Air flow: 2,400 m³/h
... UltraFlex, Flex, T-Flex extraction arms FAN-28 is a wall-mounted extraction fan FAN-28 is especially designed to fit the large diameter (200mm) arms in our extraction arm program. ...
PLYMOVENT
Air flow: 3,000 m³/h
... with the extention crane and stationary filter The FAN 42 is an extraction fan used for small welding fume extraction systems The FAN 42 is a wall-mounted extraction fan ...
PLYMOVENT
Air flow: 0 m³/h - 3,700 m³/h
... direct-mount fan for Plymovent's systems The FUA series ventilation fans are designed for direct mounting on our metal- and hose tube extraction arms and filters or for use as central fans. ...
PLYMOVENT
Air flow: 500 m³/h - 1,870 m³/h
Noise level: 52 dB - 63 dB
... The radial fans on KryosROOF provide high flow rates and heads to ensure the correct airflow within the cabinet. In addition, there is a high efficiency version with EC fans and an ...
BAF - Fans For Extraction Arm Bomaksan branded BAF model fans are specially designed to work with extraction arms. Bomaksan BAF series fans are preferred thanks to their high suction ...
Air flow: 1,250 m³/h
Practical benefits: Professional quality "made in Germany" - Original Trotec fabrication Extremely powerful radial blower- max. 1.050 Pa - optimal for ventilation over long hose distance Adjustable air ...
Trotec GmbH
Air flow: 400 m³/h
... turbo fans are purposed to cater to the challenges that are daily put forward on them, but also proves that they are built for long service life. The TFV 10 S can perform at several angles such as 0°, 45°, 90°, which ...
Trotec GmbH
Air flow: 10,000 m³/h
... 600 Ex the ideal conveying fan for ventilation in ex-proof zones of class 2, e.g. for tank cleaning, in docks, refineries, shafts or silos. Even with long hose distances of 50 metres with multiple arcs this powerful ...
Trotec GmbH
Designed for manual parcel loading and unloading CoolMan 2800 Trailer Fan swivels on unique bracketing to service two loading dock openings Easy vertical or horizontal adjustment using T-style handle for full access ...
Air flow: 0 m³/h - 1,000 m³/h
Fans are used in combination with duct on KEMPER welding smoke exhaust arms, telescopic arms and suction hoses. They are used for venting or ventilation wherever filtering the air is not important. Due to the cast silumin ...
KEMPER
Air flow: 0 m³/h - 3,000 m³/h
Fans are used in combination with duct on KEMPER welding smoke exhaust arms, telescopic arms and suction hoses. They are used for venting or ventilation wherever filtering the air is not important. Due to the cast silumin ...
KEMPER
Air flow: 2,000 m³/h - 4,000 m³/h
Central fans are the ideal solution when large amounts of air need to be moved. They are put to use in combination with duct on welding fume extraction tables, hoods and arms. Fans are used everywhere ...
KEMPER
Air flow: 15,000 m³/h
Rotational speed: 2,755 rpm - 2,950 rpm
Noise level: 70 dB - 94 dB
FUMEX FBE – an energy-efficient fan designed for industrial environments which can be installed both indoors and outdoors. For expelling non-explosive gases, fumes and lighter particles with an airflow of up to 15000 ...
Fumex
Air flow: 6,600 m³/h
Rotational speed: 2,890 rpm - 2,940 rpm
FUMEX FTE is a range of radial fans for use at high concentrations of dust-laden air. Fan housings and impellers are made from heavy-duty steel sheet for industrial use. The welded impeller ...
Fumex
Air flow: 600 m³/h
Rotational speed: 2,800 rpm
Centrifugal fan for smaller applications FUMEX C 600 – a compact and sturdy fan which can be installed both indoors and outdoors, designed for industrial environments. The forward-curved ...
Fumex
NESTRO fans are the heart of every extraction system - proven, efficient and durable. If the fan is installed on the raw gas side, it blows into the filter system and is referred to as an overpressure ...
NESTRO Lufttechnik GmbH
NESTRO transport fans transport the material to be filtered, e.g. in long pipelines or in the event of high volume flow requirements. They support/relieve the burden on the extraction fans.
NESTRO Lufttechnik GmbH
NESTRO fans are the heart of every extraction system - proven, efficient and durable. If the fan is installed on the clean gas side, it sucks air through the filter system and is referred to as a vacuum ...
NESTRO Lufttechnik GmbH
Air flow: 200 m³/h - 750 m³/h
Diameter: 108 mm - 200 mm
ECOFIT Single inlet centrifugal fans AC single phase motor Forward impeller galvanized steel or plastic, Impeller diameter of 108 up to 200mm, AC single phase capacitor external rotor motor 230V50/60Hz ...
ROSENBERG VENDÔME
Air flow: 400 m³/h - 1,100 m³/h
Diameter: 120 mm - 180 mm
ECOFIT Double inlet centrifugal fans AC single phase motor Forward impeller galvanized steel, Impeller diameter of 120 up to 180mm, AC single phase capacitor external rotor motor 230V50/60Hz and ...
ROSENBERG VENDÔME
Air flow: 315 m³/h - 1,900 m³/h
Diameter: 133 mm - 315 mm
Backward ECOFIT centrifugal fans AC single phase motor Backward impeller plastic or galvanized steel, Impeller diameter of 133 up to 315mm, AC single phase capacitor external rotor motor 230V50/60Hz ...
ROSENBERG VENDÔME
Air flow: 10,102 m³/h - 77,340 m³/h
Diameter: 26 in - 69 in
Noise level: 62 dB - 74 dB
Exhaust Fans with Steel blades & Galvanized Housing Move and refresh the stagnant air in your tunnel, greenhouse or commercial warehouse to create a healthy and more productive environment. Our exhaust fans ...
Air flow: 21,356 m³/h - 35,850 m³/h
Diameter: 51 in
Noise level: 75, 72 dB
High Pressure Fan with steel blades & Galvanized Housing Move and refresh the stagnant air in your tunnel, greenhouse or commercial warehouse to create a healthy and more productive environment. Our exhaust fans ...
Air flow: 165, 2,500, 3,000, 3,500, 4,000 m³/h
Diameter: 160 mm
Noise level: 72, 70, 74, 75 dB
The mobile exhaust fan convinces by the very flexible application due to its low construction and the low weight. In connection to a suction hose, the exhaust fan is appropriate to the application to ...
Air flow: 100 m³/h - 450 m³/h
Rotational speed: 2,900, 1,450 rpm
Noise level: 45 dB - 67 dB
Produced completely by injection moulding.Polypropylene housing resistant to UV rays and adjustable to 8 positions. High-performance polypropylene impeller with forward curved blades, statically and dynamically balanced, incorporating ...
PLASTIFER
Air flow: 500 m³/h - 1,600 m³/h
Rotational speed: 1,450, 950, 2,900 rpm
Noise level: 57, 45, 70 dB
Produced completely by injection moulding. Polypropylene housing resistant to UV rays and adjustable to 8 positions. High-performance polypropylene impeller with forward curved blades, statically and dynamically balanced, incorporating ...
PLASTIFER
Air flow: 720 m³/h - 2,000 m³/h
Extract Fan Low Pressure Produced completely by injection moulding. Polypropylene housing resistant to UV rays and adjustable to 8 positions. High-performance polypropylene impeller with forward curved blades, statically ...
PLASTIFER
Air flow: 2,700, 3,850 m³/h
Portable extraction fan for welding fumes The portable FACILE extraction fan is particularly suited to protecting the operator from fumes and particulate when working in positions which cannot be reached ...
AERSERVICE EQUIPMENTS SRL
Air flow: 100 m³/h - 19,000 m³/h
Centrifugal fans with forward curved blades in galvanised sheet metal Extraction of air which is clean or with a low volume of particulates, exhaust gases, welding fumes, etc. - Structure: The structure ...
AERSERVICE EQUIPMENTS SRL
Centrifugal fan with forward curved blades in galvanised sheet metal Extraction of air with a low volumes of particulate, exhaust gases, welding fumes, etc. - Structure: The structure of the extraction ...
AERSERVICE EQUIPMENTS SRL
Air flow: 48 l/min - 1,019 l/min
DC fan blowers are typically used in projectors, humidifiers and household appliances. Supply voltage - 12 V, 24 V
Choose the right fan adapted to your installation and filters. Description An efficient filtering system needs to use the right fan adapted to your installation. Airflow, velocity, power, noise level ...
Air flow: 13,400 m³/h
Diameter: 225 mm - 560 mm
Properties • highly efficient EC technology • compact design • backward curved impellers • feet can be offset by 90° • variable discharge direction • integrated control system (EC controller) • speed is 100% infinitely variable Casing Casings ...
Rosenberg Ventilatoren GmbH
Air flow: 28,000 m³/h
Diameter: 225 mm - 560 mm
Properties • flow rates up to 28,000 m³/h • size: 225 - 560 mm (impeller diameter) • asynchronous external rotor motor • backward curved impellers • feet can be offset by 90° • protection class IP54 • thermal class F • connection ...
Rosenberg Ventilatoren GmbH
Air flow: 21,000 m³/h
Diameter: 200 mm - 630 mm
Properties • flow rates up to 21,000 m³/h • size: 200 - 630 mm (impeller diameter) • casing made of galvanised sheet steel • casing position: LG or RD • IEC standard motor, IP55, thermal class F • backward curved impellers • terminal ...
Rosenberg Ventilatoren GmbH
Air flow: 59 m³/h
Diameter: 99 mm
Rotational speed: 3,172 rpm
Range of 100mm domestic centrifugal extract fans for wall or ceiling installations, designed to work in accordance with two different operating modes: -Continuously running operation which can be boosted ...
Soler & Palau
Air flow: 63 m³/h
Diameter: 99 mm
Rotational speed: 3,990 rpm
Range of 100mm domestic centrifugal extract fans for wall or ceiling installations, designed for constant volume continuously running operation with wired boost option, in utility rooms and bathrooms. Trickle ...
Soler & Palau
Air flow: 100 m³/h
Diameter: 98 mm
Rotational speed: 2,000 rpm
Centrifugal fans, with an approximate airflow of 100 m3/h at free discharge, back draft shutter incorporated, body and impeller made of polypropylene, 230V-50Hz motor, IPX2, Class II. Specially designed ...
Soler & Palau
Air flow: 6,100 m³/h - 76,160 m³/h
Rotational speed: 945 rpm - 2,880 rpm
Noise level: 48 dB - 71 dB
... detector ...). Control systems not included in the equipment. Fan: • An extremely robust structure that is able to withstand severe weather changes. • Maintenance switches for actuator and fan disconnection ...
SODECA
Air flow: 527 m³/h - 3,024 m³/h
Rotational speed: 1,460 rpm - 3,540 rpm
Noise level: 38, 45, 49, 52, 42 dB
... F7 + F9 filters. Other combinations on request. • Easy access inspection and cleaning cover with manual fasteners. • Centrifugal fan with backward curved impeller. • Integrated support into the box ...
SODECA
Air flow: 1,374 m³/h - 5,915 m³/h
Rotational speed: 900, 1,400, 1,410 rpm
Noise level: 53 dB - 72 dB
Double inlet centrifugal fans, direct motor EC Technology IE4 with integrated electronics and forward curved impeller, specially designed for high energy efficiency. Fan: • Galvanised ...
SODECA
Air flow: 3,000 m³/h
Vekita+ – In-line units Easy to install. 5 models up to 3000 m3/h. Can be installed indoors and outdoors. Soundproofed version available. Multi-connection version up to VEKITA+ 450. Ultra-flat model VEKITA+ 300. Single-phase motor with ...
Aldes
... service life / Permanent condenser. Can operate on horizontal or vertical axis. Galvanised steel plate body. Centrifugal impeller with backward-curve fan blades, fixed to rotor with dynamic balancing. Possibility ...
Aldes
Air flow: 27,000 m³/h
Velone – Smoke exhaust roof fans CE marking-compliant. F400 Class (400 °C – 120 min) in accordance with EN 12101-3. Airflow range up to 27,000 m3/h. Compact to protect against impacts and weather. ALL-IN-ONE option (built-in ...
Aldes
Air flow: 0.013 m³/s - 0.243 m³/s
Diameter: 200 mm
Rotational speed: 2,565, 2,395, 2,100 rpm
Centrifugal Inline Fan • Standard size 200mm • Air volume flow rates up to 0.243 m3/s • Static pressures up to 465 Pa • Suitable for operating temperatures up to +50℃ • Available in AC All metal ...
ELTA FANS
Air flow: 0.014 m³/s - 0.059 m³/s
Diameter: 125 mm
Rotational speed: 2,690 rpm
Centrifugal Inline Fan • Standard size 125mm • Air volume flow rates up to 0.059 m3/s • Static pressures up to 158 Pa • Suitable for operating temperatures up to +50℃ • Available in AC VL casings ...
ELTA FANS
Air flow: 0.002 m³/s - 0.832 m³/s
Diameter: 100 mm
Rotational speed: 5,000, 3,750, 2,500 rpm
Centrifugal Box Fan • Standard size 100mm • Air volume flow rates up to 0.832 m3/s • Static pressures up to 451 Pa • Suitable for operating temperatures up to +60℃ • Redesigned casing to improve ...
ELTA FANS
Centrifugal fans store significant amounts of energy when running, and if the fan is not correctly matched with the operating conditions the consequences for the plant operator can include ...
... mission-critical air and gas handling products, is pleased to promote the ExVelTM Composite turbo fan. The key to this revolutionary technology is the ExVel turbo fan impeller engineered and produced ...
Air flow: 0 ft³/min - 284,000 ft³/min
... Chicago's Design 10A is a rugged multi-purpose centrifugal fan equipped with an airfoil wheel suited for supply and exhaust air and industrial applications. With energy efficient airfoil blades, the Design ...
CHICAGO BLOWER
Air flow: 0 ft³/min - 156,000 ft³/min
Design 70 High Efficiency Plug Fan The Design 70 wheel was developed for open wheel installations and utilizes a solid, single surface airfoil blade to provide Chicago’s Plug Fan with one of the industry’s ...
CHICAGO BLOWER
... environment. Greater fan efficiency results in lower power requirements and fewer natural resources consumed. Efficiency also influences sound levels. The more efficient fan will run quieter than the ...
CHICAGO BLOWER
Air flow: 6,000 m³/h - 40,000 m³/h
Industrial polypropylene vacuum serve as link to galvanic plants and the scrubber.
• Centrifugal fans made of anti-acidic material • Case made of: PP – PVC • Impeller made of: PP – PVC – FE – AISI316 • Flow rates and prevalence: on request • Atex class fans available on request
Air flow: 330 m³/h - 8,400 m³/h
... allowed 80°C or 150°C if a cooling fan is installed Belt Drive trasmission: Maximum fluid temperature allowed 90°C or 350°C if a cooling fan is installed In case of higher temperatures, some modifications ...
Stiavelli Irio
Air flow: 420 m³/h - 22,800 m³/h
... fluid temperature allowed 90°C or 200°C if a cooling fan is installed In case of higher temperatures, some modifications to the fan structure are needed. TYPICAL APPLICATIONS This type of radial ...
Stiavelli Irio
Air flow: 95 m³/h - 32,400 m³/h
RANGE V (m³/h) = 95÷32400 Pt (kg/m²) = 120÷1900 FEATURES Medium and high pressure radial fans, various volume centrifugal fans and blowers. Forward curved blades ...
Stiavelli Irio
... wide range of mine ventilation requirements. Seven base fan sizes combined with six different hub sizes offer the right fit for all requirements with lower costs and short lead times Total fan efficiency ...
One of the most common fans in Tunnel and Metro ventilation is the Jet Fan. Based on decades of experience and extensive R&D,TLT-Turbo has developed a new generation of standardized and modularized Jet ...
Air flow: 1,000 m³/s
... for supplying fans that are highly energy efficient and able to operate within the harshest environments. For this reason, designing fans that are purpose-built for use in thermal power plants is one ...
Your suggestions for improvement:
Centrifugal fans have a spiral shape, their turbine displacing air by centrifugal force. The suction inlet is axial and the outflow is radial. They are common in public and industrial facility ventilation.
ApplicationsThese devices are used for ventilation, heating and air conditioning, for supplying air to ovens and for tunnel ventilation. Different models exist for clean, dusty, dry, humid or corrosive air.
TechnologiesSuch fans are composed of an inlet device, a paddle-wheel turbine, a streamlined spiral case (the scroll) and a base. The inlet and the turbine can have single or double intakes. Fan geometry can favor either flow or pressure.
A forward curved impeller has blades curved in the direction of fan rotation. Straight radial blades are self-cleaning and relatively unaffected by dust and humidity, but are comparatively less efficient. If the concave side of the blades faces away from the direction of rotation, it is a backward curved impeller.
The motor coupling is usually direct and fixed-speed. It also can use variable-speed V-belts. Fans are carefully designed to achieve optimum stability and minimum noise. They are made of aluminum or of stainless steel. The blades are welded or bent.
Consider the characteristics of the air to be moved and the required airflow rate or air pressure. Load curves can help determine the technical parameters necessary for fan dimension calculations.
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining