- Electricity - Electronics >
- Electronic Component >
- Active electronic filter
Active electronic filters
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... of CISPR22 /EN 55022 Class B. EMC filter used with the MORNSUN AC/DC module, AC/DC module’s max. Input voltage must not more than EMC filter’s max. Voltage, AC/DC module’s max. Input current must less ...
MORNSUN Guangzhou Science & Technology Co.,Ltd.
... requirement of CISPR22 /EN 55022 Class B. EMC filter used with the MORNSUN DC/DC module, DC/DC module’s max. Input voltage must less than EMC filter’s max. Voltage, DC/DC module’s max. Input current ...
MORNSUN Guangzhou Science & Technology Co.,Ltd.
Frequency: 150 kHz - 30,000 kHz
Voltage: 14 V - 160 V
Primary current: 8.3 A
FEATURES - Ultra-Wide input voltage range: 14 -160VDC - High efficiency up to 98% - Operating ambient temperature range -40℃ to +105℃ - Meet IEC/EN61000-4 series standards and CISPR32/EN55032 - Meet railway industry EN50155 standards
MORNSUN Guangzhou Science & Technology Co.,Ltd.
Frequency: 10 Hz - 55 Hz
Voltage: 12 V - 30 V
Primary current: 4,000, 500 mA
S15F in-line filters are small, plug-in accessories designed to connect directly to a sensor, indicator, or other device. They fit seamlessly into your factory applications and begin operating immediately to suppress ...
Modular Jack Filters, 8-Pin Jack, 8 Loaded Positions, RJ45 Connector Input, PCB Mount Output, Filtered, None, None, Ethernet Magnetics • TE Internal Description: DISCR.ETH.MAG. 10/100 SINGLE SMT • Filter ...
TE CONNECTIVITY
Frequency: 60, 50 Hz
Voltage: 208 V - 480 V
Primary current: 20, 320, 40 A
... Hitachi Energy? • More than 20 years experience in active filtering solutions • Compliance to grid standards and norms • Integration of load balancing, power factor compensation and harmonics filtering ...
Frequency: 400 Hz
Voltage: 250 V
Primary current: 1 A - 20 A
Rated currents up to 20 A Excellent performance/size ratio Optional medical versions (B type) according to IEC/EN 60601-1 Snap-in versions (S and S1 type) Hot inlet versions (HI type) Optional overvoltage protection (Z type) Operating ...
Frequency: 400 Hz
Voltage: 250 V
Primary current: 1 A - 10 A
Rated currents up to 10 A Integrated dual fuse holder Optional reduced leakage current versions (A/B type) Complies with IEC/EN 60601-1 Snap-in versions (S type) High attenuation performance Voltage : ≤ 250 V Operating frequency ...
Frequency: 60 Hz
Voltage: 350 V
Primary current: 2, 5, 8 A
Voltage rating up to 350 VAC Current rating 2 A, 5 A and 8 A Offers attenuation fitting to lighting application Compact, space-saving design Cable outlets with enhanced length give freedom for flexible installation Operating frequency ...
Frequency: 60, 50 Hz
Voltage: 400, 690 V
Primary current: 30 A - 150 A
... SFR-APF series Active Harmonic Filter is a new type of power quality improvement products for the harmonic distortion in the circuit. With the advantage of the Fast Fourier Transform(FFT) and 3-Level ...
Frequency: 50, 60 Hz
Voltage: 400, 690 V
Primary current: 30 A - 150 A
... SFR-APF series Active Harmonic Filter is a new type of power quality improvement products for the harmonic distortion in the circuit. With the advantage of the Fast Fourier Transform(FFT) and 3-Level ...
Suppressor modules from Murrelektronik ensure machine availability. The benefits of suppressor technology are enormous and far outweigh the measures linked with its deployment. For a small price, you can prevent malfunctions or faults ...
MURRELEKTRONIK
Frequency: 60, 50 Hz
Voltage: 480, 400 V
Primary current: 30 A - 400 A
... filtered for maximum filter effectiveness Power factor correction both inductive and capacitive Phase current balancing, improvement of consumption in neutral (4W model) If higher filtering capabilities ...
CIRCUTOR
Frequency: 60, 50 Hz
Voltage: 480, 400 V
LCL filters have been specially designed to eliminate the harmonics from the current absorbed by 6-pulse power converters, such as frequency variators for motors, UPS, etc. These are essentially passive filters ...
CIRCUTOR
Frequency: 60, 50 Hz
Voltage: 480, 400 V
The LCL-TH filter is an LCL filter that is regulated through static switching operations (thyristors) and which has been specially designed to compensate harmonics in 6-pulse power converters that work ...
CIRCUTOR
Our common-mode filters, for example, are suitable for high-speed differential signal interfaces in IT and communications devices such as USB 3.0, DVI, HDMI, and Serial-ATA. The common-mode filters for ...
TDK Electronics Europe
... , lower energy loss and lower maintenance costs. Features & Benefits Delta's Active Power Filter APF2000 uses a current transformer to monitor load current and filter harmonics in ...
Frequency: 100 MHz - 3,000 MHz
... band pass filters and band reject filters (also referred to as band-stop filters or band-rejection filters) are bench top units designed for lab use where they are an ...
With the development of power electronic technology, the application of power electronic equipment, such as all kinds of rectifier, is widely used in industry, traffic and domestic appliance, and the ...
Frequency: 50, 60 Hz
Voltage: 400, 690 V
Primary current: 200 A
Active Power Filter (APF): Model Number: APF 3P3W 50A – 200A, APF 3P4W 50A – 200A Nominal Capacity: 50 A – 200A Nominal Voltage: 220VAC, 400VAC, 690VAC Nominal Frequency: 50HZ/60HZ Installation method: ...
Shenzhen Consnant Technology Co., Ltd.
Frequency: 50 Hz - 60 Hz
Voltage: 220 V - 690 V
Primary current: 100 A
Active Power Filter (APF) Model Number: APF 3P3W 50A – 200A, APF 3P4W 50A – 200A Nominal Capacity: 50 A – 200A Nominal Voltage: 220VAC, 400VAC, 690VAC Nominal Frequency: 50HZ/60HZ Installation method: ...
Shenzhen Consnant Technology Co., Ltd.
Frequency: 50, 60 Hz
Voltage: 400, 690 V
Primary current: 150 A
Active Power Filter (APF): Model Number: APF 3P3W 50A – 200A, APF 3P4W 50A – 200A Nominal Capacity: 50 A – 200A Nominal Voltage: 220VAC, 400VAC, 690VAC Nominal Frequency: 50HZ/60HZ Installation method: ...
Shenzhen Consnant Technology Co., Ltd.
... Guaranteed results Unlike other harmonic filter technologies, the performance of MTE Matrix Harmonic Filters is guaranteed! On AC variable frequency, variable torque drive applications (fans & pumps), ...
MTE
Frequency: 50 Hz - 60 Hz
Voltage: 400 V - 600 V
Matrix AP Harmonic Filters Product Overview The Matrix AP Harmonic Filter with MTEs innovative adaptive passive technology*, is the most advanced harmonic filter that provides improved ...
MTE
Matrix Filters® Product Overview MTE Matrix Filters solve the problem of harmonic distortion on virtually any two or six pulse rectifier. These power supplies are commonly found in electronic ...
MTE
Frequency: 60, 50 Hz
Voltage: 400 V
Primary current: 100 A - 10,000 A
Power Factor Correction The Aunilec APF not only compensate harmonic current but also the reactive power. It is able to correct for either a leading or lagging power factor. • Modular design, easy to extend • Up to 51st harmonic ...
Frequency: 50, 60 Hz
Voltage: 400 V
Primary current: 16 A - 66 A
LCL Filter for grid type converters and Four - quadrant inverter 90KW LCL filter is designed to solve Grid-Connection harmonic voltage problem, converting PWM voltage waveform to pure Sine Wave, lower ...
ACT Meters International Ltd provides a wide variety of alarm troubleshooting systems for intruder and fire alarms. The products address issues such as false alarms and system breakdowns resulting out of EMI, RFI and nearby lightning. ...
... Technologies FBAR (Film Bulk Acoustic Resonator) filters are a form of bulk acoustic wave (BAW) filter that have superior performance with steeper rejection curves compared to surface acoustic wave (SAW) ...
Frequency: 915 MHz
Voltage: 5 V
SAW Filter SAW Filter, usually called SAW, makes use of the piezoeletricity effect, to convert the input signal into mechanical energy with input and output transducer. After a procedure of processing, ...
The series of Harmonic filter reactors, which is manufactured by Entes, is device that is suitable for use in serial connection with capacitor banks in power factor correction components. By utilizing these kinds of reactors, ...
Frequency: 50, 60 Hz
Voltage: 120, 250 V
Primary current: 3, 6, 10 A
Features Single stage Chassis mounting High reliable High performance Fast on 6.3 x 0.8 mm terminals for input & output
Elcom
Frequency: 50, 60 Hz
Voltage: 250, 125 V
Primary current: 16 A - 32 A
... attenuation Unique Selling Proposition • First CEE power entry module with filter • Easy prewired solution • Universal flange for front or rear mounting • Optimal filter position direct on the power ...
EMI filters are low-pass, band-pass, or high-pass filters combined with ESD protection diodes. They also integrate pull-up and/or pull-down resistors, depending on the application. ST EMI filters ...
Frequency: 50 Hz - 60 Hz
Voltage: 250 V
Primary current: 1 A - 16 A
... temperature max. 45 °C Degree of protection IP 20 Advantages For general requirements Single‑stage filter concept Efficient filter effect against line‑bound interference emissions ...
Block Transformatoren-Elektronik
ON Semiconductor offers LC, RC, and common mode filters for a wide variety of audio and data interfaces.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining