining, agriculture, forestry and fishery industries.
|
|
|
Measurements of dissolved oxygen (DO) in industrial processes serve to control the oxygen concentration, optimize the process and yield. Besides inline measurement the off- or near-line measurement system is often used for control at different sites with a compact portable transmitter/sensor system with data-logger, sampling device and interface to download stored measurement values.
|
|
|
|
|
|
IROX DIESEL Analyzer
Portable Diesel Analysis with MID-FTIR
IROX Diesel is a Mid-FTIR analyzer dedicated to Diesel analysis: With a different spectrometer cell, it's own on-board software and a vast calibration library handling is as easy as with the gasoline unit. This instrument also uses an improved calculation model, based on Cluster analysis and MLR, for the determination of the key properties of diesel fuel such as Cetane Number, Cetane Index and Distillation Properties. Fast and easy on-site custom calibration by adding a new sample in less than 4 min.
A spectral resolution of 4 cm-1 ensures results with highest precision in less than 3 min.
IROX DIESEL has been upgraded for a new application: the determination of the FAME (Biodiesel) content in Diesel Fuel.
Features
* Cetane number (correlation to ASTM D 613)
* Cetane Index (correlation to ASTM D 976)
* Cetane Improver
* Total Aromatics (correlation to ASTM D 5186)
* FAME (Biodiesel) content in Diesel Fuel
* Polynuclear Aromatics (correlation to ASTM D 5186)
* Distillation Properties: T85, T90, T95 (correlation to ASTM D 86)
* Built-in Density Meter
* Temperature control
* Fully automated
* No sample preparation: just press RUN
* No complex technical training required
* Small sample volume: 7ml
* Measuring time: 3 minutes
* Fast and easy on-site calibration of the correlation library
* Optional 6-position sampler
* Portable for field applications
* PC/printer interface
* MINIWIN IROX-PC software
|
|
|
|
|
|
IROX 2000 Fuel Analyzer
Portable Gasoline Analysis with MID-FTIR
IROX 2000 is an extremely compact, robust and user friendly Mid-FTIR spectrometer for the automatic measurement of the concentration of the most important components of gasoline. Thanks to an improved mathematical model and the use of a built-in density meter the instrument additionally provides most reliable results for key properties such as Octane Numbers, Distillation Properties and Vapor Pressure. A large number of country specific calibration samples is stored. Outlier fuels can be easily added even without a PC.
The portability and vehicle battery options are ideal for on-site field use.
Features
* 9 Specific Oxygenates (ASTM D5845)
* 14 Specific Aromatics and Benzene (ASTM D6277, EN238)
* Total Parameters: Aromatics, Oxygen, Olefins (incl. Di-Olefins) & Saturates (correlation to ASTM D 1319)
* Octane numbers: RON, MON (correlation to ASTM D2699, D2700)
* Calculation of AKI and Drivability Index
* Distillation properties: IBP, T10, T50, T90, FBP, E200, E300
* Vapor Pressure (correlation to ASTM D5191 and D6378)
* Optional 6-position sampler
* Built-In Density Meter
* Automatic Sample Introduction
* Small sample volume: 7ml
* Fast & easy on-site calibration
* Laboratory and Field Applications
* MINIWIN IROX-PC software
|
|
|
|
|
|
Model HPM 4/6 portable vacuum meters are compact, hand-held, digital display, battery operated control units. When combined with the Hastings Instruments rugged thermopile sensors, they become vacuum instruments designed for portability and ease of use in applications where AC power is not readily available.
The lightweight control units operate with a standard 9 volt battery, and are available for display in units of Torr or mbar. Additionally, they can be calibrated to an individual sensor or set for average sensor output to test many different sensors of the same type. They are switchable to offer display for both the DV-6 (0.001 to 1 Torr) and the DV-4 (0.01 to 20 Torr) sensors without re-calibrating. These sensors are rugged, noble metal sensors which are resistant to corrosion and can be ordered with a variety of system connections to meet your system's requirements such as VCR(R), KF 16, KF 25, Glass, MiniConflat™, etc.
VCR is a registered trademark of Cajon Company.
MiniConflat is a trademark of Varian Associates, Inc.
|
|
All Isco brand portable samplers are built to withstand harsh environments and hard service.
- Vacuum-formed ABS plastic shell withstands exposure and abuse.
- Twin-wall construction with foamed-in-place insulation maximizes structural integrity along with the efficiency of ice used for sample preservation.
- NEMA 4X, 6 (IP67) controller rating for submersible, watertight, dust-tight, and corrosion resistant service.
|
|
|
|
|
|
Sievers 900 Portable TOC
The Sievers 900 Portable TOC Analyzer, weighing only 12.5 kg and measuring 35.6 x 22.3 x 46.5 cm, is the first portable TOC analyzer of its kind, bringing the lab to the field. It can be hand-carried anywhere for on-line measurement, used for grab samples, or connected to an autosampler for high volume applications in a laboratory. It requires no external reagents or gas supplies and boasts a four-minute analysis time and a 0.03 to 50 ppb measurement range.
The 900 Portable’s color touch-screen display provides an intuitive menu to quickly establish operating parameters, such as setup and automated calibration procedures, and to graph historical or real-time data. A USB drive enables easy data transfer.The Analyzer was engineered for ease of use and cost-effective operation, requiring no external reagents or gas supplies. It typically needs only a few hours of preventive maintenance annually.
The Sievers 900 Portable won Instrument Business Outlook’s 2005 Gold Award for Best Portable Analytical Instrument Industrial Design.
|
|
The 8930 Includes:
* 900 MAX Portable Sampler Controller (P/N 8972)
* Center Section (P/N 8922)
* Cover (P/N 8890)
Components to complete the system:
* Power Source/Battery Chargers
* Intake Tubing and Strainer
Optional Components:
* Base/Bottle Tray, Composite/Multiple Bottle Accessories
* Pump Tubing
* Factory Installed Options
* Support Software and Data Transfer Unit
* Cables and Interfaces
* Accessories
For pricing, part numbers, and assistance in configuring your Sigma Portable Sampler to fit your application please call Hach: 1-800-227-4224
Sampling for regulatory compliance, monitoring or combined sewer overflows, storm water outfalls, and water quality research may demand a sampler with greater sophistication and capability. If so than the Sigma 900 MAX Controller is what you need.
|
|
Pycnometer, Model 290
To measure the density of coating materials and similar liquids. Robust and light weight design, made of black anodized aluminium, or alternatively, stainless steel. Available for 50 or 100 ml capacity, also with official calibration certificate.
|
|
Isco developed the first refrigerated sampler designed to be used outdoors without an enclosure, and continues to set the standards for weather and corrosion resistance.
The all-new Isco 4700 Refrigerated Sampler is purpose-built to survive outdoors for wastewater compliance monitoring.
Our 6712FR refrigerator gives you field-proven, trouble-free sample preservation and dependability in harsh environments, along with the most advanced sampler controller available.
|
|
PRODUCT RANGE GENERAL PRESENTATION
The electronic allows the vibration of the viscometer and processes the amplitude variations in order to deliver a linear viscosity response.
960X range
• Viscosity and temperature processor
• Density for kinematic viscosity measure (optional)
• Flush-type mounting
• 24 keys keyboard and graphic display
• User friendly utilisation
• Analogic current outputs 4-20mA, relays, RS 232 - RS 485
800x RANGE
• Viscosity controller
• Maximal process temperature 200°C or 300°C
• Flush-type mounting
• Analog output 4-20 mA
• RS 485 output
• Output relay (switching power 2A - 250VAC)
7000 RANGE
• Viscosity and temperature transmitter
• Maximal process temperature 100°C
• Mounting on standard DIN rail
• Analog output 4-20 mA
• RS 485 output
|
|
VisConnect 4-20 mA Analog Output Module
VisConnect is a stand-alone, analog/digital output hub that provides access to ViSmart-delivered data via a standard 4-20 mA output signal, allowing customers to acquire multiple channels of continuous viscosity and temperature data and integrate that data into any host control platform, without the use of expensive instrumentation.
The VisConnect has two loop-powered, galvanically isolated channels of 4-20 mA output, allowing customers to configure the minimum and maximum analog outputs to correlate to 4 mA and 20 mA, or optional 0.5V to 4.5V, respectively. With an optional 2 channel analog voltage output, standard communications protocol for industrial applications, the VisConnect can connect to any legacy DAQ or host control system. An RS232 Serial communication interface is present, and an optional CAN interface will be made available in the future.
|
|
|
|
|
|
Loveland, Colorado, October 2002 — For the first time, an on-line sludge volume index measurement can provide wastewater treatment plant operators early warning of upset conditions. With Hach’s OptiQuant SVI Analyzer, operational decisions can be based on Sludge Volume results that have been determined objectively and accurately.
The analyzer gives operators a reliable, continuous analysis of Sludge Volume without frequent minimal intervention. The in-situ measurement provides accurate analysis by measuring a true representative sample directly in the aeration basin. In addition, the OptiQuant SVI Analyzer saves valuable time with on-line analysis and graphical display of the settling curve. This eliminates the need for manual plotting to determine sludge age and return activated sludge flow rate.
During a measurement cycle, the OptiQuant SVI Analyzer utilizes a sampling vessel that is submerged in the aeration basin. Liquid is purged from the vessel with air from a built-in air compressor. When the sampling vessel is full of air, a valve is opened, allowing the sludge to enter. A sampling orifice allows solids particles and flocs to remain intact within the vessel, without the aid of moving parts. The settling rate and final settled sludge volume are measured with the Infra-Cam™ device inside the sampling vessel. With the addition of an OptiQuant TS-line suspended solids probe, the analyzer calculates the Sludge Volume Index.
The OptiQuant SVI Analyzer is a convenient tool for the continuous monitoring of Sludge Volume and Sludge Volume Index in-situ, with objective, accurate results.
|
|
The Polymetron 9245 provides low-level sodium measurement in high purity water applications. With a detection limit of 0.01ppb and a range of 0-10,000ppb this analyzer is ideally suited for monitoring sodium in demineralized water, boiler feed, condensate and all parts of the steam/water cycle.
The instrument has a grab sample feature for manual calibration and measurement of one-off process samples after which the unit automatically returns to on-line monitoring. It is specially designed for low total cost of ownership.
-Measures sodium levels from 0-10,000ppb with a detection limit of 0.01ppb
-Automatic reactivation ensures optimum electrode operation and response time
-Unique temperature compensated constant pH buffering is provided
|
|
|
|
|
|
Extensive on-line chemical monitoring of both the water/steam cycle and the water treatment plant on modern power stations enables careful control of the water chemistry to achieve peak efficiency and minimise downtime due to excessive boiler corrosion or scaling. Sodium is one of the most important parameters to be measured on boiler plant. To aid in this, ABB provides monitoring systems for the effective and reliable measurement and control of sodium.
The 8036 uses an ion-selective electrode and reference electrode to measure the sodium ion concentration in demineralization plants and in the steam/water cycle of steam-raising plants. 8036 is an advanced monitor requiring very little maintenance and measures sodium ion concentrations within the ranges 0.01µg kg–1 to 10mg kg–1.
An integral heat exchanger equalises sample and calibration solution temperatures, reducing calibration times and increasing accuracy. On initiating calibration, the monitor automatically introduces calibration solution, makes adjustments and returns the monitor to sample mode; no further action is required. The auto-ranging facility provides outstanding discrimination yet gives wide application coverage, e.g. 0.5 µg kg–1 operation, 10 µg kg–1 alarm, 300 µg kg–1 shut-down. Contacts provide a remote indication of the range.
|
|
Online Beverage Analyzer Cobrix3
Cobrix3 multibev is a multifunctional online beverage analyzer with extremely short response times. It is used in beverage production and allows quick line startups after a change of product. Cobrix3 continously measures without drift and without delays a number of parameters such °Brix, Diet, CO2, alcohol, temperature, pressure, sugar inversion, extract, original extract, degree of fermentation, oxygen, and conductivity.
Economical product monitoring
* Measurement values in real-time
* Deviations are shown immediately
* Optimal use of syrup and CO2
Highest accuracy for all beverages
* Diet and sugared beverages, alcoholic beverages and mixtures
* Limits and alarms can be set for up to 256 different products
Automatic data recording
* Traceable documentation and management of all data, including targets and alarms
* Mean values, standard deviations, production times and stops, quality and performance indexes
* Cp, Cpk and quality index
|
|
|
|
|
|
TOC/TNb analysis for all matrices
The new generation of our TOC analyzers represents the consistent development of the successful concept of our proven TOC/TNb systems. Beside catalytic high-temperature oxidation at up to 1,000° C and high-sensitivity NDIR and chemiluminescence detectors, this concept is based on innovative technological solutions for signal analysis (VITA technology) and high particle-handling capacity (special valves and septum-free injection heads).
The multi N/C series consists of five analyzers covering the range from budget-priced, but powerful instruments for environmental analysis to high-sensitivity, extremely flexible systems that are suitable for most diverse applications, such as the analysis of ultrapure water, drinking water, surface water, waste water, slurry and solids. With the multi N/C 2100, another innovation has joined the series: a "double-furnace? system providing TOC analysis of liquid and solid samples without requiring an additional solids module.
multi N/C UV HS: a TOC analyzer with UV-supported wet-chemical digestion principle ? an ideal tool for the analysis of ultrapure water, drinking water and similar samples Internationally, the diversity of TOC analyzers provided is unique and ensures the right technical solution for every possible application.
|
|
The TN, or Total Nitrogen, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds (for TOC measurement) it also oxidizes bound (organic and inorganic) nitrogen compounds and ammonium compounds into nitrate (NO3-). This nitrate is present as an aqueous ion in the oxidized sample fluid in the BioTector reactor.
When TOC analysis is complete, the sample fluid is brought from the reactor into a measuring cell. Here the spectrophotometer analyzes the wavelengths applicable to nitrates. The result is displayed as Total Nitrogen (TN). A cleaning fluid is then passed through the measuring cell automatically, which ensures that operator cleaning and maintenance is kept to an absolute minimum.
|
|
|
|
|
|
The new Sievers InnovOx Laboratory Total Organic Carbon (TOC) Analyzer can run thousands of diverse, high-TOC samples—including brine and cellulose—with unprecedented uptime. The Sievers InnovOx offers unmatched oxidation robustness, dynamic linear working range, and calibration curve stability for industrial process, wastewater and environmental water samples. It is compliant with EPA, Standards Methods and ASTM regulatory methods.
The tough and reliable Sievers InnovOx uses a patent-pending Super Critical Water Oxidation (SCWO) technique to achieve superior TOC recoveries regardless of organic compounds and particulate impurities in the sample. In addition, this new process removes all oxidation byproducts and sample between each analytical run, eliminating the need for frequent maintenance.
The Analyzer uses an enhanced Non Dispersive Infra Red (NDIR) design, which has no moving parts, to allow superior linear response. The NDIR has a dynamic detection range of 0.5 to 50,000 ppm, and is capable of measuring Total Carbon (TC), Total Inorganic Carbon (TIC), Total Organic Carbon (TOC), and Non-Purgeable Organic Carbon (NPOC.
The Sievers InnovOx has a Web interface for easy, remote monitoring, an intuitive touch-screen display, and three convenient USB ports. The InnovOx is easy to set up and operate and requires no external carrier gas. The InnovOx is ready to run immediately, as it needs no prior furnace heat-up or stabilization. Maintenance is minimal, keeping total cost of ownership low. Preventive maintenance and calibration are only needed every 6 months.
|
|
|
|
|
|
CheckPoint TOC Sensor
The new CheckPoint Total Organic Carbon (TOC) Portable/On-Line Sensor from GE Analytical Instruments is the first and only battery-powered TOC measuring device. CheckPoint can easily be hand carried to any point in a water system for rapid diagnostic sampling and troubleshooting, or used on-line for continuous monitoring. It is designed for microelectronics, pharmaceutical, and power applications.
CheckPoint’s ultra portability, fast analysis time, and versatility enable new problem-solving and diagnostic capabilities at points of use away from power sources. The Sensor typically operates four to five hours using the optional battery, or continuously with AC power. It weighs just 3.6 kg (7.9 lb), and features a 15-second default measurement, adjustable in intervals up to eight hours.
The CheckPoint TOC Sensor has a dynamic range of 0.05 to 1,000 ppb, and can measure TOC in water with up to 1.4 uS/cm conductivity from CO2. CheckPoint also measures conductivity/resistivity and temperature. CheckPoint features an Ethernet (Modbus over TCP/IP) and a USB port for convenient data download. CheckPoint requires no reagents, and is easy to operate and maintain. Calibration is typically stable for six months.
|
|
Sievers 900 Series TOC
The Sievers 900 Series Total Organic Carbon (TOC) Analyzers are designed for organic analysis in ultrapure and municipal quality waters in pharmaceutical, semiconductor, municipal, and power generation applications. The four 900 Analyzers (Laboratory, On-Line, Portable, and the 5310 C for municipal water) offer exceptional ease of use, analytical performance, productivity, and reliability. The random-access 900 Autosampler provides high sample capacity and fast analysis.
The 900 Series TOC Analyzers are easy to set up, operate, and maintain. With minimal training, an operator can analyze samples in less than an hour. Unlike many competitive analyzers that use technologies such as non-dispersive infra-red, the 900 Series Analyzers require no external gasses or reagents, offer 12-month calibration stability, and usually require just a few hours of maintenance annually.
|
|
ANATEL A-1000
TOC Analyzer
Ideal for monitoring ultrapure water production and measuring the influent and effluent water at rinse stations to ensure that cleaning is complete. Monitors both hot and cold water to detect and report the most rapid TOC changes quickly.
Detection limits from 0.05 to 1999 ppb TOC
Patented stopped flow and photocatalytic oxidation
Convenient serial, analog, and digital interfacing
|
|
|
|
|
|
AOX/TOX Analyzer; DEXTAR
The DEXTAR analyzer is designed for cost effective AOX and TOX analysis in a wide range of water and solids matrices.
Product Detail
Organic Halogens pose a threat to the environment and mankind. Most substances, which include organic halogens, are toxic, carcinogenic, persistent and bio-accumulative.For this reason regulatory authorities imposes maximum permissible levels of these compounds in soil and water.
Microcoulometry is the best reference method for the determination of total organic halogen content in environmental samples; it fully complies with ISO, DIN, CEN and EPA methods. These methods lead to fast, quantitative, economical and absolute results. De DEXTAR analyzer is ideal for laboratories performing a low number of AOX/TOX samples.
Applications:
• Drinking water
• Surface water
• Ground water
• Effluent water
• Influent water
• Waste water
• Cooling water
• High salt content water
• Process water
• Pulp & paper products
• Soil & sediment
• Sludge
• Waste oil
Options:
• The DEXTAR can be used as a horizontal or vertical sample introduction system
|
|
|
THORNTON Total Organic Carbon instrumentation provides fast, continuous measurement of ppb-level organic contamination using proven UV oxidation and conductivity measurement technology. It meets pharmaceutical USP , and EP 2.2.44 as well as semiconductor ultrapure water monitoring requirements.
|
|
BioTector TOC TN TP Analyzer
The TP, or Total Phosphorous, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds for TOC measurement, it also reduces phosphorus compounds (with the exception of poly-phosphates) to orthophosphates (PO4-). This phosphate is present as an ion in the oxidized sample fluid in the BioTector reactor.
|
|
* Total Organic Carbon (TOC) Reagent Set, Low Range Test 'N Tube(TM) includes: Acid Digestion Solution Vials, Low Range TOC, Bufer Solution (Sulfate), Micro Funnel, Indicator Ampules, Low Range TOC, TOC Persulfate Powder Pillows
* Method: Direct
* Range: up to 20 mg/L C
* 50/test
|
|
MIVI PROCESS VISCOMETER FOR INLINE, ONLINE AND ON REACTOR APPLICATIONS
Simple, Rugged, Reliable, No wear part, Low maintenance, Operates in any position, Easy installation
GENERAL TECHNICAL DATA
• Maximum working temperature up to 200 or 300°C
• Maximum working pressure up to 60 bar or 150 bar (500 possible at request)
• Maximum viscosity range up to 1000 Pascal.second
• Watertightness of the body IP67
• Material 316L SS, Hastelloy, ...
• Protective coatings Diamolith, PTFE, enamel
• Exproof approval ATEX, FM, JIS
• Sanitary design on request
INDUSTRIES :
Petrol, Petrochemical, Chemical, Food & beverage, Cosmetics, Printing & coating
APPLICATIONS :
Polymerization control, Heavy fuel oil control, Inks control...
PRODUCTS :
Oil, Polymers, Fuels, Bitumen, Resins, Gels, Emulsions, Cheese, molasses, Paints, Inks...
|
|
|
|