Liquid crystal modulation ellipsometer
Provides classical ellipsometric data and the full 16-element Mueller Matrix
Enhanced application capability for the characterization of depolarizing and anisotropic samples
Modular Design
Competitive Price
|
|
The OP1100 Discontinuity Analyzer is an off-the-shelf fiber optic test System that automatically captures, displays and logs short optical power interruptions and spikes in the accordance with EIA/TIA-FOTP-32A
This test solution provides a method for testing a broad variety of passive or active fiber optic components for susceptibility to discontinuities (single dropout, transient output or transmittance fluctuations) during application of an external stimulus, such as temperature, vibration or physical shock.
|
|
Flexible Fused Silica Capillary Tubing
TSP: Characteristics
- Standard Polyimide Coating
- Synthetic Fused Silica
- 100% proof tested at 100kpsi**
- Operation up to 350°C
TSG: Characteristics
- High Temperature Polyimide Coating
- Synthetic Fused Silica
- 100% proof tested at 100kpsi**
- Operation up to 400°C
TSU: Characteristics
- UV Transparent Coating
- Synthetic Fused Silica
- Operation up to 160°C
** Tensile Strength
Custom Sizes & Coatings Available
|
|
Gloss Meter PICOGLOSS 562 MC
The two-angle gloss meter with the measuring geometries 20°/60° is one of the smallest portable gloss measuring instruments which have ever been designed. The measuring geometries 20°/60° and the automatic change-over of mirror-gloss meet the requirements of the mostly used gloss ranges i. e. high and medium gloss. The PICOGLOSS 562 MC is provided with an automatic calibration as well as extremely long-life LEDs as light sources and a USB interface. The instrument is operated by two round cells the capacity of which is sufficient for at least 10,000 measurements.
Measuring ranges 20° mode:
0 - 150 and 150 - 1999 GU, respectively.
Measuring ranges 60° mode:
0 -150 and 150 -1000 GU, respectively
|
|
|
Small, portable gloss measuring device with universal 60° measuring geometry and mirror-gloss switch-over. The PicoGloss 560 requires only one calibration standard for calibration. LC display for convenient display of measuring and calibration values and further messages. An USB port is available for data transfer to a PC. Free download of PC software. The Picogloss operates on a micro battery for up to 10,000 measurements (in PC mode via USB port). The PicoGloss 560 MC comes in a carrying case including a high-gloss standard, micro battery, USB cable, lens cloth, and operating instructions.
|
|
Multigloss 268
The Multigloss 268 is an ultra compact portable Gloss Meter with three measuring angles in full accordance with ISO, ASTM, DIN, BS and JIS norms. With only two operation keys, all functions such as language settings, calibration, measurement and statistics can be performed. With the three angles 20°, 60° and 85° all kind of glossy surfaces, from mat to high gloss, can be measured. For perfect production control up to 999 measurements are stored and used for statistical calculations.
|
|
|
Small portable meters to measure gloss at 20, 60 and 85 degrees. Ideal for a variety of applications including paints, plastics, films, furniture, and auto parts
|
|
|
The sensors of RLS-GD series are used for online measurement of gloss degree. In the production of plastic sheets (design sheets, wall coverings, floor coverings, table coatings, foam sheets, and coated carrier materials for the furniture industry, automobile industry, fashion industry, or construction industry) and ceramic parts (ceramic tiles and plates for wall and floor) 100% quality inspection of the optically visible surface has become an ever more frequent requirement.'
|
|
|
The Multigloss 268 is an ultra compact portable Gloss Meter with three measuring angles in full accordance with ISO, ASTM, DIN, BS and JIS norms. With only two operation keys, all functions such as language settings, calibration, measurement and statistics can be performed. With the three angles 20°, 60° and 85° all kind of glossy surfaces, from mat to high gloss, can be measured. For perfect production control up to 999 measurements are stored and used for statistical calculations.
|
|
|
|
|
|
The first micro-gloss became the industry standard in gloss measurement. The new micro-gloss combines the well known ease-of-use and protected calibration in the holder with a new and unique functionality - designed for today`s QC standards.
the micro-gloss is always ready, including calibration holder. Small as a digital camera - it is safe in your hand. Thanks to a well structured menu and a new scroll wheel the operation is easier than ever before.
The calibration standard is always protected and exactly positioned in the holder. New: the intelligent auto diagnosis tells you when to calibrate and even checks whether the standard is clean. Operator friendly. Safe.
With the new micro-gloss you can measure any material - paints, plastics or highly reflective metals.
Its new expanded measurement range of up to 2000 gloss units guarantees always reliable results - according to international standards.
The long-term stable light source and patented illumination control provide superior accuracy for many years. Lamp changes will no longer be needed. We even give you a
10 year guarantee on the lamp life.
|
|
Small Digital Hand-Held Refractometer:
For easy and accurate quality control A. KRÜSS Optronic have launched their New DR201-95, a handy refractometer for use in the food, beverage pharmaceutical, and petrochemical industries. This model has a wide range (0 – 95% Brix) and fits in every pocket. The user can select between different scales and the device has an automatic shut-off after 30 seconds. Calibration is simple with water and the instrument has an automatic temperature compensation to ensure that concentration readings of liquid solutions will be accurate as regards to the sample temperature.
Measurement Range: 1.3330-1.5318 nD; 0-95% Brix
Power Supply: 1,5V Battery
Scale Division: 0.0001 nD; 0.1% Brix
Accuracy: 0.0003 nD; 0.2% Brix
Temperature Compensation: 5-40°C
More handheld digital refractometers on our website.
|
|
|
|
|
|
Pursuing the "easy-to-use" and "easy-to-understand" ergonomic architecture of this new instrument, the achieved result was not only a "palm fitting" design but also a unit with highly hygienic properties. By reducing the number of unnecessary assembly parts such as the grip, we cut down the risks of creating a germ reproductive enviroment.Though our effort to pursue a germ-free unit, it is unavoidable for an instrument to have grooves between each component and shutting completely the way for germs to spread, so we have come up with new concept of making it a completely washable unit. Moreover, it is equipped with the E.L.I. function, which makes the measurement more reliable in bright light area.
PAL-1 : Brix 0.0 - 53.0%
PAL-2 : Brix 45.0 - 93.0%
PAL-3 : Brix 0.0 - 93.0%
PAL-alpha : Brix 0.0 - 85.0%
PAL-RI : nD 1.3306 - 1.5284
Special PAL-series are available for more than 80 scales, covering almost all applications.
Main features are
1.Extremely water resistant(IP65). Easy cleaning by
runnning water.
2.E.L.I.(External Light Interference)
3.A.T.C.(Automatic Temperature Compensation)
4.Calibration with water. Don't need to use Standard liquid.
5.Light & Compact 100g
6.Equipped with a strap holde
7.Ergonomically designed for one-handed operation
|
|
• fast application and easy-to-use operating control
• universal and mobile measurements
• mains-independent operation ( approx. 10 000 measurements)
• no need for sample cells
• integrated temperature measurement and compensation
• infrared interface
• data storage
• automatic quality observation of measurements
The compact hand-held polarimeter HP100 for measuring the optical activity of soluble substances. When simultaneously applying the built-in temperature sensor the read-out will show the temperature-compensated results e.g. optical rotation [°], sugar scale [°]Z and concentration [g/100ml].
The read-out is shown on a graphic display, the measurement unit is selected over a clearly arranged keypad. Average determination possible.
The infrared interface of the hand-held enables the stored measurement results to be transmitted to a PC for further processing.
Operation modes are both by battery or power supply, switching is automatic.
|
|
This is a precision instrument for determining the solid contens dissolved in liquids, such as sugar, salt, or serum protein in blood and starch. A few drops of the sample is palced on the refractometer prism and the index of the refraction is measured. From this, dissolved solids can be determined in seconds.
Specifications and tables of comparison on our Website
Compare products of this class:
|
|
MASTER-α(#2311)
This new type of Hand-Held refractometer is the first to be equipped with Automatic Temperature Compensation and Water Resistant (IP65) at the same time. While featuring functions such as Easy-to-Read, Easy-to-Hold, Smooth sampling, Easy disposal of sample from the edge, the improvement of hygiene aspect by employing the new type of grip, and well balanced structure, emphasis is also placed on its design, well exemplified by the streamlined body and the strong grip with rich texture.
Measurement range : Brix 0.0 - 32.0%
MASTER-T(#2312)
This is the successor model to the conventional ATC-1E.
Automatic Temperature Compensation feature only. The Master-T is a good alternative choice when the water resistant feature is not a priority.
Measurement range : Brix 0.0 - 32.0%
MASTER-M(#2313)
This is the successor model to the conventional ATC-1E.
No ATC and Water resistant(IP65).
Measurement range : Brix 0.0 - 32.0%
|
|
|
Depending on the measuring range and application, Bellingham Stanley Ltd offer a choice of instruments to suit all budgets. The range includes IP65 sealed 'Eclipse models' and digital refractometers.
|
|
|
|
|
|
The latest generation of Konica Minolta lux meters, the T-10, replaces the globally successful models of the T-1 series. The small, easy-to-use handheld meters are capable of measuring intermittent light sources, can be connected to each other to form multi-point units, and are easily controlled with a PC. They have an extremely large measuring range of 0.01 to 299,000 1x with automatic range switching, and a large, backlight LCD. And all of that with Konica Minolta's renowned high level of precision in a small, compact design.
Areas of application
Konica Minolta lux meters are used whenever brightness and the quantity of ambient light must be measured. Even the measurement of average values and illumination is possible. Examples of their use include the measurement of workplace and street illumination, the production of lamps, as well as architectural, forestry, and agricultural applications. Deployment in hard-to-reach spaces and under water are possible, just as the metering of very large surfaces and projectors (ANSI lumens) by serial connection of several receptor heads. Metered values can also be visualized graphically and even fully automated by using the PC software.
|
|
|
Measurements of diameters without contact. The haloes present in a Petri dish can be sized with this device only by pushing the reset button in one edge of the spot and moving the holder to the opposite edge of the halo. The display shows the diameter with an accuracy of 0.1 mm.
|
|
|
Lapmaster International's SPI Interferometers with grazing incidence are an inexpensive, fast and accurate means for flatness inspection of ground, fine-ground, lapped or polished parts. The flatness reading of a non-reflective ground surfaces (most materials) are clearly displayed as fringe-pattern topography on an accompanying monitor. Eliminate the need for secondary polishing operations when the only purpose is to generate a reflective finish for optical flatness measurement. Whether used directly next to the lapping, fine-grinding, grinding machine or inspection lab, the Lapmaster SPI interferometer is a cost-effective solution for simple flatness qualification requirements. An optional printer provides documentation of the flatness readings. This instrument is an excellent platform for both qualitative (go/no-go) as well as quantitative flatness measurements.
|
|
The ESPI system from Steinbichler Optotechnik is an extremely flexible instrument for deformation and vibration analysis. One of its most important features is that the system can be adapted to the customer´s specific demands and applications.
By using the wave character of laserlight, even small deformations can be detected with an accuracy of 0.05 µm. The deformation is measured either one-dimensionally (typ. out-of-plane) or spatially (in- and out-of-plane) with a 3D-unit which is optionally available.
In the vibration analysis, e.g., resonance frequencies and vibration modes of excited parts can be determined fast and precisely. Innovative developments such as the "Free Boundary" and the "Sine Stepping/Universal File" functions significantly improve the handling of the measurement system.
|
|
|
For over 30 years Ophir has met the challenge to consistently provide accurate and reliable laser power and energy measurement devices. Now Ophir welcomes Spiricon- world leader in laser beam profile measurement, providing solutions for the widest possible range of beam profiling applications. By combining forces, Ophir-Spiricon now leads the industry in all aspects of laser beam measurement. Ophir- Spiricon provides a line of silicon cameras, along with exclusive Pyrocam pyroelectric cameras, which allow profiling and analysis of both pulsed and CW beams, with powers from µW to Watts.
|
|
3 microns to 44 mm beam dimensions
190 nm to 4 µm wavelength options
Measure in confined spaces
Linear and log profiles to see energy at the edge of the beam
Linear scanning slit meets ISO 11146 Standard
55 dB dynamic range (= 300,000 : 1)
M2 measurements repeatable to 0.2% (with optional 2D stage)
23 x 45 mm scanned area (with optional 2D stage)
|
|
|
The UP12E family was designed for portability. It is an excellent choice for field service or small beam OEM applications. The low profile stand alone detector measures a few mW to 10 W and to 20 W with its heatsink. Water cooling takes it to 70 W of continuous power. That is great for embedding in machines and immunity from environmental fluctuations. Great performance in a package as little as 14 mm deep!
|
|
The XLE4 – eXtreme Low Energy Detector
eXtreme Low Energy measurement: this is what the XLE4 stands for. From nJ’s to mJ’s, the XLE4 offers accurate NIST measurements in all conditions. It is a nice complement to our series of QE energy detectors to read even lower energies.
Low Noise Level
The XLE4 low noise equivalent energy of 30 nJ with an amplifier or 150 nJ with a SOLO sets it apart from the competition. This pyroelectric detector thus extends in the nJ’s the measurement range of QE series joulemeters. Its high sensitivity of 1100 V/J makes it ideal for measurement in noisy laser environments.
kHz Repetition Rate
The metallic coating of the XLE4 makes it an excellent choice for pulsed lasers up to 2000 Hz. It can detect pulses of duration up to 5 µs. Moreover, it can be used with many different types of lasers due to its broad spectral range.
|
|
|
The Power Wizard™ power meter from Synrad offers a unique solution to the measurement of laser power and serves as a service tool to ensure maximum laser performance at any time. Designed to measure power levels from 1-250W, the PW-250 provides accurate measurement of average laser power, which is displayed on an easy-to-read LCD screen.
|
|
The QPM Family
Gentec-EO’s QPM Series is a fully automatic laser power probe that calculates laser power by measuring temperature dynamics using a microprocessor. Its measurement and acquisition technique determines the time needed to carry out a measurement. Data acquisition is triggered and stopped by detecting set heat parameter thresholds. This technique is virtually error free and allows for multiple measurements without absorber forced cooling.
Power Range
Six models cover the full-scale powers from 500 mW to 10 kW. Their innovative measurement concept cuts the time to measure and display down to ten seconds on all probe models providing:
# Excellent accuracy (± 3 to 4%)
# Repeatability (± 1 to 2%)
# High resolution
|
|
|
|
|
|
General description :
Coherent offers the broadest line of laser power meters and laser energy meters available anywhere. In addition, as the world's leading producer of laser systems, we thoroughly understand the practical requirements and challenges of using laser measurement tools. This puts Coherent in a unique position to configure a laser measurement system that provides the right combination of performance, features and cost for your particular needs. The modularity of the Coherent system also ensures that your investment will be protected as your needs evolve or change.
Our standard product line consists of four types of meters:
- Laser Power Meters
- Laser Energy Meters
- Laser Power and Energy Meters
- OEM Power and Energy Modules
Power-only and energy-only meters offer simplicity and economy. However, certain advanced capabilities are only available in dual (power and energy) meters, so these products should be considered, even if your use is purely for a single measurement type (power or energy).
|
|
The module VE0006 is a system for the evaluation of luminous objects in the visible area of the light. For this purpose, colour and luminosity are evaluated independently, according to user-specific instructions. Thus, the module is especially qualified for the function test or the qualitative selection of LEDs.
Technical data:
- Test parameters color and intensity
- Power supply 12-30V DC
- Wavelength 400nm up to 700nm
- gain steps 6
- Resolution 12 bit for each gain
- dynamic >90 dB
- Serial and parallel interface useable in parallel
- Cycle time approx. 23ms for 1 product
|
|
|
|
|
|
The LED-Station is a cost-effective system solution for testing LEDs. The system is based on the mini-array spectrometer MAS 40 and is designed for determining the light radiation from LEDs. Different adapters can be attached to the robust input flange of the MAS 40, enabling measurement of both luminous intensity and luminous flux. From a single measurement of the spectrum, additional spectral parameters such as the color coordinates, the color temperature or the dominant wavelength can be calculated. The MAS 40 can additionally be expanded through attachment of a mini goniophotometer for determining the spatial radiation pattern of LEDs. The LED-720 constant current source (50 mA max.),ideally suited to driving standard and high-brightness LEDs, completes the LED-Station. All components of the LED-Station correspond to Instrument Systems stringent requirements on quality and performance, and are calibrated together with the spectrometer before shipment.
Features:
- a complete solution for LED measurements (tests luminous intensity [cd], luminous flux [lm], chromaticity values and spatial radiation pattern)
- cost-effective and robust CCD spectrometer technology
- all Instrument Systems test adapters can be used
- SpecWin Light software as well as DLLs und LabVIEW drivers
- current source ideally suited for driving LEDs
Applications:
- Quality control and incoming inspection of LEDs
|
|
The LX 100 is a hand-held luxmeter for workstations, offices, sport installations, parking, commercial centers….dedicated to control and monitoring illuminance.
- From 0,1 to 150 000 lux (from 0,01 to 13940 fc)
- Illuminance for local measurements
- With timed measurement : min., max., average values.
LX 100 includes a pause function to eliminate any unrepresentative and unwanted illuminance or display a local result. It allows a relative measurement to a reference point for the quantification of increase illuminance or decrease illuminance.
The LX100 is supplied with calibration certificate.
|
|
|
|