Primary current: 4,000 A - 63,000 A
VAC: 72.5 kV - 550 kV
The SDF disconnectors are available up to 550 kV, 4000 A and 63 kA. These type of disconnectors have a low friction design and offer minimized contact resistance. They are equipped with dead center interlocking ...
ABB AG
Primary current: 32 A - 1,600 A
... ELCB is not chosen to use in a special characteristic of the load, the special breaker is needed. On creating an isolation switch (DSN) by omitting the overcurrent tripping device of a MCCB, it can be used as a switching ...
Primary current: 40 A - 2,000 A
VAC: 690 V
Switch-Disconnectors Dumeco DMV Type DMV, 160 - 2000 A, 690 V AC, switch-disconnectors have excellent short-circuit making capacities, due to its parallel knife contacts with double break per phase. High ...
Eaton
Primary current: 100, 200, 30, 400, 60 A
VAC: 208, 240, 480 V
The Littelfuse® LPS Series provides a simple and economical solution for applications that require selective coordination and shunt trip capabilities. Utilizes Class J time-delay fuses that are easily coordinated with other system overcurrent ...
Primary current: 250, 400 A
VDC: 500 V
When trying to isolate circuits or repair systems, the LS60250 dc disconnect switch quickly breaks or resumes the flow of current safely to prevent shock hazards. It has a total voltage rating of 500 ...
Everything you need to make your application more efficient than ever: Commute easily power sources thanks to a changeover mechanism. Provide a real flexibility to fit with all type of installations thanks to a large choice of Pole units, ...
Primary current: 32 A - 1,250 A
FuPact GS : Switch-disconnector fuses, FuPact ISFT : horizontal fuse switch-disconnectors, FuPact ISFL : vertical fuse switch-disconnectors, FuPact range includes electronic monitoring ...
Primary current: 2,000 A
VAC: 126, 145 kV
Center break disconnector with smaller footprint and high reliability Hitachi Energy’s DDHV – ‘V’ type center break disconnector is a compact, reliable and easy-to operate substation equipment. Suitable ...
Hitachi Energy
Primary current: 3,150 A
VAC: 420, 72.5, 145, 245 kV
Maximum reliability and minimal maintenance The eDB disconnectors are available up to 420 kV, 3150 A and 50 kA. These disconnectors have a low friction design and offer minimized contact resistance. ...
Hitachi Energy
Primary current: 3,150 A
VAC: 800 kV
... and minimal maintenance The horizontal knee disconnector requires the smallest spaces in both horizontal and vertical directions, suitable for substation with small installation area. The DDK800 disconnector ...
Hitachi Energy
Primary current: 4,000 A
VAC: 72.5 kV - 550 kV
The center break is the most frequently used disconnector type worldwide. Its design is characterized by two rotating insulators that open and close the contacts in a sideways motion. Most important features and advantages: •Design ...
Siemens High-voltage – Power transmission
Primary current: 630 A
VAC: 690 V
MULTIVERT® NH 4P is the first vertical 4-pole switchable (3P + N) in-line fuse switch disconnector for busbar systems 185mm with an overall width of 100mm. It is the most inovative and cost-efficient ...
Mersen - Electrical Power
Primary current: 160 A
VAC: 690 V
... screw, clamp strap, Al-Cu clamp, extendable for V-terminal - optional • Padlocking and sealing of switch door cover - optional • Indicating switch for switch door position - optional • ...
Mersen - Electrical Power
Primary current: 250 A
VAC: 800 V
... termination: screw, bolt, clamp strap, extendable for V-terminal - optional • Padlocking and sealing of switch door cover - optional • Indicating switch for switch door position - optional • ...
Mersen - Electrical Power
VAC: 72,500 V - 550,000 V
The center break grid disconnector known as the Alstrom Grid S2DA, is one of the most commonly used in the world due to its easy, yet effective design in which both insulators open and close the switch. ...
Alstom Grid
Primary current: 32 A - 50 A
VDC: 1,000 V
The RM PV range of fuse disconnect switches is designed for use with gPV fuses that are cylinder-shaped. The switches are modular in nature. They are perfectly suitable in low DC voltage operations that ...
SOCOMEC
Primary current: 800 A
VDC: 750 V
The battery switch is used to connect and disconnect the DC power from the battery during maintenance of the battery box with a high level of safety. The TCMB line covers a current range up to 800A ...
Schaltbau GmbH
Primary current: 800 A
VDC: 750 V
The motorised battery switch is used to connect and disconnect the DC power from the battery during maintenance of the battery box with a high level of safety. The TCMO line covers a current range ...
Schaltbau GmbH
Primary current: 120 A
VDC: 5 kV
... for mounting in switchgear cabinets. With the proven C195 Series contactor mounted on top of the device it is possible to disconnect, with electric arc control, all permissible loads in passenger coaches (UIC 550) from ...
Schaltbau GmbH
II 2D Ex tb IIIC T85°C Db / Zone 21-22 (Dust) / Tamb = -20°C/+55°C / IP65 New switch disconnectors Regolus Ex for command and emergency in aluminum box painted in Grey and Yellow, suitable for use in ZONE 21 and 22 ...
Giovenzana International B.V.
REGOLUS SWITCH DISCONNECTORS provide the means to safely disconnect an item of electrical equipment from the supply. The Series are composed by a wide range of bodies, actuators and complementary accessories. ...
Giovenzana International B.V.
SE Series: Modular from 2 to 4 poles, from 32A to 100A has the possibility to install IP20 terminal protections and auxiliary contacts (SE16 – SE32 only). Available versions: Panel mounting Screw Fixing Panel mounting Ø22,5mm Central ...
Giovenzana International B.V.
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - ...
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - ...
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - ...
Primary current: 40 A - 1,600 A
VAC: 500, 1,000, 690 V
... the current situation of the switch. And finally they can also check the engine whether the contact blades are noticeable if so, it means that the switch is at 0 point. And if the blades are not noticeable ...
Cefem Group
Primary current: 40 A - 800 A
VAC: 1,000 V
VDC: 1,000 V
... operate the switch. If the contact (blades) are visible then the engine is switched OFF and is in 0 position as seen on the switch. On the contrary if the contacts (blades) are not seen then the switch ...
Cefem Group
Primary current: 630 A - 2,200 A
VDC: 750 V - 1,500 V
... switches are mostly used in the main switch, in the CC 750-V and 1,500-V switch-disconnector, and in safety switch for motors.
Cefem Group
Primary current: 400, 630 A
VAC: 12, 24, 36 kV
The Pomanique’s single break, insulator operated disconnector has been designed for both rural distribution and substation type disconnector applications and complying with IEC 60129. Rated voltage from ...
zhejiang Pomanique Electric Co.,Ltd
Primary current: 400, 630 A
VAC: 12, 24, 36 kV
The Pomanique’s single break, insulator operated disconnector has been designed for both rural distribution and substation type disconnector applications and complying with IEC 60129. Rated voltage from ...
zhejiang Pomanique Electric Co.,Ltd
Primary current: 400, 900, 630 A
VAC: 24, 15, 36 kV
... Reclosing Protection Frequency Protection Line Voltage Protection Inrush current Restraint Negative Sequence Protection Switch Operation Protection
zhejiang Pomanique Electric Co.,Ltd
Primary current: 32, 63, 100, 125 A
VAC: 230, 400 V
As the main switch in the combination of electrical terminal apparatus, GYH8 isolator is suitable for circuit of AC 50/60Hz, rated voltage 230V/400V, rated current up to 125A for isolating, it also can be used for infrequent ...
Primary current: 20,000, 31,500 A
VAC: 12 kV
... 62271-102. The switches can be used for a rated voltage range of Ur 12 kV up to 38.5 kV depending on the design and for a rated current of Ir 400 A, 630 A and 1600 A. Switch design: For the vertical assembly ...
Fritz Driescher & Söhne GmbH
Primary current: 1,250, 2,000 A
VDC: 2 kV
... possible to equip the disconnectors with position switches for the indication of the switch position (… IS or …TS). The disconnectors 2000 A can be delivered in the following ...
Fritz Driescher & Söhne GmbH
Primary current: 630, 1,250 A
VAC: 36, 38.5, 12, 24 kV
The Driescher's H22 is an indoor medium-voltage fused switch disconnector that is constructed with a three-pole feature. It is equipped with a rated current amounting from 630 A up to 1250 A. The rated ...
Fritz Driescher & Söhne GmbH
Primary current: 40, 25, 63 A
VDC: 600, 200, 1,000 V
Primary current: 20 A - 125 A
VAC: 400, 230 V
Primary current: 160 A
VAC: 1,500 V
New high-performance switch-disconnector capable of reaching 500 A – 1500 Vdc (750 Vdc per pole) Based on the innovative Magic patented technology, S7 is the result of years of research of our R&D team and the expertise ...
Telergon
Primary current: 20 A
VAC: 690 V
Panel mounting modular switch – disconnectors, are available from 20A to 125A in 3P – 3P+N. They are designed according to IEC/EN 60947-3 standard for use in civil and low voltage industrial installations, ...
Telergon
Primary current: 25 A
VAC: 690 V
Panel mounting modular switch – disconnectors, are available from 20A to 125A in 3P – 3P+N. They are designed according to IEC/EN 60947-3 standard for use in civil and low voltage industrial installations, ...
Telergon
JHAS69 isolation switch is widely used in industrial control 02 machinery and various electrical appliances, and can effectively solve the problems of emergency disconnection, safety disconnection, machine ...
Wenzhou Jinhong Electrical Appliance
Primary current: 2 A - 63 A
VAC: 400 V
... devices without active electronic components. They are able to switch on, direct and switch off currents under operation-relevant conditions. Fuse switch-disconnector switches ...
Doepke Schaltgeräte GmbH
Primary current: 16 A - 1,600 A
VAC: 400 V - 690 V
-IP 65 -Good corrosion resistance -Wide operating temperature range -Padlockable -Door interlock with defeat mechanism -Excellent Insulating properties -Good UV resistance -Good resistance against many chemi
Primary current: 16 A - 160 A
VAC: 400, 500, 690 V
•Three-pole switch disconnector, direct operating version, 25A •Type of product: Switch disconnectors •Number of poles: 3 •Type of operating voltage: AC •IEC Conventional free air thermal current ...
LOVATO ELECTRIC
Primary current: 250, 100, 200 A
VDC: 24 V
Carling Technologies IP67 sealed BD-Series battery disconnect switch is designed to minimize battery drain, ensure maintenance personnel safety, and when used in conjunction with a padlock, provides ...
Carling Technologies
Your suggestions for improvement:
Disconnect switches are used as a safety feature in the control of electrical circuits. They provide protection against electrical accidents during servicing or inspection.
ApplicationsDisconnect switches are commonly used in low-voltage switchgear, for starting and stopping motors and for isolating loads during maintenance. They also are found in motor control centers, on switchboards and as on/off switches for industrial equipment and machinery.
TechnologiesDisconnect switches use different insulating technologies depending on their voltage rating. Disconnect switches can also be fused in order to provide proper protection. There are also single-pole and multi-pole disconnect switches depending on the complexity of the circuit.
How to chooseWhen selecting among disconnect switches, be sure to determine your system's insulation voltage, operating voltage and current. An inappropriate choice could cause the switch to malfunction and possibly harm personnel or equipment.
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining