The future of installation testing is here
The 1650 Series testers verify the safety of electrical installations in domestic, commercial and industrial applications. They can ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364, HD 384 and all relevant local standards. The unique ergonomic design, low weight, and padded neck-strap to free your hands, make operating a Fluke 1650 multifunction tester a pleasure. With easy-to-operate controls and a large display with exceptionally wide viewing angle, it's also comfortable and safe to use. Select from three models: Fluke 1651: Performs all basic installation tests including continuity/insulation/loop impedance and RCD tripping time
Fluke 1652: Also provides RCD tripping current level and RCD auto-testing
Fluke 1653: As Fluke 1652 but with earth resistance and phase sequence measurement. Has internal memory and a PC interface for documentation and reporting
|
|
| Testing of Electricity Metering equipment, takes many different forms. Apart from accuracy and stability, meters must also be tested against interference conducted on the elctricity cables. This can be in the form of impulses generated by lightning events, switching action in the mains network or insulation breakdown. EMC Partner specializes in designing test equipment to meet the international standards for impulse testing of energy meters. IEC61036 and IEC62052 are typical standards for class 1 and 2 metering equipment. |
|
The 3091LD is designed to provide precisely controlled non-linear loads for testing AC power generation equipment such as UPS’s, AC sources, electrical switches and circuit breakers. The ability to simulate high crest factor and variable power factor AC load conditions provides an effective method of testing these and other AC products against real-world conditions and can significantly increase product reliability.
Traditionally, many of these products are tested using resistive load banks. This approach does not simulate real-world conditions such as switching AC inputs found in many AC powered products. This type of conventional testing does not fully exercise the equipment under test (EUT) against worst case operating conditions. High peak currents and low power factor loads can significantly impact the operating characteristics of a UPS or AC power product. Unless properly exercised, product defects may go undetected until a unit is used at a customer site, resulting in costly field returns. |
|
The model 8510 is a cost effective Programmable Electronic DC Load with a high degree of accuracy, great display resolution and a wide operating range of up to 120A or 120V, 600W max. The 8510 is well suited for testing and calibrating DC Power supplies, DC-DC Converters and batteries. Programmability via the RS 232 or optional USB interface makes the units ideal for the use in Automated Test Systems.
# Operates between 0-120VDC, 1mA-120A (600W max)
# High resolution 0.1mA/1mV (range dependent)
# Bright, easy to read display (VFD technology)
# CV/CC/CW/CR operation
# Over-Current/Over-Voltage/Over-Power/Over-Temperature Protected
# RS 232 Interface cable and software included
# Optional USB interface available (order IT-E132)
# Thermostat controlled internal fan
# Battery test capability
# Create complex test sequences without the need of an external PC |
|
The new, electronic loads of the series EL3000A and EL9000A offer, amongst the standard features of electronic loads, some new and interesting functions. Three voltage classes and multiple power classes are rounding the selection up.
The model BFC 2000 even offers a mains backfeed.
- DC input voltage: 0...80V, 0...160V, 0...400V
- Powers: 400W, 2400W, 4800W, 7200W
- Currents up to 600A
- Fan-cooled
- 2U/4U/6U, 19" rack housing for the 2400/4800/7200W variants
- Desktop housing for the 400W models
- Battery test, digital control, impulse generator up to 10kHz
- Pluggable extension cards for CAN/RS232/USB
- Analogue interface |
|
Electronic DC loads for individual test applications
The Zentro-Elektrik product family includes 4 product lines with
power ranging from 200W to 100kW.
To satisfy the requirements of automatic test systems, all models come with the standard analogue (0-10V) interface, or with optional digital inferfaces and the relevant software driver (IEEE488.2 with LabVIEW driver, Rs232, USB, CAN etc.).
The interfaces are bi-directional, i. e. as well as programming the set point values, the actual values can also be monitored.
As well as being high precision, all DC load products from Zentro-Elektrik have outstanding dynamic properties that ensure that These electronic laods provide consistently reliable results, even in extreme test applications. Generous power stage dimensioning, Comprehensive protection and safety equipment make the units extremely robust. |
|
Agilent DC electronic loads provide you with the flexibility to test a wide range of applications from power-supply test to simulation of high-intensity discharge (HID) headlamps. The 16-bit voltage, current and power-measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
|
|
Electromagnetic Inteference (EMI) causes equipment malfunction in many applications. EMI is an increasingly persistant problem anywhere sensitive electronics equipment is used.
Typical issues associated with EMI are equipment lock-ups, random equipment malfunction, data corruption, software and parametric errors along with many others.
|
|
ESD3000 is a light weight, hand-held battery operated tester. The modular construction enables many different test standards to be performed. A broad range of accessories enable testing to many applications for contact discharge, air discharge and indirect discharge.
The easily interchangeable discharge modules (DM) quickly adapt ESD3000 to the specified circuits of a new application. Each new module is automatically identified and the corresponding input screens displayed. Modules contain all the high voltage circuits making ESD3000 the ONLY ESD system capable of fully conforming to different calibration requirements.
Unique in it’s class, ESD3000 is powered by a rechargable battery pack up to 30kV for approximately 8 hours @1Hz discharge repetition. Regular AA batteries can also be used.
Electronic polarity reversal, including alternating poalrity, is provided as standard in all ESD3000 models.
Remote control of ESD3000 test system is possible using the EMC Partner TEMA software package.
|
|
The ESD 3000 is the only 32 kV ESD Simulator which is both battery operated and completely hand-held, eliminating base unit, external power supply, and power supply tether cable associated with other ESD simulators.
Full range of easily interchangeable R-C discharge modules ensures the ESD 3000 meets your changing ESD testing requirements.
Light weight, comfortable ergonomics, easy intuitive single-handed operation, clear back-lit LCD display showing all test parameters, and 10 on-board pre-programmable non-volatile memory locations to store ESD test routines; these are just some of the reasons experienced test technicians and engineers applaud the ESD 3000 as the best ESD simulator available.
The low purchase price, use of standard consumer NiMH AA size rechargeable batteries, and proven reliability make the ESD 3000 easy to justify to management concerned about minimizing operational costs. Yes, it has a pulse counter...
|
|
Hour Meter for Panel Mounting Series 8218
Ammeters and Voltmeters for Panel Mounting Series 8218
Potentiometer for Panel Mounting Series 8218
Preset Pulse Counter for Panel Mounting Series 8214
Time Relay for Panel Mounting Series 8214
|
|
| Self-adjusting fault indicator for system-wide application. Provides clear visual indication of fault path to line crews in the field to help reduce fault-locating time. Automatically adjusts its trip value based on the load current, eliminating the need to specify a trip value. Allows line crews to easily distinguish between temporary and permanent faults. The inrush restraint feature allows coordinated integration with automatic reclosing schemes. Patented Ramp Down Restraint feature prevents false activation after extended circuit outage. Distinct eight-hour temporary fault indication allows line crews to investigate the cause of self-clearing faults and successful trip and reclose operations to improve circuit reliability. |
|
Featuring
RS232, PCL & GPIB Control
AC Hipot to 5KV
DC hipot to 6KV
Insulation Resistance to 10GW
ARC Detection
Ground Continuity to .001W
|
|
| Product quality, output and yield of manufacturing processes can be improved considerably when problems related to static electricity are identified and dealt with effectively. Electrostatic fieldmeters are appropriate measuring tools to simply identify static electricity problems. |
|
Electromagnetic Interference (EMI) is the disruption caused by an electromagnetic field. EMI can cause equipment lock-up, sensor parametric errors, undesirable process variations, erratic response, software errors, and even component damage.
|
|
Simply the best HARMONIC and FLICKER test system available today. HAR1000 does not require expensive and bulky AC sources, it uses a novel technique to provide active compensation of distortion on the national power mains.
Featuring dual analysers, the input and output signal are constantly monitored to ensure compliance. HAR1000 conforms to the latest IEC61000-3-2 Edition 2 but also allows testing to previous standard editions.
HAR1000 can be enhanced with the following accessories.
HAR-EXT1000, three phase system
Adds two further phases to the HAR1000. Simple connection without any hardware modifications mean this powerful extension can be added at any time to an existing single phase system.
HARCS Immunity software
This package can be added to both the single and three phase systems. It extends the system’s emission capability to include power line immunity tests such as harmonic immunity according to IEC61000-4-13, voltage fluctuations according to IEC61000-4-14 and ripple on DC according to IEC61000-4-17.
Adding the EMC Partner PS3, allows testing to IEC61000-4-28 for frequency fluctuations.
|
|
The EN6100-3-2 standard deals with the limitation of harmonic currents injected into the public mains supply system. Meanwhile, the EN6100-3-3 standard addresses the limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with a rated current of over 16A. These two standards, which became a mandatory requirement in Europe in 2001, apply to electrical and electronic equipment that have an input current up to and including 16A per phase and that are intended to be connected to public low-voltage distribution systems, such as supply voltages nominally 230V AC or 415V AC 3 phase.
|
|
The HARMONICS-1000 is a flexible one-box test and measurement equipment for testing and measuring harmonics and flicker on power supply. Because of the new designed amplifier the weight and the price of the HARMONICS-1000 are low.
|
|
The Narda Broadband Field Meter NBM-550 has been designed to measure electromagnetic field strengths in the vicinity of transmitters and industrial equipment, and to evaluate and record the results in the context of human safety standards. Particular attention has been paid to ease of use. The instrument can be operated with one hand by anyone – left-handed or right-handed. The probes are isotropic, i.e. equally sensitive in all directions, so users do not need to worry about the direction the radiation is coming from.
The result data memory holds up to 5000 results along with date and time information. A GPS receiver (option) plugged into the basic unit and connected via USB gives the NBM the capability to store position data for each measurement. Instead of handwritten notes, voice comments can also be recorded. All the data can be uploaded to a PC and managed using the PC software supplied with the instrument. Measurement reports are therefore very easy to generate.
The basic unit and the probes are separately calibrated at the factory. The probe calibration data are stored in an EPROM in the probe itself. The NMB basic unit retrieves this automatically via the intelligent probe interface, and takes it into account in the results. |
|
The TRANSIENT 2000 (TRA2000) family of generators, replicate EMC events that can be observed in the low power distribution system, telecommunication or data lines. TRA2000 generators are available in a number of basic versions which can all be upgraded to give full test capability at a later date.
TRANSIENT 2000 generators can replicate the following phenomena:
ElectroStatic Discharges (ESD), Electric Fast Transients (EFT),Combination Wave, Ring Wave and 10/700 Telecom (SURGE), AC and Impulse Magnetic Fields, AC and DC power line interruptions (DIPS).
With some basic accessories this can be expanded to include;
Common Mode tests (DC to 9kHz), Telecommunication tests 10/700us Balanced & un-balanced, Three Phase Testing to 63A for EFT, SURGE, Ring Wave and Three Phase Testing to 100A Dips & Interrupts.
Available with single or multiple events (ESD, EFT, SURGE, RING, DIPS), EMC Partner TRANSIENT generators can all be upgraded to add further capability when required. Unique in their class, TRANSIENT systems include as standard an internal motor variac to enable Dips and Variation tests, at any user programmable level, as per IEC 61000-4-11. |
|
Impulse Voltage Test System - For the generation of high voltage lightning and switching impulses according to IEC 60060 for indoor and outdoor use.
Including:
- impulse voltage generator
- charging and control unit
- control and measuring system
- chopping gaps
|
|
Electric power lines and telecommunication lines often occupy parallel routes as a result of the utilisation of joint facilities or sharing a common right-of-way. Direct contact with electrical mains power can occur through networks line cable faults. The contact may not cause opening of a power system circuit breaker. A.C. current resulting from direct contact may make effective protection difficult. EMC Partner have a range of products designed to meet the ITU-T K44, ITU-T K20 and ITU-T K21 requirements for both power CONTACT and power INDUCTION testing.
MIG-ITU-K44 is a stand alone system that delivers up to 1,600V for enhanced level testing. NW-K44PC can provide up to 600V to meet basic levels.
Additional accessories enable power contact testing at 230V up to 20A per line. |
|
The fast, one-handed tool for loop checks in Ex zones
The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas.The ecom 707Ex is certified in accordance with the ATEX directive (Ex II 2 G EEx ia IIC T4)in Zones 1 and 2.The 707Ex is also certified to operate in accordance with Factory Mutual N.I.Class 1, Division 2 areas Group A-D.
- Large display and simple,,quick-click push
rotary button for easy one-handed operation.
- Simultaneous mA and %%readout for
quick,easy,interpretation of readings.
- mA accuracy of 0.015%%
- 1 µA resolution for mA source,simulate and measure.
- Push button with 25%%steps for fast, easy linearity checks.
- 0--100%"span check ” for fast confirmation of zero and span.
- Internal loop supply,,so you can power and read a transmitter at the same time without carrying a DMM.
Measures V dc to 28 V..0--20 mA or 4-20 mA default start up modes. HART ® compatible resistance is connected in series with the loop supply for compatibility with HART communicators.
|
|
Current loops Kalibrator UPS III IS
Intrinsically safe current loops the Kalibrator UPS III Is appropriate for the industrial employment in highly combustible environment (ATEX II 2G ex ib IIC T4). The UPS III Is the ideal tool to the examination and adjustment of transducers, process control systems and other devices in the process industry. It can measure and give within the range 0 to 24 mA river actively and passively. With the "autostep" and "autoramps" - the user of measured values can let functions give even fully automatic in stages or continuously, without holding the equipment thereby in the hand.
Characteristics:
* ATEX/International Electronical Commission intrinsically safe
* simultaneously river fairs and giving 0-24 mA
* Accuracy: 0.015%
* Stress measurement to 50 VDC
* AUTOCSTEP (valve), AUTORAMP, QUICKSPAN
* Double announcement of mA and %
* Continuity check to 50 V
* large diagram display
* light and robust housing
* Hart® communication (insertable 220 W burden) |
|
EMC Partner offer a range of test equipment to cover the indirect lightning effect tests as defined in documents; RTCA/DO160 and EUROCAE/ED14.
The MIG0600SS, MIG0600MS, MIG0618SS and MIG-OS-MB generators are designed to carry out Pin injection(PIN), Single Stroke(SS), Multiple Stroke(MS) and Multiple Burst(MB) with five different waveforms;
6,4/70 µs (WF1), 0,1/6,4 µs (WF2), 1MHz & 10MHz damped sine (WF3), 6,4/70 µs (WF4), 40/120 µs (WF5A) and 50/500 µs (WF5B).
Multiple Stroke patterns are available with fixed or randon spacing to meet all current requirements including Airbus ABD0100-1-2, Boeing D6-16050-5C and many more.
Avionics test systems include all necessary couplers for PIN injection, Cable induction and Ground injection.
A basic level 3 package comprises the MIG0600MS and MIG-OS-MB geenrators. These can be extended to full level 5 capability by addition of the MIG0618SS and MIG-OS-MB-EXT. MIG-OS-MB-EXT also enables testing with additional waveforms such as 6H or customer specific waveforms.
|
|
MIG2000-6 is a versatile generator capable of delivering impulses to meet MIL-STD-461F including the CS115, CS116 and CS106 requirements. Further modules are available which extend the system to include MIL-STD-1275B for military vehicles, Airbus AMD-24C for the A400M and A350XWB, DO160 sections 17 and 19 and the EFA4 pulses for the Eurofighter typhoon II.
The system is complete and includes all equipment including couplers to perform testing on cable bundles using either series or parallel injection.
A reliable and flexible test system, MIG2000-6 is in use at many facilities worldwide. |
|
Testers for lightning tests on telecommunication equipment based on the following standards or recommendations: ITU-T, IEC, Bellcore and FCC.
|
|
Precision Locate
The RD4000 family of precision buried service locator delivers precision location of underground services even in difficult and congested areas whether marking, surveying or mapping.
Radiodetection's RD4000 range of precision locators and transmitters are the industry standard for mapping and locating underground utilities across a broad range of industries. |
|
|
|