Full inline quality control for soft drink production. Know in less than one minute the dissolved carbon dioxide, oxygen, and temperature in the product. Offers real-time analysis. Audible and visual alarms. Internal components are sanitized automatically during normal CIP operation. Up to 1,000 product specifications can be stored in the software.
-Confirm carbon dioxide levels within one minute of initial startup or changeover
-Confirm Brix levels within three minutes
-Reduce product and package waste by not filling packages with product out of specifications
|
|
The Vaisala CARBOCAP® Hand-held Carbon Dioxide Meter GM70 is available with a sampling pump. The GM70 with the pump-aspiration option is ideal for validating the calibration of incubators and environmental chambers.
To prevent condensation from occurring when drawing a gas sample from an environment with high humidity and temperatures into ambient air, an option called Nafionä tubing is available. The tubing prevents condensation in the gas sample by selectively removing the water vapor without affecting the level of CO2.
The GM70 incorporates the Vaisala CARBOCAP® Sensor, which is a silicon-based NDIR sensor that provides excellent reliability and long-term stability. Features include ten measurement ranges between 0…20% CO2 and a two year recommended calibration interval.
The GM70 has a multilingual user interface and a graphical LCD display. Data can be logged up to 30 days. The optional Windows® software provides an easy-to-use interface to a PC. Probes for measuring relative humidity, temperature and dewpoint temperature can also be connected to the GM70. A carrying case incorporates all the equipment and keeps the setup ready for immediate measurement.
|
|
| The Series 9500 Oxygen and Carbon Dioxide Monitor is designed to provide continuous, unattended monitoring of both oxygen and carbon dioxide. |
|
Series 200ACE Acetaldehyde Analyzer
Meets ISBT Method 11 criteria for selective measurement of acetaldehyde in CO2
- Rugged, low cost, low maintenance, turn-key system
- Capable of PC-based control and data logging
- Batch or continuous stream monitoring
- Detector: Flame Ionization Detector (FID)
- Automatic, hands-free calibration, flow setting and analysis
- Detection limits for acetaldehyde of < 30 part-per-billion (ppb)
- Instrument operating temperature: ambient
- Detector temperature: factory set; adjustable
- Oven temperature regulation: factory set with software controlled conditioning
- Tested against virtually all of the potential alcohol and oxygenate impurities that could be present and determined to be interference-free
- Acetaldehyde is captured by the software system, with results displayed digitally on the instrument's front panel
- On-board software package contained in the Series 200ACE allows complete unattended operation
- Installation: bench or 19" rack
- Power: 115-230 V, 50-60 Hz |
|
Series 200AHC Aromatic Hydrocarbon Analyzer
Specific detection of benzene within beverage-grade carbon dioxide.
Trace aromatic impurity monitoring is of critical importance to carbon dioxide manufacturers and the carbonated beverage industry. The Series 200 AHC meets all ISBT Method 12.0 criteria for selective measurement of benzene in carbon dioxide. Continuous stream or batch sampling operations are readily performed.
The Series 200 AHC is specifically designed as a rugged, low cost, low maintenance, simple to operate, turn-key system. No cylinder support gases are needed. Calibration and sample introduction are totally automated. A newly designed photo-ionization detector (PID) and proprietary technology are used for the specific measurement of benzene without interference from other potential impurities in beverage-grade carbon dioxide. Detector response is linear over three orders of magnitude. The detectable limit for benzene is 3 ppb, which is far below the ISBT guideline limit of 20 ppb. GOW-MAC’s Series 200 AHC system is also capable of PC-based control and data logging. Full documentation is provided, along with optional customer training and support services.
|
|
Series 200BTEX Gas Analyzer
Meets all ISBT Method 12 criteria for selective measurement of BTEX (benzene, toluene, ethyl benzene, o-xylene, m-xylene, and p-xylene) in CO2
- Rugged, low cost, low maintenance, turn-key system
- Features: Auto-Calibration, Auto-Calibration Validation, Process/Manual mode, As Found/As Left function, Sample stream selection, and six 4-20 mA outputs
- Capable of PC-based control and data logging
- Batch or continuous stream monitoring
- Detector: Photo Ionization Detector (PID)
- Automatic, hands-free calibration, flow setting and analysis
- Detection limits for benzene of < 5 ppb
- Instrument operating temperature: ambient
- Detector temperature: factory set; adjustable
- Oven temperature: factory set with software controlled conditioning
- Tested against virtually all of the potential alcohol and oxygenate impurities that could be present and determined to be interference-free
- Benzene is captured by the software system, with results displayed digitally on the instrument's front panel
- On-board software package contained in the Series 200AHC allows complete unattended operation
- Installation: bench or 19" rack
- Power: 115-230 V, 50-60 Hz |
|
| ... products without technical information |
| |
Engineered to fit within a variety of bioreactors, the YSI 8500 delivers precise, real-time data that increases your understanding of critical fermentation and cell culture processes.
This data can help you gain insight into cell metabolism and other changes within your bioreactor.
The YSI 8500 allows you to monitor dissolved CO2 via real-time display of digital data or you can use the instrument's plot function to see the data graphically.
You may also upload data to your computer or incorporate the output signal into your control processes. Data points can be logged as frequently as every 15 seconds, but can be set at longer intervals to reflect the length of your run.
|
|
|
|