PART # SBS BCT-5000
DC RESISTIVE LOAD BANK (24, 48, & 120 VDC)
The only way to know your industrial cells will perform to specification is to test them regularly. SBS's battery capacity professional testers enable you to test your wet or sealed batteries in a variety of ways and at three voltages. Load bank test 24V, 48V, or 120V DC systems with currents up to 171 amps. A built-in digital meter lets you read volts, amps, amp-hours, and elapsed time without having to professional hook up a separate meter. The professional display is accurate to 1% of full professional scale at the rated voltages. The unit also offers continuous operation, so there's no cool down needed after or between tests. Use the master load control professional switch to instantly apply or remove loads. |
|
- Waveform (Range):Oscillation (up to 4 µF, Vmax 6000 V; 4 µF up to 10 µF, Vmax 4000 V)
- Coupling:up to 800 V rms/16 A for <= 6 s / up to 380 V rms/16 A for continuous operation
- Standards:IEC 60348-14 Amd.1,
- Options:EN 132400
- Required Accessory:Coupling Switch Matrix TC-MIG24, TEMA
|
|
The ST101 Socket Professional tester confirms proper wiring of 110-125 V AC sockets. The display of the ST101 socket tester uses easy-to-read light indicators for wiring results.
The ST102 GFCI socket tester is for 110-125 V AC GFCI breakers. The ST102 tests for proper wiring and operation. Easy-to-read light indicators show any wiring problem. The GFCI circuit trips to confirm tester is working. |
|
| Coupling / Decoupling Networks (CDN) are for testing from 150 kHz - 80 MHz according to the EN 61000-4-6 standard for immunity to conducted disturbance induced by radio frequency fields. As the name implies the CDNs has both coupling and decoupling networks. The coupling network delivers injected RF common mode current disturbance signals through the various conductors to the equipment under test (EUT). The decoupling networks are used insure that the disturbing signals injected on the signal or power line of the EUT by the coupling networks does not interfere with any the auxiliary equipment (AE) connected to the EUT. Each CDN contains integrated direct capacitive coupling along with the high impedance choke for inductive decoupling. |
|
| The B&K Precision Model 889A Synthesized In-Circuit LCR/ESR Meter is a high accuracy test instrument used for measuring inductors, industrial capacitors and resistors with a basic accuracy of 0.2%. Also, with the built-in functions of DC/AC Voltage measurements and Diode/Audible Continuity checks, the Model 889 can not only help engineers and students to understand the characteristic of electronics components but also being an essential tool on any service bench. |
|
The earth resistance from 0.05 to 1200Ohm can be measured without the auxiliary earth spikes. (The Multiple Earthing System.)
- True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
- Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.
- Memory function
Save and display up to 100 measurement data.
- Data hold function / Buzzer function / Back light function
- Compliant with Safety Standards of IEC 61010-1 : CAT.IV 300V Pollution degree2 |
|
Features:
- Earth resistance measurement
- Ground resistivity (Wenner's method)
- High spurious voltage rejection
- Spurious voltage measurement
- 0,01Ohm resolution
- Up to 20KOhm resistance range
- Auto-range
- Alphanumerical display
- Heavy duty equipment
- Automatic interference detection
- Rechargeable accumulator
- Built-in professional printer (optional)
- Direct reading of ground resistivity
- Up to 50m selectable distance
- 4000 readings memory
- RS-232 data output
- IP-54 protection
- CE mark |
|
FULLTEST4058 model was designed from HT ITALIA to performing essential tests in industrial environments on electrical machines devices and partially type-tested assemblies (PTTA) in compliance with EN60204-1 and EN60439-1 respectively.
The meter principally performing Continuity test on potential equalising conductors with >10AAC test current, Insulation Resistance with 500VDC test voltage and Withstanding tests with 1000AC test voltage (for electrical machine devices) and 2500V test voltage (for individual test on PTTA assemblies switchboards).
Withstanding test is performed also in BURN mode with no limits on trip-out current. Discharging Time measures of internal capacitance and on external plugs of device under test complete the list of possible test with this meter.As FULLTEST4050 more advanced model also FULLTEST4058 have a built-in internal professional memory to save all measurement results and a RS-232 Professional pcs interface for directly transfer of saved tests by dedicated Windows professional software.
The model is fitted inside a practical and protected plastic case board with no flammability and a membrane keyboard for rapid selection of functions is included on the frontal panel together a wide custom professional display.
FULLTEST4058 is the ideal solution for any kind of verifier and/or industrial installer to performing easily and rapid test on industrial appliances. |
|
4550
Flying Probe Professional test system
The new 4550 provides a powerful and flexible solution for today's test needs. With its fixtureless environment, the 4550 combines incredible speed with extremely high accuracy probing. Add the ability to perform advanced test techniques and the 4550 becomes the number one choice for both prototype and production test. Using the latest in flying probe hardware technology and innovative software techniques, the 4550 ensures short turnaround times for all applications guaranteeing cost effective test solutions.
• High speed, high accuracy fixtureless test
• Short program development times
• Improved test accessibility
• NetzTest intelligent shorts test
• Up to 1012 additional test channels
• Enhanced optical inspection
• Comprehensive toolkit of test techniques
• Optimization in X, Y and Z planes
• Suite of UUT change tools
• Integral manufacturers of conveyor system
|
|
Earth Testing covers the testing of earth electrodes and the measurement of soil resistivity. The instrument requirements depend on the range of applications.
|
|
| The ground resistance of substations can be measured with two auxiliary electrodes which are put into the ground. To avoid influences from the mains current and its harmonics, this measurement should preferably be carried out with 128 Hz.The high output power of the CPC 100 ensures a high ratio of the signal level to the noise level. Thanks to the signal processor technology, the measuring procedure is very selective and disturbances by ground currents are reduced to a minimum. |
|
Description:
Reads ground resistance down to 0.10Ohm.
- Fully autoranging with data hold to capture readings.
- Convenient alarm and 99-point memory functions.
- Measures up to 30A RMS ground or leakage current.
- Measures currents down to 1mA.
- Accessories included: (1) 9V battery, molded carrying case, test resistance loop. |
|
Features
Programmable Test Current to 40 Amps
50-400Hz Programmable Current Frequency
Local/Computer Programmable
Programmable Resistance Limits
Programmable Test Time Durations
AC Ohmmeter to 10uOhms Resolution
Tests to UL/IEC Specifications
|
|
Proper grounding is absolutely crucial for safe, uninterrupted operation of equipment, and is the most essential component of any ESD/EMI management system. Common tool and equipment problems are largely due to ground and power related issues or excessive noise (EMI) on the ground line.
|
|
Featuring Four Instruments in One
AC Hipot to 7KV
DC Hipot to 10KV
Earth Continuity Testing 1mOhms
Insulation Resistance 65GOhms to 2500V
Arc Detection with usec shutdown
Programmable
IEEE-488.2, RS232 Interfaces
|
|
Features:
- Output voltage up to: 1,5 kV~3 kV ~ 5 kV
- Output current up to: 5 mA / 5 mA / 10 mA
- Digital adjustable chronometer
- Alphanumerical display
- Programmable professional keyboard module
- Light and small professional cabinet
- Leds indicators and audible alarm |
|
- LCD Display 320 x 240
- File Management(Flash Memory Card)
- Test Point Range : 64-2048
- Test Voltage : 50 - 1500VDC(RT-9980H/CH), 50 - 1000VAC(RT-9980H/CH)
- Insulation Test : 500K-1000MOhm(RT-9980 H/CH)
- 4-Wire Rsistance Test : Yes(Option)
- Components Test : Resistor,Diode,Capacitor suppliers(Option)
- Resistor Measurement : 0.1Ohm-20MOhm
- Capacitor Measurement : 100pF-1000uF
- High Quality Relay |
|
Euro-Z 290 A adapter
High resolution and accuracy impedance measurement.
Test current up to 294 A, for testing impedance from 1 mW and Isc up to 400 kA. Euro-Z 290 A adapter is a professional portable test adapter.
In combination with one of the instruments EurotestAT, EurotestXA or Eurotest 61557 it performs high precision line and high precision fault loop impedance measurements. |
|
The multifunctional primary professional test system CPC 100, in combination with the coupling unit CP CU1, is a unique measurement system for: Line impedances and k-factors of overhead lines or power cables, Mutual coupling of parallel lines, Coupling of power lines into signal cables,
Ground impedances of large substations, Step and touch voltages.
The test system offered by OMICRON makes use of frequency shift techniques for accurate measurements regardless of electrical interference. |
|
- LCD Display 128 x 64
- File Management ( Flash Memory Card)
- Test Point Range : 64-2048
- Test Voltage : 50-1500VDC (RT-9651 H / CH )
- Insulation Test : 500K-1000MOhm(RT- 9651H/ CH)
- 4-Wire Rsistance Test : Yes
- Components Test : Resistor,Diode,Capacitor suppliers(Option)
- Resistor Measurement : 0.1Ohm-20MOhm
- Capacitor Measurement : 100pF-1000uF
- High Quality Relay |
|
Increased operating safety, personal protection and reliability of electrical installations are very important factors for everyone in charge of an electrical installation. In addition, there are the requirements for time and cost saving maintenance and repair for both simple control circuits and complex switched mode power supplies in industrial plants and in buildings.
|
|
The ISOM range has confirmed SOCOMEC's position as leader in the field of insulation monitoring.
From the basic Permanent Insulation Monitor (CPI) to complete, upgradeable systems incorporating insulation measurement, fault localisation and monitoring functions, we offer a whole range of solutions suitable for all electrical installations.
We also cover related services, such as audit, training, assistance with commissioning etc.
Application:
All LV/HV industrial or commercial installations.
Original features:
The ISOM ALD590 monitoring unit combines the following products:
- Permanent insulation monitor
- Search signal injector
- Insulation faults central locator
Advantages:
- AMP+ coded pulse measurement principle, ensuring immunity from interference present on the network, caused by electronic equipment (power converts, switching psu, Emc filters)
- Increased readability with a backlit LCD display which is very easy for the user to read
- RS485 communication providing connection to professional monitoring systems (centralised building management, programmable controls, dedicated professional software)
- Easy to fit (DIN format casing, plug-in terminal blocks) |
|
Modular Relay ( 3 modules DIN 17,5 mm) for controlling the insulation resistance in a single/three phase system insulated from earth up to 500 V ac and 48 V dc, with possibility of setting the tripping threshold and fault signalling.
RI-F22 / RI-R22
These devices allow insulation monitoring on earth of electric networks voltage 24÷ 230 Vac.
RI-F48 / RI-R48
The devices allow the insulation monitoring to earth of electric networks in alternate and direct-current till 48 V isolated.
RI-R38
This device allow insulation monitoring on earth of electric networks voltage 24 ÷ 440 Vac.
RI-R11
The devices allow permanent monitoring of insulation of electrical networks in direct-current current isolated on earth.
|
|
The microprocessor based device ISOLMED controls permanently the insulation of the loads connected to the secondary of the transformer with rated voltage 220V.
The QR-MA module controls the insulation of the 24V a.c./d.c. networks for the supply of scialitic (shadow-less) lamps or other utilizers. |
|
METRISO 5000A: analog high-voltage insulation measuring instrument with 4 measuring voltages: 100, 250, 500
and 1000 V (per EN 61 557 part 2) and 1500, 2000, 2500 and 5000 V
METRISO 5000AK: The battery powered METRISO 5000 A is converted into the muscle powered
METRISO 5000AK by replacing the battery module with a crank industrial generator.
- Extensive measuring range: 10 kOhm... 1 TOhm
- Measuring range: 100 kOhm... 100 MOhm (1000 V)
- Measuring voltages: 100 V, 250 V, 500 V, 1000 V, 1500 V, 2000 V, 2500 V, 5000 V
- Measurements to 1000 V per DIN VDE 0413
- Voltage measurement to 2000 V ,
- Concise logarithmic display
- Guard terminal for the elimination of surface current |
|
FEATURES:
1. DIM 571 is a LCD Indicated instruments for insulation (M Ohm), Continuity (OHM) and AC Voltage
2. Three Insulation test voltage (DCV): 250V, 500V, 1,000V.
3. Large LCD display(68 x 34mm)
4. Test Insulation at rated voltate into 1 1mA load
5. 200mA short circuit continuity current.
6. Timer for test functions (3 ~ 5 minutes)
7. Data Hold function
8. Auto power off function
9. Automatic circuit dischage
10. Fuse proection
11. EN61010 CAT III 600V
12. BS 16" Edition |
|
|
|