| Products 91 to 120 of 299 |
Level instruments are the latest addition to the Badotherm range. We have added these to offer our clients a premium quality product and solutions for level measuring
The range of Bliss-Badotherm level instruments includes:
Tubular suppliers of level gauges for general applications with a maximum pressure
up to 7 bar and a maximum temperature of 200 °C.
Reflex level gauges with a visible length of 200 mm to 3000 mm for high
pressures of 280 bar at 40 °C.
Transparent level gauges for dark dirt fluids with a visible length of 200 mm
up to 3000 mm for high pressure of 210 bar at 40 °C.
Magnetic level indicators, like the drag magnet type and the bi-colour roller type, for pressures up to 30 bar with a maximum temperature of 350 °C.
|
|
| The Barksdale Bypass Level Indication System combines the convenience of a sight glass and the strength of a Stainless Steel tube with the only difference: there is no class to break or professional seals to leak. |
|
| Innovative system for monitoring the fluid level inside atmospheric tanks. This system detects the static pressure generated by the fluid height by means of a tube and professional displays the fluid level up to 4 m., the volume or filling percentage. The control unit is provided with an intuitive and complete professional software that allows to set 2 alarm levels (SPDT) and/or activate remote alarm devices. High accuracy (+/- 1%). Very easy installation directly on the professional tank or at a distance up to 50 m. far. |
|
Enraf’s Field Display & Interface Unit (FDI) provides professional tank inventory information in the field, where it is needed. It is a versatile, EEx-d approved instrument with several interface options, which can even be part of W&M approved applications.
The design of the FDI is therefore based on reliable and uninterrupted data
supply in all circumstances. The unit can be used in stand alone mode using the Enraf Bi-phase Mark communication protocol for direct connection to an Enraf gauge, or any other gauge using this standard communication protocol in tank farms. The unit will interrogate the gauge and display its measured data.
To update its display in bigger installations where a remote tank inventory
system is available, the indicator listens to the communication between the field instrument and the remote system. When the communication between system and gauge fails, the FDI automatically takes over the scanning of the instrument to provide the measurement data in the field. After sensing the scanning from the system again, it returns to the original configuration. |
|
| The VLI-2500A and the compact VLI-1250A provide safe durable and accurate direct tank level indication for most any industrial liquid or environment. |
|
OCIO is an innovative system for monitoring the fluid level inside atmospheric tanks. The system detects the static pressure generated by the fluid height by means of a tube inserted in the tank and professional displays the fluid level or volume. The new design and suitable solutions guarantee a reliable and repeated level indication.
The system is composed of:
A tube for detecting the static pressure. The tube with its end is inserted from the top of the tank and dipped in the fluid down to the bottom of the tank.
A control unit for level display and system management. The unit is provided with intuitive and complete software and allows the connection of two alarm or lock devices.
By means of the software it is possible to:
- set the type and the dimensions of the tank
- define the level alarms
- define the level indication
- define the unit of measurement
- calibrate the instrument
Depending on the set alarm levels, the control unit activates or deactivates the contact working as a remote switch starting the alarm devices or cutting the power dispenser off the connected equipment |
|
Level measurement à la carte
WEKA stands at the forefront of Magnetic Level Indicator state of the art for almost any operating conditions. Most of the applications can be served with one of our standard instruments. For special applications we invite you to draw from our wealth of more than 40 years experience in the design and manufacture of Magnetic Level Indicators installed all over the world in extremes of environments and applications. No matter how complex your requirements are, the patented and field-proven WEKA magnetic float indication rail system will meet your liquid level indication requirements. |
|
Self Professional adhesive Level Indicator Labels
Simply stick the Self Adhesive Level Indicator Professional label on the fire extinguisher, overlapping the calculated level. Apply heat to the label for a few seconds and see the level clearly indicated.
Standard temperature range: 0-27°C, (Purple & Blue)
Higher temperature range: 25°C - 35°C (Blue)
Sizes: 25mm x 250mm and 25mm x 500mm long. |
|
Designed to remain non-intrusive, the Sentry SR offer viable alternatives in demanding applications where other technologies fail.
The Sentry SR Series of professional lasers are the latest in laser technology designed for both level and positioning applications. The Sentry SR operates up to 25 m and is housed in a rugged, explosion-proof enclosure.
|
|
| The VISY-X system supplies information on professional tank professional levels. As an electronic dip system it serves for the protection of people and the environment. VISY-X has been especially designed for application in petrol stations. Each VISY-X system consists of 1 to 16 detection VISY-Stick and a conversion system VISY-Command. |
|
Portable open electronic gauge
The UTImeter Otex is a portable liquid level caliber designed to be operated under open conditions on petroleum and chemical tanks where open gauging is permitted. The sensor is calibrated once at the factory and does not require subsequent calibration. The temperature probe is a RTD element. The characteristics of the RTD are stored inside the sensor. The sensor is sending true temperature values to the electronic box. Therefore changing a sensor or a tape does not require a new calibration. The unit is used for custody transfer, inventory control measurement and free water detection on marine vessels and shore tanks. The HERMetic UTImeter Otex is set on the open gauging hatch.
The unit enables 3, optionally 4 measurements in one single operation
- Ullage
- Temperature
- Oil-water interface level
- Innage, Reference height (Visc Version) |
|
LEVEL LIMIT VALUE
- capacitive suppliers of level switches for liquids and bulks, lateral
and vertical installation, PNP exit, also for aggressive media, also for
strongly got dirty suitably.
- opto-electronic level switches made of high-grade steel for liquids, that
lateral and vertical installation, PNP exit, remarks for high
Temperatures and pressures, hygenic applications
- Float switches from high-grade steel and plastic one, for lateral and
vertical installation, switching contacts reed switches, up to 4 switching points,
customized remarks
KONTINUIELICHE LEVEL METERING
- capacitive level probes for liquids and bulks in
High-grade steel or plastic one, exit 4-20mA, for vertical installation, for
aggressive media, remarks with removable head and
exchangeable or shortenable probe staff
- Niveausonden with float principle, for liquids, exit 4-20mA
or resistance signal, Kundensprezifi remarks, in high-grade steel
or plastic ones |
|
| The capcitive filling level systems operate according to the three-electrode principle. With this principle the container or an additional electrode serve as a counter-electrode to the probe electrodes. For this reason it is necessary with this system that the container is of a conductive material or a "substitute electrode" is fixed to the container wall, e.g. copper foil. These systems are available with probes for analogue filling level measurement of for detection of 1, 2 or 3 measuring points. The position of the switching points and the analogue measuring area is user-definable within the possible effective range and therefore it can be determined for optimal matching of each application. Level measurements of bulk material, liquids or pastes are possible with a dielectric constant as of år 1,1. |
|
The VEGAWELL 51 is a sensor of water level equipped with a ceramics-capacitive cell CERTEC® of a purity of 99,92%. This cell is adapted perfectly to the applications of measure of level in the field of the cleansing and the professional water treatment because of its exceptional corrosion resistance, to abrasion and overpressure. This principle of measurement is also particularly well adapted to the measurement of flow in opened channel, in particular on effluents with foam on the surface which is likely to disturb the sensors with usual ultrasounds on these applications.
Cell CERTEC® offers other advantages, in particular a surface levelling with 100% which excludes any risk from deposits and an excellent stability in time lower than 0,1%/2 years, the whole largely contributing to decrease the maintenance actions.
Its very small diameter of only 22 mm in fact a sensor easy to establish even in wells or very narrow tubes of measurement.
The output signal is available in 4... 20 my HART®, the measurement brackets go until 250m in class of precision 0,2. The cable carrying equipped with a capillary compensation with the pressure atmosphere is deliverable for lengths active until 800m.
The typical applications are the measurement of level or differential of level on well, drillings, basins, tanks, ballasts as well as the measurement of flow on open channel.
|
|
Applications: Level or interface metering
Special features: Reliability
Robust construction with magnetic transmission of measured values.
Big scale with 180°-wide angle ball-display.
Can be used in hazardous areas.
Self-monitoring function
PTB approval for zone 0
Technical data: Process temperature: up to +350°C
Nominal pressure: up to 400 bars
Options: Polypropylene professional fittings, PVDF- and PTFE-lining.
Manufacturer of limit switches
Reed contact with electronic professional transmitter, 4-20mA, HART®
Approval: Possible by TÜV, Germanischer Lloyd and Bureau Veritas
|
|
KONTINUIELICHE LEVEL METERING
- capacitive level probes for liquids and bulks in
High-grade steel or plastic one, exit 4-20mA, for vertical installation, for
aggressive media, remarks with removable head and
exchangeable or shortenable probe staff
- Niveausonden with float principle, for liquids, exit 4-20mA
or resistance signal, Kundensprezifi remarks, in high-grade steel
or plastic ones
Level border conditions: Capacitive contactors,
optical contactors,
Float switch |
|
Continuous level sensors suppliers designed with potentiometric output signal, 3 adjustable alarms or 4/20mA industrial converter. Brass stem and NBR float or stainless steel AISI 316 executions. Contact distance 10 or 15 mm. G1 1/4" - G2" thread connection of Ø52 - Ø92 flange in aluminium or stanless steel.
Executions approved for hazardous areas (EX zones) are also available. |
|
LIDEC manufacturer of level switches: a dependable solution for liquids detection
Developed in cooperation with “Paris VI” University, the Lidec series liquid manufacturer of level sensors series are especially designed for marine applications.
They provide a reliable solution to liquid level detection.
Their operating principle, a patent granted to Enraf Marine Systems, is based on the propagation of a surface wave inside a stainless steel probe.
This principle is fully static, without vibration or moving parts. A "self-monitoring" function ensures the reliability of this equipment. This allows these detection to be used in safety systems such as overfill protection, bilge well alarm and water ingress detection... |
|
"Nivotemp 63 K + KN, 63 K-VA + KN-VA
Modern production facilities employ more and more plant automation systems and computerized controls. These allow the monitoring and control of hydraulic and lubricating systems. Traditional level controls are focused on pump protection i. e. a typical system is equipped with a suppliers of level switch with one or two contacts. These contacts protect the pump from running dry in the event of leakage..
Modern systems provide the opportunity for a pro-active leakage control by the use of continuous signals.
An analog output of 4-20 mA signals continuous signals the fluid level. Deviations from the ""normal"" are detected instantly and can be transformed into many types of action. In case of a catastrophic failure such as a burst professional hose the pump could be shut down immediately rather then let it run until the traditional switch turns it off after a large volume of oil has spilt.
The Nivotemp 63 versions provide continuous analog signals for liquid level only or for level and temperature combined. They are available in two standard length or in 150mm increments. The flange dimensions are the standard ones used for filler/breathers ( DIN 24557/2). In addition the units can be combined with our Fluidcontrolterminal which makes oil care even more technically advanced.
The 63..VA versions are suitable for use with high water based liquids ( HFA).
easy, cost effective installation
continous level / temperature control
4-20 mA analogue outputs
flange standard
one cable for two functions" |
|
COSENSE INC Level and Distance Measurement is not just another level or proximity sensor supplier:
-Contact, Non-Contact and Non-Intrusive (sense "through" tank walls without penetration) Level and Proximity
-No moving parts to break or jamb
-Titanium, Tefzel, Stainless, CPVC, Monel....
-Cryogenic (-300F/-184C), High Temperature ( 750F/398C)
-Subminiature with .0005 inch (.013 mm) accuracy
-Full Scale measurements as small as .01 (.25 mm) can be used to measure inside test-tubes!
-Large robust designs and subminiature sensors
-Aerospace, bio-medical, nuclear, pharmaceutical, process, lab, semiconductor,automotive, power.....
-OEM and SPECIAL REQUESTS WELCOME
-COSENSE All Tefzel Manufacturer of level sensors, starting at $95.00 US Dollars, (relay contact or loop powered options) for use in practically any acid, caustic, water, oil.
-COSENSE sonic and acoustic systems work independantly of conductivity, dielectric, color, opacity, density. Models for most applications available. Call, email or fax us for FREE ASSISTANCE and product information. If we don't have it, we may be able to design a custom solution just for you.
|
|
Special features:
Reliability
Robust construction with magnetic transmission of measured values.
Wide and clear scale.
Can be used in hazardous areas (Zone 0).
Technical data:
Range: up to 6 m
Connection: up to DN100 / ANSI 4"
Nominal pressure: up to PN 320
Process temperature: -50°C ... +260°C
|
|
Nivofix NM-...HK/HP
Mechanical Level switch suppliers for liquids. A magnet-equipped
float triggers a reed switching in a pre-fixed position.
top or bottom assembly for min. or max. control
reliable
good repeatability |
|
Continued investment in research and development allows the introduction of new products which are future-orientated and can be readily integrated into the new automation systems of today.
Since 1953, Endress+Hauser has manufactured level gauging instruments for industry and has developed and optimised a wide range of measuring techniques. Today, a wide range of designs and process connections are available accompanied by application-specific interfaces. All instruments have been extensively tested and certified. |
|
| The capcitive filling level systems operate according to the three-industrial electrode principle. With this principle the container or an additional electrode serve as a counter-electrode to the probe electrodes. For this reason it is necessary with this system that the container is of a conductive material or a "substitute electrode" is fixed to the container wall, e.g. copper foil. These systems are available with probes for analogue filling level measurement of for detection of 1, 2 or 3 measuring points. The position of the switching points and the analogue measuring area is user-definable within the possible effective range and therefore it can be determined for optimal matching of each application. Level measurements of bulk material, liquids or pastes are possible with a dielectric constant as of εr 1,1. |
|
Level sensor manufacturers acc. to the measuring principle of the guided microwave (TDR)
For universal use in light solids and liquids
All advantages in an overview
- setup without adjustment
- independent of product features
- insensitive to dust, vapour and buildup
- probes can be shortened
- signal processing ECHOFOX for echo analysis with Fuzzy-Logic
- instrument from the plics® family
Version with exchangeable cable (ø 4 mm) or rod (ø 6 mm)
Measuring range cable: up to 32 m
rod: up to 4 m
Process professional fitting from G¾A
Process temperature -40 ... +150 °C
Process pressure -1 ... 40 bar (-100 ... 4000 kPa)
Accuracy ±5 mm |
|
|
|