TF-100 Series Vibrating Level switch manufacturer
with TF-L-Relay Output and TF-P-Transistor Output or with TF-T-Current Output
The TF-100 series tuning fork is a point level switch for clean liquids and light slurries. It is available with Relay, Current, and PNP outputs. The TF-100 series carries FM hazardous area approvals.
The TF-100 Series vibration technology level switch is an excellent choice for most high or low-level liquid level measurement requirements. The TF-100 requires no calibration and is not affected by changes in electrical properties of the material being measured.
Relay, current, or PNP outputs
Temperatures from -58ºF to 302ºF, Pressure from vacuum to 928 psi
No calibration required |
|
In order to eliminate false alarm given due to medium with high viscosity sticking onto the probe , a special material acting as an insulation industrial electrode have been added in between the active section and the grounding section.
As shown in the diagram, sensing probe always experience medium clogging on it and thereby produces a capacitance and resistance between the 3 parts. Since the electric field between the active section and the guard section is round shaped, there will be no current passing through the medium between the electrodes.
The Admittance level switch manufacturer uses this principle, to add a guard section between the active section and the grounding section to block the admittance current to reach the vessel wall from the medium between the active section and grounded electrode. Although there would be a small amount of admittance current between the guard section and the active section, the circuit would not take this current value into account. Due to the guard section, only the admittance current change between the active section and the tank wall will be detected by the circuit, thus only when the sensing probe is in contact with the medium will there be a precise signal.
Features
Not affected by material coating on the sensing probe.
Easy installation.
Stable operation, not affected by temperature.
Time delay function of 0~90secs.
Housing protection: IP65.
DPDT /5A output.
Maximum temperature: 550°C.
High / Low fail safe selectable features.
Applicable in liquid, syrup, solid, grain and interface detection. |
|
Universal III
509-7X Series Transmitter using 409-1000 Series Electronics The Universal III provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on the RF sensors.
Smart Check Well
509-7X Series Transmitter using 409-1000 Series Electronics The Smart CheckWell provides capability of water well measurements to 800 ft. depths.
RCT RF
RCT 10, 11, 12, &, 13 Series Transmitter with HART Protocol using 409-T Electronics The RCT Series provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on sensors.
Universal Lite
509-1X Series Transmitter using 409-1400 Series Electronics The Universal Lite provides cost effective measurements on liquid applications that do not leave a significant process coating deposits on sensors.
True Level
509-8X Series Transmitter using 409-2000 Series Electronics The True Level III provides the ability to provide accurate measurements on homogeneous (blended) liquids.
Drop-In-Displacer²
509-7X Series Transmitter with HART Protocol using 409-1000 Series Electronics The Displacer² provides the ability to replace maintenance intensive electrical or mechanical displacer assemblies with alternate technologies such as RF Admittance.
SLT II
509-5X Series Transmitter using 409-1200 Series Electronics The SLT II Series provides advanced internal Admittance circuitry that enables the system to ignore significant process coating deposits on the RF sensors. |
|
| Providing continuous analogue output, through a single float travelling it length. The stem length can be up to 1Metre long. With 2 wire resistive output - and can be fitted with an optional low level alarm. Fitting to to the tank via internal M16 to externally via a mounting bush or flange. |
|
The RPS-401A, RPS-426A analog ultrasonic sensor is mounted in a barrel housing and is completely self contained. It is powered by 20-30VDC and is reverse polarity protected. It also has a narrow beam angle which enables it to get into tight places. The RPS-401A, 426A has 2 short circuit protected analog outputs, 4-20mA and 0-10VDC.
The RPS-401A barrel is constructed of plastic Valox and is available in two adjustable measuring ranges: 4-40" and 8-80".
The RPS-426A has a stainless steel barrel housing and an adjustable measuring range of 8-80".
A standard 6 foot cable is provided. An optional quick disconnect plugs is available. |
|
| The vibrating blade detector VEGASWING 60 became the standard for the anti-overflow applications on liquids. This solution offers maximum guarantees of safety because independent and not influenced by the same physical sizes as measurements of level. Concerned with safety units (valve, pump, warning signal, alarms,...) are directly connected downstream on a circuit separately which can be controlled regularly by simple support on a key test located on the off-set electronics of the detector. The threshold does not require any adjustment, it completely transparent because is given by the length of the sensor and the assembly. The principle is without wear and maintenance. Aggressive products are detected with reliability with materials with high chemical behavior like the hastelloy or enamel. These detectors offer a very broad applicatif spectrum because insensitive with the variations of dielectric, viscosity, pressure, temperature and industrial foams. They in addition have a continuous self-monitoring which announces any defect instantaneously (rupture of line, failure of the blades, corrosion, short-circuit, etc.). Approvals ATEX II G for explosive zones are available and of the versions answering the classes of safety SIL 2 and SIL 3 according to standard IEC 61508 are deliverable. |
|
A level control system consists of a sensor, controller, cock or pump and may be on-off or modulating. It is vital that your professional boiler water levels be monitored safely and accurately.
- Products compliant with all relevant European standards & regulations
- Safe working environment for your employees
- Reduce the risk of accident in the boiler house |
|
Applicable in environments with high temp., high pressure, strong acid, strong alkali and hazardous locations.
The structure is simple but durable and reliable. It is also with various optional devices for upgrade in use.
A Level Transducer or Magnetic switches can be installed and adjusted with no need to stop any process.
It is not operated by electricity and with not be affected by power failure.
The flag display is scaled by a piece of color, division every 10cm, one can easily read the levels height.
Multiple applications for textile dyeing, sewage water processing, power generating, hot coal oil boiler and petrochemical industries.
|
|
Measuring length Max. 3 meters
Connection DIN-flange DN 10...DN 25
ANSI-flange 1/2"... 1"
Material st. st. 1.4571
Max. pressure PN 40/300 lbs, max. temperature:200 °C
Accuracy transducer +/- 1 mm
Option transmitter 4-20 mA, contacts
|
|
Bühler Liquid-level control for external mounting NS 10/...-AM
The control of liquid level in reservoirs, gear boxes or other complex constructions often requires the use of controls than can be mounted externally with a visual indication of level.
The NS 10... range of level controls has been designed specifically for these applications. The visual level indicator is a standard item and has excellent visibility from any direction. The indicator itself is guided in a transparent tube and is moved by the magnetic field of the unsinkable float inside the stand pipe . The electrical contacts or a continuous level transmitter are mounted to the indicator scale. The contacts can be adjusted to any position.
The connection to the main structure can be by means of standard industrial pipe fittings or flanges. Contact types MKS-1/W-L-24V are equipped with an LED.
compact dimensions
sight glass does not contain fluid
visual indicator
unsinkable float
infinitely variable adjustment
rugged design
optional continuous analogue signal 4-20 mA |
|
Application description:
The conductive rod probe SAT in combination with suitable switching devices (e.g. fill level limit switch SRA-100, SRA-101, SRA 102, SRE-200) is used for limit value detection and niveau control in electrically conductive liquids. Also possible is the detection of overflow, dry run, humidity, flow.
Depending on the selected type, it is possible to realize up to 6 switching points. The longest rod operates as ground reference.
The connection housing is protected against splashing water IP65. |
|
Current Loop Powered, no Extra Power necessary
A Universal Display Unit For all 4-20 mA Transmission circuits
Works with Standard DIN 43650 Plug
4 Digit LCD Display, Free Scaling of Display Value
3-keys operation
4~20,10~50mA Ranges |
|
Suitable for high temperature, high pressure and corrosive environment.
Not affected by noisy, dusty, misty and changes in the temperature.
No blind distance, ideal for different tanks.
Economic for large tanks
4~20mA output compatible for most control systems and meters |
|
| The CS001 RF Capacitance Transmitter offers a compact and affordable solution to a wide variety of level sensing applications. With 4-20 mA and 0-5 VDC or 0-10 VDC selectable outputs, the solid state sensor provides accurate, proportional level measuring in many extreme process temperatures and fluid conditions. The CS001 features a simple, fully programmable four button calibration to set for whatever media it is measuring. Its 316 stainless steel probe comes in lengths up to 120" and is available in NEMA 4 or explosion-proof housings. |
|
Our unique inverse frequency-based approach to capacitance technology ensures accurate, reliable and repeatable measurement even in dusty, turbulent, and vapourous environments, or in situations with product build-up. Because even a small level change creates a large change in frequency, our instruments provide better resolution and consistently outperform conventional devices. With special features such as Active Shield technology and modular probe options available on various models, they offer practical solutions to a wide variety of continuous level measuring challenges.
SITRANS LC 300
Capacitance level measurement instrument for liquids and solids, high accuracy applications such as food and beverages, pet food and bulk solids; ideal for challenging processes involving vapor and dust.
SITRANS LC 500
Capacitance level and interface monitor/controller for extreme and critical process conditions, such as oil and "liquid gas", toxic and aggressive chemicals and vapors. |
|
The SC120 probe and CN200 level transducer can continuously measure as well as control the level in a wide range of applications. They can be used in conductive and non-conductive liquids, solids such as grains and feeds, as well as slurries. The SC120 probe sends an mV signal to the CN200 transducer, which converts the (mV) signal into a 4-20mA signal. Unlike the SC 404, the SC120 working with the CN200 transducer has two adjustable level controls in a scale of 0-100% with bar graph level indication, as well as a Zero and Span adjustment.
FEATURES
*Wide range of applications/industries
*I.e. liquids, oils, corrosives, solids such as powders and grains, etc.
*Functions on conductive as well as non-conductive medias
*No moving parts, rugged construction
*Easy economical installation, accurate and reliable measurement
*Unaffected by coating media or aggressive products
*Can operate ate high temperatures and pressures
*Available in 316S.S. threaded, sanitary and flanged process connections
*3A approved
Sitron's SC120 probes and CN200 transducers provide reliability, easy of use and installation. |
|
| The Ramsey CAP Series Capacitance Level Control is designed for point level monitoring of solids, fluids or slurries in bins, vessels and chutes. This control can eliminate spills, material waste, and down time by preventing bin overflows, plugged chutes and empty bins. It works equally well as a high or low level indicator with plastics, food, chemicals, mineral slurries or other materials. |
|
The vessel, capacitance industrial electrode and medium to be measured form together an electrical capacitor. The level change is monitored as a direct result of the variation in capacitance value around the probe, dependent upon the degree of immersion.
Advantages
- Rugged sensors suitable for universal applications
- High chemical resistance
Applications
- Level measurement and level detection of liquids and solids
|
|
OptiLevel is the leading edge system for liquid level measuring in smaller storage tanks. The OptiLevel tank gauging system is the best choice for your above and underground storage facilities.
The OptiLevel tank gauging system can be used for all applications in petroleum and petrochemical installations.
The state of the art HLS 3010HF level sensor and designed system architecture enable open interfacing to the Entis Inventory systems and other protocols. |
|
Capacitive level sensors:
Level threshold switch for border who collection and similar level probe to continuous measuring of liquid level.
Level threshold switch with PNP exit, level probes with similar 4-20mA exit, for liquids and fine-grained or pulvrigen bulks. Electrical fitting with plug or cable connection, thread G1/2 ", materials high-grade steel, PVC, PVDF.
With level threshold switch normally open contact of the opener function, with level probe
4-20mA exit, TEACH IN, with exchangeable or shortenable sensor staff for the variable collection of the level height, with protective pipe for medium calming.
Nutsetter also for very viscous media such as e.g. frame of greases, for oils, emulsions, cooling lubricants, water and waste water, dredges, Diesel, granulates, for aggressive media such as acids and caustic solutions.
Applications in plants and mechanical engineering, process and process engineering, water and sewage engineering, environmental technology, automotive industry, chemistry and pharmaceutical one, |
|
Fully insulated, capacitive rod electrode for level measuring
For use in conductive liquids
All advantages in an overview:
- robust and maintenance-free
- easy installation and mounting
- measurement along the complete probe length
- insulation thickness 2 mm
- instrument from the plics® family
Version rod: - fully insulated
Insulation: PE, PTFE
Length: 0.1 ... 6 m
Process fitting: thread from G¾A
Process temperature: -50 ... +200 °C
Process pressure: -1 ... +64 bar (-100 ... +6400 kPa) |
|
The SC700 series are capacitance point level switches ideal for detection or control of liquids, solids, heavy pastes or slurries. Unlike other capacitance probes, the SC700 works for any type of conductive, non-conductive or low dielectric materials with extremely accurate performance, almost complete immunity from build up, temperature changes or condensation. The rigid rod is made with a strong and durable plastic (polyacethal delrin) for standard units or upon request the rod can be made with PTFE.
Features
*Simple to install & low in cost
*No moving parts-maintenance free reliability
*AC, DC or a Universal power supply specification version
*Extended versions available with rigid rod or cable
*Operating temperatures 14 to 200ºF (-10 to 95ºC)
*Maximum pressure of 725PSI (50 bar) up to 8000PSI upon request.
*Sensitivity as well as Time Delay adjustments
*Does not require an external reference in plastic or concrete vessels
*Available in threaded, sanitary and flanged process connections
*3A approved |
|
Combined Niveau-und thermometric bulb made of high-grade steel:
Remarks:
- Level 4-20mA and temperature 4-20mA
- Level float switch manufacturers with integrated thermal relay
- Level 4-20mA with integrated thermal relay
- Level float switch with integrated PT100
- Level 4-20mA with integrated PT100 |
|
"Nivotemp 63 K + KN, 63 K-VA + KN-VA
Modern production facilities employ more and more plant automation systems and computerized controls. These allow the monitoring and control of hydraulic and lubricating systems. Traditional level controls are focused on pump protection i. e. a typical system is equipped with a level switching with one or two contacts. These contacts protect the pump from running dry in the event of leakage..
Modern systems provide the opportunity for a pro-active leakage control by the use of continuous signals.
An analog output of 4-20 mA signals continuous signals the fluid level. Deviations from the ""normal"" are detected instantly and can be transformed into many types of action. In case of a catastrophic failure such as a burst hose the pump could be shut down immediately rather then let it run until the traditional switch turns it off after a large volume of oil has spilt.
The Nivotemp 63 versions provide continuous analog signals for liquid level only or for level and temperature combined. They are available in two standard length or in 150mm increments. The flange dimensions are the standard ones used for filler/breathers ( DIN 24557/2). In addition the units can be combined with our Fluidcontrolterminal which makes oil care even more technically advanced.
The 63..VA versions are suitable for use with high water based liquids ( HFA).
easy, cost effective installation
continous level / temperature control
4-20 mA analogue outputs
flange standard
one cable for two functions" |
|
|