Lagon range composed of 11 models, covering a flow scale from 1 000 to 72 000 m3/h.
- Various configuration available to meet air conditioning requirements.
- Different orientations for suction and blowing sides.
- Very wide scope of modular arrangement available.
New design to facilitate servicing and maintenance.
- Access to components through large hinged or sliding doors.
- Maintenance panels open by ¼ turn lochs.
- Filters to international sizes.
- Smooth internal sections to facilitate cleaning.
New design additional advantages.
- White RAL 9010 pre-lacquered sheet for external panel.
- Extruded aluminium structure with reinforced corners and integrated frame.
- External panels with a minimum visible screws.
Quality design.
- Double panels, 50 mm thickness.
- Insulation seals between 1st and 2nd wall.
- Compressed seal between panel and structure.
- Internal elements of recognised brand well to obtain a high quality product.
|
|
Climaciat Airtech
Air handling unit designed to meet the various mixing, filtration, heating, cooling, dehumidification, humidification, ventilation, recovery and sound attenuation needs in commercial, industrial and healthcare applications. Available as a horizontal unit for indoor installation or outdoor installation with canopy and protective accessories. Every model in the range may be ordered as single or dual path.
Available in 11 models with air flow rates of 1,000 to 66,000 m³/h
|
|
Types: The air treatment unit “STACE” is capable of covering a range of levels between 1.500 and 400.000 m3/h. We can also develop units with a higher capacity still with the same structure by the addition of local reinforcements
of larger dimension.
Geometry: The casing structure of the units is of the frame type on which insulated panels are fitted.
Version: The units are made in three versions:
A) A lighter version for capacities of up to 15.000 m3/h.
B) A medium version for capacities between 16.000 and 80.000 m3/h.
C) A heavy version for capacities between 80.000 and over 350.000 m3/h.
|
|
Air treatment unit double skin 25 mm. Mainly used for ceiling mounting with or without plate recuperator, this unit can be also settled externally on roof.
Air flow 500 à 6 000 m3/h
Cooling power 3.5 to 25 KW
Heating power 8 to 60 KW
Electrical heating power 6 to 32 KW
Pressure up to 500 Pa
Main applications : climatization, filtration, air introduction for extractor compensation, deshumidification.
|
|
Compensation air handling units are used for re-introduction of similar air volume to the volume extracted by various industrial process. Example : Painting plants, dust extractors, fume extractors ...
The inlet air volume is treated with filtration and/or gas heating. 2 types of heating :
- Direct burner in the air flowr (Efficiency 100%) - MAKE-UP
- Combustion chamber / exchanger burner - EOLIS
The regulation is on board and controls the extractors as well.
Air flow : 20 000 to 100 000 M3/H
Heating power : 300 to 1 500 KW
|
|
|
|
|
|
New space
Packaged, self-contained rooftop unit intended for air conditioning large surface areas. It is designed for outdoor rooftop installation on the premises requiring air conditioning.
Heating capacity between 20 and 286 kW
Cooling capacity between 19 and 277 kW
Air flow rate of between 4 000 and 46 000 m3/h
Available in 17 models and 2 versions:
- M0: Standard version - All-air return,
- MT: Version with a fixed fresh air inlet for the intake of a minimum amount of clean fresh air which can be manually adjusted using a damper,
- MS: Version with motorised damper at the air return and for the fresh air, thereby providing free-cooling operation when needed,
- ME: Version with motorised fresh air intake damper for the fresh air and at the air return + extraction propeller fan
- MK: Version with motorised fresh air intake damper for the fresh air and at the air return + automatic extraction damper which opens when there is a positive pressure in the room
- MA: Version with motorised intake damper at the air return and for the fresh air for free-cooling operation + an air return propeller fan with adaptable extraction damper depending on the positive pressure in the room,
- MC: Version with motorised intake damper at the air return, for the exhaust air and fresh air for free-cooling operation + an air return centrifugal fan to ensure the flow of exhaust air is equal to the fresh air intake flow.
- RPF: Cold only,
- IPF: Hot or cold reversible
|
|
Advanced air handling unit that creates precise micro-climates for sensitive pharmaceutical and medical device applications.
Temperatures from 15°C to 45°C and humidities from 30% to 98% relative humidity can be pre-set on the Micro-Environment Control System to provide consistent temperature and humidity controlled air for spot process applications.
Accuracy is within ±1%rh and ±0.1°C – a level which until now has been unachievable on a consistent basis. Air volumes are adjustable from 110 litres per second to 200 litres per second.
|
|
Air-handling unit (horizontal)
This system takes fresh air from outside and feeds the air into air-handling units on different floors of a building. First, ambient air taken from outside is filtrated through a filter, and pre-cooled or pre-heated with cool water or warm water from refrigerating machines and boilers. Then, the air is fed by fans throughout the building.
|
|
Air-handling unit for cleanrooms (industrial use)
With advances in technology, extremely clean air is increasingly required by hospitals and precision instrument plants. Kubota's air-handling units for cleanrooms meet such requirements by controlling dust in the air, temperature, humidity, and pressure within the required range.
|
|
Desiccant air-handling unit
This system has a high energy-saving efficiency, supporting regeneration temperatures of 50 to 150°C. Kubota's newly developed dehumidifying rotors using polymeric sorbent support the reuse of low-temperature exhaust heat of 50 to 80°C.
|
|
Supplied with high efficiency and reliable scroll compressors,
optimized heat exchangers and high-performing fans,
the rooftop UAT(Y)P series are designed to ensure a high
energy efficiency and reduced consumption.
The unit’s unique air conditioning ’plug and play’ concept and
single unit configuration allow hassle free installation
without the need for additional piping since both indoor
and outdoor sides are pre-connected.
Factory pre-charged refrigerant ensures clean and efficient operation.
For more information, please go to the link and you will be connected to the official Daikin site or take a look at the catalogue.
|
|
Renewal-responsive air-handling unit
Since this unit is designed to replace air conditioning systems in existing buildings, it can be assembled at the site of installation. The dimensions of the unit have been made as small as possible so it can be delivered through a narrow corridor in a building. Easy delivery and the smaller number of components necessary for assembly can solve many problems in replacing existing air-handling units for purposes of renewal.
|
|
These air Handling units are intended for use inside buildings, i.e. in plant rooms, basements, etc. The casings are made of sanwich panels filled witch rigid polyurethane foam or mineral wool between two sheets of metal. Panel thickness depends on the aplication and the water condotions. Sandwich panels give exellent thermal protection and meet rigorus acoustic requirements.
A wide performance scope ranging from 1 300 to 125 550 m³/h allows for using the Erato main units in large-volume buildings like:
- industrial halls
- super and hypermarkets
- warehouses
|
|
External main units are intended for use on the outside of buildings, e.g. on roofs.
Roof units are equipped with a little roof, air inlets and dischargers. The roof protects against precipitation and its profile prevents water accumulation and leaks. The design of the air inlet and air dischargers fitted with liquid traps and fine mesh preventing precipitation water and mechanical impurities from entering the inside of units. In order to ensure protection against weather conditions, all automatics components and movable elements (e.g. throttles) are located inside units. As an option, roof units are equipped with empty sections designed to accommodate control-pumping units.
A wide performance scope ranging from 1 300 to 125 550 m³/h allows for using the Erato main units in large-volume buildings like:
- industrial halls
- super and hypermarkets
- warehouses
|
|
|
The Deltafrimair® range has been designed principally to deal with the treatment of air to solve air-processing problems and to meet the high demands of industry. The standard range encompasses varying airflow’sfrom 1000m3/hr to more than 50,000m3/hr, and offers a multitude of possibilities concerning the mixing plenum, the filtration level, batterybank (heating and cooling exchanger), humidification systems, fan
|
|
|
ACUair® hygienic air-handling units incorporate state-of-the-art technology to provide refrigeration and meet filtration, pressurization, condensation control, and sanitization standards required by the food processing industry. Designed for rooftop installation, the units are custom engineered to produce the psychrometric conditions you specify. ACUair® products are the answer when clean conditioned air is needed for today`s hygienic food processing requirements. We offer a wide range of air distribution accessories including supply air diffusers, return air boxes or grills, and exhaust fans.
|
|
Features
39HH units use an ingenious system of profiles and panels to ensure long term resistance, rigidity and stability.
Assured water and air tight construction.
Ease of maintainence via demountable panels.
Smooth finish Double skinned panels
High Quality galvanised steel panels ensure high level of corrosion resistance.
Benefits include:
* elimination of condensation
* no corrosion
* Water tight and hygenic
* Special protection available against corrosion by cataphoric treatment.
|
|
Centrale d'air double flux Plug & Play permettant le renouvellement d'air hygiénique tout en économisant en moyenne 80% de la puissance nécessaire au conditionnement d'air.
Débit d’air : 300 à 2300 m3/h
Modèles : « Classic », « Vertical », « Plafonnier »
|
|