| GE TRANQUELL® surge arresters are designed to protect against overvoltages such as lightning or switching. Intermediate class arresters are used in electric utility and industrial substations to protect transformers and other substation equipment from lightning and switching surge generated overvoltages. Tranquell® polymer arresters provide both excellent protective characteristics and temporary overvoltage capability. |
|
| We offer an extensive range of products designed for use in distribution and transmission networks, qualified to IEC and ANSI standards. We supply polymeric and porcelain surge arresters for distribution and transmission networks. The Energy Division has 30 years of service experience of our composite products and in long-term service, our products have an outstanding record for reliability and performance, in the toughest environments and applications. |
|
Application - Miniature circuit breakers ETIMAT DC are
used for protection of conductors in direct current
electric circuits. 1-pole circuit breakers are used for
voltages up to 220 V d.c.
and for higher voltages (up to 440 V d.c.) 2-pole circuit
breakers with poles connected in a series.
When connecting the MCB ETIMAT DC man must pay
attention to polarity.
If connected in a wrong way, the MCB can be destroyed.
You cannot use two 1-pole MCBs instead of one 2-pole MCB. |
|
Q-Line Miniature Circuit Breakers
15 to 100A. THQB and THQC types. Available in bolt-on and Cable-in Cable-out (lug-lug) versions.
E2000 Miniature Circuit Breakers
0.5 to 63A. These miniature circuit breakers offer superior supplemental overload and short circuit protection. The E2000 line has two levels of interruption capacity, 6 kAIC and 10 kAIC. |
|
The product is used for protecting overload and short-circuits in the system. The circuit breakers are with tripping characteristics type C and offers short-circuit response of 5 - 10 In normal rated current, making it suitable for most domestic/small building protection applications.
- Rated Voltage: 230/400V
- Number of poles: 1,2,3,4
- Rated Current: 2 to 63A
- Breaking capacity: 6 and 10kA
- Standards: BDS EN60898
- IP rating: IP?20 |
|
For today's customers building machines for use throughout the world, the new Bulletin 1489 helps with compliance for the varied circuit protection requirements. The Bulletin 1489 line is listed for branch circuit applications in the United States and Canada and approved as a miniature circuit breaker for IEC applications.
Designed to meet North American and IEC standards the 1489 product line provides a variety of configurations with current ranges of 0.5 A to 40 A and voltage ranges of 240V AC and 480Y/277V AC. The 1489 circuit breakers also have a DC rating: 1-pole 48V DC and 2-pole 96V DC series. This versatility can reduce engineering costs, save time for OEMs, panel builders and end users and can help meet safety standards.
In North America, the Bulletin 1489 meets UL 489 and CSA 22.2 No. 5.1 standards for branch circuit protection as well as IEC 60 947-2 requirements for miniature circuit breakers used in international industrial applications. To address the needs of equipment protection that are installed in electrical control panels, the new device helps with the equipment protection circuit formally only associated with UL 1077. It provides users with circuit protection from 0.5 amps to 40 amps and up to 480 volts.
For ease of installation a series of 1489 busbars (80 A) are now available, certified to UL489. These busbars are available in: single phase, two phase, and three phase versions.
As circuit protection standards evolve to meet application demands, Bulletin 1489 gives users a safer, reliable option that protects personnel, equipment and facilities from electrical hazards. |
|
| The "Record Plus" family of circuit breakers has been developed as a line of aesthetically and technically coordinated protection devices for LV distribution and control applications. |
|
Low voltage moulded case circuit breakers are used for the switching and protection of power supply cables, motors
and other electrical equipment against overloads and short circuit faults. It provides, beside protection function other
functions as remote ON/OFF operation, undervoltage protection, main switch, ...
They are available in range from 16 A up to1600 A in 3 and 4 pole versions.
Advantages:
- Small dimensions,modular sizes
- Possibility of field-instalable accessories - up to 630 AF series 2
- High short circuit breaking capacity (up to 100 kA)
- Fast break mechanism (F.B.M.)
- Reduced energy let throught I2t - minimises thermal stresses
- Reduced tripping time - minimises damage after fault
- Reduced peak short current ampacity - minimised electrodynamic stresses on conductors and
protected equipment
- Installation on mounting plate, 125 AF also on DIN-rail
- Wide range of accessories
- Compact design with high mechanical strenght
- High withstand voltages (8 kV a.c.)
- Voltage level up to 690 V a.c. and 250 V d.c. - only MCCB's with thermal-magnetic triping unit
- Direct opening - recommendation according to standard IEC 60204-1 - up to 630 AF series 2
- Common internal accessories - up to 630 AF series 2
- Visual safety
- Unsurpassed flexibility |
|
Record Plus™ Thermal Magnetic Trip
3 to 100A. The FC100 and FB100 Record Plus breakers provide a new standard of performance offering multiple levels of interruption capacities, global code approvals, compact size, dual AC/DC ratings, and a broad range of accessories.
Record Plus™ Electronic Trip
125 to 600A. The FG600 Record Plus breaker offers the highest short circuit ratings in the industry, all in a traditional 400A frame.
Spectra RMS™ Electronic Trip
15 to 1200A. These industrial SE150, SF250, SG600 and SK1200 breakers have a digital, solid state, RMS sensing trip system with field installable, front-mounted rating plugs to establish or change the breaker ampere rating.
Thermal Magnetic
15 to 1200A. Our industrial thermal magnetic E150, F225, J600 and K1200 breakers provide a proven, cost effective solution.
Mag-Break® Motor Circuit Protector
Magnetic only circuit breakers. Available in frame types E, F, J, K, and Tri-Break.
Lighting Circuit Breakers
15 to 100A. TEY breakers available with plug-in or bolt-on mounting options. |
|
RCCB Record Plus: FD63/160 frame size
Rated at 160A, the FD63/160 frame size is designed for use in both a DIN-rail environment with modular equipment and in industrial applications. It is supplied with IPXXB terminals suitable for direct connection of one or two conductors totalling up to 95 mm² and is available as a thermal-magnetic breaker, a moulded case switch, and as a magnetic-only motor circuit protector.
The FD63/160 bridges the gap between residential miniature circuit breakers and industrial moulded case circuit breakers.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI
3 and 4 pole versions available
FD63 to 63A and FD160 to 160A
Full range of add-on accessories, including:
thermal magnetic/magnetic trip units
auxiliary contacts
completely integrated add-on devices available
rotary handles
electrical operators
connectivity - 60 mm system
|
|
Molded Case Circuit Breaker
- 2, 3 and 4 poles from 5 to 1.600A
- Rated voltage 750V
- Rated breaking capacity up to 150kA
- Interchangeable unit of electronic regulation
- New SUSOL range |
|
The market-leading Modular Control System (MCS) offers you more freedom to configure load feeder solutions through 1200 A. MCS load feeder components provide the following control and protection functions:
- Disconnecting means
- Short-circuit protection
- Load switching
- Motor overload protection
- Status indication and signaling
- DeviceNet communications |
|
Circuit-Breakers for Motor Protection Series 8523/8
Explosion protection to
CENELEC
IEC
Can be used in Zone 1 and Zone 2
Optional equipment
auxiliary circuit switch 1 NC + 1 NO or 2 NC + 2 NO
under voltage trip
hunt trip (open-circuit trip)
Switch operation with knop
Secure switching
Clear switch setting indicator
Different current setting ranges |
|
Let one device save your enormous fortune!! ARS-08 series is a perfect solution for up to 8 loops protection.To keep telecommunication devices from damage by lightning. Its module design provides a flexibility to apply to PBX, server room, telecom exchange room, offices, and etc.
The arrester leads the surge energy to ground and can be automatic recovered. It can withstand max. 6KV10/700ìs lightning attacks. The repeated protection feature is perfect to be applied in lightning frequent environment. It is conformed to ANSI C62.45, IEC61000-4-5 and IEEE62.41 Class B2, which ensures the quality of this product series. |
|
Features:
For TT Single-phase Systems
Iimp = 50kA
Imax = 100kA
High Energy MOV and GDT
Compact Housing
Product summary:
The PROBLOC BS(R) 100 (1+1) series of over voltage surge protective devices has been developed to protect against partial direct and indirect lightning discharges and is intended to provide protection in zones 0A - 1 as per IEC 62305. The (1 1) range is intended to be used on TT single phase networks, where N to PE galvanic isolation is required. The circuit topology consists of one varistor stage protected by two thermal disconnection devices. Each unit comprises two high performance varistor blocks. A high energy encapsulated air gap (GDT) provides galvanic separation between the N and PE conductors. |
|
ETITEC over voltage arresters are intended for protection of electrical installations and devices against overvoltage
effects, which may occur in atmospheric discharges and switching overvoltages. The main part of overvoltage arrester
is ZnO non - linear varistor. Its main characteristic is ohmic non-linearity, which depends strongly on the applied
voltage at the clamps. All arresters have modular construction, a special feature is interchanging varistor part and
visual signalization for varistor thermical failure. The signalization is made with red flag, which appeares when failure
occurs. The models with RC mark equipped with auxiliary contacts for signalization. |
|
| GE TRANQUELL® surge arresters are designed to protect against overvoltages such as lightning or switching. Station class arresters are used in large electric utility and industrial substations to protect transformers and other substation equipment from lightning and switching surge generated overvoltages. Tranquell® Station arresters provide both excellent protective characteristics and temporary overvoltage capability and are available in both Polymer and Porcelain Housing configurations. |
|
| The quarter wave stub devices feature best in class performance specifications, including bi-directional protection, low VSWR, normal and reverse polarity, high RF power and ultra low let through(5V). Using robust materials in construction the maintenance free quarter wave serier is ruggedized, weatherproof to IP68 standard. |
|
| Replaceable Gast Tube models are designed for maximum durability in extreme conditions. Typically rated at an astounding IP68 rating these units are ready for any environment, and more critically - will last the test of time. |
|
Residual current circuit breakers EFI are used for protection against indirect touching of parts under voltage, for
prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation
and for protection against direct contacts of parts under voltage in case of I < 30mA. Residual current circuit breakers
can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective
conductor are separated (VDE 0100 Teil 410).
Types - Our programme comprises residual current circuit breakers which are sensitive to alternating residual current
(AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type). |
|
The Scimitar range has been built to meet stringent requirements and is corrosion resistant for durable outdoor and indoor use.
The switches are contained within a common stainless steel SF6 filled tank with the fuses mounted in air above the gas chamber. Each fuse is sealed against external influences and locked into its own chamber upon insertion. The units can be extensible for direct connection to form multiple plan switchboards without the need to access the gas chambers or for extra cabling.
Features
Ratings up to 15.5kV
Common switching chamber with sealed SF6 environment
Low gas operating pressure
Fully extensible
Indoor and outdoor
Freestanding, transformer mounted or transformer connected |
|
The DS215 Type 2 surge protectors are compact devices designed to protect single phase networks at the main switchboard.
DS215 are available for 230V or 120V AC network and the different distribution systems (TN, TT, IT).
Easy and fast maintenance
Compact single phase surge protector
In = 5 kA
Imax = 15 kA
Common mode or Common/Differential mode protection
Pluggable module
Remote signaling contact (option )
In compliance with NF EN 61643-411 and IEC 61643-1 |
|
ZS-CAT5/CL :
Version designed to protect one terminal connected to a 100BaseT "Category 5" network. Shielded enclosure equipped with in/out RJ45 connectors. All the 8 wires are protected.
These surge protectors for remote terminals are used in association with a multiline rack surge protection (PL24-CAT5/CL) centralized protection at the hub level. |
|
The modular lightning protectors of type OF ensure the protection of the electric systems against overpressures being able to appear on their feeding circuit per (effect of the lightning), or of operation stormy weather of coupling on the network (industrial parasites).
Protection is ensured thanks to a spark-gap strong capacity of flow, able to run out with the ground a current of 150 kA without suffering damage.
This module associated with models DGV, makes it possible to constitute a very effective protection in mode common mode differential according to the wiring diagram "C2" of guide UTE 15-443 (still called "3 1").
The lightning protector OF is used for protection upstream of the networks single-phase currents or three-phase particularly exposed (lightning protector of the type 1). It is installed with the TGBT of the installation. It is exclusively intended to be cabled between neutral (NR) and ground (EP) in partnership with lightning protectors DGV, connected to them-even between phase and neutral.
|
|
The PROTEC BS(R) 25 series of low cost, over voltage surge protective devices has been developed to protect against partial direct and indirect lightning discharges and is intended to provide protection in zones 0A - 1 as per IEC 62305. It consists of two separate, high performance dual MOV blocks, each with a separate disconnection device.
Category IEC/EN/VDE: Class I / Type 1 / B+C
Location of use: Main distribution boards
Protection modes: L/N - PE, L - PEN
Protective element: High Energy MOV
High surge discharge ratings: Iimp = 25kA, Imax = 100kA
Internal protection and safety: Separate thermal disconnector for each MOV block
Status indication: Mechanical flag + remote contacts (R)
|
|
|
|