ORBISPHERE 3620 Series
Gas Analyzer
Dual channel analyzers designed to work with two Orbisphere patented sensors. Available in wall-, rack- or panel-mounted versions for online measurement or portable version. Designed for optimum measurement and control in harsh environments. Performs equally well in low and in high concentrations, in liquid or in gas phase
3620 for CO2 and N2 monitoring for beverage processing.
3621 for O2 and CO2, N2 or H2 monitoring for beverage processing or power generation
3622 for H2 and N2 monitoring for power plants
3623 for O2 and H2 monitoring for nuclear power plants
|
|
| Laser based photoacoustic instruments for continuous monitoring of pollutants in natural gas in biogas and in the atmosphere. Measurable components include: water-vapor, hydrogene-sulfide, ammonia, methane, various types of aerosols etc. |
|
H2scan’s Series 700 in-line hydrogen-specific process monitors are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 700 is a solid state sensor that can operate in humidity and process gas streams with temperatures up to 100ºC. The HY-OPTIMA™ 700 is ideal for hydrogen production and petrochemical applications where real time measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.
Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen by volume at 1ATM
Typical Response Time: T90 less than 30 sec
Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Accuracy: ± (3.0% of indication + 2000ppm)
Interface Options
Input Voltage Range: 8VDC to 13VDC
Input Current: 0.5A
Analog Outputs: 4-20mA
Serial Communication Options: RS232 or RS422
Relay Contacts: Two programmable 60VDC/1A
SPDT relays with both normally open (N.O.)
and normally closed (N.C.) contacts.
Operating Conditions
Operating Humidity: 0% to 95% RH
Flow Rate: 0.1slpm to 50slpm
Pressure: 0 to 7bar gauge, 0 to 100psi gauge
Process Gas Temperature Range: -20ºC to 100ºC
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 50ºC
Calibration Background Gas: Nitrogen
|
|
The new Rapidox 3100 incorporates a powerful and silent linear piston pump for remote sampling of gas. Connections are made using 6/4mm flexible tubing to the front panel input and output unions. The front panel includes a flow gauge allowing the user to control the rate of gas flow into the analyser from 0 to 4 litres per minute.
From the display to the outputs, all features are fully user-programmable using the keypad on the front panel. Easy to use and simple to calibrate using your choice of gases, the Rapidox 3100 offers exceptional performance and flexibility using a rugged, long-life zirconia oxygen sensor. The Rapidox now comes with powerful Windows software for easy data-logging and graphing. Just switch on and start measuring...
-Bench mounted zirconia oxygen analyser with internal sensor & sample pump
-Rapid response long-life sensor
-Sample flow rate adjustable from 0 to 4 litres per minute
-Suitable for applications where the gas must be sampled remotely
-Gas is sampled through flexible tubing connected to the front of the analyser
-Perfect for analysis of room air or difficult to access locations
-Perfect for static gas applications
-Not suitable for hot gas analysis (i.e. >150°C at point of entry into analyser) |
|
| The Series 9500 Oxygen and Carbon Dioxide Monitor is designed to provide continuous, unattended monitoring of both oxygen and carbon dioxide. |
|
Series 200ACE Acetaldehyde Analyzer
Meets ISBT Method 11 criteria for selective measurement of acetaldehyde in CO2
- Rugged, low cost, low maintenance, turn-key system
- Capable of PC-based control and data logging
- Batch or continuous stream monitoring
- Detector: Flame Ionization Detector (FID)
- Automatic, hands-free calibration, flow setting and analysis
- Detection limits for acetaldehyde of < 30 part-per-billion (ppb)
- Instrument operating temperature: ambient
- Detector temperature: factory set; adjustable
- Oven temperature regulation: factory set with software controlled conditioning
- Tested against virtually all of the potential alcohol and oxygenate impurities that could be present and determined to be interference-free
- Acetaldehyde is captured by the software system, with results displayed digitally on the instrument's front panel
- On-board software package contained in the Series 200ACE allows complete unattended operation
- Installation: bench or 19" rack
- Power: 115-230 V, 50-60 Hz |
|
Series 200AHC Aromatic Hydrocarbon Analyzer
Specific detection of benzene within beverage-grade carbon dioxide.
Trace aromatic impurity monitoring is of critical importance to carbon dioxide manufacturers and the carbonated beverage industry. The Series 200 AHC meets all ISBT Method 12.0 criteria for selective measurement of benzene in carbon dioxide. Continuous stream or batch sampling operations are readily performed.
The Series 200 AHC is specifically designed as a rugged, low cost, low maintenance, simple to operate, turn-key system. No cylinder support gases are needed. Calibration and sample introduction are totally automated. A newly designed photo-ionization detector (PID) and proprietary technology are used for the specific measurement of benzene without interference from other potential impurities in beverage-grade carbon dioxide. Detector response is linear over three orders of magnitude. The detectable limit for benzene is 3 ppb, which is far below the ISBT guideline limit of 20 ppb. GOW-MAC’s Series 200 AHC system is also capable of PC-based control and data logging. Full documentation is provided, along with optional customer training and support services.
|
|
Series 200BTEX Gas Analyzer
Meets all ISBT Method 12 criteria for selective measurement of BTEX (benzene, toluene, ethyl benzene, o-xylene, m-xylene, and p-xylene) in CO2
- Rugged, low cost, low maintenance, turn-key system
- Features: Auto-Calibration, Auto-Calibration Validation, Process/Manual mode, As Found/As Left function, Sample stream selection, and six 4-20 mA outputs
- Capable of PC-based control and data logging
- Batch or continuous stream monitoring
- Detector: Photo Ionization Detector (PID)
- Automatic, hands-free calibration, flow setting and analysis
- Detection limits for benzene of < 5 ppb
- Instrument operating temperature: ambient
- Detector temperature: factory set; adjustable
- Oven temperature: factory set with software controlled conditioning
- Tested against virtually all of the potential alcohol and oxygenate impurities that could be present and determined to be interference-free
- Benzene is captured by the software system, with results displayed digitally on the instrument's front panel
- On-board software package contained in the Series 200AHC allows complete unattended operation
- Installation: bench or 19" rack
- Power: 115-230 V, 50-60 Hz |
|
Test flue gasses at home or office spaces for the
presence and location of CO leaks. With a protective
rubber boot, the new 707 fits comfortably in your hand and operates with the push of a button.
- Clear and fast response with advance pump
driven technology.
- Peak Hold to capture peak CO reading.
- Instrument recycles and will not shut off if 15ppm CO
is present, increasing safety.
- Store Button allows you to save up to eight readings and
then print using the IR port and optional A740 printer.
- 1 ppm sensitivity.
- Measures up to 10,000ppm.
- Push on fittings are fast and easy to use.
- Large easy to read backlit display.
- Advanced electrochemical sensor is field replaceable
and calibrateable.
- Protective rubber boot and soft carrying case with shoulder strap is
included. |
|
| AMETEK Western Research’s UV-VIS photometric analyzers are recognized worldwide offering excellent performance and reliability for continuous monitoring of pollutants emitted from refineries, chemical plants, power plants, and other industrial facilities. Western Research has the full system design and manufacturing capabilities needed to engineer a turn-key solution to meet your requirements. |
|
Teledyne%u2019s hand-held GB300 Portable Percent Oxygen Analyzer is designed for use in a wide variety of applications from diving to fine tuning boilers.
Lightweight and easy to use, the GB300 incorporates Teledyne%u2019s own Micro-fuel Cell sensor for quick and accurate analysis of oxygen.
This maintenance-free, sealed, electrochemical cell is specific to oxygen, insensitive to flow rate, and has a 90% response in less than 10 seconds. At the end of its life, the cell is discarded and replaced like a flashlight battery.
Constructed of high impact resistant materials, the GB300 provides unparalleled performance under the harshest conditions. The unit is powered by 3 AA batteries which should last for at least 2000 hours of use. |
|
Designed for measuring simultaneously up to three gases with NDIR technology with correlation cells. Typical gases are CO, NO, CO2, CH4, SO2, etc. No regular service needed, it executes automatically zero autocal with ambient air. This analyzer is equipped with 4 analogical output (4-20 ma) and 2 serials (mod-Bus RTU/ASCI), double threshold contact alarm for every measurement, fault and service. A special version with a long optical path allows the measure of extremely low amounts.
4 optional analogical input 4-20 ma and 6 digital input make it the perfect controller for every analysis system (CEMS). European certification in progress.
Hart protocol available as option.
|
|
In order to permit the measurement and the continuous control of smokes generated by the combustion of natural gas, fuel oil, coal or garbage, Fuji Electric has developed a complete line of gas analysers allowing to adapt all industrial facilities to the standards and regulations limiting the disposals of pollutants in the atmosphere.
|
|
Applications: for controls and the complete analyzes of the industrial and domestic boilers, you will be able to store the series of measurement and to exploit them on PC.
Answers reference frame QUALIGAZ
2 cells O2 and CO
2 optional cells NO (Nox), NO2, SO2 with the choice.
O2, CO2, CO, CO of smoke, ambient CO Peak, NO, NO2, Nox, SO2. Room temperature, of smoke, Delta T ECS.
T Departure and T return
Differential pressure, Delta P
Excess of air, Losses, Output
Index of opacity
Current of ionization
Sealing of the gas network
5 preprogrammed fuels: natural gas, heavy fuel, domestic fuel, butane, propane.
5 other fuels can be programmed on request.
Impact printer integrated with standard paper (not thermics).
Memory size of 250 series of measurement.
Possibility of recording and of printing the indices of opacity.
Comparison between O2, CO2 and excess of air (Lambda)
Integrated room temperature, of smoke and differential T.
Detection and localization of the gas leaks.
Manual switch or automatic of protection of the cell CO.
Indicator of wear of the state of the cells.
Food: refillable battery or sector 230 Vac.
Delivered in a case, with note of use and certificate of calibration. |
|
Model CEA-9001 Flue Gas Analyzer & PEM-9002 Portable Emissions Monitor
The CEA-9001 is a digital, hand-held, flue gas analyzer featuring state-of-the-art microprocessor technology.
Ideally suited for inspecting and servicing small and medium sized heater installations, it is used for safety-relevant technical inspections of CO emission concentrations in gas combustion plants.
The CEA-9001 offers storage of 100 complete blocks of measurement data which can be printed directly via an IR printer or processed through an appropriate PC program.
Optional upgrades are available for up to three measurement cells -- O2, CO, and NO -- which allows for CO measurement with H2 compensation, waste gas temperature, O2 / CO2 content, and combustion air temperature measurement.
The CEA-9001 is available with a light weight yet rugged carrying case. |
|
A complete range of flue gas oxygen analysers for all applications
Genesis is a range of flue gas oxygen analysers developed specifically for combustion analysis and control applications. Unrivalled flexibility and ease-of-use enables the Genesis oxygen analyser systems range to meet all process requirements.
The range of Oxygen Analysers for General Purpose Applications includes in-situ measurement probes for a wide range of flue gas temperatures (0 - 1250 °C / 32 - 2282 °F), local and remote control units, and an automatic calibration unit.
The 'stand-alone system' is the world's first truly, This oxygen analyser also carries TÜV approval.
|
|
| New analyzer who has the absolutely new characteristic of direct in situ oxygen measuring in processes with various and variable temperatures. The probe, realized in ceramics, can be used in every type of process. The special cell heater is not be damaged also with high temperatures of the process. |
|
Binary Gas Analyzers
The 20 Series Gas Analyzer with thermal conductivity detector (TCD) is designed for non-continuous sampling and quantitative analysis of binary process streams of industrial gases and other gas mixing, cylinder identification, and atmospheric control applications.
The 50 Series Continuous Duty Gas Analyzer with thermal conductivity detector (TCD) is custom designed to your specific requirements. The analyzer contains a temperature regulated TCD which enables it to be used in continuous monitoring applications with minimum zero drift. Typical applications involve continuous monitoring of gas streams for low ppm impurity.
Both Analyzers:
- Optimized, Self-Contained Gas Flow System
- Built-in Gas Selection Manifold
- Custom Designed to Your Application
- Choice of standard, corrosion resistant or all stainless steel system
- Class 1, Div 1, Group B, C, D Class 1, Div 2, Group B, C, D available systems
We specialize in manufacturing custom engineered analyzers, therefore, we ask you to give us your specific application parameters in order to quote the appropriate analyzer for your needs.
|
|
Gasmet In - Lab Series includes quantitative
multicomponent gas analyzers for laboratory
research applications. The Gasmet Cr - Series
incorporates a Fourier Transform Infrared, FTIR
spectrometer, a temperature controlled sample
cell, and signal processing electronics. Liquid
nitrogen cooled MCT detector has the highest
performance available.
The Gasmet Cr-2000 is designed for speed and
reliability. It is an ideal tool for example for motor
exhaust measurements, catalyst research
applications, pyrolysis research, or to measure any
compounds in wet corrosive gas mixtures. The
small volume of the sample cell provides short
response times. The gold-coated sample cell can
be heated up to 180ºC. Various sample cell path lenghts are available (from 1 cm to 100 meters). |
|
Attaining New Dimensions
The multi EA 3100 represents a new generation of elemental analysis systems for determining C, N, S, Cl content. The hitherto unattained diversity of modules for sampling and detection opens up new horizons in elemental analytics.
This multi-matrix capable analysis system allows solids, liquids, gases and LPGs to be investigated without time-consuming hardware reconfigurations or recalibration of the measurement system. Even the most difficult matrices, such as oils, fuels, solvents, polymers, coal, liquid gases, EOX, AOX etc., can be investigated quickly and reliably.
Simple operation, minimal maintenance requirement and premium measurement result precision thanks to the integrated self-check system and flame sensor technology.
Thanks to its unique double furnace technology, vertical or horizontal sample insertion modes are combined in a single instrument thus saving space.
- "Multi Matrix" - solid, liquid and gaseous samples
- "Multi Element" - C, Cl, N, S determination
- "Multi Application" - TC, TN, TS, TX, AOX shaking and column method, EOX etc.
- "Double Furnace Technology" - vertical and horizontal modes in a single instrument
- Unrivalled measurement range - ultra-trace to mass percent
- Modular construction -also allows subsequent expansion of the analysis system to include detection and sampling systems
- Use-friendly plug-and-start connection technology for add-on modules
|
|
Series 3000T - Trace Oxygen Analyzers
The Series 3000T Trace Oxygen Analyzers provides powerful microprocessor technology while offering tremendous versatility in the low ppm ranges. This instrument offers three user-selectable linear ranges, high accuracy, fast response, adjustable alarms, and auto diagnostics.
No zero gases are required in most applications. The heart of the analyzer is a specially qualified Micro-fuel Cell designed to measure oxygen in the gas sample.
The sensor is unequaled in the industry for its accuracy, sensitivity, and reliability. The instruments can be used as a separate unit or as a component of a larger analytical system. |
|
| The Series 3000 Trace Oxygen Analyzers are rugged, microprocessor-controlled instruments designed for continuous or intermittent measurement of trace concentrations of oxygen. The Series 3000 Trace Oxygen Analyzers are available in single or three ranges, from 0-1 to 0-10,000 parts per million (ppm). |
|
| Zirconium oxide-based trace oxygen analyzers monitor oxygen concentration from PPB to % levels. Applications are wide ranging and include semiconductor rapid thermal processing, inerting/purging using N2, Ar, CO2 or He, UV curing, and specialty welding. The analyzers offer a very fast response, are unaffected by exposure to air and will not fail to zero oxygen reading. |
|
| Designed for the measure of oxygen traces in processes with protection atmospheres. Extremely low oxygen measuring also available. |
|
The Series 3500 Trace Oxygen Transmitter is a true two-wire transmitter offering an economical way to make accurate and dependable measurements of trace oxygen in a variety of gases.
The Series 3510 Trace Oxygen Transmitter is the AC powered counterpart of the Series 3500 |
|
LAND has a range of portable gas analysers for testing, checking and monitoring combustion processes for operating efficiency; and analyzing pollutant gas emissions for environmental compliance.
The range comprises lightweight, simple-to-use portable gas analysers with facilities aimed at a wide range of applications. Up to 9 gas measurement are available on a single analyser. There are a wide range of options available, including a data acquisition system - plus the ability to self-configure the analyzer to exactly meet plant and process requirements.
|
|
Measuring parameters:
O2, CO / H2, (NO, SO2 and / or CO-high optional), waste gas temperature, ambient temperature, draft or balance pressure.
NOTE: NO2 measurements are not possible.
Computed values:
CO2, CO non-diluted, Lambda, pressure and temperature difference, degree of efficiency (Eta), waste gas losses (qA), NOx, dew point, and Eta combustion value
This lightweight design incorporates many features including:
Powerful storage battery; approximately 30 hours of operation with activated display illumination
Illuminated display showing four simultaneous measuring values in a selectable display combination
Optional upgrades for up to five measuring cells: O2, CO / H2, CO-high, NO, SO2
Integrated printer for plain paper - measuring data can be printed immediately |
|
708 Combustion Efficiency Analyzer
1. Combustion Efficiency Analyzer
• Measure 02 and CO
• Calculate CO2, efficiency, excess air and ratio.
• Will work with high efficiency furnaces, hot water
heaters, and other combustible gas appliances.
2. CO Analyzer
3. Differential Thermometer
709 Combustion Efficiency Analyzer w/ Differential Digital Manometer (0.001 inH20)
1. Combustion Efficiency Analyzer
• Measure 02 and CO
• Calculate CO2, efficiency, excess air and ratio.
• Will work with high efficiency furnaces, hot water
heaters, and other combustible gas appliances.
2. Differential Digital Manometer
3. CO Analyzer
4. Differential Thermometer
712 Flue Gas Analyzer
1. Combustion Efficiency Analyzer
• Measure 02 and CO
• Calculate CO2, efficiency, excess air and ratio.
2. Combustible Gas Detector
3. CO Analyzer
• Measure 0-10,000 ppm CO
4. Differential Thermometer
5. Differential Digital Manometer
714
1. Combustion Efficiency Analyzer
• Measure 02, CO, and NO
• Calculate CO2, NOX, efficiency, excess and air ratio
2. NO & NOX Analyzer
3. CO Analyzer
4. Differential Thermometer
5. Differential Digital Manometer
|
|
At the heart of Gasmet Portable Measuring System is the Gasmet DX-4000 portable FTIR gas analyzer. This analyzer has a sample cell that is heated to 180 degrees centigrade. Hot extractive sampling ensures reliable measurements for water soluble compounds such as HF, HCl, and ammonia. Up to 50 different compounds can be measured simultanously. Gasmet portable measuring system requires no gas drying, cooling, or dilution. Hot-and-wet sample gas is simply directed to the heated and corrosion resistant sample cell after particle filtration. Gasmet hot extractive portable sampling system is equipped with comprehensive safety features, which automatically stop sampling and flush the analyser in the case of a power loss. Additionally, a zirconia cell (ZrO2) can be added for Oxygen analysis.
Gasmet portable measuring system not only provides accurate measurement of water soluble compounds, but also provides very accurate measurement for water vapour. Gasmet portable measuring system can cope with and measure in up to 50 vol-% water concentrations.
Gasmet portable measuring system is the right tool for stack testing, ensuring high quality measurements in all conditions.
|
|
|