- Robotics - Automation - Industrial IT >
- Automation >
- 4-20 mA converter
4-20 mA converters
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... input with/without compensation for cable resistance in two ranges -50 to 300°C and -50-100°C . • Output 0-10VDC/2-10VDC/0-20/4-20mA - selected via terminals. • Output ...
... input with/without compensation for cable resistance in two ranges -50 to 300°C and -50-100°C . • Output 0-10VDC/2-10VDC/0-20/4-20mA - selected via terminals. • Output ...
... PC. This device is based on a microprocessor with a 24-bit ∆∑ A/D converter, which guarantees high accuracy and excellent stability. Input: 0…2/5/10 V 0…5/20 mA, 4…20 ...
... also use this converter as a splitter into 2 analogue outputs. This device is based on a microprocessor with a 24-bit ∆∑ A/D converter, which guarantees high accuracy and excellent stability. ...
... backup battery (guarantees measurement in the absence of power) 4 GB data logger BIV self-checking function of the electrical characteristics of the sensor. Description The converter with display ...
... REPEATER POWER SUPPLY / ANALOG SIGNAL CONVERTER AND TRIP AMPLIFIERS DESCRIPTION The single channel Power Supply Repeater and Trip Amplifier D5254S provides a fully floating dc supply to energize conventional 2 wires ...
GM International srl
... resistance thermometer values into a standard 4-20mA current signal in all areas of the industry. Converter’s configuration can be easily set by the user as requested ...
31712-00 type are digital converters for a rod head using the 2-wire technique Input : PT 100 ohm or thermocouple J K T R S B or mv Output: 4/20 mA programmable for scale, ...
31713-00 type are 4/20 mA programmable converters using the two-wire technique with a local display assembled in an IP 65 epoxy painted aluminum case Input: thermocouple ...
The isolated frequency converter DAT 4540 is able to measure, up to 20 KHz, the frequency of TTL, Namur, NPN, PNP and Tachometer digital signals. In function of programming, the measured values are converted ...
DATEXEL SRL
... instrumentation. With DIL switches can be selected: Current output 0-20 mA or 4-20 mA; “Unipolar” voltage output 0-5V or 0-10V and “Bipolar” voltage ...
... designed to convert RTD100, thermocouples, potentiometer, mA, mV and other standardized current signals coming from the hazardous area to the safe area. Output: up to 2 4/20mA ...
... seals the unit to IP65 (NEMA 4X). Access to the terminals is via a pair of glands on the bottom of the enclosure.of glands on the bottom. Analogue Converter For Flow Meters: Features 0/4-20mA, ...
... mm by 50 mm Flash programmable T210 is an OEM board designed for integration in 4-20 mA instruments with a Modbus RTU output. It allows upgrade of 4-20mA ...
... ADC DAC module with 24-digit ADC converters is used for high-precision signals measurements in wide dynamic range. The signals to be measured are received from primary transducers – for instance, from sensors with 4-20 ...
... air consumption due to piezo electric microvalve Model - IPC Input signal - 4 ~ 20㎃ @ 24 VDC , 2-wire Output pressure - 0 - 1bar (0 - 15psi) 0.2 - 1bar (3 - 15psi) 0.4 - 2bar ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining