|
|
Outline-flat filter exhaust
* Enclosure IP 43 to IP 54 (depending upon execution)
* Permission "Germanic Lloyd"
* Patented installation system "click and sits" for fast and screwless assembly
* Further technical details and special voltages on inquiry
|
|
|
The “FPF” series fan filters are widely recognised for their thin external profile, fashionable design, snap-mounting system and high performance. All models are Nema 12 and IP54 standard rated but, on request, alternatively available in Nema 3R and IP55 and also in EMC-shielded version.
|
|
-High through-flow air volume
-Functional design
-Time-saving installation
Filter fans are used to provide an optimum climate in enclosures.
The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air.
The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating.
The plastic usedfor the hood of this filter fan series is highly weather proof and UV light resistant.
Approvals: UL File Nr. E 234324
|
|
-High through-flow air volume
-Functional design
-Time-saving installation
Filter fans are used to provide an optimum climate in enclosures.
The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air.
The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating. The high-performance axial fan provides high air circulation.
The plastic usedfor the hood of this filter fan series is highly weather proof and UV light resistant.
Approvals: UL File Nr. E 234324
|
|
-Very low noise
-Minimal depth in enclosure
-Functional design
-Time-saving installation
Filter fans are used to provide an optimum climate in enclosures.
The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air.
The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating.
The plastic usedfor the hood of this filter fan series is highly weather proof and UV light resistant.
Approvals: UL File Nr. E 234324
|
|
The roof filter fan, with natural or forced ventilation, facilitates excellent internal air flow, removing dissipated heat from the cabinet.
The “TP” series in plastic construction, features reduced dimensions and a standard connection by terminal block.
|
|
-Very low noise
-Minimal depth in enclosure
-High through-flow air volume
-Uniform air circulation
-High reliability
-Time-saving installation
Roof filter fans and roof exit filters find use in enclosures, from which warm air has to be diverted due to increased heat development.
The ready-to-connect, low-noise roof filter fan, which houses four axial fans, is used to expel warm air from within the enclosure which has been generated by the stray power of the components.
The roof exit filter provides passive ventilation.
Approvals: UL File Nr. E 234324
|
|
Filter fans and EMC-compatible filter fans
Product group P3
These devices have "blowing" function only. Function "suction" is always to be ordered separately.
As a standard, all other devices are delivered having the function "blowing". Function "suction" by turning around the motor.
|
|
COMMON FEATURES
The units allow a simple and cost effective solution for
enclosure cooling.
Designed for easy clip-on mounting and made out of high resistance, self extinguishing ABS UL94VO grade (RAL7035) they cover an air flow rate range from 35 m3/hr to 1100 m3/hr.
They provide an IP54 protection degree.
All the fans are mounted on ball bearings with MTBF of 40000 hours.
|
|
Seifert has relied on consequent engineering for the four actual EMC filter fan models which have a lot to offer: suppression of up to 100dB thanks to a metallized EMC grid, a high protecting rating of IP55 & an assembly frame for easy mounting. A special feature of the largest model is the use of 4 separate economical fans for more air volume & less noise.
suppression of80...100 dB (up to 300 MHz)
air volume 21...300 m³/h EMV (Standart up to 550 m³/h)
complete sealing frame
reversable design cover
suitable outlet filter
quick press-in mounting
|
|
... see all the products in the category
Axial fans
|
Filter Collar Bonder™
Designed for attaching plastic circular collars to nonwoven filter bags
Suited for low-production assembly of bag filters for chemical and industrial liquid applications
Can assemble between 50 and 80 bags per hour*
Six-step welding process takes as little as 45 seconds to produce a reliable 360-degree bond
Speeds production by eliminating need for adhesives
Easy and quick tooling changes to accommodate collars from four to seven inches in diameter
Minimal training required
*For assembly of up to 200 bags per hour, Sonobnd's RingMaster™ is the machine of choice
|
|
SeamMaster™ High Profile Ultrasonic bonder
Special tooling offers unique advantages for assembling pleated filters
Rapid sealing and trimming of synthetic fabrics in one pass without glue, thread or other consumables
Ideal for hand-guided applications with tight tolerances
Porduction speeds up to four times faster than conventional sewing or heat sealing methods
Up to 10 times faster than adhesive machines
Variety of interchangeable pattern rollers for slitting, embossing, and stitching
Custom pattern wheels available
Meets tough industry regulations for barrier seams
Requires minimal training to operate
|
|
RingMaster
Attaches heavy-weight felted filter bags to rigid plastic collars
Strong, reliable bonds are completed in less than 10 seconds
Eliminates stitch holes that cause leaks, and thread that can get caught in pumps
|
|
Cleancare - MFQ370-22
Small – medium size ‘Q’ vac., 12L capacity, plus the HEPA microfilter module within the 2-speed steel ‘Q’ power head giving an exceptional 99.997% certified efficiency. Standard kit-A1. Microfilter machines are particularly suited to areas requiring very high levels of filtration, such as; computer rooms, hospital operating theatres & clinics, etc.
|
|
| ... products without technical information |
| |
Filter resistors and also damping resistors from JOVYATLAS are used to dampen capacitors and reactors, and in reactive-power compensation equipment. Filter resistors manufactured by JOVYATLAS have continuous loading capability and high-voltage strength.
We are happy at all times to prepare a technically expert, cost-optimised quotation to meet your requirements. Ask us – our skilled team of contacts is ready to assist.
|
|
The Harmonic Filter resistors are used to eliminate the dangerous distortions (harmonics) generated inside the network due to connection of more and more number of electronic power converters.
The main problems caused by harmonics, that are sinusoidal currents with different frequencies and amplitudes compared with the rated 50/60 Hz network currents, are :
- increment of losses on the line
- malfunctioning of the test equipments
- interferences with radio and phone systems
- resonances
- high currents at neutral point
These resistors , used together with reactors and capacitors, help to reduce and filter the harmonics.
|
|
B3000
filter regulator, stainless steel throughout
5 and 50 µm, G1/8 - G1
outlet 0 - 3 / 50 bar, max. 6000 l/min
|
|
Features
* High Flow Capacity
* Standard 5-micron filter
* No "yellow Metals" internal construction
* Epoxy coated finish
* Non-bleed design
* Integral Relief Valve
* Standard Gauge Port
* Filter Dripwell Drain Plug
* Standard Tapped Exhaust
* Soft Relief Seat
|
|
Actuating solenoid with built-in electronic timer. Two potentiometers
and two slide switches in the terminal box allow flexible adjustment
of pulse and interval duration. When the power is switched on, there
is a delay of about 1.5s before the valve is opened for a preset pulse
duration.
This is followed by a break (Pause). The durations involved are
generated by a microcontroller.
The power supply may be interrupted to carry out an operating test
without waiting for the break. The (N) terminal can be used to
operate the built-in solenoid independently of the cycle set, or to
operate an external "reference solenoid" in parallel with the internal
coil.
The 110/120V version's solenoid coil is operated by means of an
integral bridge rectifier. In this case external solenoids can only be
supplied with power using an additional rectifier.
|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
... see all the products in the category
Labware
|
AP&T manufactures and delivers complete production units for pressing filter housings in different designs.
The equipment is standardized and adapted to meet the customer's demands on finish and cost per detail.
|
|
BPVF1 is a test stand used for the check of the obstruction degree of oil filters.
Particularly it is used to check the efficiency of overhauled filters.
The test carry out an equal oil flow, at the same time, trough the new filter and the overhauled filter.
With a check of the pressure drop we can identify the acceptability or not of the filters
|
|
ALMATEC's high-pressure diaphragm pumps have been specially developed for charging filter presses with chemical wastes and special sludge.
With a driving pressure of max. 7 bar, the pumps of series AH build up a delivery pressure of 16 bar on account of the internal pressure boost. These genuine double-action pneumatic diaphragm pumps are available in three sizes with a maximum delivery volume of 4 m³/h (AH 15), 10 m³/h (AH 25) and 20 m³/h (AH 40).
All housing parts in contact with the product are made of PE UHMW. This polymer material is seven times more resistant to abrasion than PP. PE is also more resistant to wear than cast iron, aluminium and even steel.
|
|
| ... products without technical information |
| |
|
|
|
|
Hexagon Filter Cleaning System
General:
This ultrasonic cleaning system is designed to clean stainless steel filter elements. The system utilizes water and detergent in the ultrasonic cleaning tank. Parts are manually transported through the wash process.
System Layout:
The system is designed with a stainless steel exterior frame with all stainless steel tanks and a stainless steel countertop. The ultrasonic generators are mounted within the frame cabinet. The countertop is fitted with a drip ring around each tank opening to reduce run-off effects. System is built to provide a degree of protection against light overspray and splashing water.
Dimensions:
Overall console dimensions: approximately 22" x 28" with a counter top height of 42 3/4".
Equipped as follows:
Ultrasonic Cleaning Tank (each tank):
- Tank dimensions: Octagonal shaped, 10" across x 38" deep (14 gallons)
- Working dimensions: 10" across x 28" liquid depth
- Fabricated from 12 gauge, 316L stainless steel
- 1000 Watts, 40kHz transducers
- 1000 Watts Average power, 2,000 Watts peak power
- 1000 Watt Ultrasonic generator with Radio Frequency Interference (RFI) filter
- 1" drain with 1/4 turn brass ball valve
- 1000 Watts of thermostatically controlled heat
- Sound dampening insulation: typically reduces noise by 5 to 10 decibels
|
|
|
|