JUMO dTRANS T02 Ex Programmable 4-wire transmitter (70.7025/95.6525)
The JUMO dTRANS T02 Ex transmitter incorporate a microprocessor for digital signal processing.
Input and output are electrically isolated. It can be mounted on a DIN rail, the electrical connection is by screw terminals for stranded or solid wire up to 2.5mm² conductor cross-section.
The 0/4 - 20mA or 0/2 - 10V output signal is available either linearized (linear with temperature) or inverted (option). The transmitter can be programmed via the PC setup program, which is supplied as an accessory.
Current and voltage outputs are available directly on terminals. No hardware alterations are required.
|
|
eNod 3 : Digital measurement power 3 !
· 24 bits conversion, up to 1 600 meas./s.
· Digital filters
· RS485/232 and CANBus outputs, MODBus-RTU and CANOpen
ENod3 offers a low-cost and powerful solution to convert any strain-gauge sensor into an intelligent digital system:
- Digital high speed transmitter
- Dynamic weighing controller (Checkweigher)
- Peak value detection
Control the power of numerical filtering with eNodView freeware:
· Complete eNod setting up
· Measurement acquisition and displaying
· Signal analysis
· Digital filters simulation
|
|
The iT Transmitter is a signal conditioning module that interfaces with a traditional IEPE accelerometer to provide a 4-20 mA output signal and a buffered dynamic signal. This allows the user to interface an accelerometer with a PLC/DCS system for condition trending, while still providing a dynamic output for more extensive vibration analysis through the BNC connector on the front of the module. The iT Transmitter is ordered with custom settings to meet user-specific requirements.
With unique high- and low-pass filters - and a host of options for customizing the transmitter to your specific needs. By utilizing your existing sensor infrastructure, Wilcoxon's Total Lower Cost (TLC) Approach reduces the expense of online monitoring.
|
|
|
|
|
|
● ExMGZ 100/200.ATEX
ExMGZ 100 / 200.ATEX Intrinsically Safe Barrier The ExMGZ 100/200.ATEX intrinsically safe barrier is used for applications in intrinsically safe or explosion proof environments classified as II(2)GD [EEx ib] IIB / IIC. It is designed for single or double channel tension measurement and can be used with any FMS amplifier, controller, and force sensor. The ExMGZ 100 / 200.ATEX units
are DIN rail mountable, utilize screw terminal connections and are easy to install between the electronic unit in an unprotected area and a force sensor in a protected area.
● Functional description
The ExMGZ 100/200.ATEX intrinsically safe barrier utilizes a zener limiter on the force sensor side. It controls the voltage to the force sensor while preventing over voltage. A zener barrier is provided for each channel on the intrinsically safe side. Therefore the explosion proof area remains safe from hazardous voltage levels while still allowing the tension measurement or control to perform in the process. A control circuit ensures that the voltage drop of the zener barrier is compensated and it is guaranteed that the full excitation voltage is provided to the force sensors.
|
|
- Compact housing design
- Display and operating keys
- Communication capabilities
- Universal input for TC, RTD, R, I, U / 2nd universal input optionally
- Frequency / counter input
- Universal output
- 2 relays
- Galvanic isolation
Applications
Measuring, scaling as also isolation of electrical signals e.g. for
Heat treatment, drying equipment
Furnace manufacturing, metallurgical equipment, kilns
General machine building
Science and development
etc. ...
Main attributes
Interference free operation
High signal resolution
Sensor correction
Customized linearization
Slave pointer
Comfortable 3 key operation, dual line LC display
Communication interfaces
2 relay outputs
3 limits
|
|
- Transfer Data with accuracy, reliability and simplicity using our new uDockTM Model U2CI through the instrument's IR port
- Easy to install software from CD or www.myronl.com
- The uDock application will operate on Windows XP and Vista*; and Macintosh OS9.2 and OSX**
- Automatic organization of data (record number, type of measurement, value and unit measurement, solution, temperature, date stamp, and time).
- Exports to Office software (Word*, Excel*, Works*...etc) using universal formatting (.CSV) files
- Control your Ultrameter IITM and PoolProTM time and date setting though our uDock software.
- Clear instrument memory through our uDock software
- Self powered by USB portor eve
|
|
| ... products without technical information |
| |
|
|
|
|
AIR VELOCITY TRANSDUCERS 8465
The Model 8465 Air Velocity Transducer (Windowless) is ideal for both temporary and permanent installations for air velocity measurements in research and development labs, manufacturing processes, and other applications. Model contains on-board electronics and calibration curves that provide a linear signal output. This linear signal is sent out as either a current (mA) or a voltage (V) signal, allowing output to a variety of data loggers or data acquisition systems. Best of all, the current and voltage output ranges are easily changed by the user in under five minutes.
Ideal applications include comfort and draft studies, critical environment installations (e.g., clean rooms and hospitals), diffuser design analysis, monitoring drying processes, monitoring air flows in tunnels and subways, used as a standard in wind tunnels and calibration facilities, environmental monitoring in greenhouses and IAQ applications as well as general engineering applications.
Features and Benefits:
- Less flow blockage
- Available with choice of 3, 6, 9 or 12 inch probes
- Ideal for measuring in confined spaces
- Fast response time
- Range: 25–10,000 ft/min (0.125–50 m/s)
|
|
|
|
|
|
Measuring range : from 0/+10 Pa to -10 000/+10 000 Pa
Configurable intermediary and central zero ranges
Air velocity and airflow functions
Interchangeable measuring sensor (SPI technology)
Simultaneous display of 1 to 4 parameters
External transmitter unputs (KIMO class 200 and 300) and thermocouple K
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software, keypad or remote control configuration
MODBUS network RS 485 system (optional)
ABS or ALU IP 65 housing, with or without backlit gaphic display
Mounting with the 1/4 turn system with wall-mount plate
CP301 : -100/+100 Pa (resolution : 0.1 Pa)
CP302 : -500/+500 Pa
CP303 : -1000/+1000 mbar
CP304 : -10 000/+10 000 mbar
• Barbed fittings Ø 5,2 mm
• Unit of measurement : Pa, mmH2O, mbar, inWG, mmHG
• Power supply : 24 Vac /Vdc, 115 Vac or 230 Vac
• Outputs : 2 x 4-20 mA or 2 x 0-10 V
• Functions : pressure, air velocity, airflow with Pitot tubes, Debimo and other coefficients, integration of measure, self-calibration, measuring correction factor, temperature compensation : manual or automatic (thermocouple K input).
Join our distribution network all over the word....Contact us !
|
|
|
|
|
|
EE65 Series
Air Velocity Transmitter for HVAC Applications
EE65 air velocity transmitters are ideal for accurate ventilation control applications. They are operating on an innovative hot film anemometer principle.
The E E thin film sensor guarantees very good accuracy at low air velocity, which is not possible for conventional anemometers with commercial temperature sensors or NTC bead thermistors.
EE65 series are available with current or voltage output, the measuring range and the response time can be selected with jumpers by the user.
Low angular dependence enables easy, cost- effective installation
EE75 Series
High-Precision Air / Gas Velocity Transmitter for Industrial Applications
The EE75 series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities and temperatures.
A high-quality hot film sensor element based on cutting- edge thin film technology ensures maximum sensitivity, even at lowest mass flows.
At the same time, the innovative probe design produces reliable measuring results at high flow velocities of up to 40m/s (8000ft/min). The integrated temperature compen- sation minimises the temperature cross-sensitivity of the EE75 series which, combined with the robust mechanical design, allows it to be used at process temperatures between -40 to 120°C (-40 to 248°F).
|
|
|
|
|
|
ComfortSense
Thermal comfort measurement according to EN 13182, ISO 7736 and ASHRAE standard 113
Dantec Dynamics’ ComfortSense system is designed for research and development of heating and air conditioning systems requiring multi-point measurements of air velocity and temperature. Draught measurements require omnidirectional sensors with a frequency response of at least 2 Hz, which is fulfilled by the present system.
ComfortSense elements
The ComfortSense system consists of a main frame with anemometer circuits for up to 16 probes. The omnidirectional probes measure both air velocity and temperature. Six frames can be connected so that up to 96 probes can be monitored simultaneously. The ComfortSense main frame has a built-in A/D converter with USB 2.0 interface.
Easy-to-use
It is easy for the user to setup a measurement sequence and make a measurement grid with selection of probes from a user library. The software delivers statistical results based on user-defined measurement cycles. The ruggedly designed probes and cables are perfectly suited for large test rooms.
|
|
The Activa Sensor Array provides fl ow,
temperature and pressure signals in a compact
unit that requires only one hydraulic line break.
Each sensor transmits an output signal that is
easily integrated with PCs, PLCs, recorders or
panel displays. Signals can also be transmitted to
Flo-tech’s F6700/F6750 Series digital displays.
|
|
This range of small probes with 3 mini-sensors measure pH, ORP, conductivity, temperature DO and level in wastewater, natural water and underground water. These SDI-12 ultra low comsuption probes can be connected to all SDI-12 systems
Using AQUA, AQUA 10 or AQUA 50 probes allows you to measure up to 6 parameters simultaneously: Temperature, Conductivity, pH, ORP, Dissolved Oxygen and Depth.
- Fast connection to ISCO devices, ADCON remote systems or any other instruments using the SDI12 protocol
- Ultra low consumption (40 µA)
- Connection of the sensors by simple "clip"
- Pocket size for maximum user convenience (length = 420 mm, diameter = 40 mm)
- Flexibility in use : its independent connection cable length allows adjusting cable length according to your needs
3 probes are available :
- AQUA : Wastewater
- AQUA 10 : Surface water (0-10 m),
- AQUA 50 : Underground water (0-50 m).
|
|
Conductivity
Honeywell conductivity technology helps measure, analyze and transmit valuable conductivity, resistivity and concentration information in simple and complex industrial processes with a complete line of analyzers, transmitters and conductivity cells.
Dissolved Oxygen
A complete line of analyzers, transmitters and dissolved oxygen probes ensures highly accurate, stable and trouble-free measurement in all types of applications.
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
|
|
|
Transmitters are an integral part of on-line measurement systems used to monitor and control industrial processes. METTLER TOLEDO offers a comprehensive range of transmitters for pH, DO, conductivity, resistivity, TOC, dissolved ozone, turbidity,
|
|
|
|
|
|
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
|
|
|
|
Measuring range : from 0/+10 Pa to -10 000/+10 000 Pa
Configurable intermediary and central zero ranges
Air velocity and airflow functions
Interchangeable measuring sensor (SPI technology)
Simultaneous display of 1 to 4 parameters
External transmitter unputs (KIMO class 200 and 300) and thermocouple K
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software, keypad or remote control configuration
MODBUS network RS 485 system (optional)
ABS or ALU IP 65 housing, with or without backlit gaphic display
Mounting with the 1/4 turn system with wall-mount plate
CP301 : -100/+100 Pa (resolution : 0.1 Pa)
CP302 : -500/+500 Pa
CP303 : -1000/+1000 mbar
CP304 : -10 000/+10 000 mbar
• Barbed fittings Ø 5,2 mm
• Unit of measurement : Pa, mmH2O, mbar, inWG, mmHG
• Power supply : 24 Vac /Vdc, 115 Vac or 230 Vac
• Outputs : 2 x 4-20 mA or 2 x 0-10 V
• Functions : pressure, air velocity, airflow with Pitot tubes, Debimo and other coefficients, integration of measure, self-calibration, measuring correction factor, temperature compensation : manual or automatic (thermocouple K input).
Join our distribution network all over the word....Contact us !
|
|
|
|
|
|
ComfortSense
Thermal comfort measurement according to EN 13182, ISO 7736 and ASHRAE standard 113
Dantec Dynamics’ ComfortSense system is designed for research and development of heating and air conditioning systems requiring multi-point measurements of air velocity and temperature. Draught measurements require omnidirectional sensors with a frequency response of at least 2 Hz, which is fulfilled by the present system.
ComfortSense elements
The ComfortSense system consists of a main frame with anemometer circuits for up to 16 probes. The omnidirectional probes measure both air velocity and temperature. Six frames can be connected so that up to 96 probes can be monitored simultaneously. The ComfortSense main frame has a built-in A/D converter with USB 2.0 interface.
Easy-to-use
It is easy for the user to setup a measurement sequence and make a measurement grid with selection of probes from a user library. The software delivers statistical results based on user-defined measurement cycles. The ruggedly designed probes and cables are perfectly suited for large test rooms.
|
|
The Activa Sensor Array provides fl ow,
temperature and pressure signals in a compact
unit that requires only one hydraulic line break.
Each sensor transmits an output signal that is
easily integrated with PCs, PLCs, recorders or
panel displays. Signals can also be transmitted to
Flo-tech’s F6700/F6750 Series digital displays.
|
|
MODBUS AND 4-20 mA TRANSMITTERS FOR SPED AND FLOW IN GAS OR LIQUIDS DMM-4000/..
The DMM-4000/.. Series are two loops configurable field transmitters for specific variables with inputs adapted to each variable (DMM-4000/... where the suffix shows the version), e.g. Chemical (pH, Conductivity, etc.), Electric (V, A, RMS, etc.), Humidity (HR, HA, Enthalpy, Dew point), Pressure, Level, Flow, Pulse Counter, Vibration, Weight, etc.
Allows with low cost to take signals placed on field and to transmit them toward control systems as PC or PLC in mA and Modbus saving A/D and D/A conversion tasks. In option, they can be to communicate by Radio 868 MHz (915 MHz in USA) or by Ethernet, cable or WiFi, by means adapter modules RMT, EMT or WMT-1000 Series.
|
|
¨ DC or AC powered.
¨ Pulse and analog output scaled per unit of measure.
¨ Optional Hi and Lo alarms.
¨ Flowmeter Linearization.
¨ Factory configured when purchased with a Hoffer
flowmeter.
¨ Several Enclosure options.
¨ CE Compliant.
¨ Windows® Configuration Software
|
|
| ... products without technical information |
| |
|
|
|
|
Measuring range : from 0/+10 Pa to -10 000/+10 000 Pa
Configurable intermediary and central zero ranges
Air velocity and airflow functions
Interchangeable measuring sensor (SPI technology)
Simultaneous display of 1 to 4 parameters
External transmitter unputs (KIMO class 200 and 300) and thermocouple K
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software, keypad or remote control configuration
MODBUS network RS 485 system (optional)
ABS or ALU IP 65 housing, with or without backlit gaphic display
Mounting with the 1/4 turn system with wall-mount plate
CP301 : -100/+100 Pa (resolution : 0.1 Pa)
CP302 : -500/+500 Pa
CP303 : -1000/+1000 mbar
CP304 : -10 000/+10 000 mbar
• Barbed fittings Ø 5,2 mm
• Unit of measurement : Pa, mmH2O, mbar, inWG, mmHG
• Power supply : 24 Vac /Vdc, 115 Vac or 230 Vac
• Outputs : 2 x 4-20 mA or 2 x 0-10 V
• Functions : pressure, air velocity, airflow with Pitot tubes, Debimo and other coefficients, integration of measure, self-calibration, measuring correction factor, temperature compensation : manual or automatic (thermocouple K input).
Join our distribution network all over the word....Contact us !
|
|
|
|
|
|
ComfortSense
Thermal comfort measurement according to EN 13182, ISO 7736 and ASHRAE standard 113
Dantec Dynamics’ ComfortSense system is designed for research and development of heating and air conditioning systems requiring multi-point measurements of air velocity and temperature. Draught measurements require omnidirectional sensors with a frequency response of at least 2 Hz, which is fulfilled by the present system.
ComfortSense elements
The ComfortSense system consists of a main frame with anemometer circuits for up to 16 probes. The omnidirectional probes measure both air velocity and temperature. Six frames can be connected so that up to 96 probes can be monitored simultaneously. The ComfortSense main frame has a built-in A/D converter with USB 2.0 interface.
Easy-to-use
It is easy for the user to setup a measurement sequence and make a measurement grid with selection of probes from a user library. The software delivers statistical results based on user-defined measurement cycles. The ruggedly designed probes and cables are perfectly suited for large test rooms.
|
|
The Activa Sensor Array provides fl ow,
temperature and pressure signals in a compact
unit that requires only one hydraulic line break.
Each sensor transmits an output signal that is
easily integrated with PCs, PLCs, recorders or
panel displays. Signals can also be transmitted to
Flo-tech’s F6700/F6750 Series digital displays.
|
|
Analog Signal Transmitters via Radio RDT-4000
Many times is needing to have several measuring points distributed in plant or in field, in these applications the wired cost is often higher than the original instruments fare. The solution is feasible at present thanks to free band radio transmitters. The RDT-4000/... is the state-of-art all in one devices, capable to read up to two analog mA, mV, Pt100, Pulses, etc., variables and to transmit them via Radio from 250 devices max., in peer-to-peer or multipoint modes, to a radio-modem RMT-1000 linked by RS-485 or USB to a PLC or PC .
|
|
Analog two-wire transmitters are used for direct connections of thermocouples or resistance thermometers. The design for thermocouples has a built-in reference junction and is available for a multitude of thermocouple types.
The transmitter converts the signal from the temperature sensor into a standard signal of 4 ... 20 mA (current loop). Depending on the design the signal is displayed temperature-linear (resistance thermometer) or EMF-linear (thermocouple).
|
|
|
|
|
|
WAN and LAN TRANSMITTERS for analog variables
with WiFi or Fast-ETHERNET interface
The WDT-4000/... and EDT-4000/... series are LAN-transmitters with interface
WiFi or Fast-Ethernet, including an integrated circuit board for
direct input signal and data acquisition with internal processing of field
variables located near to an access point. Suitable for acquisition and
trasmission by LAN of analog variables in SCADA systems.
WiFi or Ethernet
. ANALOG SIGNALS TRANSMITTER BY LOCAL AREA NETWORK
. 2 x Pt100, mV, 0...4-20 mA, (1) THERMOCOUPLE CJC INPUTS
. 1 x PULSE-COUNTER AND FREQUENCY INPUT
. SPECIFIC VERSIONS FOR CHEMICAL VARIABLES, HUMIDITY, ELECTRIC, LEVEL, PRESSURE, FLOW, VIBRATION, ETC.
. WDT-4000/.. : WiFi COMMUNICATION WITH 1/2 WAVE ANTENNA
. EDT-4000/.. : Fast-ETHERNET COMMUNICATION WITH RJ-45
. RS-485 MODBUS COMMUNICATION AS STANDARD
. ENCLOSURE RATING IP65 FOR FIELD MOUNTING
. POWER SUPPLY 85...265 Vac or 12 / 24 Vdc (OPTION)
. MOUNTING ON WALL OR ON PIPES UP TO 2" (50 mm)
. PROGRAMMABLE BY INNER KEYPAD OR BY LOCAL AREA IP-65
|
|
|
|