The S1-552 is an advanced 5kV insulation tester with a high output current and many time-saving features. A large, analog/digital LCD shows resistance valves up to 5 T%u03A9 and incorporated a timer and other test information. The output current, of up to 5mA, speeds up testing by charging capacitive loads quickly.
The 5 and 15-kV Megohmmeters are high-voltage, line operated instruments that can be used on all types of insulation tests ranging from 500 volts to 15 kV.
With over twenty 1-kV models to choose from, selecting the proper Megger insulation tester can appear a bewildering task at first. Actually all the process requires is a little organization. All Megger insulation testers perform essentially the same test in fundamentally the same manner %u2014 accurately and reliably. Refinements and added features, however, separate one model from another in application and operator appeal.
|
|
Having both battery and mains operation and four selectable DC test voltages (500V, 1kV, 2.5kV & 5kV), this tester measures insulation resistance. The large, clear analogue scale also displays AC or DC voltage up to 1000V. Latching test switch allows hands free testing.
With full over-voltage and over-current protection for measurements and 8 hours operation from rechargeable Nicad batteries, the E3511 comes in a carry case. Standard accessories include locking 2m test leads with prods and clips. |
|
| Agilent LCR and resistance meters are useful in testing components and materials in a variety of research and design applications and in component manufacturing. LCR meters measure impedance (inductance, capacitance, and resistance) at spot frequencies. Resistance meters are optimized for high-resistance or low-resistance measurements. |
|
1. 320x240 dot-matrix display
2. Test frequency range : 20Hz - 1 MHz
3. Measurement parameter |Z|, Rs, Rp,Xs, Rdc|, |Y|, Gp,
Bp, Ls, Lp, Cs, Cp, D, Q , Theta
4. Basic Accuracy ± 0.1%
5. Measurement Time : 30 mS ( Fast )
6. Bin Function : 8 bins (expandable to 15 bins)
7. Comparator function: Primary / Secondary
8. Memory : 256 instrument setups
9. External Memory interface (Option)
10. Interface : Handler,( Option : GPIB, RS232 ,Printer )
11. Deviation Zero : Open / Short
12. DC Bias (Option) |
|
| The LCR Meter measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use. |
|
Product ID: LCR-612
20000 Counts Hand Held LCR Meter Dual Display Auto-Ranging ( LCR-612 )
20000 Counts LCR Meter
Dual Display Auto-Ranging
MODEL: LCR-612
Outstanding Features:
1.Basic accuracy:
0.5% for Resistance
0.7% for Inductance, Capacitance
2.Dual Displays provide quick tested results readouts, with L.C.R. Display values up to 19999 counts and Q.D.R. display values up to 9999 counts
3.Excellent resolutions:
Resistance up to 0.001Ù
Inductance Capacitance up to 0.1uH/0.1pF
4.Provided up to 4 testing parameters:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
5. Auto-Power Off function:
To conserve battery life for longer use.
6.Fuse detection function:
To inform that the fuse is open or damaged.
7.External DC Adapter functions:
Use of a DC adapter can also serve to disable Auto Power Off function.
Dual Display LCR Meter LCR-612 Test Ranges: 120Hz and 1KH
LCR-612 SPECIFICATIONS
LCR-612 Display:
LCR—4 1/2 digits, maximum reading of 19999.
QDR—4 digits, maximum reading of 9999. (Auto range).
Parameter Measurement:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
Overload: "OL" is display.
Test Frequency: 1KHz and 120Hz.
Range Mode: Auto and Manual.
Auto Power Off:
The meter key switch inactive for more than 5 minutes, press power key to resume operation.
Measurement rate: Approx. 1 time per second, nominal.
Power Requirement: (1). Single standard 9-volt battery.
(NEDA 1604, IEC 6F22 006P) ;(2). External DC Adapter 12Vmim to 15Vmax / 50mA.(optional)
Overload Protection: 0.1A/250V fast below fuse.
Dimensions:192mm(H) x 91mm(W) x 52.5mm(D).
Weight: 365g. (including accessories) |
|
When measuring EMC conducted emissions from the equipment-under-test, (EUT) most standards specify a LISN (or artificial mains V-network) to couple the RF from the cable, and to provide a repeatable impedance at the measured frequencies. All LISN's fully comply with the relevant standards and feature a rigorous, individual calibration.
|
|
Microhmmeter CA 6250
Continuity of grounds; surface and metallization condition; quality of contacts; resistance of cables and windings; heating of motors and transformes
Characteristics:
* Broad measurement range: from 1μΩ to 2,500 Ω
* Accuracy guaranteed: 4-wire measurement method, automatic compensation of spurious voltages
* 3 measurement modes
* "Temperature compensation" function for a comparative result
* Giant back-lit LCD display |
|
From Megger, these highly accurate, easy to operate instruments measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 100 amps covering a multitude of applications that require precise low-resistance measurements.
|
|
| Agilent LCR and resistance meters are useful in testing components and materials in a variety of research and design applications and in component manufacturing. LCR meters measure impedance (inductance, capacitance, and resistance) at spot frequencies. Resistance meters are optimized for high-resistance or low-resistance measurements. |
|
The new, high-precision ohm meters of the PROMET range deliver an adjustable test current of up to 600 A which is independent of the supply voltage.
They utilize the four-wire resistance measurement method, enabling them to meet the most stringgent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee maximum reliability, even for portable use in switching stations and industrial environments.
PROMET ohm meters feature a modern operating concept, an interface to the test systems of the ACTAS product range and an optional remote control unit, making them both flexible and versatile. |
|
QT25 uses a unique method to detect exact PCB short circuit locations and also pinpoint the shorted components/tracks. Ideally PCB tracks are suppose to have zero resistance, but in actual conditions they have small resistance. The exact location of the short is where the instrument reads the lowest value of resistance and this resistance could be detected with a sensitive instrument like QT25, even in power planes.
QT25 can also be used in measuring the contact resistance of switches and relays in its milli-ohm mode.
QT25 is designed to apply a drive voltage of less than 200 millivolts, while detecting shorts in the populated PCBs, so as to avoid turning on the semiconductor devices inside the circuit, which could lead to misleading results.
There is a composite '16 character alpha numeric backlit LCD display' to show the Resistance range selected, Offset indication, Resistance value, and also the Units.
1. 4 wire resistance measurement
2. Back-lit 16 character alpha numeric display
3. Complimenting modulated audio tone
4. Resistor range of 200 milliohms, 2 ohms and 200 ohms.100 micro ohm resolution in 200 milli ohm range
5. Auto offset capability upto 200 ohms
|
|
| MJÖLNER 200 is designed to measure the resistance of circuit breaker contacts, bus-bar joints, contact elements in bus-bars and other high-current links. The product has been designed with safety, ease of use and versatility in mind. With MJÖLNER 200 it is possible to make measurements according to the DualGround™ method. This means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. |
|
Features/Benefits
Increases test throughput
Reduces operator exposure to high voltage
Improves test quality, consistency and repeatability
Enhances end product quality and reliability
Scans up to 48 points with a single compact unit
Rated to 7kVDC or 5kVAC
GPIB/RS232 standard
May be controlled directly by Vitrek Hipot Tester
Available QuickTestTM graphical programming software
|
|
1. Most useful in locating Vcc - Gnd shorts and track shorts in PCBs
2. 3U cPCI / PXI Platform for rugged Environment
3. Hot Swap (Live Insertion / removal)
4. 4 wire resistance measurement
5. Complimenting modulated audio tone
6. Resistor range of 200 milliohms, 2 ohms and 200 ohms.100 micro ohm resolution in 200 milli ohm range
7. Auto offset capability upto 200 ohms
|
|
| ... products without technical information |
| |
|
|