Lytron's ES Series aluminum oil coolers are engineered for high performance with poor heat transfer fluids such as oils and EGW. The extended surface flat tube design provides 2.5 times better performatnce than competitive units. The unique flat tube and header designs result in lower pressure drop so smaller, less expensive pumps can be used. Welded headers are pressure tested to 150 psi (10.3) bars and the fluxless, vacuum-brazed core provides strength and reliability. The Aluminum Oil Coolers are available with or without a fan plate, and with finish options of aluminum or black paint.
|
|
BWT platecooler series
Highly efficient heat transfer
Compact dimensions
Low water consumption
Highly turbulent flow
Very efficient oil / water cooler with small physical dimensions. Easy handling and installation. Due to highly turbulent flow very little tendency of fouling, almost maintenance free.
|
|
New LAC2 air/oil coolers with AC motor
Up to 20 % higher cooling capacity 160 Kw. The LAC2 cooler is suitable for installation in most applications and environments.
Economic and environmental benefits
- The hydraulic system’s and oil’s useful life is extended
- The hydraulic system’s availability increases, more operating time and fewer shutdowns
- Service and repair costs are reduced
- High efficiency level maintained in continuous operation.
|
|
|
New in the range of the exchangers air/oil LDC for capacities of cooling up to 130 kw with a delta of 40°C These heat exchangers OILTECH have electric motor with D.C. current LDC.
|
|
|
The coolers of technology air/oil for capacities of cooling up to 130 kw with a delta of 40°C These heat exchangers OILTECH lay out of electric motor AC current LAKE or engine with D.C. current LDC or hydraulic LHC.
|
|
QUESTION OF SIZE...
EXCHANGER OLAER LAKE 200
The largest exchanger produced in this range by Olaer.
Olaer, has just supplemented its range of exchangers air/oil with alternative course. The exchanger LAKE 200 makes it possible to reach capacities of cooling up to 300 kw with Delta T 40°C.
This exchanger is particularly adapted to the cooling of the hydraulic engines in heavy industry (building machineries of roads, mining, oil and gas, offshore oil rig...)
The LAKE is available with engine version 6 or 8 poles.
|
|
AIR-OIL HEAT EXCHANGERS WITH ALTERNATING CURRENT ELECTRIC FANS - SERIE AP:
Today the use of air in hydraulic equipment is more and more common.
The benefits are: No water supply required Totally independent of plummed systems Reduced running costs in comparison with the water-oil exchangers, even if initial investment is higher
Residual warm air can be used for heating
With air-oil heat exchangers the radiator unit is of aluminium for minimum conduction.
|
|
HA Serie:
Standard air-oil combined two-circuit heat exchangers used for cooling compressors from 7.5 to 160 kW. Radiator in aluminium alloy, vacuum braze welded, with high-efficiency turbulators on the air side. Power supply of fan only in AC, blowing ventilation.
|
|
Air/Oil standard heat exchangers
The range of air/oil heat exchangers has proved to be extremely reliable for a number of different hydraulic oil cooling requirements using the air generated by electric fans, hydraulic fans or, in the industrial sector, by single-phase and three-phase electric fans. The availability of models has now been further extended in order to satisfy all requirements.
|
|
Air-Oil heat exchangers have been designed to be used on the return line of the hydraulic systems.
The radiating mass is made of aluminium alloy, nominal pressure of 25bar and max Temperature 120C.
In addition to the standard SS and ST series, there are the SS2/ST2 double pass series for a higher heat exchange and SD/SDT series for higher flows (up to 320 L/min).
|
|
HY Serie:
Standard oil-air heat exchangers used for the cooling of industrial systems and mobile machines. Radiator in aluminium alloy, vacuum braze welded, with high-efficiency turbulators on the air side. Power supply voltages of fan AC, DC or with activation by means of hydraulic motor. Intake fan for better cleaning of the radiant package, anti-vibration supports always included.
|
|
AKG C and CP Coolers
Oil/compressed air combination coolers for screw compressors with up to 110 kW driving power. Proven AKG cooler models used worldwide. Trust the experience of AKG as the market leader for the cooling of compressors.
CP-Series... for high duty applications in medium and upper performance classes up to 110 kW
C-Series... for medium duty applications in lower performance classes up to 30 kW
|
|
ASA 0115 :
- Pression de service (statique): 26 bar
- Matière de l'élément refroidisseur: Aluminium
|
|
DIRECT CURRENT AIR-OIL HEAT EXCHANGERS:
This series of heat exchangers is particularly useful in cooling oleo-hydraulic plant on mobile machinery as it is fitted with direct current 12 or 24 V electric fans. The cooling element is in aluminium, a material of high thermal conductivity, which provides high thermal yield from relatively contained dimensions. The particular conformation of the radiant block is such that APL series heat exchangers are highly resistant to the stress produced by hammering which, however, at peak value, should not exceed the maximum dynamic pressure of 20 bar. The maximum permitted static pressure is 35 bar.
|
|
HM Serie:
Air-oil heat exchanger with tank and filter, used for the cooling of hydrostatic transmissions, especially on cement trucks and concrete machines. Power supply voltage of intake fan exclusively 24 V DC.
|
|
|
The heat exchangers PICKER are manufactured with following building materials, according to families of exchangers. This list is not exhaustive, to refer in the overall plans of the apparatuses to know the possible material combinations for a given family of exchangers. The choice of such or such material is mainly dictated by nature, the temperature and the conditions of circulation of the fluids in the exchangers.
|
|
|
Water-oil heat exchangers are shell and tube type. they permit to waste the heat in hydraulic plants. They can operate on exhaust line of the main hydraulic circuit, or on a separate circuit dedicated to cooling
|
|
WATER-OIL HEAT EXCHANGERS WITH TUBE BUNDLE
They consist of small diameter smooth tubes; this allows the best compromise between high thermic yield and low pressure loss. For a good exchanger practices some oil rates are indicated in the tables. Going down to the lowest rate of flow, indicated in the tables, the low oil speed causes a great loss in yield, whereas a rate of flow which is superior to the maximum indicated, causes great pressure loss and does not considerably increase the thermal yield. The yield diagrams indicate the heat quantity each exchanger can disperse according to the difference between oil and water mean temperatures. Such diagrams assume the exchangers to be working with the maximum oil rate indicated in the table. With the minimum rate, the yield decreases by about 10%. Required water volume is a follows:
85 l/h for each kW to disperse with water temperatures (20°C)
170 l/h for each kW to disperse with higher water temperatures
|
|
HW Serie:
Water-oil shell and tube heat exchangers, used for the cooling of industrial systems and in the marine sector. Fully extractable shell and tube for better maintenance of the heat exchanger. Aluminium body, designed to allow maintenance without the need to disassemble the heat exchanger. Cast iron heads in the industrial version, bronze in the marine version. Fluid circulation exclusively in countercurrent.
|
|
Basco Type OP Heat Exchangers
First introduced in 1962, the Basco OP design has proven to be the preferred TEMA Type AEW shell & tube heat exchanger in the market. The "OP", or "O-Ring Protected" design features removable tube bundle, nozzle location flexibility, and a unique threaded O-ring retainer that permits removal of the reversing bonnet without disturbing the piping or draining the shellside fluid. Removal of the channel cover permits full inspection and cleaning of the tube side.
|
|
cooling power:1-250KW
application:hydraulic and lubrication oil cooling system
working pressure:10-26Bar.
Dc or AC drive
|
|
| ... products without technical information |
| |
Custom-built heat exchanging solutions
AKG project manages and manufactures custom-built building machinery for a mul-titude of applications and operational conditions, from front-end loaders via hydraulic excavators to tunnel driving machines.
There are system solutions based on single coolers and cooler combinations, in compact constructions, powerful, in individual, application specific optimized designs.
Products
Water-coolers
Coolant-coolers
Charge air-coolers
Fuel-coolers
Hydraulic oil-coolers
Gearbox oil-coolers
Engine oil-coolers
Lubrication oil-coolers
Coolant media-coolers
|
|
Concrete mixers and moving machines use oil cooler
cooling power:6-12kw
oil volume flow:20-80L/m
12V or 24V DC
complete set with fan,shroud and guard.
oil sealing,filter and thermo switch enclosed.
|
|
|
|
|
|
The mixer/heat-exchanger CSE-XR was developed and patented by Fluitec AG. It is the most important invention in the static mixing technology of the last 20 years.
The CSE-XR is mainly used for temperature conditioning of highly viscous liquids at laminar flow. A strongly defined and well controlled homogeneity is guaranteed in any situation as well, as a very narrow residence time distribution. The reason for this excellent performance is its geometry, which is consequently based on the geometry of the most efficient static mixer type, the CES-X.
The very high radial mixing efficiency constantly ensures an intensive flow against the internal heat transferring tubes, thus allowing a
the compact design of this device.
Multitube heat exchangers are often not dedicated for scale-ups. Problems occur mainly in cooling processes at laminar flow conditions, when the product can "freeze" in particular tubes, due to its increased viscosity at lower temperatures. Uncontrolled residence time distribution and maldistribution are thereby leading to a bad process control.
Monotube heat exchangers (tubes with a double shell) can be built much smaller, if using static mixers. The mixing elements are improving the surface renewal rate significantly.
|
|
Heater applications
* Fuel oil
* Lube oil
* Fresh water
* Cargo
* Tank outflow
* Tank suction
The GEA Bloksma oil & water heater V-type is a compact heat exchanger for heating heavy fuel oil, lube oil, diesel oil or water by means of steam, thermal oil or hot water.
The thermal calculation is based on the latest heat-transfer technology. This ensures an optimal design of the heater.
|
|
Split solar water heaters HFT-300L HFT-200L
Working principle
This split solar water heating system has solar collectors on roof and water tanks inside the house, and transfers heat energy collected by the collectors into the tank by natural or forced circulation of the working fluid between collector and the tank.
Components:
The system comprises of solar collectors, a water tank, a heat exchanger, a controller and pumps.
|
|
| ... products without technical information |
| |
|
|
|
|
Instantaneous Water Heaters
The Armstrong packaged I.W.H. units are available in several ranges fulfilling a large variety of application demands. The I.W.H. is ideal for hotels, resorts, hospitals, rental apartment/condo buildings, commercial buildings, schools, institutional facilities (prisons), army barracks, sport arenas, nursing homes, shopping centers, and process applications. Whatever your application, Armstrong has the unit and the necessary expertise to address and satisfy your needs. Armstrong I.W.H packaged systems are designed to provide hot water instantaneously - from zero demand to maximum rated output - without the need for hot water storage tanks. The I.W.H. packaged system, an innovative approach to the supply of hot water, was exhaustively tested and proven. The unit comes completely assembled on a common base-plate. The heat exchanger is a plate type offering fast heat transfer and making it ideally suited for applications with rapidly changing demands. The I.W.H. comes equipped with a motorized 3-way control valve and PID (Proportional plus Integral plus Derivative) temperature controller.
Design Features
- Space is at a premium SMALL FOOTPRINT
- Night-time temperature set-back — ENERGY EFFICIENT
- Optional Double-Wall plates NO CROSS-CONTAMINATION
- Instantaneous supply NO SHORTAGE OF HOT WATER
- Reduced risk of Legionella disease NO STORAGE
- Ease of installation JUST PIPE-IN & WIRE
- Simplified maintenance BACK-FLUSH PERIODICALLY
- High temperature limit switch on all models
- Temperature control within ± 4°F (± 2.2°C)
- Control panel UL & CSA Approved
- Building Automation System compatible
- Single source of responsibility and support
|
|
|
|