Primary current: 0.5 A - 100 A
VAC: 240 V - 415 V
... replacement of miniature circuit breakers on the DIN rail. All terminals are Bi-Connect for ultimate flexibility. Deep serrated terminals provide the mounting of cables up to 35 mm² cross-section. The ...
Primary current: 7,150, 6,900 A
VAC: 24 kV
System type generator circuit-breaker (GCB) with innovative built-in monitoring The HVS-63S GCB with SF6 interrupting technology for short-circuit currents up to 63 kA and rated currents ...
Primary current: 2,500 A
VAC: 72.5 kV
Well proven circuit breaker based on established design, assembled and tested for rapid installation The EDF SK is a live tank SF6 Auto-Puffer™ circuit breaker. It has ...
Primary current: 800 A - 6,300 A
VAC: 220, 415 V
Future Ready ! MasterPact MTZ is a comprehensive range of air circuit breakers, to protect from damage caused by overloads, short-circuits or insulation faults. MasterPact MTZ embeds ...
Schneider Electric
Primary current: 630 A - 1,600 A
VAC: 220, 415 V
MasterPact NT circuit breakers are equipped with MicroLogic control units that offer built-in power and energy metering in addition to basic or advanced protection functions. The MasterPact ...
Schneider Electric
Primary current: 800 A - 6,300 A
VAC: 220, 415 V
MasterPact NW circuit breakers are equipped with MicroLogic control units that offer built-in power and energy metering in addition to basic or advanced protection functions. Two sizes ...
Schneider Electric
VAC: 240, 415 V
Rating: 6 A - 63 A
... RECmax MP series are motorized circuit breakers that can be linked remotely.They function as protection against shortcircuit and overload, and can also be used as a circuit ...
Primary current: 6 A - 63 A
VAC: 240, 415 V
... device with circuit breaker and ultra-immunized earth leakage protection. Programmable unit with display, which measures leakage currents (earth leakage protection), and orders the disconnection or ...
Primary current: 1,250, 630 A
VAC: 12, 24, 36 kV
... Good pollution resistance. Description: ZW32-12/24 model outdoor AC vacuum circuit breaker is used to make and break load current, overload current and short-circuit current in ...
Primary current: 1 A - 250 A
VAC: 127 V - 240 V
VDC: 65 V - 250 V
Maximum voltage: 415VAC 50/60 Hz. Current Ratings: 1A to 250A. Operating Temperature: -40℃to +85℃ Number of poles: 1 pole, 2 poles, 3 poles Agency Certifications: UL489A, CCC, TUV
VAC: 230 V
Rating: 2 A - 32 A
Primary current: 25 A
VAC: 230 V
Residual current circuit-breakers (RCCBs) are components for implementing protective measure "Automatic switch-off of power supply" as per VDE 0100 part 410 or corresponding international ...
Doepke Schaltgeräte GmbH
Primary current: 16 A
VAC: 230 V
Residual current circuit-breakers (RCCBs) are components for implementing protective measure "Automatic switch-off of power supply" as per VDE 0100 part 410 or corresponding international ...
Doepke Schaltgeräte GmbH
Primary current: 25 A
VAC: 230 V
Residual current circuit-breakers (RCCBs) are components for implementing protective measure "Automatic switch-off of power supply" as per VDE 0100 part 410 or corresponding international ...
Doepke Schaltgeräte GmbH
Primary current: 16 A
VAC: 250 V
VDC: 72 V
Thermal miniature circuit breaker, can be plugged into PT 10-FSI/C Push-in fuse terminal block. Type - Male Product type - Thermal device circuit breakers Number ...
VAC: 12 kV
CKWZ-12 outdoor AC high voltage vacuum circuit breaker is a new generation of outdoor vacuum circuit breaker self-developed on the basis of fully absorbing the advanced ...
Primary current: 1 A
VDC: 24 V
... 3 (emitted interference) CE: Acc. to 2014/30/EU Approvals UL 508, UL 2367, DNV GL Applications Electronic circuit breaker with thermomagnetic characteristic with alarm signal forwarded for ...
Primary current: 19 A - 1,250 A
VAC: 7.2 V - 84 V
... Generally, it is a satisfactory conductor to supply power and it promptly interrupts the current in case of an overload and short circuit faults to ensure the insulation. It is the most ideal, arc-extinguishing device. Product ...
Rating: 60 A
... Eaton’s BR two-pole ground fault circuit breaker boasts an improved series rating, offering additional combinations up to 60 A. And with higher interrupts and #3AWG lugs that reduce wiring costs, the ...
Primary current: 40, 200, 100 A
VAC: 15.5 kV - 27 kV
... weight of the device enables a quick and easy installation and fast commissioning. Self-powered from line current, the circuit breaker has the capability for multi-phase fault clearance for both transient ...
Primary current: 30 A - 5,000 A
VAC: 120 V - 600 V
... necessary overcurrent protection and service disconnecting means into the automatic transfer switch, a single installation can be made at the service entrance. This design eliminates the need for a separate ...
Primary current: 10 A - 63 A
VAC: 230 V
... short circuit, poor contact of connector, arc caused by house electrical apparatus fault).Then it triggers tripping unit to cut off the power supply to prevent electrical fire. AFDD is used together with leakage circuit ...
Primary current: 12 A - 30 A
VDC: max 12.0 V
Thermal circuit breaker, with controlled self-resetting mechanism, specially suited to installation in inaccessible locations. Under overload conditions the circuit breaker ...
E-T-A
Primary current: 4,000, 5,000 A
VAC: 550, 800, 252, 363 kV
... tightness technology, high design parameters, the whole structure of circuit breaker is compact, with stable and reliable performance and long endurance. 1 The circuit breaker ...
Henan ping high electric co., LTD.
Primary current: 630 A - 4,000 A
VAC: 10, 35 kV
Rating: 630 A
... Medium voltage vacuum circuit breaker Design Criteria IEC62271,GB1984 Conductor Type T2 Cu/Arcing chamber contact AgCr Frequency 50HZ Rated Voltage 10kV/35kV IP NA Product ...
Primary current: 630, 1,250 A
VAC: 12 kV
... outdoor H.V. permanent magnetic vacuum circuit breaker is used in tri-phase electric system of AC 50 Hz, rated voltage 12kV. It is suitable for breaking, closing load current, overload current and short-circuit ...
Wenzhou Vacem Technology Co., Ltd
VAC: 230, 400 V
Rating: 6 A - 63 A
... single pole 230V or two, three, four pole 400V voltage for overload and short-circuit protection as well as for un-frequent on-and-off switching electric equipment and lighting circuit ...
Yueqing Meba Electric Enterprises.
Primary current: 6,000 A
VAC: 230 V
Rating: 25 A
- Tripping curve: B, C B - The maximum current release breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect main power supply ...
Elmark
Primary current: 10 A
offers Photovoltaic Breaker (“PVB”) System as a remote controller for the PV field. The PVB system is composed of two parts: PVB transmission module (“PVB-Tx”) and PVB receive module (“PVB-Rx”). Using powerline communication ...
Primary current: 0 A - 63 A
VDC: 300 V - 1,200 V
DC circuit breaker for solar combiner box application. Up to 1200V 63A With TUV certificate
Zhejiang Benyi Electrical Co.,ltd.
Power Rider - Smart Automatic Circuit Breakers and PDU (available in 25A, 80A, 150A and 12 channel 25A), is based on semiconductors with fully automatic, highly reliable, ...
redler technologies
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining