The gas heater KING is an independent appliance that
can be used as a great and convenient alternative to the
standard boiler house heating. With KING you have the
possibility to programme the temperature you want in
the room you need, with the possibility to programme
the temperature in every single room reaching therefore
and energy saving up to 30-40%. It is made up of an
elegant ivory varnished cover, a cast iron heat exchanger
(with control window for inspection pourposes) that
guarantee a very silent working, of a burner with safety
valve and wall flat fume/air kit that ensure a tight working
of the convectors with respect to the inner environment.
KING convectors can be used in houses, laboratories,
bars, shops, offices, and… wherever you want to
save energy! The working characteristics comply with
the standards UNI- CIG7129 for machines type C, gas
fired.
There is also the CLIMA-KING range with models from
7,2 to 13,3 kW which add to the heating function the airconditioning
function for summer time. |
|
Major 2
The Major 2 fan coil unit is designed to be mounted vertically on a wall or horizontally below ceilings to heat and cool homes, businesses and industrial and healthcare facilities. Not only does it combine the economic benefits of installing and operating a central boiler and chiller plant, it also allows individual temperature control in all rooms.
Available in six sizes and two models:
- CH: horizontal cased,
- CV: vertical cased.
Heating capacity: 2 to 20 kW
Cooling capacity: 0.6 to 8 kW
Air flow rates: 115 to 1300 m³/h
- Polymer casing with solid RAL 9010 finish,
- Two access doors lead to air bleed valve and control terminal,
- Water coil: two or four tubes or two tubes and electric heater,
- Condensate drain pan,
- Seven-speed motor (three factory-wired speeds) with balanced, double-inlet aluminium blower wheel,
- Mounting bracket frame,
- Regenerative polyester fibre filter. Efficiency class: G3 (EN 779),
- Fully enclosed electrical junction box,
- A wide selection of control options. |
|
Thalassa fan convector are reversible heating and air conditioning.
The offered range includes 4 models and 5 sizes, with powers from 5 kW cold production and 11 kW hot production.
Since there is poor residual pressure with this equipment (20 Pa), they are used preferably for direct blowing either hanging or wall mounted, with or without casing.
Easily integrated in any type of premises due to its discrete presentation and RAL 9010 epoxy painted frame.
Aircalo offers a wide scope of flow control customization. |
|
| ... products without technical information |
| |
The gas heater KING is an independent appliance that
can be used as a great and convenient alternative to the
standard boiler house heating. With KING you have the
possibility to programme the temperature you want in
the room you need, with the possibility to programme
the temperature in every single room reaching therefore
and energy saving up to 30-40%. It is made up of an
elegant ivory varnished cover, a cast iron heat exchanger
(with control window for inspection pourposes) that
guarantee a very silent working, of a burner with safety
valve and wall flat fume/air kit that ensure a tight working
of the convectors with respect to the inner environment.
KING convectors can be used in houses, laboratories,
bars, shops, offices, and… wherever you want to
save energy! The working characteristics comply with
the standards UNI- CIG7129 for machines type C, gas
fired.
There is also the CLIMA-KING range with models from
7,2 to 13,3 kW which add to the heating function the airconditioning
function for summer time. |
|
Major 2
The Major 2 fan coil unit is designed to be mounted vertically on a wall or horizontally below ceilings to heat and cool homes, businesses and industrial and healthcare facilities. Not only does it combine the economic benefits of installing and operating a central boiler and chiller plant, it also allows individual temperature control in all rooms.
Available in six sizes and two models:
- CH: horizontal cased,
- CV: vertical cased.
Heating capacity: 2 to 20 kW
Cooling capacity: 0.6 to 8 kW
Air flow rates: 115 to 1300 m³/h
- Polymer casing with solid RAL 9010 finish,
- Two access doors lead to air bleed valve and control terminal,
- Water coil: two or four tubes or two tubes and electric heater,
- Condensate drain pan,
- Seven-speed motor (three factory-wired speeds) with balanced, double-inlet aluminium blower wheel,
- Mounting bracket frame,
- Regenerative polyester fibre filter. Efficiency class: G3 (EN 779),
- Fully enclosed electrical junction box,
- A wide selection of control options. |
|
Thalassa fan convector are reversible heating and air conditioning.
The offered range includes 4 models and 5 sizes, with powers from 5 kW cold production and 11 kW hot production.
Since there is poor residual pressure with this equipment (20 Pa), they are used preferably for direct blowing either hanging or wall mounted, with or without casing.
Easily integrated in any type of premises due to its discrete presentation and RAL 9010 epoxy painted frame.
Aircalo offers a wide scope of flow control customization. |
|
| ... products without technical information |
| |
Magnetic flux control plays a key role in optimal coil design. We offer custom induction coil design to maximize production efficiencies to produce better parts for less cost.
As a starting point in assisting you in induction coil design, our engineering department makes a detailed analysis of the product heat treatment requirement and production environment (i.e.,workpiece material/geometry, heat treatment specification, production rate, sequence of operations, material handling equipment and available induction heating system parameters, etc.) and then considers other coil development stages including:
Heating style (limited control due to exisitng machines or bill of process)
Inductor design (coil style selection, copper cross-section, controller manufacturing & application, etc.)
Inductor engineering & fabrication
Inductor matching
Inductor set-up and tests
Final modification of inductor & process (if required) |
|
Guard-AC line/load reactors help keep your equipment running longer by absorbing many of the power line disturbances which otherwise damage or shut down your inverters, variable speed controllers, or other sensitive equipment. They are the modern technology solution to inverter and drive application problems. Guard-AC reactors are harmonic compensated and IGBT protected to assure optimum performance in the presence of harmonics. They are very effective at reducing harmonics produced by inverters and drives, and in most cases will help you to meet IEEE 519. Use our harmonic compensated reactors on either the input or output of an adjustable speed drive/inverter. There is no need to derate our "harmonic compensated" reactors for harmonics.
Protect Motors from Long Lead Effects
Reduce Output Voltage dv/dt
Virtually Eliminate Nuisance Tripping
Extend Semiconductor Life
Reduce Harmonic Distortion
Reduce Surge Currents
Reduce Motor Temperature
Reduce Motor Audible Noise
Improve True Power Factor
Helps Meet IEEE 519 or EN 61000-3-4
|
|
Magnetic flux control plays a key role in optimal coil design. We offer custom induction coil design to maximize production efficiencies to produce better parts for less cost.
As a starting point in assisting you in induction coil design, our engineering department makes a detailed analysis of the product heat treatment requirement and production environment (i.e.,workpiece material/geometry, heat treatment specification, production rate, sequence of operations, material handling equipment and available induction heating system parameters, etc.) and then considers other coil development stages including:
Heating style (limited control due to exisitng machines or bill of process)
Inductor design (coil style selection, copper cross-section, controller manufacturing & application, etc.)
Inductor engineering & fabrication
Inductor matching
Inductor set-up and tests
Final modification of inductor & process (if required) |
|
| Lepel Corporation offers custom coil design using the most advanced computer modeling programs available for complex requirements. Working from samples, drawings or electronic data, Lepel engineers enter specific process parameters, generate numerical and graphic plots predicting electromagnetic fields and engineer a coil of optimum size and shapwe for the specific application. Lepel's specialized design experience includes multiple coil configurations and coils that heat many locations simultaneously. |
|
Fluxtrol concentrator manufacturing and application technique plays a very important role in successful performance of induction coils. With respect to Fluxtrol concentrator application - magnetic, thermal and mechanical aspects must be considered. Additionally, the electrical strength of our concentrator must be considered or insulation provided.
This section is intended to provide methods for safety, handling and machining FLUXTROL® & FERROTRON® concentrator materials when applying the product to induction coils. |
|
| ... products without technical information |
| |
Advantages:
- Easy-fit basic frame
- Slim
- Easy connections
- Certain models may be delivered contained in a housing
- A wide range of options
Range :
- Several models and one range available on request
- Air flow rates: 500 to 80,000 m³/h
- BSH EC: Standardised coil in the SILENTHERME range, air flow rates: 1,000 to 10,000 m³/h
Use :
Circulates a fluid to warm or cool the air in commercial, industrial or healthcare facilities. May be ducted.
Description :
- Galvanised steel frame
- Various tube and fin types available
- Connections: tapped couplings with air bleed valves or smooth tubes
- A wide range of options
Features :
- Conception et dimensions et figées
- Nombreux modèles en stock
- Débit d'air de 200 à 80 000 m3/h
- Disposition verticale ou horizontale |
|
The unit involves an exchange between 2 fluids: a primary fluid in the tubes (water or gas) and a secondary fluid on the fins side (air or gas).
This exchanger offers many options in terms of materials and construction: dimensions, type and materials used in the tubes, fins, etc. |
|
|
|