The C-LEVER® II by REMBE® sets the benchmarks in the field of industrial flow metering.
Its unique technique achieves an excellent accuracy of ± 0,25 % of the volumetric range for nearly all flowing bulk and solids.
The accuracy of the C-LEVER® II is almost independent from product, its density, form, friction and elasticity. Severe changes of flow and/or pulsations caused by rotary valves or screw feeders do not influence the accuracy.
Compared to conventional measuring systems - based on volume, speed or weight - the REMBE® system measures the product flow inline.
The C-LEVER® II is made without any mechanical moved parts (actuators, pivot bearings, belts). As a resulting from this no post calibration is required. All electronical components are mounted outside of the product flow.
|
|
|
Equipped with the newest microwave technology, our solid flow meter MF 3000 is designed for flow measurement in metallic pipes from a few kg/h to many t/h. The system is suitable for on-line measurements of powders, dust, pellets, and granular from 1 nm up to 2 cm in pneumatic or free fall condition. Installation is simple and cost effective via a welded base, through which the sensor is screwed flush with the inside of the pipe.
|
|
The Working Principle
Bulk material supplied from above passes a constant-
speed impeller wheel driven by a three-phase current
motor, diverting the material radially. The tangential
Coriolis force acting on the wheel blades causes drive
torque changes in proportion to the flow rate sensed by
a load cell. Based on torque and speed, the Congrav®
microcomputer computes the current flow rate, which is
both displayed and issued as a signal for recording or
control of a variable-speed upstream feeder (e.g.
screw feeder, rotary valve).
The Advantages
Ingredient characteristics
or height of fall do not
affect accuracy
Models
CDW 150: max. rate 40 m³/hr
CDW 250: max. rate 100 m³/hr
CDW 350: max. rate 160 m³/hr
|
|
|
|
|
|
Fuel flow meter DFM is a simple and easy-to-use fuel flow meter with electronic counter designed for measuring fuel consumption and engine operating time of vehicles, tractors, any mobile or fixed installations with diesel engines.
All readings are shown on the electronic display of the meter. Switching of indications is made by special contactless key.
There exist two modifications of fuel flow meter DFM: MT - monitoring of fuel consumption and engine operating time, T - monitoring of fuel consumption.
Fuel flow meter DFM is protected from overstatement of readings and intervention. Even if you try to blow the meter by air the fact of intervention will be registered.
Fuel flow meter DFM contains the following counters (* this counter is accessible only in MT version):
- Total fuel consumption counter, l
- Instant fuel consumption, l/h
- Total engine operating time counter, h *
- Engine operating time in “idling” mode counter, h *
- Engine operating time in “optimal” mode counter, h *
- Engine operating time in “overload” mode counter, h *
Advantages of fuel flow meter DFM:
- Monitoring of fuel consumption and engine operating time (MT version)
- Moderate price
- Strong metal molded case
- Built-in fuel filter
- Electronic correction of measurement inaccuracy in all flow range
- Ease of mounting and service
- Protection from overstatement of readings and intervention
- Measurement inaccuracy is no more than 1%
- Flow range (DFM-5 - 2...80 l/h, DFM-7 - 5...200 l/h)
- Temperature range -45...+60 ºС
- Separate account on engine behaviors
- Reliable electronic display
- Certificate of conformity (CE)
|
|
APPLICATION
□ Fully electronic compact heat meter or compact cooling & heat meter with impeller scanning for recording energy and volume data.
□ Highly accurate recording of all billing data in a heating circuit or a cooling & heating circuit at medium temperatures up to 90 °C.
□ Horizontal and vertical installation, also overhead for Model 447/450.
|
|
APPLICATION
Horizontal installation
For hot water up to 120 °C
Model 414 with carbide bearing
Overall and connection dimensions to DIN ISO 4064
DN15-50mm-PN16
DN 20 - 40 mm - with flange, PN 16 and PN 40 available
Operating pressure to DIN 2401
Max.24V,(SELV),0.2A
Protection class IP 65
Volume measuring component for measuring heat tor billing hot water consumption
Facility tor remote transmission of flow rates
Cable length: 3 m {0.25mm2)
|
|
|
There are two methods for the safe installation of flowmeters in hazardous areas. Either the electronics must be housed in heavy flame-proof enclosure with expensive armoured cable connections (Eexd/Flameproof) or the electronics can be intrinsically safe (IS). The preferable approach is that the flowmeter is intrinsically safe and is not capable of igniting volatile gases. A normal low-cost, non-armoured cable is used to connect the flow-meter to the safe environment where isolator barrier devices are installed. These devices limit the energy passing to the IS transmitter electronics.
|
|
|
|
|
|
Mobile Measurement kit FM-1-B FLUID-CHECK in suitcase for :
- Flow rate sensors
- Leakage sensors
- Temperature sensors
- Pressure sensors
Examples for :
Fixed displacement pumps Pumping capacity
Variable capacity pumps Percentage of leak oil
Oil coolers Flow characteristics
Water coolers
Differential cylinders Leak oil
Synchronous cylinders Sealing damages
Plunger cylinders Moving speed
Oil motors Leak oil
Pressure accumulators Bladder control
Charging behaviour
Nitrogen charge
Technical Data :
- With multi-purpose display with one separate analogue input, with
4 – 20 mA and scaling facility
- Suitable for display of input channel A or input channel B as well as the sum A+B, the differential A-B or the ratio A:B
- Display range +/- 4 1/2 decades at 15 mm size
- Power supply 115 / 230 VAC or 18 – 30 VDC
- Setup of zero and full scale by means of two front keys and
menu support
- Selectable linearisation functions
Included :
- Power cord 230V AC
- Connecting cable with plug
M12 connector for kit and sensors
- Suitcase made of plastic (black/blue)
Outer dimension 340 x 275 x 84 mm
- Technical documentation and operating instructions
|
|
Open Channel Flowmeter FMC-4000/FCA
Flowmeter to mounting on waste-water open channels or boxes
This low cost mounting system allows to measure, totalizer, average and peak flow at small open channel and to transmit all data by Modbus communication, and optionally also Radio or GSM. Also optionally can be powered by means our stand-alone ABF device with solar cell, allowing to mount in isolated areas.
|
|
Continuously monitor, display, totalize and data log flow through any flume or weir. The OCF 4.0 includes a non-contacting ultrasonic sensor that mounts just 8" (203.2 mm) above the flowing water. It is accurate (±0.25%) and reliable. There is no obstruction to flow and no fouling. Use the built-in Keypad/menu system to select your flume or weir from the Menu and to choose measurement units (gallons, liters etc.)
- Non-Contacting Ultrasonic Sensor
- Accurate and Verifiable
- Built-in 50,000 point Data Logger
- Windows Software
- USB and RS232 Outputs
- 4-20mA/0-5V Output
- 16-digit Totalizer
- 3 Programmable Control Relays
- Password Protected
- Simple 3-key Calibration
|
|
Open Channel Flow Measurement Isco 4200
No single measurement technology is suitable for all open channel flow monitoring applications. Only Isco offers you a choice of ultrasonic, submerged probe, bubbler, and area velocity flow meters. Whether you need a permanent meter for a flume or weir, short term measurement with no primary device, or flow and pump performance monitoring at a lift station, Isco has the solution. And our application experts are available for a free, no obligation consultation to help you choose the best technology for your monitoring sites.
|
|
The RFIK mechanical hydraulic tester provides the ideal solution for servicing and commissioning
hydraulic circuits on agricultural and other mobile machinery.
The kit comprises of a direct acting flow indicator with built in thermometer, a loading valve and a pressure gauge all built into a strong steel case with a removable lid.
The unit is self contained and requires no electrical power. The dials are clear and easy to read.
Installation is extremely simple and the test kit can be connected into either the pressure or return lines. The loading valve and pressure gauge allow a progressive build up of system pressure in complete safety.
The test kit provides the service engineer with quick, accurate and simple performance testing of pumps, motors, valves, cylinders and complete hydraulic
circuits.
Note: This unit is not designed for permanent installation.
|
|
Compact vibrating level switch for liquids
For universal use as overfill or dry run protection system
All advantages in an overview
- setup without adjustment
- screwed piezo drive
- SIL 2 qualified
- product-independent switching point with high reproducibility
- wear and maintenance-free
- instrument from the plics-family
|
|
| ... products without technical information |
| |
|
|