The 100 to 200 CFM unit is our smallest conditioner and is conveniently designed to run on a 15 amp 115 volt power source. This unit does not require compressed air or ultra pure water (tap water is generally fine). The interior and exterior are constructed of corrosion-resistant stainless steel. Low watt density heaters also contribute to the unit's durability.
|
|
1 way cassette, designed for offices air treatment. 300 mm high, this unit can be settled into staff or modular false ceiling.
Coanda effect outlet slads.
2 sizes are available :
600 x 600 mm max. cooling power 3KW - heating 5 KW
600 x 1200 mm max. cooling power 6KW - heating 10 KW
Options : confort screen, 400 mm high casing, condensate pump
All regulations are available (incl. infra-red)
|
|
|
The Set Free FXN is a 3 pipe heat recovery VRF system operating on R410A this allows independent temperature control of up to 32 indoor units with simultaneous heating and cooling from one outdoor unit. Outdoor units range from 14-85 Kw cooling (nominal) and indoor units range from 2.2-14.1Kw cooling (nominal). Available in wall mounted, cassette, ducted, ceiling suspended and floor standing(cased or uncased) this is an extremely versatile range.
|
|
The High Ambient VRV®III air conditioning system represents
a ‘state of the art’ combination of cutting edge inverter
technology, ultra high efficiency and low running costs.
Unique within its field, it also possesses a number of
significant innovative features of benefit to specifiers, installers
and end users.
As a result of its 2 HP incrementally sized outdoor unit capacity
range, it can be applied successfully to both small and large
new buildings in addition to the many minor extensions and
total system upgrades inherent in refurbishment projects.
The VRV®III system provides a high indoor comfort for the users:
- The VRV®III heat recovery system has the ability to run no less than 64 indoor units for simultaneous heating and cooling operation, meaning every room can be conditioned as the occupant wishes.
- Continuous heating, results in a higher heating capacity, providing the highest comfort during winter time.
- Low operation sound level down to 25dB(A)
Also for installers the system has several advantages:
- Automatic refrigerant charging and testing and the Daikin “super wiring” system reduce the installation time dramatically.
- Thanks to modularity of the system, less refrigerant piping is needed (around 30% less installation costs).
Finally for designers the systems offers a wide range of advantages:
- The wide indoor unit range (75 variations), long piping lengths (up to 1,000 m), and various outdoor ranges offer the designer almost unlimited design possibilities.
For more information or other types VRV systems, please go to the link and you will be connected to the official Daikin site.
|
|
The compact, high efficiency, low noise and low vibration design if further enhanced with the on board Hitachi microcomputer, allowing extremely accurate set point control. As would be expected from one of the leading names in the industry, the Hitachi Samurai Range includes a multi-point fault and alarm system, through the 4, 7 segment LCD displays.
- R407c Refrigerant
- hitachi Screw Compressor
- Modulating Capacity Control 25-100%
- Plate Heat Exchanger
- Economiser Circuit
|
|
A hermetically closed cooling circuit with environment-friendly refrigerant provides for the temperature control of the medium flow. A circulating pump continuously delivers the cooled or heated medium to the inside devices. The built-in reservoir makes sure that the compressor does not start up every time the inside devices require cooling or heating output. In contrast with standard air-conditioning systems, it treats the compressor with care and increases the service life.
- High performance, cooling output between 5.8 and 140.2 kW
- Weather-resistant stainless steel housing
- Complete equipment, ready for installation with reservoir, expansion vessel, and circulating pump
- Chiller without hydronics part from RVS 5300 INOX for adaptation to plant requirements
- With winter regulation for operation from +45°C to -10°C in the standard design
- Compact design
- With protective grille in the standard design
- Low-noise device design with infinitely variable output adaptation of the fans
- Microprocessor-control regulator with display of actual operating values
- Automatic monitoring of the phase sequence
- High operating safety due to permanent monitoring of all relevant parameters
- Extensive accessories available
|
|
The Water Cooled Cooling Only Chillers RCUE WG2 are available in wide range from 40 to 240 Hp (134 to 696kW) each unit incorporates the latest developments in screw compressor technology. The compressor's continuous capacity control allows for a 15 to 20% energy saving over step control, this along with the unique electronic control system enables the chiller to precisely maintain a constant outlet temperature independent of cooling load. This benefits not only air conditioning but also industrial process use.
- Screw compressor highly reliable with very low noise and vibration
- Continuous capacity control allows for a 15 to 20% energy saving over step control
- Outlet water temperature controlled precisely independent of cooling load
- Plate type heat exchanger, increased efficiency but with less refrigerant
|
|