Centrifugal blowers
Flow: 0 m³/h - 2,040 m³/h
Operating pressure: 250 mbar
Nominal power: 5.5 kW - 18.5 kW
A belt-driven, compact blower incorporating backward curved turbine bladed impellers. Powerful and quiet, ACI’s EP10A compact blowers are available with motors up to 18.5kW in standard metric or NEMA ...
Flow: 9.2 m³/min
Operating pressure: 40,000 Pa
Sound level: 65 dB
RAETTS miniature air bearing blowers as big as a suitcase, industry debut! Miniature air bearing blower is another masterpiece after the universal and portable blowers, as soon as it ...
RAETTS
Flow: 1 m³/min - 24 m³/min
Operating pressure: 9,000 Pa - 25,000 Pa
Nominal power: 0.2 kW - 19 kW
Low noise and vibration Dynamic balancing minimizes vibration. Dust-proofed shaft seal Protects bearing from contaminated air stream and possible foreign particle damage. High reliability Directly connected ...
Chuan-Fan Electric
Series L Roots Blower Applications of Series M Roots BlowerSeries L Roots Blower (also called Positive Displacement Blower - PD Blower, or Rotary Blower) ...
Greentech International (Zhangqiu) Co., Ltd.
Flow: 350 m³/h - 1,400 m³/h
Operating pressure: 80 Pa - 1,400 Pa
Eurovac MB series blowers are designed for transmitting clean air, e.g. for machinery cooling. Blowers are made out of epoxy coated steel with forward curved blade radial impeller. Maximum ...
Eurovac / suomen imurikeskus Oy
Flow: 30 m³/h - 10,000 m³/h
Operating pressure: 6,000 Pa - 65,000 Pa
Nominal power: 0.12 kW - 18.5 kW
Vortex gas pump The ring blower (channel blower, gas pump, air blower) made by aluminum alloy, that make it small body and small weight. The products are widely used for clothes, printing, ...
Hengsu Holdings Co,.Ltd.
Flow: 110 m³/h - 2,330 m³/h
Operating pressure: 210 mbar - 670 mbar
Nominal power: 0.85 kW - 25 kW
... stage side channel blower LD 250 H43 RW9 Quiet Equipped with low-noise, high-efficiency IP54 induction motor and specially designed mufflers, all blower series feature quiet operation. Mechanism ...
Manvac Technik ltd
Flow: 40 m³/h - 2,640 m³/h
Nominal power: 0.2 kW - 20 kW
Exhaust-blower fans with side ducts The operation of exhaust-blower fans with a side duct is based on the principle of downflow by means of vortexes created by the centrifugal thrust ...
When the impeller rotates, the air between the blades is radially and circumferentially accelerated and forced into the side channel where it is compressed and forced backwards towards the impeller blades where it is again radially and ...
... of four compact turbo blowers Models: 3.5kW, 4kW, 5.5kW and 7.5kW - Performance: Flow rates up to 12.5m³/min (750m3/hr), operating at speeds of 80,000 RPM. - Energy Efficiency: Over 50% energy savings versus traditional ...
Smart Aeration Solutions
Flow: 0 m³/h - 8,000 m³/h
Operating pressure: 0 Pa - 3,950 Pa
Nominal power: 0.55 kW - 7.5 kW
... directed to the required area unfiltered via a pipe system. The RG series devices are suitable for granulates or as a feed blower for ventilation of rooms, tanks and shafts.
Flow: 0.06, 0.71, 0.88, 0.95 m³/min
Operating pressure: 0 Pa - 0 Pa
Nominal power: 6 W - 13,920 W
Frame Black PBT UL94-V0 glass filled Impeller Black PBT UL94-V0 glass filled Lead wires UL 1007 AWG 24 Bearing Ball bearings Hypro Bearings Insulation resistance 10 MOhm lead wire/frame (DC 500 V) Dielectric strength 5 mA ...
Operating pressure: 80 mbar - 435 mbar
Nominal power: 0.2 kW - 22 kW
Dutair blowers are used worldwide for their highly reliable operation in the usual fixed frequencies of 50 and 60 Hz. The technical specifications comprise a range from 30 to 80 Hz in 10 Hz steps which makes Dutair blowers ...
Sjerp & Jongeneel
Flow: 1,000 ft³/min - 14,000 ft³/min
Sound level: 80 dB - 82 dB
Weight: 690 lb - 1,193 lb
... With the absence of pulleys, fan bearings and belts, The high efficiency blower design offer competitive manufacturing costs and lower power consumption. The optional quick access door and the absence ...
Flow: 42,475.2 m³/h
Operating pressure: 0 psi - 20 psi
... multistage fabricated centrifugal blowers are crucial pieces of equipment that organizations count on to perform well from the moment they’re installed. When you choose Howden over other multistage ...
Flow: 850 m³/h - 38,000 m³/h
Nominal power: 0.09 kW - 7.5 kW
Specification:2.5#~8# Power:0.09~7.5KW Flow rate:850~38000m³/h
Zhongshan Yongning Ventilation System Manufacturing Co., Ltd.
Flow: 610 m³/h
Operating pressure: 666 Pa
Nominal power: 175 W
... EC fans. EC fan with DC and AC input voltage. Certificate: CE MOQ: 1~200 pcs based on EXF price; 200 pcs above based on FOB price; Supply Ability: 80000 pcs per year Payment terms: T/T; L/C EC blowers ...
PBM Motor and Fan (Suzhou) Co.,Ltd
Nominal power: 250 W - 750 W
Features PFHT 250 Heating capacity 250 - 750W Power Supply 230V 50/60 Hz
Flow: 350 l/min - 407 l/min
Operating pressure: 4,200 Pa - 5,019 Pa
Nominal power: 24 W - 33.1 W
Product Parameter: IN freeblowing: 1’250/1’600mA n freeblowing: 31’200/34’500rpm V freeblowing: 355/407 l/min P static: 4’200/5’019Pa PN work. point: 24.0/33.1W VCC Nominal Voltage:24V Features: * Dimensions: 61.4 x 61.4 x 50.8 ...
Boreasa Technologies Co., Ltd
Flow: 760 ft³/min
Operating pressure: 160 mbar
Nominal power: 3.7 kW - 7.5 kW
JetAir Technologies’ JET-1™ Blower is the most efficient blower in its class engineered for moderate flow and moderate pressure applications from 5HP[3,7kW] to 10HP[7,5kW]. The JET-1™’s Direct Drive design ...
JetAir Technologies
... product highlights 20% more efficient horse power. A Paxton XT 500 blower is an example of a blower that has 20% more flor (CFM) at a same pressure compared to a regular 5 Hp centrifugal ...
Paxton Products
Flow: 1,100 m³/h
Operating pressure: 0 Pa - 65,000 Pa
... Treatments and solutions with Biogas. The blower or side channel extractor increases the pressure of the gas sucked in by creating, in the peripheral toroidal chamber, a series of whirlwinds caused by the centrifugal ...
Flow: 960 m³/h - 1,560 m³/h
Operating pressure: 2 bar
Nominal power: 21 kW - 39 kW
... and between each rotor and the blower housing. Since the tolerances are very tight it is an absolute requirement to prevent the intrusion of an external solid element into the pumping chamber. Therefore the AIDA blower ...
Flow: 20 m³/h - 2,500 m³/h
Operating pressure: 0 mbar - 1,000 mbar
Blowers can operate either as exhausters or compressors and are designed for continuous operation. Full die-cast aluminium construction grants the maximum sturdiness. They can be used both for industrial and standard ...
EMMECOM SRL
Flow: 190, 148 m³/h
Operating pressure: 190 mbar
Nominal power: 1.3, 1.1 kW
Blower│Industrial blower│UC-RB075/1 Feature: Low noise level, High air volume,Low vibration & Contamination free Application: Dust collecting plant, Aerator tank, Air Knives,Sewage treatment, Aquaculture, ...
UNi-CROWN CO., LTD.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining