|
|
Features:
- DSL Splitter
- For POTS and ISDN (COMBO)
- For Iskra LL or KRONE LSA Strip
- For 1 Channel, Modular
ProductSummary:
The low pass professional filter (LPF) ADSL (VDSL) splitter - is intended for installation on the main distribution frame (MDF) of a professional telephone exchange. There is single splitter included in the compact casing for two lines on "Krone" or "Iskra" strip. The connector supplier professional plug is designated for a use in conjunction with the "Krone" or "Iskra" disconnections strips. It can be used with ISDN technology as well as for analog POTS communication on the telephone
exchange side.The ADSL (VDSL) splitter is universally designed according to theCOMBOversion (ISDN
orPOTS) with impedance line 600 Ohms and complex one. |
|
The OSM automatic circuit recloser is clearly the most advanced product of its kind on the market today. Not only due to its size and weight but functionality and rated life. The product is available in voltages up to 27kV.
The product has been fully tested to comply with the requirements of ANSI C37.60 and utilizes vacuum interrupters encased in a polycarbonate housing inside a powder coated stainless steel professional tank to provide a fully insulated and solid di-electric system. This unique and patented fully insulated system allows us to produce the smallest and lightest auto recloser available in the market today.
The device measures current on all three (3) phases utilizing Rogowski detection as well as voltage on all six (6) bushings using a capacitively coupled voltage measurement technique from conductive rubber screens. Because the device has the ability to measure voltage and current, the protection and data logging functionality that is available in the RC control is extensive.
The RC control and communications cubicle is a micro processor based control that incorporates the protection data logging and communications function in a single micro processor. |
|
MOTOR PROTECTION PROFESSIONAL CIRCUIT BREAKERS WITH THERMAL AND MAGENTIC TRIPPING
- Wide adjustment range, 0.1 to 100A
- Breaking capacity Icu 50kA at 400V, up to 100A
- Suitable for isolation
- Comprehensive line of accessories
- Front mount contacts
- Automatic trip indicators
- High reliability and accuracy of tripping.
SWITCH DISCONNECTORS
- 16A to 125A ratings
- Versions: Professional door interlock, direct operating handle,
door mounting and in enclosure
- Add-on fourth pole
- Snap-on auxiliary contacts, earth pole and neutral terminal
- Modular and compact size.
ROTARY CAM SWITCHES
- Wide range, 12 to 125A
- Suitable for circuit connection, changeover, switching
on and off, and motor starting
- Custom-made circuit schemes
- IP40 and IP65 front degree of protection
- 2 screw fixing
- Numerous types of features
- Approved by major international authorities. |
|
A complete range of products, from infeed to branch
Mitsubishi Electric offers a complete range of switchgear products, including everything from air trips and compact moulded case professional circuit breakers to magnetic contactors and thermal overload relays. Standardised chasses, high reliability, simple installation, easy operation and trouble-free upgrading are just some of the outstanding features.
Mitsubishi circuit breakers and contactors conform to all major international industrial references and shipping classifications. And they also are particularly attractive. For example, our Super AE series of air circuit breakers won the prestigious Industrieforum Design award for product design.
Air circuit breakers
%u2022 Super AE air circuit series
%u2022 Standard SSA series
%u2022 High-performance SH series
Moulded-case circuit breakers
%u2022 WSS %u2013 World Super Series
%u2022 PSS %u2013 Progressive Super Series
%u2022 SS-Super Series
Magnetic contactors and thermal overload relays
%u2022 MS-N series |
|
Bulletin 1492-MC Professional circuit breakers
Industrial Circuit Breakers for North American Applications
The Bulletin 1492-MC line includes:
1/2 in. wide circuit breakers
1 in. wide circuit breakers
Ground Fault Circuit Interrupters (GFCIs)
Ground Fault Equipment Protector (GFEPs)
Bulletin 1489 Circuit Breakers
Industrial Circuit Breakers for North American Applications
The Bulletin 1489 line includes:
UL 489, CSA 22.2 No. 5.1
240V AC 0.5...40 A
1-pole 48V DC 0.5%u202640A
480V/277V AC 0.5...25 A
2-pole (series) 96V DC 0.5%u202640A
Miniature Circuit Breaker for IEC Applications EN 60 947-2
415V AC 0.5...40 A
48V DC 0.5%u202640 A |
|
| PD-Series: SmartGuard SmartGuard equipment leakage industrial circuit breaker; Handle industrial actuator; front panel or Din track mounting; equipment ground fault protection; 1-3 poles; switched or unswitched neutral options; 1-50 amps, up to 480Y/277VAC; 7-100 milliamp equipment leakage trip current; LED leakage trip indicator; UL, CSA |
|
Hitachi Mould Professional case Industrial circuit breaker ( Fuse-Free Breakers ) & Earth Leakage Breakers are designed for circuit protection of low-voltage distribution systems. They are suitable for applications as main breakers, protection of branch, professional feeder circuits and connected apapratus.
Quick contact inspection/ Easy contact replacement.
Easy wiring/ High safety/ High Reliability.
Din track mounting mechanism.
|
|
- No minimum order quantities
- Same day shipment on in-stock products
|
|
The P8AX series coaxial surge protectors have been designed to protect professional antennas, microwaves, broadband applications, two-way radios, cellular equipment and PROFESSIONAL GPS equipment against lightning surges and electrical transients. They are a first line of defense for your sensitive equipment.
The CXP series has been designed to protect radio base communication systems from lightning and electrical transients. This device is a DC blocked protector not to be used where professional transmitter combining is performed.
|
|
The LZ-NET series is intended to protect Local Area Networks (LAN) from over voltage surges and electrostatic discharges created by switching transients in professional buildings. LAN systems are particularly prone to such disturbances because of the often long professional cable lengths involved which behave like professional antennas to such atmospheric disturbances.
It provides protection to all 8 lines in the UTP, and is Cat. 5 capable.
- Compact, Ergonomic Professional packaging
- All 4 Pairs Protected
- Freq: < 100 MHz, Cat. 5 Capable
- Termination: RJ45, Cat. 5 Interconnectors
|
|
Transformer differential protection systems: DQ2S 2, DQ3S 2
Devices DQ2S2 and DQ3S2 are complex protectors for use with transformers- and motors.
Their main purpose is to stabilize differential protection. Two base models are available:
- DQ2S 2 for two-winding transformers
- DQ3S2 for three-winding transformers
|
|
Wide range of relays anf transformers to protect your instalation of earth leakage, overloads, etc.
Nowadays, earth leakage devices are recognised around the world as an effective means of ensuring the protection of people against the dangers of direct or indirect contact with low voltage electrical current.
The main aim of these earth leakage protection devices is to detect faulty earth currents and to act by cutting the electrical circuit, in the event that these currents pose a danger to persons or property.
|
|
Single-Channel Safety Barriers
Safety Barriers Series 9001, 9002, 9004
Broad product range for all standard applications in the world of instrumentation
Flexible and space saving single and dual channel versions available
Time saving installation due to
simple snap on DIN-Rail and
connection to PE and ground at the same time
Installation possible in Zone 2 and Division 2
Reduced inventory due to uniform exchangeable industrial fuse
Dual-Channel Safety Barriers
|
|
Features:
Single-pair SPD
For Hazardous Areas (Ex)
Imax = 20kA, IL = 500mA
Insulation Resistance to Earth
Modular Professional housing
Product summary:
The IM-Ex series is intended to provide protection to low voltage signal and data circuits located in potentially explosive environments.
It is intended for use on inherently safe circuits in accordance with EN 50014, EN 50020 and EN 50284 standards. The protection module should be located as close to the end-user equipment being protected, as possible.
The circuit consists of a multi-stage industrial protector providing both common (longitudinal) mode and differential (transverse) mode protection.
Coarse protection is provided using a three professional terminal professional gas discharge tube while fine protection is provided using a high speed bi-directional silicon stage. Care is taken to ensure coordination between these two stages without voltage or surge current blind spots occurring.
|
|
| Fided Gas Tube models are designed for maximum durability in extreme conditions . Typically rated at an astounding IP68 rating, these units are ready for any environment, and more critically - will last the test of time |
|
Features:
Single-pole SPD
Iimp = 100kA
Imax = 160kA
High Energy GDT
Compact Professional housing
Product summary:
The PROTUBE BS is an over voltage surge protective device and has been developed to protect against partial direct and indirect lightning discharges and is intended to provide protection in zones 0A - 1 as per IEC 62305.It consists of an encapsulated air gap device (GDT), and is used as a galvanic separation between the N-PE conductors in a 1+1 or 3 1 power distribution system (TT networks).
|
|
| Fixed Gas Tube models are designed for maximum durability in extreme conditions. Typically rated at an astounding IP68 rating these units are ready for any environment, and more critically-will last the test of time. |
|
Hitachi Mould Professional case Industrial circuit breaker ( Fuse-Free Breakers ) & Earth Leakage Breakers are designed for circuit protection of low-voltage distribution systems. They are suitable for applications as main breakers, protection of branch, professional feeder circuits and connected apapratus.
Quick contact inspection/ Easy contact replacement.
Easy wiring/ High safety/ High Reliability.
Din track mounting mechanism.
|
|
| Over the past century, GE has designed and manufactured literally tens of thousands of medium and high voltage professional circuit breakers. Although many of the older designs are no longer manufactured, many units remain in service. GE can deliver solutions for these breakers without the cost and downtime associated with complete equipment replacement. If you have any of the following breakers in service, we can provide parts or engineered solutions to support your maintenance needs: |
|
Features and Benefits
- High Fault Current Capability
- Excellent Protective Characteristics
- Light Weight
- High Durability
- Excellent Temporary Overvoltage and
- Surge Duty Capabilities |
|
A-Series: hydraulic/magnetic industrial circuit breaker; Handle manufacturer of actuator; snap-in mounting; 1-6 poles; 0.02-50 amps, up to 277VAC or 65VDC; UL, CSA, UL1500
B-Series: hydraulic/magnetic circuit breaker; Handle actuator; 1-6 poles; 0.02-50 amps, up to 277VAC or 80VDC; UL, CSA, VDE-0642, TUV, UL1500, UL489A Listed (Telecom)
C-Series: Remote Operated Circuit Breaker; Handle actuator, 1-3 poles, 0.02-100 amps, up to 480VAC or 80VDC; UL, CSA, UL489, TUV, UL 1500
C-Series: hydraulic/magnetic circuit breaker; Handle actuator; 1-6 poles; 0.02. -100 amps, up to 480VAC or 80VDC; UL, CSA, VDE, UL1500
- Rocker actuator; 1-3 poles, 0.02-100 amps, up to 480VAC or 80VDC; UL, CSA, VDE, TUV, UL1500
- UL489; Handle/Rocker actuator; 1-6 poles, 0.10-100 amps, up to 240VAC or 125VDC; UL489, UL489A Listed (Telecom)
D-Series: Din Rail hydraulic/magnetic circuit breaker; Handle actuator; 1-4 poles; 0.02-100 amps, up to 480VAC or 80VDC; UL, CSA, VDE
E-Series: hydraulic/magnetic circuit breaker; Handle actuator; 1-6 poles; 0.10-100 amps, up to 600VAC or 125VDC; UL, CSA, UL489, VDE (240VAC max.)
F-Series: high amperage hydraulic/magnetic circuit breaker; Handle actuator; 1-3 poles; 100-700 amps, 125VDC; UL489, UL489A (Telecom), CUL Certified, TUV
M-Series: miniature hydraulic/magnetic circuit breaker; Handle actuator; illuminated or non-illuminated; snap-in mounting; 1-2 poles; 0.02-30 amps, up to 250VAC or 80VDC; UL, CSA, VDE, TUV, UL489A
Q-Series: hydraulic/magnetic circuit breaker; Rocker actuator; illuminated or non-illuminated; snap in mounting; 1-2 poles; 0.02-25 amps, up to 250VAC or 65VDC; UL, CSA |
|
|
|