| Coen's worldwide approved, state-of-the-art iScan flame detector features an "All In One" configuration with an integrated viewing head and signal processor, which eliminates the traditional flame professional scanner signal processing unit (professional amplifier) and amplifier professional cabinet. The iScan is accepted as the industry standard for monitoring oil, gas, and coal flames with thousands of units in use worldwide. |
|
Dräger Safety optical flame detection provide the reliable detection of a wide range of both hydrocarbon and non-hydrocarbon based fires. Providing a perfect solution to the ever increasing demand of flame detection throughout industry, they can also be used along with Dräger supplier of gas detection technologies to form part a complete safety system
The reliability and flexibility of Dräger flame detectors, along with their worldwide approvals ensure suitability for just about any application anywhere in the world.
|
|
The Model FL3111HT is a high temperature rated (125°C) ultraviolet (UV) optical flame sensor designed to detect unwanted fires while maintaining false alarm immunity. The FL3111HT detects only in the UV spectral range for optimized speed of response.
The FL3111HT's electronics are integral within its stainless steel explosion-proof housing, allowing detector information to be processed at the point of detection. The electronics are fully separated from the Exe wire compartment offering protection during installation and service. |
|
Flame detector for continuous operation IFW 50
Flame detector for flame signalling or for multi-flame control in conjunction with IFD 450/454, for continuous operation, ionisation control.
Mains voltage: switchable from 220/240 V AC to 110/120 V AC, for earthed or unearthed mains.
Flame detector IFW 15
Flame detector for flame signalling or for multi-flame control in conjunction with IFS 110/111IM, for intermittent operation, ionisation or UV control. For earthed or unearthed mains, mains voltage:110/120 V AC or 220/240 V AC.
Flame detection PFF
Flame detector in 19" standard rack for multi-flame control in conjunction with PFS/PFD or for flame signalling.
PFF 704: for intermittent operation, ionisation or UV control,
PFF 754: for continuous operation, ionisation control,
with 4 independent flame professional amplifiers,
mains voltage: switchable from 220/240 V AC to 110/120 V AC, for earthed or unearthed mains.
|
|
| The extensive line of ANSUL® Foam Products includes premium foam concentrates for both Class A and B fires, proportioning equipment for various system arrangements, and an array of discharge devices to cover your application. And you can look to our experts for both products and design assistance. |
|
The Variacor® system, internationally patented, makes all rigid hosing flexible and multi-directional, whatever may be the pressure.
-Increases pliability of fire professional hose, less effort due to hose rigidity,
-Makes easier using fire hose in hard to access area,
-Reduces step backwards when handling fire hose.
|
|
DICTATOR manufactures electromagnets tested and approved according to the EN 1155:2005.
An extensive product range of electromagnets and professional counter plates
covering most applications.
Holding forces up to 5000N
Voltage: Standard 24 VDC, other tensions also possible
Special designs
- Ex-proof industrial magnets
- IP65
- Magnets with UV-resistant sealing resin for outside applications
- Magnets to be integrated in overhead industrial door closers
- Customized designs
|
|
Material generally linked to a fire system which will automatically release the industrial fire doors in case of a fire, by switching the power off.
Electromagnetic holder mounted in a metallic box painted with white epoxy, with cabled local release button, protection level IP42, delivered with an equipped magnetic pin |
|
Bullard offers the most comprehensive line of thermal imagers and accessories in the fire industry.
As with any other capital expenditure, fire departments should expect their thermal imagers to provide years of reliable service. Making the best product selection should not only involve a careful evaluation of products on the market, but it should also consider the service and support that a department will receive before and after the sale.
|
|
| Air purifying suppliers of respirators use cartridges or canisters constructed of carbon or paper-based professional filters to remove contaminants or particles from non-IDLH (Immediately Dangerous to Life and Health) environments. Air purifying respirators that rely on the user's inhalation to draw the ambient air over the filters are called negative pressure air purifying respirators. Those that utilize professional blower to pull the ambient air through the filters and then push it to the user are called positive pressure air purifying respirators. Air-purifying respirators have numerous applications from construction and automotive repair to pharmaceutical and oil production. |
|
| With the fire detection system PYROVIEW/PYROSOFT WBFDS DIAS Infrared GmbH, VdS certified manufacturer of infrared vision sensors, offers you a complete system for supervision of your plants. Certified infrared professional cameras PYROVIEW are the heart of the automatic fire detection system. Infrared cameras PYROVIEW are based on state-of-the-art microbolometer arrays with up to 384 x 288 pixel and are well suited for industrial use with their robust housings and optional cooling and air purge systems. |
|
The automated early fire detection system WASTE-SCAN is based on the principle of infrared thermography. It provides a continuous, non-contact temperature measurement at the surface of a waste collection, even over large distances.
Main item of the system is the high-resolution thermographic professional camera VarioCAM® hr head manufactured by the German company JENOPTIK Professional laser, Optik, Systeme GmbH. It is based on an uncooled microbolometer detector FPA.
The thermographic camera VarioCAM® hr head has the following performance parameters:
(384 x 288) or (640 x 480) pixels for high geometrical resolution
high-contrast, low-noise thermal image
localisation of hot spots, even under dusty or smokey conditions
spectral range (7.5 ... 14) µm
real-time professional data acquisition at 50 / 60 Hz frame rate
internal automatic calibration. |
|
The self-checking SAFYR PACKSCAN flame detectors are designed for monitoring solid or liquid fuel industrial burners (oil, pulverised coal, heavy liquid residues). They are adapted for multi-burner installations by facilitating flame discrimination.
A binary safety signal is transmitted in the presence or absence of a flame. The output signal is also available on terminals for recording or remote display purposes.
Operation of the SAFYR PACKSCAN flame detector is based on the characteristic flickering phenomena of flames, generally between 0 to 150HZ. It uses a silicium photodiode cell, adapted to the combustion frequency in the visible light band (320 to 1100nm).
A display indicates all the configured parameters, as well as the detection level.
30 years of experience in the field of flame detection gives the SAFYR PACKSCAN the following advantages :
• An ‘all in one concept’ with an integrated professional amplifier in the professional scanner head for easy installation.
• Two microprocessors for increased safety and reliability.
• Approved by APAVE to meet all safety criteria requirements
• Detection level indicator to simplify commissioning
• Various standard confi guration methods by internal switches, by remote and by serial link, to simplify configuration
• Two SPDT output switches to indicate flame presence and proper detector operation |
|
The Model FL3100 is an Ultraviolet / Infrared flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects fires by monitoring in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. There is also a hydrogen-specific detector available that detects hydrogen fires.
FL3100 Series flame sensors' electronics are integral within their explosion-proof housings, allowing detector information to be processed at the point of detection. The detectors also provide a 4-20mA stepped output signal indicating detector status. The COPM (Continuous Optical Path Monitoring) self-test feature checks the optical path integrity (window cleanliness) and the detectors' electronic circuitry once every minute. |
|
The design of this new generation of detectors provides 3 main features :
• Performances
• Guaranteed detection
• Easy installation, use and maintenance.
The efficiency of SIMTRONICS flame detectors offers :
• High sensitivity,
• Very short response time,
• Reliability,
• Immunity from interferences
It also guarantees protection against fire risks in industrial environments and enables the control of fire fighting.
The housings are treated specifically to resist corrosive factors (stainless steel or aluminium housings).
These TV63 UV / 2xIR detectors have a wide viewing angle (110°) and a range higher than 45 m.
The integrated relays and a 4-20mA output enable the control of the TV63 by the control units or by PLC.
The detectors are equipped with an automatic test control, which regularly checks the functionality of detection, as well as the optical and electronic integrity of the system.
The detector’s non-stop auto-tests & intrinsic quality feature SIL 2. |
|
| The Model FL4000 is an advanced multi-spectral infrared (MSIR) flame detector designed to provide superior false alarm immunity with the widest field of view. The FL4000 employs a multi-spectral optical IR sensing array with a sophisticated Neural Network Technology (NNT) system to reliably discriminate between actual flames and the vast majority of false alarm sources (such as arc soldering). The FL4000 is designed to detect typical fires such as alcohol, n-heptane, gasoline, jet fuels and hydrocarbons. In addition, the FL4000 can see through dense smoke produced by diesel, rubber, plastics and lube oil fires. |
|
The design of this new generation of detectors provides 3 main features :
• Performances
• Guaranteed detection
• Easy installation, use and maintenance.
The efficiency of SIMTRONICS flame sensors offers :
• High sensitivity,
• Very short response time,
• Reliability,
• Immunity from interferences
It also guarantees protection against fire risks in industrial environments and enables the control of fire fighting.
The housings are treated specifically to resist corrosive factors (stainless steel or aluminium housings).
These TV63 detectors have a wide viewing angle (110°) and a range higher than 85 m.
The integrated relays and a 4-20mA output enable the control of the TV63 by the control units or by MANUFACTURERS OF PLC.
The detectors are equipped with an automatic test control, which regularly checks the functionality of detection, as well as the optical and electronic integrity of the system.
The detector’s non-stop auto-tests & intrinsic quality feature SIL 2.
|
|
Nitrogen fire-fighting plants are designed for extinguishing fires caused by inflammation of various flammable substances which can only burn in the presence of air, such as oil, oil products, or gas condensate, in enclosed volumes and premises, as well as for the prevention of fire and explosion hazardous situations at oil and gas producing enterprises.
The operating principle of a nitrogen fire-fighting plant is based on inert properties of the resulting air mixture with 95–99% nitrogen concentration. With this level of nitrogen concentration, burning process is rendered impossible. Gaseous nitrogen produced by membrane gas separation unit of a nitrogen fire-fighting plant is forced into a receiver which capacity is calculated based on the volumes of premises and vessels to be fire-protected by the plant.
In case of fire, nitrogen delivery into the fire-affected volume starts automatically. This ensures quick and reliable fire extinguishing without damaging equipment or injuring personnel. Furthermore, nitrogen fire-fighting plant is designed so as to allow the use of nitrogen generated for purging process vessels simultaneously with automatic replenishing of its reserves.
Nitrogen fire fighting has a number of objective advantages associated with the plant structural simplicity, serviceability, and high cost-effectiveness.
Summary Specification
Nitrogen parameters at the plant output
–Nitrogen purity, % 95–99.9
–Output capacity, nm³/hr* 10–1000
–Pressure, g. atm. 5–15
–Dew point, °С −40…−60
Ambient temperature
–during operation, °С −50…+40
–during storage, °С -60…+50
Warm-up period, max., min. 10
Membrane modules useful life (capacity reduction by 10%): 130-180 thousand hours
* Capacity is referenced to normal operating conditions (t=20° C, P=1 atm.)
|
|
URR
The URR water supplier of nozzle produces a pressurized water spray which canbe continuously adjusted from a powerful straight jet, to a 160° round water curtain with a 11 meter (36 feet) diameter.
Please note the capacity changes in these two extreme operating conditions.
A strong rubber ring circles the diameter immediately behind the orifice, to avoid damages due to shocks.
URS
These lances make it possible to insantly switch among three different conditions, that is closed %u2013 straight jet %u2013 adjustable full cone spray.
The two larger size models can be supplied complete with an optional water curtain, to avoid the fire fighter beoing exposed to radiant heat from the open flame. |
|
Very light (270 g for a pair size 10) and comfortable, this flexible industrial glove is also machine washable. A GORE-TEX® membrane brings an ultimate barrier protection.
The ease of hand movement combined with a perfect fit ensures a high level of dexterity. As a result, time spent in hazardous area is reduced as the level of productivity and quality is increased.
|
|
| CAT PUMPS specializes in portable FOAM FIREFIGHTING SYSTEMS for fast knockdown of professional brush and grass wildfires. Our FOAM FIREFIGHTING SYSTEMS feature the twin foam professional gun delivering a precise metered foam and high pressure spray to quickly control fires. Ultra compact units from 4-18 HP are designed for easy mount onto ATV's, pickup trucks and utility vehicles. |
|
The self-checking RUBY PACKSCAN flame detectors are mainly designed for monitoring gas burners manufacturers.
They transmit a binary safety signal on the presence or absence of a flame.
The response time to a flame shutdown is less than 1 second, as per Standard EN298 relating to gas safety equipment.
The RUBY PACKSCAN detector uses a detection tube for ultraviolet wavelengths between 185 and 280nm.
An auto-checking mechanism for the tube covers the sight hole three times per second in order to ensure self checking operation.
A display enables visualisation of the configured parameters as well as the level of detection.
30 years in the field of flame detection gives the RUBY PACKSCAN the following advantages :
• an ‘all in one concept’ with an integrated professional amplifier in the professional scanner head for easy installation
• two microprocessors for increased safety and reliability
• Approved by APAVE meeting all safety criteria requirements.
• Detection level indicator to simplify commissioning
• Various standard confi guration methods by internal switches, by
remote and serial link to simplify configuration.
• DPDT output switch to indicate flame presence and proper detector operation. |
|
ANSUL® vehicle fire suppression systems were invented and introduced in the 1960's. Since then, as mobile equipment has grown in size and complexity, so have our system engineers and chemists jointly developed a new generation of fire detection and suppression products including Triple IR Detection, Twin-Agent Suppressing/Cooling Technology.
From small vehicles to large non-road equipment, you'll find ANSUL systems protecting professional excavators, haul trucks, loaders, drag lines, dozers, professional drills, scrapers, graders, compactors, slag pot carriers, underground mining equipment, forestry and agricultural vehicles. |
|
| ... products without technical information |
| |
|
|