|
|
In order to permit the measurement and the continuous control of smokes generated by the combustion of natural gas, fuel oil, coal or garbage, Fuji Electric has developed a complete line of gas analysers allowing to adapt all industrial facilities to the standards and regulations limiting the disposals of pollutants in the atmosphere.
|
|
A complete range of flue gas oxygen analysers for all applications
Genesis is a range of flue gas oxygen analysers developed specifically for combustion analysis and control applications. Unrivalled flexibility and ease-of-use enables the Genesis oxygen analyser systems range to meet all process requirements.
The range of Oxygen Analysers for General Purpose Applications includes in-situ measurement probes for a wide range of flue gas temperatures (0 - 1250 °C / 32 - 2282 °F), local and remote control units, and an automatic calibration unit.
The 'stand-alone system' is the world's first truly, This oxygen analyser also carries TÜV approval.
|
|
The Monitor 90 Ecometers are used to measure gaseous inorganic chorine, fluorine or ammonium compounds.
They are ideal for process monitoring and emission control, and comply
to the requirements of the German emission control regulations
(BImSchV) - among the strictest in the world. The high system availability makes the Ecometer an ideal component of automatic control systems for emission control installations.
Advantages:
-Minimal reagent consumption
for low operating costs
-Low maintenance, with selfchecking and automatic recalibration
-Automatic correction for
sample pressure and temperature
-Low sensitivity to interference,
below statutory requirements
-High stability, with low standard deviation and drift
-Industry standard interfaces and outputs
|
|
The PowerMon Ionometer is a versatile applicable on-line measuring instrument, which is used for the monitoring of the legally prescribed limit value in the outlet of municipal and industrial purification plants.
Advantages:
-precise results
-connection of up to 100 external,
physical measuring sensors
-fully automatic operation
-easy, comfortable operation
-fast data transfer
-self-monitoring system
-remote maintenance and
network ability
-graphic user interface with interactive
Touch Screen operation
-update of the operating software or
download of data by USB stick
-minimum operating cost by small
reagent consumption
-second measuring point
without surcharge
-operation also possible
without housing
|
|
These analyzers and sensor assemblies are suitable for measuring fluoride concentration typically found in drinking water applications and are a simple, cost-effective solution for ensuring regulatory compliance in fluoridated drinking water.
Benefits:
- Low price
- Low maintenance
- No chemical additions
|
|
ANTEK's 9000F offers a cost-effective alternative to the common Wickbold method (oxy-hydrogen torch) of analysis, providing total fluoride determinations on gas, liquid, and solid samples safely within minutes instead of hours. It is far less expensive than ICP/MS; and, unlike other methods, the ANTEK 9000F is specific for fluoride without interference from other halides. The safe, non-hazardous ion specific detection method provides an analytical range from sub-ppm to percent levels.
Features & Benefits
- Specific for fluoride
- Sensitivity from sub-ppm to % levels
- Results in 5 to 15 minutes
- Non-hazardous operation
- Gas, LPG, liquid, and solid samples
|
|
Analysis Cabinet, Multigas, Turn On Key
Description :
- Study, Designe and Production of an analysis system where are integrated several kinds of analyzers (ARELCO or other), and a sampling system (manual or automatic).
- Exemple : Gas Analysis in furnace atmosphere for heat treatment application (Steel Industry, Glass Industry).
ARELCO offers global solution for gas analysis in galvanizing line, annealing line, reheating furnace (CGL, CAL, ...).
Measured Gas in this application : O2, H2, dewpoint
|
|
|
|
|
|
Gasmet CR-series are desktop analyzers for high sensitivity, high speed gas analysis. The CR-series FTIR gas analyzers are especially suitable for vehicle exhaust measurements, catalytic research, gas purity tests and other research applications.
The liquid nitrogen cooled MCT - detector in the CR-series offers the lowest possible detection limits and shortest measurement times. Large selection of different sample cell path lengths (from 1.0 cm to 10 m) is also offered in order to suit different measurement needs. Gasmet Technologies can also supply customized sampling units to match different requirements.
There are three different CR - models available:
CR1000:
Gasmet™ CR1000 FTIR gas analyzer features a stainless steel single pass sample cell for highest measurement ranges (vol - %). Sample cell is heated (as standard 180 °C) in order to keep the sample in gas phase.
CR2000:
Gasmet™ CR2000 FTIR Gas Analyzer has a small volume sample cell which combined with the LN2 cooled detector makes it an excellent instrument for very fast measurements. Typical uses include vehicle exhaust measurements where short response times and high sensitivity are needed.
CR4000:
Gasmet™ CR4000 FTIR Gas Analyzer has a high-sensitivity sample cell and a LN2 cooled detector which give lowest possible detection limits. It´s therefore well suited for applications where very low levels of detection are needed.
|
|
|
|
|
|
U.S. EPA approved gas analyzers available with Ozone O3 analyzer, Carbon Monoxide CO analyzer, Oxides of Nitrogen NOX analyzer and Sulfur Dioxide SO2 analyzer.
The new Serinus series is the next generation of gas analyzers from Ecotech,
a leading manufacturer of environmental monitoring solutions. Completely
redesigned and incorporating innovative technology, the Serinus series will
deliver:
• Superior performance
• Low total cost of ownership
• Reduced maintenance intervals
Key features across the Serinus series include:
• Interchangeable components, consumables, spare parts and accessories, keeping operating and service costs low
• A low carbon footprint due to reduced power consumption and operation over a wider temperature range
• Use of zero volume fittings and flexible teflon tubing improves system integrity
• Redesigned electronics suite delivers greater stability and reliability
• Removable flash memory stores up to eight years of one minute data, including the ability to record up to 16 individual parameters, instrument settings and event logs
• Optional dual particulate filter can reduce scheduled on-site maintenance visits by up to 50%
• Intuitive Quick Menu and easier to read Graphical User Interface (GUI) simplifies instrument operation
• New advanced diagnostics protocol with detailed event tracking and convenient ‘Traffic Light’ analyzer state indicator
• Full remote control of instrument functions including calibrations, span/zero checks and diagnostics
|
|
The Andros 6500 offers unparalleled accuracy and performance exceeding its
predecessor, the Andros 6602, which has held the reputation as the highest performing system available for many years. Now taking advantage of the latest technology, Andros brings you a product with superior performance and reliability.
The Non-Dispersive InfraRed system (NDIR) measures gases, controls pneumatic components, communicates via RS-232 or USB with the host, and provides user-defined TTL outputs, as well as analog inputs and TTL Pulse Counter which can be integrated into the data output stream for user convenience.
|
|
|
|
|
|
RMT Ltd produces modular NDIR gas analyzer DX6100 Series. It is the second generation of gas analyzers after DX6000 model.
DX6100 gas analyzer is based on new integrated detector-emitter pair . The pair (optopair) is integrated into one housing with built-in thermoelectric cooling module. This solution provides high sensitivity, accuracy of operation.
Modular concept and universal solutions allow to supply analyzers for several gases: CO2, CH4, hydrocarbons.
- It is a cost-effective solution for application where accurate gas concentration measurements are required.
- Miniature design is suitable for field applications as well as for laboratory and indoor purposes.
- Friendly and and open for users architecture
- Two program levels for access: remote control through RS232C protocol using a developed set of external commands; RMT's analyst software for realtime operation is included into standard option.
- The instrument includes a basic datalogging function and continuous output facility to remote device (PC or indicator).
- The DX6100 is insensitive to partial non- transparency of measuring gas (smoke, etc).
- It operates well in wet conditions up to 100% of humidity
|
|
|
|
|
|
Real-Time Gas Analyzer Products from MKS
FT-IR, NDIR, Infrared, Mass Spectrometry, and Residual Gas Analyzer products for Continuous Gas Analysis, Process Monitoring, Stack Emissions, Trace Impurity Detection, Continuous Emissions Monitoring (CEM), Formaldehyde Emissions Monitoring, and Exhaust Gas Analysis
FTIR, NDIR Infrared Gas Analysis Products:
MultiGas™ FTIR-based analyzer products from MKS On-Line Products are capable of ppb to ppm sensitivity for multiple gas species in a variety of gas analyzer applications, such as:
- stack emissions monitoring,
- continuous emissions monitoring (CEM),
- process monitoring,
- formaldehyde emissions monitoring,
- purity monitoring,
- automobile, diesel, and catalyst exhaust monitoring.
InDuct™ FTIR-based gas sensors are used for fault detection, monitoring, control, or endpoint determination.
Process Sense™ is a chamber clean endpoint detector that lowers cost and increases productivity by accurately identifying the end of the chamber clean step in semiconductor and flat panel deposition chambers.
Mass Spectrometry
MKS Mass Spectrometry gas analyzer products are innovative in-situ process monitoring instruments that are fully integrated, application-specific packages, including component residual gas analyzers (RGAs), web-enabled RGA's, analytical equipment, and process RGAs and control software.
- Vacuum Monitoring and e-Diagnostics
- Ultra High Vacuum (UHV)
- CVD Processes
- Vacuum Baseline RGA
- Ion Implant
- Photoresist Detection
- High-Pressure RGA
|
|
The analyser 2008 IR P is dependable and competitive, it is used to measure CO2 punctually (either CO or CH4) in all your techniques.
This portable analyser inserts a pomp of prélevement as well as a filter of porosity 0.1µm optional
|
|
|
|
|
|
Modified Atmosphere Analyser (Portable) - MAPtest 800
- Rapid response time
- Low maintenance and calibration requirements
- Timed pumped sample
- Up to thirty hours running time between battery charges
- MAP/CAP (modified and controlled atmosphere packaging) techniques
The MAPtest 800 portable modified atmosphere packaging analyser has been designed specifically for measuring oxygen concentrations over a wide range of food packaging and storage atmospheres. Based on a galvanic cell sensor which is unaffected by the presence of carbon dioxide, the unit offers a high degree of accuracy across the range 0 to 100%, and can be calibrated easily on air.
Applications:
- Modified atmosphere packaging companies
- Modified atmosphere packaging tester
- Modified atmosphere packaging
- Gas ratio for modified atmosphere packaging
- Modified atmosphere sterilized packaging
- modified atmosphere sandwich packaging
- modified atmosphere packaging investment
- modified atmosphere carbon monoxide packaging
A sample probe or a syringe, both of which are supplied with the analyser, is used to introduce the sample. When the probe is used an in-built pump, activated from the front panel, draws the sample through the probe into the analyser. The pumped volume is adjustable allowing measurements from different pack sizes. Once a measurement is made the result is shown and held on a large 3½ digit display.
|
|
CheckPoint - for testing modified atmosphere packaging (MAP). Small ergonomically designed handheld analyser for oxygen and carbon dioxide quality control of modified atmosphere packages.
Battery operated with either standard AA batteries or a rechagable battery pack. Memory function, large easy readable display and a sturdy aluminium housing.
CheckPoint is available in two versions:
- CheckPoint O2 for oxygen only
- CheckPoint O2/CO2 for combined measuring of oxygen & carbon dioxide
Benefits of the PBI-Dansensor CheckPoint:
- Simple to use
- Ergonomical design
- Easy gas content indication for modified atmosphere packages
- Cordless and easy to transport
- CO2 measurement is temperature compensated
- O2/CO2 model compensates oxygen reading for carbon dioxide content in applications with high CO2 content
|
|
|
The analyser from ARELCO A.R.C. model CATARC MP - R integrates a sensor which works on the principle of thermal conductibility and a very powerful electronics with microprocessor. It is designed for monitoring and checking binary gas blending like H2/N2, He/N2, SF6/air, ...
|
|
H-Sense
Hydrogen Gas Analyzer
One of industry's first, true, on-line hydrogen gas analyzers. By utilizing standard MS techniques, coupled with a unique gas handling system, the H-Sense is proven to be a powerful, high speed, direct emission, hydrogen gas analyzer.
The mobile analyzer boasts a number of advantages:
Electron Pulse Ionization (EIMS) mass spec principle optimized for H2 only analysis.
Fully integrated gas inlet system compensates for high pressure variations.
High dynamic detection range (low ppm to 100%), highest degree of flexibility, ruggedized for any industrial or laboratory process.
System contamination from particulate or condensation is eliminated
|
|
|
|
|
|
Fast, non-intrusive measurements of gas concentrations and temperatures, performed inside of the process itself are the domain of the diode laser gas analytic. The gas analyzer LDS 6 which combines the compact and service friendly set-up, the easy operation and the network connectivity of Series 6 with the known unique performance of diode laser based in-situ gas analytics.
Fibre optics and IR diode laser technology, standard components of high quality and reliability in communications engineering, give an extremely robust analyzer concept almost free of maintenance which enables process relevant information even under very harsh environmental or process conditions. A build-in hands-off reference gas cell avoids the need for any test gases in the field. By the means of a simple analogue modem a remote control or diagnosis of the analyzers is possible (almost) anywhere and anytime.
Today, the list of gases able to be measured with NIR diode lasers contains already gases like O2, NH3, HCl, HF, H2O, CO, CO2, H2S, CH4, ... and it is continuously growing with the state of the development in semiconductor laser technology. Additionally, high gas temperatures can be determined non-intrusively with an O2 measurement.
|
|
|
|
|
|
The MAP Check Combi II can be fitted onto most vertical and horizontal flow packgaging machines. The analyser can be fully integrated with the packaging machine, thereby ensuring that the packaging process is stopped if the required gas content is not present in the packages. In the PFC (proportional flow control) version of the MAP Check Combi II, gas savings of up to 25% are possible.
The MAP Check Combi series secures the quality in Modified Atmosphere Packaging through on-line measuring and recording of the gas content in the package before sealing.
MAP Check Combi is tested to be in compliance with EU regulation 1935/2004 on materials and articles intended to come into contact with food.
Other features:
- Extremely fast responding sensors
- Packaging machine interface
- Large userfriendly touch screen display
- Calibration intervals: 1 year
- Documentation of tests
- 99 set-up programs
- MCC is delivered with a stainless steel cabinet, and MCC II is delivered with a anodized aluminium cabinet
- Each package is tested
- Secure uniform quality in MAP
- User-dependent faults are minimised, and the product requires low maintenance
- Easy to operate
- Designed for both vertical and horizontal flow packaging machines (flow wrappers)
|
|
Features
Maintenance-free (6 months) dry reactor
High operational safety
Easy maintenance
Low cross sensitivities
Easily legible LC display
Applications
Waste incinerations (municipal waste, industrial waste, hospital waste)
Sewage sludge incineration
Hazardous waste incineration
Steel plants with scrap metal preparation
Contaminated soil burning plants
Crematoriums
Mercury mines and refineries
Fluorescent light bulb recycling plants
|
|
The Tekran® Model 2600-NG Mercury Analyzer is designed for the analysis of gas phase sample cartridges. The system contains an atomic fluorescence detector, a dual stage thermal desorber and a data acquisition and control system. A single serial connection allows a Windows based PC to control the entire analysis process, acquire the detector output and calculate final results
Key Features
- Dedicated analyzer for manually exposed sampling cartridges.
- Sample path optimized for difficult matrices.
- Desorbs industry standard .25” OD x 5” to 6” long friction fit cartridges.
- Ultra sensitive Atomic Fluorescence (AF) detector.
- Dual stage gold preconcentrator/thermal desorber.
- Precision mass flowmeter gives superior long term stability.
- Auto carrier shutoff to conserve carrier gas
|
|
The Tekran Model 2537 Mercury Vapour Analyzer provides continuous analysis of total gaseous mercury (TGM) in air at sub-ng/m3 (parts per trillion (ppt) and parts per quadrillion (ppq)) levels.
The instrument samples air and traps mercury vapour into a cartridge containing an ultra-pure gold adsorbent. The amalgamated mercury is thermally desorbed and detected using Cold Vapour Atomic Fluorescence Spectrometry (CVAFS). A dual cartridge design allows alternate sampling and desorption, resulting in continuous measurement of the air stream.
Key Features
- Patented dual cartridge design.
- Capable of unattended operation for extended periods.
- High precision mass flow meter provides accurate measure of total sample volume.
- Ultraviolet excitation source is temperature controlled and features closed loop optical intensity control for optimum stability.
- Simple menu based operation allows modifications of all operational parameters to suit any monitoring application.
|
|
|
|
|
|
The Advance Optima process gas analyzers have a modular design that increases flexibility and saves money.
Analyzer modules can be combined into tailor-made solutions and upgraded to new features at any time.
Remote modules are easily attached and centrally operated.
One central unit and various analyzer modules
- with common controls
- with a common connection technology
- in a common system housing
All analyzers use high performance measurement technology and simplified calibration that doesn't require test gas bottles.
- Photometers
- In-Situ Laser Analyzer
- Oxygen Analyzers
- Trace Oxygen Analyzer ZO23
- Thermal Conductivity Analyzers
- FID Analyzers
read more...
The AO2000 analyzers provides Ethernet, TCP/IP interfaces. An OPC server is available. Profibus DP/PA and Modbus interfaces are available.
AO2000 system components are available with GOST-R certificates as with CSA approval for Class I Division 2 and ATEX approval for installation in Zone 1 or Zone 2.
For measuring flammable gases in hazardous locations the AO2000 series provides a safety concept with built-in purge control and alarm monitoring.
|
|
|
|
|
|
3 Gas - Landfill Gas Monitoring System (Wall Mount) - GIR5000
- For measuring oxygen, methane and carbon dioxide gas
- Alarms for all measurements and sample flow
- 4 to 20mA outputs for all measurements
- Optional safety alarm and shut-down system
The GIR5000 gas landfill monitoring system is a gas analyzer unit for measuring and monitoring the concentrations of oxygen and methane in landfill gas and biogas. As an option, the concentration of carbon dioxide can also be monitored. Used for:
- Landfill gas monitoring devices-methane
- Hazardous components in landfill gas
- Landfill safety
- Landfill gas monitor
- Landfill gas
- Landfill gases
- Landfill health effects
- Landfill pollution
Sample conditioning in the basic unit is provided by an external coalescing filter and water catch-pot assembly. When the external temperature is below 35°C (the internal temperature of the analyser) this technique is the most economic. For situations where the sample temperature at source is significantly higher than the ambient temperature, and the sample is saturated with water, an optional sample cooler can be fitted.
Analogue outputs and alarms are provided for all gases measured.
|
|
9000NS - TOTAL NITROGEN & SULFUR ANALYZER
Our 9000 Series Analyzers use proven technology to perform total nitrogen and/or total sulfur analyses from low ppb to percent levels. Their speed, accuracy, and precision are unrivalled — more stable than coulometric methods, more sensitive than x-ray, safer and faster than Kjeldahl.
These new generation analyzers include a computer with Windows™-based, custom-designed software. Data acquisition, analysis, and storage, as well as programming and control of the analyzer and accessory instrumentation are easy using the user friendly, menu driven interface. Remote instrument operation and real-time analysis support are provided via Remote Access.
|
|
The oxygen analyser model ZOA 100 use a gazeous diffusion micro zirconium oxide cell.
This technic allows a continious or intermittent use with very low maintenance.
The several versions of ZOA 100 are designed to fit the most severe applications.
The unit is also designed to be used as oxygen detector.
|
|
Series 3000T - Trace Oxygen Analyzers
The Series 3000T Trace Oxygen Analyzers provides powerful microprocessor technology while offering tremendous versatility in the low ppm ranges. This instrument offers three user-selectable linear ranges, high accuracy, fast response, adjustable alarms, and auto diagnostics.
No zero gases are required in most applications. The heart of the analyzer is a specially qualified Micro-fuel Cell designed to measure oxygen in the gas sample.
The sensor is unequaled in the industry for its accuracy, sensitivity, and reliability. The instruments can be used as a separate unit or as a component of a larger analytical system.
|
|
|
The Series 3000 Trace Oxygen Analyzers are rugged, microprocessor-controlled instruments designed for continuous or intermittent measurement of trace concentrations of oxygen. The Series 3000 Trace Oxygen Analyzers are available in single or three ranges, from 0-1 to 0-10,000 parts per million (ppm).
|
|
PE 135
Salient Features & Benefits
- Highly sensitive & stable .
- Manual Temperature Compensation
|
|
|
|
|
|
Galvanic In-situ Oxygen Gas Detector Analyzer (Panel Mount) - G1010
- Exceptional high performance dynamic range for oxygen analysis
- Single point calibration
- Broad Range
- Microprocessor-controlled
- Programmable alarms and analogue output
- Hazardous-area models available
The G1010 in-situ oxygen gas detector and analyzer uses a galvanic oxygen cell to measure oxygen over an exceptional dynamic range of 100% to 0.1ppm (parts per million) in a variety of gases. The instruments are microprocessor- controlled and provide exceptional performance and versatility.
A large multi-digit, auto-ranging LCD shows the concentration and user-adjustable parameters.
Two alarm channels, user-programmable to be high, low or off, each provide one set of volt-free changeover contacts, and can be set to any concentration within the span of the instrument.
A user programmable analogue output of 0 to 5v or 4 to 20mA is available at the time of ordering.
Several versions of sensor are available, enabling the analyzer to operate at optimum performance in a diverse range of applications. These include a sensor suitable for operating in the presence of high concentrations of mildly acidic gases such as carbon dioxide and hydrogen sulphide.
|
|
|
|