Casing: supple for ventilation and heating
Induction Casing: smoke, dust, waste, cuttings, sugar, cereal, powders |
|
| The shutters in aluminum to shovels contrapposte of the Rafidamp series are, today, how much better the market of the regulation and calibration of the air can offer, in fact, to taken care of an assemblage of the members joins great quality of the raw materials and performances of absolute relief, without, naturally, neglecting of the competitiveness, essential member on the today's markets. |
|
Range of ten turrets of désemfumage allowing to cover a beach of flow from 500 to 27.000 m3/h for a pressure of 200 Pa. Horizontal or vertical repression. Behavior with the 2 hour old fire to 400°C. Galvanized steel compartment integrating the electric accessories (box of relayage, pressure controller and switch of proximity). Hat in ABS. For tertiary buildings (ERP, IGH, commercial premises or industrialists) and collective habitat.
FEATURES
Dimensions (Ø X H): 57 X 50,9 to 100 X 100 cm.
Weight: 19 to 156 kg.
Power supply: single-phase current 230 V/50-60 Hz or three-phase current 400 V/60 Hz.
Power engine: 0,24 to 4 kw.
Index IP55.
Implementation: pose in outside on terrace or directly on conduit.
Accessories: tally to seal, axis pivot, non-return valve, stock terrace, tallies on conduit, variator of tension and frequency.
Option: precabling. |
|
| VMC double flow, functioning with new air or heat recovered on extracted air. Tight cast solid power station equipped with ventilators two speeds for blowing and extraction of air (thermodynamic modules). Two motorized modules of regulation, self-adjustable mouths of extractions, mouths of blowing with connection in plenum. Order electronic mural skeletal. Connected together by conduits of circulation and conduit of recycling. For house and multifamily apartments. |
|
Cast solid power station of VMC with recuperator of heat and purifier of air adapted to the tertiary buildings. Function in flows crossed with an exchanger high output (90%) with against-flow, aluminum plates ensuring the transfer of heat of the extracted air vitiated the new insufflated air, by conduction. Engine low consumption with electronic switching equipment ensuring the precision of the regulation and piloting. Adjustment on case of order off-set with screen LCD. Junction box in frontage. Night Surventilation ensured by motorized by-pass.
FEATURES
Programming by motorized by-pass.
Flow: 450 to 4.000 m3/h.
Implementation: junction box in frontage; maintenance of the filters. |
|
| Aluminium honeycomb vent panels for EMC screening in a range of styles and sizes. Steel honeycomb vents are also available. |
|
• HIGH LEVEL OF EMI/RFI SUPPRESSION COMBINED
TO PASSAGE OF AIR IN SHIELDED ENCLOSURES
• ALUMINIUM HONEYCOMB FOR HIGHEST AIRFLOW OF
ANY VENT MEDIUM (LOW STATIC PRESSURE DROP)
• ALUMINIUM WIRE SCREEN SANDWICHED BETWEEN
RIGID EXPANDED MESHES FOR DUST ARRESTING
(INLET COOLING PANELS)
• FURNISHED READY TO INSTALL WITH STANDARD
ALUMINIUM FRAME AND EMI SHIELDING GASKET
(fastener or thru-holes on the frame for fixing) |
|
| ATI's brass and steel honeycomb vent panels are recommended when structural integrity, H-Field shielding effectiveness, harsh environmental conditions and durability are primary concerns. Brass or steel extrusions are customized to surround brass or steel honeycomb and welded in place. Continuous flow soldering provides enhanced contact between the honeycomb and frame improving integrity. Alco Multi-Gasket, a combination of neoprene sponge and monel mesh fit, most applications although Alco-Knit or conductive gaskets are available. Standard through holes and spacing for surface mounting installation is customized. Vents without gasketing can be welded in place. Brass vents are typically finished with tin lead plating. Steel vents are commonly finished with tin plating. Other plating options available. Ideal for mobile military transportation, communication shelters or equipment where EMP or TEMPEST is required. |
|
| Leader Tech introduces its high performance EMI shielded air vent panels to its product range. Air vent panels are manufactured using aluminum, steel or brass and are available in various plating finishes and mounting configurations allowing for installation in most applications. |
|
Metex EMI vent panels provide maximum attenuation with minimal air-flow resistance. Shielding effectiveness is greater than 80 dB at 10 MHz for chromate finished, single layer honeycomb, and is increased to 105 dB using our cross cell construction. By selecting the appropriate frame style, finish, and gasket type, performance can be custom tuned to meet your shielding requirements, and your budget constraints.
Vent panels are constructed of aluminum alloy honeycomb, with a perimeter frame of aluminum extrusion for mounting and gasket application. Various gasket options include wire mesh, spring finger, or conductive fabrics |
|
| Spira’s family of exceptional honeycomb filters includes our NEW Shielded Fan Filter, as well as our popular Econo-Cell, Spira-Cell, and Brass-Cell Shielded Air Vent Filters. All Spira honeycomb filters include the “Spira Advantage” as described on our website. |
|
Suction and blower hoses for temperatures from -20 °C up to +280 °C, DN 40 up to DN 900
Applications:
extraction af gaseous media: air conditioning and ventilation industry, suction plants, ventilation and suction, welding fume extraction (with increased spark concentration), tent heating, in areas with raised safety requirements, low pressure applications
Properties:
- highly flexible
- compressible
- small bend radius
- external steel helix protects against abrasion
Connecting elements:
- hose clamps
- hose connectors
- hose reducers
|
|
Ventilation system modulated for the tertiary buildings consisting in automatically ventilating the buildings according to their occupation, thus reducing the thermal losses all while maintaining the quality of the air. Order by three types of detection: of presence (Presence), activity (Agito) or CO2 rate (CO2). Piloting of a ventilator for the buildings ventilated by a specific ventilator or of a terminal (TDA) or modulates (MDA) for the buildings served by a branch of a network. Adapted to the meeting rooms, offices, buildings of teaching, cinemas, etc
FEATURES
Technical opinion n° 14/04-864. |
|
Designed to retract the hose with the assistant of an electrical high-torque motor.
We recommend this reel for truck service shop applications where hose and nozzles can be heavy and overhead cranes have to move. |
|
Oil Vent is a single wall vent connector and is designed to make connections between appliance and common vent such as masonary chimney, or z-flex liner products both easy and economical.
|
|
Range of mouths of extraction covering with the air flows from 15 to 60 m3/h and the whole of the Bi-flows for kitchen and medical. Composed of a technical turntable, a regulator and a white hermetic PVC hull with partly high slit and removable frontage being able to be painted. Available without barrel for the restoration (four modes of fixing) or with barrel 125 mm in diameter in new installation. Declined in standard model mono-flow or Bi-flow and model with manual, electric regulator flexible time-lag or electric ON/OFF, limited to 160 m3/h in peak output.
FEATURES
Air flow: 15 20 30 45 or 60 m3/h (medical); 20 75,30/90,45/105 to 135 m3/h (Bi-flow cooks).
Dimensions stops medical (L X.X p): 154 X 162 X 91 or 94 mm (with or without barrel).
Dimensions stops kitchen (L X.X p): 168 X 225 X 95 or 101 mm (with or without barrel).
Diameters was Ø: 100,116 or 125 Misters.
Color: white.
Aeraulic operating range: 50 to 160 Pa.
Implementation: mural fixing by fitment (with barrel of Ø 125 mm in nine) with sealing and plating ensured by joint (Roll' in); adaptation on all existing connections by rigid conduit, flexible connection (RT Flex), male cuff or with shoulder, by screwing or clipsage. |
|
ASD-150, ASD-200 Stainless Steel Ventilator
304 Stainless Steel
Dimensions: 150 X 40 mm, 200 X 50 mm
1.5 mm diameter holes
Application: Various
Finish: Satin (Stainless Steel)
Please visit our website for further information about this and other similar products.
|
|
| ATI-Thin Filter is the thinnest profile EMI shielded air filter. Extruded aluminum surrounds a singular thin piece of expanded monel or aluminum metal screen and welded in place. Alco-Knit or conductive gasket increase shielding effectiveness. Through hole locations are customized for easy surface mount installation. Plating options enhance shielding effectiveness. ATI- Thin Filters are frequently placed at intake and exhaust areas and are best utilized where narrow space limitations are a requirement. |
|
Gigalam Panel
Gigalam panel filters are combination products specially developed for mini-environment and process tool applications. An ULPA filter using standard glass media, low boron media or PTFE is combined with single or multiple layers of Gigapleat media.
Sizes are custom made to suit specific pieces of process equipment. The compact form of Camfil Farr Gigalam filters means that often they may be installed in the same space as the original particle filter.
The Camfil Farr Gigalam features:
- Extremely small form factor - often the same as for particle filtration only.
- Choice of standard, low boron or PTFE particle media.
- Choice of different Gigapleat media.
- Low pressure drop.
- High media cleanliness.
SEMATECH recommends the use of e-PTFE or low boron ULPA filters in mini-environment equipment. Camfil Farr's Gigalam can be manufactured with an overall height less than 4". Customized solutions are also available. |
|
GVR : Ventilation grille
Application :
ventilation of cereals, oil seeds : wheat, rape seed...
conservation of food products : potatoes, onions... |
|
Description
Systemair TSO square perforated ceiling diffuser, with PER plenum box as an accessory. The TSO can be shielded with the SSO accessory.
Accessories
Ceiling plate (600x600) TPP
Shielding SSO
Plenum box PER with removable damper and test points
Function
The TSO is a supply and exhaust air diffuser designed for ceiling assembly. The TSO has a perforated front plate and a connection sleeve fitted with a rubber seal tested for airtightness. The TSO has high induction which allows a maximum air temperature difference of dT 10 K. The distribution pattern can be altered with the SSO shielding accessory to one-, two- or three-way distribution. The distribution unit is adjustable. |
|
Pipe fitting of ventilation ensuring aeraulic continuity between the column of origin and the mouth. Composed of a metal connection female, an extensible flexible device aluminum, an end and a plastic cuff of connection to the mouth and maintenance in the plasterboard (13, 15 or 18 mm). Dismountable solution for maintenance. For prickings and the mouths 125 mms in diameter. Proposed in two beaches from length, 10 to 30 cm or 30 to 120 cm.
FEATURES
Dimensions (Ø X L): 12,5 X 10 to 30 cm; 12,5 X 30 to 120 cm. |
|
Assembly in dihedron:
In the case of important flows, the cells type 16 and KNOWN thickness 38 and 50 mm can be gone up in dihedrons. Frontal surfaces are then reduced in a ratio from 3 to 1. The cells type 16 equipping the dihedrons are provided with handles (contrary to the cells KNOWN cut-rate version).
Dihedrons MIOFILTRE are superimposed easily to constitute "plates support" or "boxes". |
|
| ... products without technical information |
| |
|
|