The Biochrom 30 Amino Acid Analyzer is trusted by hospitals, reference labs, pharmaceutical and industrial labs worldwide. It accurately detects and quantifies amino acids and their derivatives in complex samples for in vitro diagnostic use and research. Applications include: clinical analysis, proteomics, drug synthesis, infusion fluids, and quality control and research applications in food, beverage and feedstuffs.
Based on cation exchange chromatography with a highly specific detection system using post column derivatization with ninhydrin. It can separate up to 56 amino acids, derivatives and other compounds with superb analysis quality and baseline separation giving precise, unequivocal peak identification and quantification-even for rare and unusual markers.
Biochrom 30 Physiological System: Lithium High Performance Columns are ideal for monitoring and screening of physiological fluids. This compact instrument can handle plasma, serum, urine, dried blood spots and CSF without costly and time-consuming re-equilibration.
Biochrom 31 Protein System: Fully automated fast and reliable quality/authenticity analysis of generic drugs and infusion fluids to a high standard that satisfies legislation.
Biochrom 32 Oxidised Proteins System: Designed to analyse complex hydrolysates in food and feedstuffs using the Feedstuff High Performance PEEK Column and buffer kit. AOAC and EEC-Directive 98/64/EC compliant.
See www.biochrom.co.uk for a video demonstration.
|
|
Precolumn Amino Acid Analyzer OPA
modular amino acid analyzer system with automated precolumn OPA derivatization, optimized for the separation of physiological fluids with up to 30 AA
Ortho-phthaldialdehyde (OPA) is the most widely used fluorescent marker for amino acid analysis and can be used for completely automated analysis of protein hydrolysates as well as physiological fluids. The detection limit for primary amino acids is as low as 0.5 pmol, 20 times better than the ninhydrin method (secondary amino acids are not detected).
The system A0426-1 is identical to A0426 but is additionally optimized for the analysis of physiological fluids with more than 30 amino acids. This system is equipped with a more sophisticated autosampler for increased flexibility in derivatization and also features a separate column oven.
The consumables kit Y1000 contains all of the buffers, salts and reagents (in powder form) required for both A0426 and A0426-1.
|
|
|
The AminoTac™ is a next-generation amino acid analyzer. The AminoTac™ attains higher analysis sensitivity of ninhydrin colorimetry, which provides high stability, while featuring a multi-segment tandem column, which provides quick analysis and longer column life. Windows™ based software makes the AminoTac™ easy–to-use and its modular design makes for compact storage and maintenance.
|
|
The Rapid Small Scale Oxidation Test (RSSOT)
ASTM D 7525 - for Spark Ignition Fuel (Gasoline)
ASTM D 7545 - for Middle Distillate Fuels
is a new method to evaluate the storage stability with the advantages of an automatic instrument.
The PetroOXY performs a massive reduction of testing time, compared to some other oxidation and storage stability test methods. This analyzer needs only a small sample and will provide the result within a few minutes, with high repeatability.
Suitable for: Gasoline (ASTM D 7525), Diesel / Biodiesel / FAME (ASTM D 7545), Grease, Oil, Food, Cosmetics etc.
|
|
MATi stands for Metrohm Automated Titration System.
MATi 1 is a fully automated and PC-controlled water analysis system based on the new 836 Titrando and the new 815 Robotic USB Sample Processor XL. In particular, it contains the new quick aliquoting device 6.9958.007, an overflow buret allowing to quickly and precisely dose after the conductivity measurement 100 mL water sample necessary to do pH measurement, alkalinity determination and finally the water hardness titration.
The MATi 1 has all it takes to perform 59 water determinations fully automatically and includes all necessary accessories and sensors. It is a ready-to-use system that fulfills all your requirements:
Full water analysis
Quick aliquoting device
PC-controlled
High sample capacity
|
|
|
For automatic determination, monitoring and LC display of the total residual hardness (water hardness) in the water. The parameter to be measured and the appropriate measuring range are determined by indicator selection and by an appropriate user program. Control via alarm horn, stop solenoid valve or similar devices. Connection provided for recorder and central control station for transmission of analysis results (0/4 - 20 mA output signal), power supply 230 V, 50 Hz with EC type certificate according to guideline 97/23/EC.
|
|
The Tekran® Series 2600 system allows the analysis of ultra-trace levels of total mercury in liquid samples. It offers unparalleled sensitivity and flexibility for those who require truly sensitive total mercury analysis.
Series 2600 is capable of providing a fully automated implementation of the new US EPA Method 1631. This method is capable of measuring waters with a detection limit of much less than the required < 0.5 ng/L (ppt).
Key Features
- Sensitivity measured in parts per quadrillion. Typical MDL: <0.05 ppt
- Atomic Fluorescence based: Greater sensitivity, selectivity and dynamic range than AA based systems
- Unprecedented modularity and flexibility
- Capable of multiple methods:
Direct reading
Single stage gold preconcentration
Dual stage gold preconcentration
- Works with stannous chloride or sodium borohydride reduction
|
|
HI 2300 performs EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature measurements. The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample.
All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user. The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy.
Conductivity readings are performed by applying an alternate current to the 4-ring probe which creates a variable voltage directy proportional to conductivity.
The GLP feature allows users to store and recall data about system status.
|
|
|
|
|
|
CarboQC
CarboQC is a dissolved carbonation meter and gives you fast, accurate and reliable determination of carbon dioxide in beverages. If combined with the PFD Filling Device, sample is taken directly from the package into the measuring chamber of CarboQC - with no loss of any carbon dioxide during sample transfer.
Accurate and traceable CO2 measurement
* One instrument suitable for lab and at-line applications
* No influence of dissolved air (oxygen and nitrogen)
* Highly accurate absolute pressure sensor, no weather and sea level influence
* No adjustment with CO2 standards necessary
* Suitable for pressures of up to 10 bar (145 psi)
High-quality performance
* Simple and easy operation
* Data memory for 99 measurements
* Battery stack quickly rechargeable for flexible operation
* Two RS-232 interfaces for transferring measuring results to a printer or PC
* Filling, rinsing and measuring by pressing only one button
* Splash-proof, lightweight plastic housing
* Minimum bench space required
Fast and easy handling directly from the package - no degassing required!
* Combination with DMA 4100/4500/5000 for simultaneous determination of the CO2 content and density/Brix (PBA-S)
* Combination with Soft Drink Analyzer 2P for additional determination of Brix actual/Brix fresh/degree of inversion (PBA-SI)
* Combination with DMA 4500/5000 and Alcolyzer Plus Beer for additional determination of the alcohol content (PBA-B)
|
|
The inoLab® BSB/BOD 740 laboratory oxygen meter has been specially developed for BODn measurements. BOD measurements are determined according to EN 1899-1 and are EPA approved.
You can store up to 7 of your own routines for frequently occurring dilution ratios. A maximum of 30 measuring samples each with 18 dilutions allow the management of up to 540 diluted samples.
The inoLab® BSB/BOD 740 can also be used as a conventional high-end oxygen meter. Additional memory and editing options are available when MultiLab® pilot is used. The entire measurement and sample management can thus be easily handled via PC.
In combination with StirrOx® G with its automatic start/stop function the inoLab® BSB/BOD 740 is the ideal measuring system for routine oxygen measurement in the BOD5 determination according to DIN EN 1899-1 and DIN EN 1899-2.
• Simple sample management
• Automatic BOD calculation
• EPA approved
|
|
|
|
|
|
Biochemical oxygen demand BOD determination is still one of the most important parameters in water resource management. It can be used to evaluate the impact of biodegradable substances in waters and waster water. With its OxiTop® systems, WTW offers a unique, modular and mercury-free instrument system. It is not only suitable for BOD determination, but also for measuring biodegradability and depletion.
In the course of growing environmental consciousness, microbiological degradability tests have become increasingly important. These can be, for example, soil surveys from waste sites or environmental impact surveys for new chemical substances. The necessary respiration measurements for anaerobic or aerobic degradation can be easily carried out using the OxiTop®-C systems with excellent analysis. WTW offers a wide range of application specific packages with appropriate sample vessels.
The advantages of OxiTop® and OxiTop® Control: simple operation, improved controllability and non-toxicity, and measuring ranges of up to 400 000 mg/l BOD (with OxiTop® Control OC 110). As the measured pressure is automatically converted the values can be directly read as mg/l BOD
|
|
|
ATI Models Q45H62 and Q45H63 are reagentless and designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking water and cooling water, and a combined chlorine monitor ideally suited for “chloraminated” drinking water. The combined chlorine system can also be used in wastewater effluents where sufficient ammonia is present prior to chlorination to result in a predominantly monochloramine residual. Unlike on-line colorimetric and most amperometric monitors, Q45H systems utilize a membrane-covered polarographic sensor that does not require the addition of chemical reagents. The Q45H system has no moving parts, so there are no pumps or motors that burn out or tubing breaks that create maintenance nightmares. All normal maintenance items are included with each system.
|
|
Double-channel measuring and control instrument for free chlorine and pH-Value - additionaly ORP optional
- Double measurement of free chlorine and pH -optionally with additional ORP measurement
- Easy and safe operation by plain text menu guidance
- Log book function
- Graphical trend display of the last 3 h
description
The dialog W 2 CL2 PR R is a sophisticated instrument for the precise measurement and control of the chlorine concentration and the pH-value - additionally an ORP measurement is optional. It is available in a wall mounted housing.
|
|
The PCA 330 series of analyzers check pH/ORP and chlorine levels in applications such as pools and spas, drinking water and influent and effluent discharge of water to ensure public safety, prevent waste and protect the environment by reducing overdosage.
Features:
• pH regulation with both ON/OFF and proportional controls
• Separate alarms can be set for pH and chlorine controls
• Parameters can be sent through SMS
• Large graphical display with backlight
• User-friendly interface
• Can store up to 3500 data, that can be displayed or downloaded to a PC
|
|
|
EX900 Kit Complete with ExStik® Chlorine meter, pH electrode, ORP electrode, protective sensor cap, 5 packs of 10 reagent tablets (50 tests), 5 plastic sample cups, weighted stand, pH 4, 7 & 10buffer packs, four SR44 button batteries, carrying case, and neckstrap
|
|
|
|
|
|
Smaller and lighter than our full size 3700 portable, the 3700C uses the same controller. The 3700C will easily pass through an 18-inch diameter or offset manhole.
Bottle choices with the 3700C are more limited than with the full-size model. The bottle options are: 24 polyethylene 500 ml bottles; a single 2.5 gallon (9.5 liter) polyethylene or glass bottle; or a single 2.0 gallon (7.5 liter) ProPak bag with holder. When using the 24-bottle configuration, the 3700C's bottle carrier makes bottle changes fast and easy.
The exclusive LD90 gives you automatic compensation for changes in head height, plus automatic suction line rinsing to prevent cross contamination. The non-contacting liquid sensor is not affected by conductivity, viscosity, temperature, or liquid composition. There are no internal tubing connections, so cleaning and tubing replacement are fast and easy. The 3700 pump outperforms most competing samplers and maintains the EPA-recommended 2 ft/second line velocity at head heights up to 16 feet, with 1/4-inch suction line. For higher lifts, we recommend our 6700 Series.
|
|
|
|
|
|
Concentration measurement (System Aquasant-MT)
The concentration measuring system measures the product concentration of organic product mixtures with one variant, taking also in account the product temperature. Surveillance of chemical reactions directly in the production line (Determination of the end point).
Measuring principle: High resolution impedance measurement
Fast product temperature measuremnt
Adaptive automatic temperature linearization
Concentration measurement
digital (Relay output) pre-alarm/alarm
analog (0/4 - 20 mA) programmable
RS-232-interface and visualization software for parameterization, online data input or data evaluation from the memory
Self controlled measuring circuit
Hazardous area version
II (2) G [EEx ia] IIC ; SEE 99 ATEX 2469; CE 0499 EMV STS 024 CE
Sample of concentration measurements of organic mixtures with one variant
Ethyl alcohol (Ethanol) in 1-propanol
Ethyl alcohol (Ethanol) in toluene
Water content in isopropanol
Acetic anhydrid in acetic acid
0-1 % water in formic acid
15 - 20 % N-Bulitium in toluene
0-10 % ethyl alcohol (Ethanol) in demin. water 1-7 µS
|
|
|
|
|
|
Speedmax 400i
Speedmax® is an inline speed of sound measuring instrument for online determining of the concentration of liquid media. Speedmax® is especially suited for measuring dynamic processes in closed pipes of an automation environment. With the measured speed of sound and the temperature of the medium the current concentration of medium can be determined on basis of well known speed of sound curves.
Speedmax® is especially suited for quality assurance, to control continuous processes and min./max.limits in pipes. All parts having contact to the medium are PFA (New Teflon). Therefore Speedmax® can be used for very alkaline, very toxic and/or very aggressive media like concentrated acids and leaches. The measuring values of speed of sound and temperature are measured from outside through the measuring pipe. Process connections are free of seals using flare technology or NPT-screwing.
The design of the pipe minimizes dead volumes over the whole geometry. For output of measuring values a current output, limit outputs and a RS 485 interface are available.
|
|
|
|
|
|
Walchem’s WCU410 Copper Controller and WNI Nickel Controller are optoelectronic on-line analyzers that measure the actual concentration of copper or nickel in solution. They are used in a variety of applications including electroless plating baths and microeth baths (including oxide-replacement types).
The WCU410 may be switched from electroless copper to microetch via the menu, eliminating the need for a second controller. It reduces the need for manual titration, improves yield, and in microetch applications improves productivity by reducing the frequency of bath change-outs.
The WNI410 is available as nickel-only, or with a pH control option which may be added in the field. Two separate pump outputs for nickel and reducer and another for pH are used, each of which is capable of totalizing either pump on-time, volume pumped, or metal turnovers.
Integrated datalogging is available to validate system performance. A USB memory stick is all that’s needed to extract data and event logs that include copper or nickel measurements, and relay status. Download logs from the USB stick to a PC at your convenience. It couldn’t be easier!
|
|
The total TDS is a mass estimate and is dependent on the mix of chemical species as well as the concentration while conductivity is only dependent on the concentration of chemical species. Some applications require the measurement of Total Dissolved Solids (TDS) in mg/L, parts per million (ppm) or parts per thousand (ppt). The TDS concentration can be obtained by multiplying the conductivity
value with a factor which is empirically determined. Eutech offers meters that allow the direct reading
of TDS values. These include the TDSTestr series, EcoScan TDS 6, CyberScan Standard Portables CON 11, CON 110 and Waterproof Portable CON 410. Bench meters for advanced level laboratory research are the CyberScan CON 510, CON 1500 and colour touchscreen research-grade CON 6000.
|
|
One high accuracy multi-range sensor measures four parameters (Conductivity, TDS, Salinity and Temperature)
* Autoranging meter offers 3 ranges to measure from pure water to salinity solution to waste, boiler and cooling water using the same conductivity cel
* 6 selectable units of measure:
µS, mS, ppm, ppt, mg/L, and g/L
* Internal memory stores up to 15 labeled readings for easy recall
* Adjustable Conductivity to TDS ratio factor from 0.4 to 1.0
* Self calibration on power up
|
|
Four-digit display for full 9999 readings with autoranging capability up to 200 ppt/200 mS
Powerful microprocessor-based surface-mount circuitry
Display prompts for simple pH calibration
Real Time Clock
Memory for 100 readings with Date & Time Stamp
Factory-calibrated with NIST traceable solutions, each PoolPro may be supplied with both certification of traceability & NIST traceable solutions for definitive calibration
pH/ORP Sensor protective cap
Fully automatic temperature compensation
Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests
Non-volatile microprocessor provides data back-up, even when the battery is changed; this assures all calibrations and memory data are retained
Extended life pH/ORP sensor is user-replaceable in the field
|
|
|
|
|
|
Micro Processor Base Salinity Meter ( SM-850)
Model SM-850 Features:
_Portability and simplicity one-hand operation
_Dual display Salinity and Temperature
_Automatic Temperature Compensation
_Average calculation, interval measuring, gram-conversion
_Use highly accurate NTC temperature sensor
_Auto power off function
_CE-Mark approval
Specifications:
Low battery indication: The "Battery symbol " is displayed when the
battery voltage drops below the operating level.
Operating environment: 0 C to 50C, <75% R.H..
Storage environment: -20C to 60 C, 0 to 80% R.H.
with battery removed from meter.
Accuracy: Stated accuracy at 23 C +/- 5 C, <75% R.H..
Dimensions: 167mm(H) x 48mm(W) x 24mm(D).
Weight: Approx. 330g. (including probe and battery)
Temperature:
Sensor: Thermistor temperature sensor
Range: -20 C to 60C, -4 F to 140F
Resolution: 0.1 C / 0.1 F
Accuracy: +/-0.5 C ,0 C to 45 C;
+/-1 °C -20 C to 0 C, 45 C to 60 C;
+/-1 F : 32 F to 113F
+/- 2 F:-4 F to 32 F, 113 F to 140 F
Relative Salinity:
Relative Salinity:
Range: 0.1% to 10%
Temperature compensation: -5 C to 60C, Automatic Accuracy:
0% to 0.9% (+/- 0.1)
1.0% to 1.9% (+/- 0.2)
2.0% to 2.9% (+/- 0.3)
3.0% to 4.9% (+/- 0.5)
5.0% to 7.9% (+/- 1.0)
8.0% to 10.0% (+/-1.5, depend on the way of measuring)
Applications:
Water monitoring, Liquid Foods, Beverage
|
|
# mmediately signal hardness breakthrough to activate regeneration
# Makes your water softening system more efficient and less costly
# Reliable, simple and accurate- with automated calibration
# Continuous monitoring in "real time"
|
|
Orion 2120XP Calcium Hardness Analyzer
The Thermo Scientific Orion 2120XP calcium hardness analyzer detects calcium as the major component of hardness in real time- providing accurate and reliable results that you can count on. Limiting the costly effects of improper water purification has never been easier.
|
|
The AQUAPOD LIGHT detects and analyzes on line nitrates in water starting from a spectroscopic technology of measurement UV
The AQUAPOD LIGHT integrates an analysis UV as well as a detection of fluorescence (in option) making it possible to reach thresholds of sensitivity about the ppm (for the majority of the parameter the µg/L (hydrocarbons)
Easy to install, without reagents nor calibration and maintenance, the AQUAPOD LIGHT ensures you a cost of very low exploitation.
The AQUAPOD LIGHT UV FLUO can accept any type of physico-chemical sensors Modbus RS485, 4 - 20 my...
Moreover, thanks to its exits Modbus, Profibus and Can Open, the AQUAPOD LIGHT can be interfaced quickly towards any system of supervision or communication GPRS or STN
|
|
|
|
|
|
Modular System
The Hach sc1000 Multi-parameter Universal Controller is a fully modular system consisting of a Display Module and one or more Probe Modules. The Display Module and Probe Module must be ordered separately.
Display Module-The sc1000 Display Module is a full-featured controller with a large color touch-screen display. The intuitive, easy to use interface can be used for any number of parameters. One Display Module controls either a single Probe Module or a number of Probe Modules connected by a digital network. The Display Module is fully portable and can be disconnected and moved anywhere within the network. The Display Module must be ordered separately from the Probe Module.
Probe Module-Each sc1000 Probe Module provides power to the system and can accept up to 8 digital sensors. Probe Modules can be networked together to accommodate many more sensors attached to the same network. Only one Display Module is needed for a networked system. The Display Module must be ordered separately from the Probe Module.
Digital Network-Connect up to 32 participants in an sc1000 network. Network together mulitple Probe Modules to meet almost any application's needs. Participants are defined as anything attached to the network including probes and optional cards but not counting the Display Module or Probe Modules.
|
|
The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.
As well as the turbidity/SS indication, this transmitter can indicate signal output response time, alarm level setting and so on.
You can control the turbidity/SS utilizing its functions fully.
|
|
|
|