Fieldbus Network Link: Ethernet/PROFIBUS Gateway
The optimal solution for connection of fieldbus and Ethernet networks of up to 100 Mbit/s. |
|
The Westermo Fieldbus devices are industrial PROFIBUS DP modules. There are different types of slave modules and one Master module. PROFIBUS adapters that is able to transfer PROFIBUS DP I/O data via serial communication. I.e leased lines, dial up modems, Ethernet adapters, GSM modems or radio modems without any use of special drivers or special PLC bords. The FD-20, PROFIBUS DP Master module act the same way as the adapters on the serial side and act as a stand alone master on the PROFIBUS side. A combination with our Ethernet adapter gives the opportunity to connect PROFIBUS to Ethernet PROFIBUS DP converter to make a transparent connection for a different serial interfaces to a PROFIBUS DP network. |
|
FNL Proxy PN/PB
Integration of PROFIBUS DP systems into PROFINET IO networks
The 24 Volt hat rail module contains one PROFIBUS DP interface, four PROFINET IO RT interfaces as well as one RS232 service interface for commissioning and diagnostics.
The proxy integrates both existing and new PROFIBUS DP devices without any modification or adaptation into a PROFINET IO network. The PROFIBUS DP interface supports baud rates from 9.6 kbit/s to 12 Mbit/s.
The FNL Proxy PN/PB implements a plenty of PROFIBUS diagnostic functions as well as additional features, such as the configurable behaviour of the PROFIBUS DP Master in case of a break down of the PROFINET IO network or the detailed indication of error codes. Of course, it is also possible to combine several proxies.
COMSOFT‘s CONFIGURATOR II is available for compilation and download of the PROFIBUS configuration. The comfortable and full graphical tool compiles the PROFIBUS configuration via drag and drop mechanism. The integrated online mode allows direct commissioning and diagnostics of the connected PROFIBUS network via Ethernet.
The proxy implemented as PROFINET IO device and based on the Siemens ERTEC400 PROFINET IO controller supports PROFINET IO according to the current specification 2.0 and uses the modular mapping procedure. Input and output data as well as diagnostic data of the single DP Slaves are depicted through device modules (slots and sub-slots). Diagnostics are reported by a PROFINET IO alarm.
Furthermore SNMP diagnostics are included and the TFTP server based firmware update is supported. |
|
The Multi-port Industrial Serial Server SE5016 is a gateway between Ethernet (TCP/IP) and RS-232/RS-422/RS-485 communications. It allows almost any serial device to be connected to a new or existing Ethernet network.
By encapsulating serial data and transporting it over Ethernet, SE5016 offers full-duplex, bi-directional data transmission transparent between serial port and Ethernet network.
Flexible configuration options enable this unit to be setup over Ethernet by Telnet, Web browser, Serial Console, or other Windows utilities. Packed in a rugged metal housing with 19-inch rack-mount and 100~240VAC wide power input range, SE5016 is ideal for almost any industrial and manufacturing automation.
With its powerful computing power and Linux SDK, it could be a high performance programmable controller for time-critical, high-security, multi-function controller such as SCADA, telecommunication, transportation, banking, hospital, etc.
¡ CPU: RISC 32bits 266MHz
¡ Standard 19-inch rack-mountable
¡ Dual 10/100 Mbps Ethernet auto detection
¡ 8/16 Selectable RS-232 or RS-422/485 ports
¡ Surge protection for all serial signals (15 KV ESD)
¡ Supports TCP Server, TCP Client, UDP, and Virtual COM Modes
¡ Supports web pagee telnet consolesf LCM display with 4 keys configuration |
|
Serial Network Link: Ethernet/RS232/RS485 Gateway
The optimal solution for connection of serial and Ethernet networks of up to 100 Mbit/s. |
|
| PROFIBUS-DP-RS232/RS485 Gateway in a top hat rail housing with 24 V power supply for the connection to serial equipment to the PROFIBUS. XPS-E offers numerous possibilities of communication at a very attractive price. |
|
That serial Ethernet- converter echo left brings the data of serial interfaces on Ethernet and permits the main line train reef on devices with RS232/RS422/RS485/MPI/PPI/TTY (20mA).
* Visualization, factory data capture (BDE), Statisitk etc.
* Programming of the Simatic S7/S5/505 over LAN and WAN (by VCOM no Softnet necessarily)
* Remote maintenance of the S7/S5/505 over LAN and WAN
* Ethernet connection over PG-haven of the Simatic S5 (AG 90U, 95U, 100U, 115U, 135U, 150U, 155U)
* Ethernet connection over MPI/PPI haven of the Simatic S7 (S7-200, S7-300, S7-400)
* Active data exchange between controls without interference into the SPS program (echo active)
* Fetch/Write communication with S5-Steuerungen without handling components
* Web server functionality for the realization of small visualization projects: Visualization without PHP, ActiveX, Perl, applet etc. separate with pure HTML
* Optionally: Integrated switch to the fitting of further network participants
* Ethernet connection over CIM haven Honeywell/Klöckner Möller IPC 620 (ABC minutes) |
|
Connects your PROFIBUS to Ethernet
-Scalable from one PB channel to up to three PB channels per device
-Master or slave
-Ethernet 100BASE-TX / 10BASE-T, 100Mbits/s and 10 Mbits/s
-Application interface identical to Profibus interface cards
-PC drivers for Windows
-No fan
-OPC server available
-Suitable for use with DTM / FDT
|
|
Industrial Ethernet
In this area all Ethernet Gateways, Protocol converters and All-In-One bus nodes are filtered out and displayed. We are already offering solutions for 4 of the more then 20 Industrial Ethernet-versions. Others will be added.
Additionally you will find the Routers in this area, such as the Powerlink-Router. With these devices you connect Industrial Ethernet networks with the "standard" Ethernet. |
|
| Phoenix Contact has many years of experience in factory and process automation. Our innovative and practical Profibus interface components are used to increase installation flexibility and optimize costs in many industries including oil, gas, petrochemical, water and wastewater |
|
A new dimension to deltadue® series
232/485 converter - deltadue® Manager - Gateway
The Manager function uploads and stores the configuration of all deltadue® modules, to download it when the fault module will be changed.
The Gateway function performs the protocol convertion/optimisation from Modbus RTU-Profibus-DeviceNet to Modbus RTU.
Two serial SLAVE ports allow to use simultaneously 2 MASTERS devices with the same modules group.
|
|
UP for an industrial strength painkiller?
Enabling communication from factory floor devices to PLC controllers just got a whole lot easier. The DeviceMaster UP industrial Ethernet gateway offers a flashable solution that configures in minutes via the web, allowing you to support the major industrial Ethernet PLC networks – EtherNet/IP, PROFINET, or Modbus/TCP – on a single platform.
Whichever protocol you need, the DeviceMaster UP provides an RS-232/422/485 software-selectable connection to an industrial Ethernet network.
By accommodating multiple protocols, the DeviceMaster UP provides an adaptable and flexible platform device integrators and distributors need to thrive in rapidly changing markets. It's the pain-free Industrial Ethernet solution that simplifies supply chain management and reduces expenses for you and your customers.
It's power over protocol.
DeviceMaster UP Highlights
DualConnectPlus™ Technology – simultaneously connect both serial and Ethernet devices to PLCs and/or applications. String, RFID, and barcode data filtering eliminates redundant data while extracting the RFID and barcode parameters.
Provide PLC connectivity to standard serial devices with flashable protocol support for EtherNet/IP, PROFINET, Modbus/TCP, and TCP/IP
Compact and hardened form-factor — wide -37° to 74°C industrial temperature range
Variable power input eliminates need for power converters
PortVision® enables user to view status, update firmware and resolve issues remotely.
RoHS Directive 2002/95/EC compliant |
|
Director
The Director (DS4) is an expandable Industrial Network Gateway built around Eurotech Ltd's APEX software core enabling both operational and financial data to be acquired, networked, transformed and utilised efficiently taking full advantage of the TCP/IP technologies and communication networks.
Features
Architecture Single boards
Processor/clock speed Intel 386EX CPU @ 25MHz
Memory 1MB SRAM with battery back-up and 1MB Flash
Operating system APEX
Configuration ACE
Size 4 1/8" x 6 1/2" x 4 3/8"
Mounting Panel mount
Watchdog Hardware with start-up or software trigger
Serial ports 3 x RS232 and 1 x RS232/RS485 selectable
Protocol Multiple protocol support
Power requirements 18 - 36V DC input range
Power consumption 3W (maximum, with standard board set only)
Operating Temperature -40 to 70°C at 25MHz
Humidity 0 to 95% relative, non condensing
Diagnostics Serial MMI or Telnet
Networking TCP/IP serially or RJ-45 10BaseT Ethernet
Calendar/Clock RTC with battery back-up
Input/output 3 available slots for PC/104 expansion modules
|
|
RFID-EC-IC
The RFID Edge Controller Industrial Compact Enclosure (RFID-EC-IC) is designed to be installed in harsh warehouse and factory floor locations where space is at a premium and co-location with remote RFID infrastructure is required. Eurotech Ltd's RFID Edge Controller (RFID-EC) works in conjunction with IBM's WebSphere RFID Premises Server to provide a complete end-to-end solution. The basic premise of the RFID-EC is to provide the hardware and software interfaces required by many of the individual devices (sensors, discrete I/O, PLC's, etc) within a customer's facility.
Features
Fitted with Eurotech Ltd's VIPER SBC
Input voltage range 10 - 36V DC (10 - 25V AC)
Battery backed operation for over 2 hours of normal operation
Operating temperature: 0°C to 55°C
Weight: 1.7Kg including VIPER, VIPER-UPS
Enclosure dimensions: 200mm x 210mm x 105.2mm including mounting feet
RJ45 Ethernet connector with activity and link LEDs
4 x RS232 on standard DB9
1 x RS485/422 on DB9
2 x USB host ports
CompactFlash (CF ) Socket
|
|
Controllers / Gateways
AS-i controllers, gateways, masters and repeaters are elementary components of AS-i networks. These components are most of the time placed in the control cabinet and ensure data communication, extension and power supply of the connected slaves, sensors and actuators. |
|
| AS-Interface networks up to 62 field devices onto a single pair of wires that delivers both signal and power. Actuator Sensor Interface, or AS-Interface, was developed by a group of sensor manufacturers and introduced into the market in 1994. Since that time, it has become the de facto standard for discrete sensors in process industries throughout the world. AS-Interface may be used in hazardous process environments using explosion proof, tray cable, nonincendive and for nonincendive wiring protection concepts. |
|
DeviceMaster UP Industrial Ethernet Gateways
Enabling communication from factory floor devices to PLC controllers just got a whole lot easier. The DeviceMaster UP offers a flashable solution that configures in minutes via the web, allowing you to support the major industrial Ethernet PLC networks – EtherNet/IP, PROFINET, or Modbus/TCP – on a single platform.
Whichever protocol you need, the DeviceMaster UP provides an RS-232/422/485 software-selectable connection to an industrial Ethernet network.
By accommodating multiple protocols, the DeviceMaster UP provides an adaptable and flexible platform device integrators and distributors need to thrive in rapidly changing markets. It's the pain-free Industrial Ethernet solution that simplifies supply chain management and reduces expenses for you and your customers.
It's power over protocol.
Highlights
DualConnectPlus™ Technology – simultaneously connect both serial and Ethernet devices to PLCs and/or applications. String, RFID, and barcode data filtering eliminates redundant data while extracting the RFID and barcode parameters.
Provide PLC connectivity to standard serial devices with flashable protocol support for EtherNet/IP, PROFINET, Modbus/TCP, and TCP/IP
Compact and hardened form-factor — wide -37° to 74°C industrial temperature range
Variable power input eliminates need for power converters
PortVision® enables user to view status, update firmware and resolve issues remotely.
RoHS Directive 2002/95/EC |
|
UP for an industrial strength painkiller?
Enabling communication from factory floor devices to PLC controllers just got a whole lot easier. The DeviceMaster UP offers a flashable solution that configures in minutes via the web, allowing you to support the major industrial Ethernet PLC networks – EtherNet/IP, PROFINET, or Modbus/TCP – on a single platform.
Whichever protocol you need, the DeviceMaster UP provides an RS-232/422/485 software-selectable connection to an industrial Ethernet network.
By accommodating multiple protocols, the DeviceMaster UP provides an adaptable and flexible platform device integrators and distributors need to thrive in rapidly changing markets. It's the pain-free Industrial Ethernet solution that simplifies supply chain management and reduces expenses for you and your customers.
It's power over protocol.
Highlights
DualConnectPlus™ Technology – simultaneously connect both serial and Ethernet devices to PLCs and/or applications. String, RFID, and barcode data filtering eliminates redundant data while extracting the RFID and barcode parameters.
Provide PLC connectivity to standard serial devices with flashable protocol support for EtherNet/IP, PROFINET, Modbus/TCP, and TCP/IP
Compact and hardened form-factor — wide -37° to 74°C industrial temperature range
Variable power input eliminates need for power converters
PortVision® enables user to view status, update firmware and resolve issues remotely.
RoHS Directive 2002/95/EC compliant |
|
Ethernet Gateway - echochange connects Ethernet worlds
More and more Ethernet is being used in industry. Serveral protocols based on Ethernet are available: ISO (H1), ISO on TCP (RFC1006) or EtherNet/IP. Although these protocols are similar, communication between the corresponding networks is not that simple.
Echochange provides the solution:
This produces „relationships“ between plants that were previously incompatible. The gateway may be configured locally or remotely and supports up to 30 active connections. The configuration software provides comprehensive diagnosis functions.
Special Features:
Connects different controller worlds
▪ Siemens (S7, S5)
▪ Rockwell Automation
(Allen-Bradley)
▪ Schneider Electric (Modicon)
Separated Ethernet networks
are connected via specific
parameterized connections
Connection of TCP/IP computers
with ISO (H1) networks
Remote maintenance of PLCs in an ISO (H1) network via TCP/IP
Gateway between separated networks (protocols run at the same media)
Converter in a heterogeneous network (protocols run at the same media)
Easy configuration: Online via IP or ISO (H1), serial or offline for later transfer |
|
Direct communication with S5 and much more!
The Data Station Plus is a multiple protocol converter, a system data logger, and a web interface for industrial applications.
With two RS-232 and one RS-422/485 communications ports, as well as a 10 Base-T/100 Base-TX Ethernet port, the Data Station can connect to various devices simultaneously. With downloadable communications drivers, the Data Station can communicate to virtually any serial or Ethernet device in its own native language, and transfer that data to and from any other connected device. Integrating devices with mismatched protocols can now be done with the click of a mouse!
The data logging facility allows variables to be collected and stored along with a time and date stamp for later review of the process. Files are stored on CompactFlash in IT ready format, allowing programs such as Microsoft Excel to access them.
The "virtual HMI" facility provides a means to view and control a process from any networked PC, using only a standard web browser. The new VGA resolution provides SCADA like display capability at no extra cost. The port sharing facility allows serially connected devices to be reprogrammed remotely.
SOME FEATURES:
- Protocol Conversion Feature Converts Numerous Protocols Simultaneously
- CompactFlash ® Slot Allows Process Data to be Logged Directly to CSV Files (DSPSX & DSPGT)
- Virtual HMI Offers Built-in PC-based SCADA Functionality (DSPSX & DSPGT)
- Webserver Provides Worldwide Access To Data Logs And Virtual HMI (DSPSX & DSPGT)
- Extensive Built-in Driver List Allows Easy Data Mapping to PLCs, PCs, and SCADA Systems
- Alarm Notifications can be sent via Email or Text Messages (DSPSX & DSPGT) |
|
The BradCommunications applicom® PROFINET IO Proxy provides real time connectivity between a PROFINET I/O controller and Ethernet/PROFIBUS/Serial devices
Easy to use: no programming, just configuring
Protocols available: Ethernet TCP/IP (Client/Server); Siemens Industrial Ethernet (S5/S7/TI); Altus - Alnet II ; Allen Bradley EtherNet/IP (PCCC); Schneider UNI-TE; Open Modbus; Mitsubishi Melsec A & Q; Omron FINS; GE Fanuc SRTP ; Serial; Modbus RTU (Master/Slave) / Modbus ASCII (Master/Slave); Profibus; PROFIBUS DP-V0 Master Class1 & Class2; PROFIBUS DP-V0 Slave; PROFIBUS S7/MPI Client (S7-300/400); PROFIBUS S5 FDL Client. |
|
Features:
- Version 3.0 Master, compatible with
all 2.0-3.0 slaves and 7.3 profile
analog modules
- Duplicate address detection
- AS-Interface peripheral fault
diagnositcs
- Serial Diagnostics Port: see 462008
for cable and software
- ETL approved Class I Division 2 |
|
Safety interface, galvanic isolator and field gateway
The multi-channel gateway integrates Enraf’s field equipment into tank terminal information systems.
The SmartLink provides a physical layer conversion from serial RS232C/RS485 GPU communication to Bi-Phase Mark GPU field bus.With the modular design of the SmartLink this gateway becomes scalable from small towards large tank terminal installations.
The SmartLink can be expanded from one to three field busses of the worlds standard field communication in tank gauging, Enraf’s GPU Bi-Phase Mark.
The GPU/BPM field bus guarantees a stable, long distance, galvanic isolated digital communication link for integration of Enraf field equipment. Avoiding grounding issues and protecting against damages resulting from lightning strikes on the field communication lines. The SmartLink is fully transparent to the GPU communication.
|
|
The Latest in the OCS Range Integrates Screen, PLC, Network and I/O "All in One" Product.
The OCS NX has the following features:-
- 128x64 or 240x128 Pixel Backlit LCD Screen.
- Embedded Ethernet.
- Optional Fieldbuses.
- Compact Flash.
- Smartstack Interface.
- 2 Serial Ports.
- USB Programming Port.
- Fibre Optic Interface.
- Integrated Fast Counter I/O.
- Membrane with Function Keys.
- Optional Touchscreen.
- Optional Integrated Base I/O.
Instead of using Separate components (PLC, HMI , Network and I/O) to form a solution , Horner has integrated this functionality into a single product – the Operator Control Station (OCS).
The OCS provides a complete solution and is easily programmed by a SINGLE software package called CSCAPE which allows screens to be easily embedded in the Logic Programme whether it is LD, IL, ST , SFC or FBD it is incredibily easy to use.
Contact us for more Pre Release Information
|
|
The RTU870 Series encompasses a wide range of compact RTUs with data logging capability and with on board I/Os expandable from 8DI/DO to several hundred I/Os.
The units are DIN-rail mountable and have a number of DC or AC power options, including battery charger to provide battery back-up when mains supply fails.
A full package of configuration and driver tools are provided, which support programming of simple control sequences and dial-up settings for modems.
The RTU870 supports EN/IEC60870-5-101 utility protocol offering simple configuration of application data |
|
Gateways
The intelligent Gateway for the connection of industrial networks - UNIGATE FB
Connecting incompatible networks
In the field of automatic control many different Fieldbuses and Industrial Ethernet became established worldwide. Again and again the task of interconnecting these incompatible networks comes up. The UNIGATE® FB-series was created exactly for that task. The series contains Fieldbus-Slave as well as Industrial Ethernet versions.The UNIGATE® FB is designed as DIN-rail module and contains the selected Fieldbuses or Ethernet in the mechanical variant carried out in the respective standard. Internally the product is realized by using two UNIGATE® IC-modules that are mounted on a carrier motherboard. By this modular structure all Fieldbus- and Ethernet-versions can be supplied, provided that the respective
IC-modules are available. The number of available versions is growing steadily by the continuous development of new IC-modules e. g. in the Industrial Ethernet field.
In case of the series UNIGATE® FB, the data exchange between the Fieldbuses or Ethernet is realized through a Script. With the free PC-tool "Protocol Developer" this Script is generated and optimally adjusted to the final product and the requirements. |
|
PORTMASTER V3 (604 700)
• Easy configuration over USB port.
• 1 Ethernet, 1 USB and 4 RS232/RS485 ports
• Modbus RTU over Ethernet and USB
• Protocol conversion between Modbus TCP ve Modbus RTU
• 4 Master and 6 Slave port support
• Unlimited port support with cascading connection.
• Automatic cyclic polling of the field devices on Master ports.
• Automatic processing between Master and Slave ports
• High priority force instructions on Master ports
• Combines many field devices and converts them into a single MODBUS slave device
• Dynamic Slave defining
• Fast reaction time
• Low power consumption
• DIN-Rail mountable compact design.
The PortMaster V3 is MODBUS communication unit, which enables multi-port serial communication, protocol conversion in industrial applications.
The PortMaster comprises four RS232/RS485 ports, one Ethernet and one USB port. Each serial port is independently programmable as Modbus master or slave ports and Ethernet and USB ports can be defined as slave ports. Also all ports can be used as configuration port.
Each port defined as a MODBUS slave can be connected to a PLC or RTU port defined as a MODBUS master. The ports defined as masters are connected to field devices and provide automatic cyclic polling of the field devices.
Master ports can access more than one slave port with Address Remapping function.
The PortMaster is a cascadable unit, which allows having more than four ports when required.
Configuration of the PortMaster can be done with PC connected over USB port with PortConfig, a Windows based software. |
|
Modbus is one of the most popular automation protocols in the world. Modbus protocol supports traditional RS-232/422/485 devices and newly developed Ethernet devices. Many industrail devices, such as PLCs, DCSs, HMIs, instruments, and meters, use Modbus as their communication standard. However, the Modbus protocol running over serial and Ethernet are so different that a communication gateway is needed as a bridge for integration. NPort 6110 supports one Ethernet and one software selectable RS-232/422/485 port that can connect with all kinds of Modbus devices. By translating Modbus/TCP (Ethernet) and Modbus/ASCII/RTU (Serial) protocols, a PLC with Ethernet can use the RS-232/422/485 interface to seamlessly communicate with instruments.
Features
· Modbus serial and Ethernet device integration
· Supports Modbus/TCP Master device to
Modbus/ASCII/RTU slave devices (up to 31)
· Supports Modbus/ASCII/RTU master device to
Modbus/TCP slave devices (up to 4)
· Easy-to-use Windows utility for configuration over
Ethernet
· 10/100M fast Ethernet with automatic IP setting (DHCP)
· One software selectable RS-232/422/485 interface
· High speed serial up to 230.4 Kbps |
|
| A unique modular approach to Fieldbus physical layer components provides infrastructure connection between the process Fieldbus controller and field devices. |
|
| ... products without technical information |
| |
|