- Metrology - Laboratory >
- Analytical Instrumentation >
- FID chromatograph
FID chromatographs
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... stability. Along with proven strengths of our GC platform, the Clarus 590 GC features a wide-range flame ionization detector (FID), a new high-performance capillary injector with decreased reactivity, ...
PerkinElmer
... LECO's QuadJet™ SD is the ideal solution for samples which arrive in your lab. By combining the sensitivity of Flame Ionization Detection (FID) with the increased chromatographic resolution of comprehensive ...
ABB process gas chromatographs perform real-time analysis of the chemical composition of a process sample or stream - crucial for on-spec processes and productivity. PGC5000B Smart Ovens target simple applications with ...
ABB process gas chromatograph portfolio includes specialty gas chromatographs (process simulated distillation, temperature programmed, fast temperature programmed and total sulfur). The PGC5000 Series ...
... require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand ...
Agilent Technologies - Life Sciences and Chemical
Designed for optimum reliability and flexibility, the Rosemount 700XA Process GC provides extended gas composition analysis with remote operation capabilities in an explosion-proof, field-mountable design. This reduces the need for elaborate ...
Emerson Automation Solutions - ROSEMOUNT
The Baseline PetroAlert® Model 9100 incorporates the sensitivity, stability, linearityand selectivity of a flame ionization detector (FID), making it the ideal choice for the analysis of aliphatic hydrocarbons. Designed ...
... inorganic compounds. Detector options include Photoionization (PID), High-sensitivity Photoionization (HS-PID), Flame Ionization (FID), Thermal Conductivity (TCD), or Pulsed Discharge Ionization (PDD).
BevAlert® Series 9100 GC Designed Specifically for CO2 Applications The Baseline BevAlert® Series 9100 Gas Chromatograph (GC) is a specialized instrument utilized by specialty gas manufacturers and the food and beverage ...
... C/min, increment 0. 1°C Constant Temperature Retention time: 0 ~ 655 min, increment 1 min Detector: Hydrogen Flame Ionization Detector (FID) Sensitivity: M ≤ 1 ×10-11 g/s(C16) Best testing results: ...
... research in cutting-edge science and military technologies Features - Newly designed, high performance HRGC - Double FID detectors in the basic type with wide accessory options such as GC8000-TCD thermal conductivity ...
What separates you from everyone else. Maximizes peak capacity to enhance MS sensitivity Provides the lowest carryover, complementing MS sensitivity and extending MS linear dynamic range Has been purposefully engineered for ...
Waters
The TRSMEDOR is an automatic and isothermal gas chromatograph dedicated to sulfur compounds analysis (H2S, mercaptans and sulphides) in different matrices. Two versions exist : the TRSMEDOR ppm which measures at ppm ...
CHROMATOTEC
... Class I, Division 2, group C&D and ATEX zone I and II. Description : The MEDOR Exp is an automatic and isothermal gas chromatograph dedicated to sulfur compounds analysis (H2S, mercaptans and sulphides) in different ...
CHROMATOTEC
... and monitoring of sulfur compounds in natural gas Description : The energyMEDOR is an automatic and isothermal gas chromatograph dedicated to sulfur compounds analysis (H2S, mercaptans and sulphides) in different ...
CHROMATOTEC
... is a latest model gas chromatograph equipped with large LCD. It has the function of Power-down, Overheat, gas-cutting protection, can suggestthe user in English and fifth-ordertemperature-programmed. This kind ofgas chromatograph ...
... spectrometry is actually using mass spectrometry as a universal detector. There are many detectors of chromatography, such as TCD, FID, ECD, FPD and NPD, etc., each detector has a limited scope of application, which is ...
GC machine Laboratory GC Gas Chromatograph With Optional Detector FID/TCD/FPD gas chromatography Introduction GC-9802 gas chromatography, is a multifunctional laboratory analytical instrument ...
... software The MultiDetek3 is the latest development of our popular range of compact industrial gas chromatographs. It is more than a simple gas chromatograph: it’s a modular process GC instrument, that ...
Compact Gas Chromatograph - LDetek MultiDetek2 Modular and Flexible Multi-Detector Configuration. Features • Pre-configurable according to application requirements: ready-to-use device. • Stand-alone instrument ...
GC in Explosion Proof Package - LDetek MultiDetek3 EX Multi-Stream Gas Chromatograph System for Hazardous Areas Features • Explosion proof for use in Zone 1 and Zone 2 • Integrate multiple instruments and sampling ...
... conductivity detector (TCD) for ppm%-level impurity detection in gases; high sensitivity hydrogen flame ionization detector (FID) to realize the detection of hydrocarbons and other organic substances ...
Shanghai Huaai Chromatography Analysis Technology Co., Ltd.
GC-9580-HD automatic special gas chromatograph for transformer oil is a new type of chromatograph, which integrates automatic transformer oil injection system and chromatographic analysis system introduced ...
Shanghai Huaai Chromatography Analysis Technology Co., Ltd.
HuaAi chromatography recently launched a GC-9780A automatic transformer oil dedicated portable chromatograph.The device is connected wirelessly by advanced Internet of Things technology and is powered on with one button.Fully ...
Shanghai Huaai Chromatography Analysis Technology Co., Ltd.
... Injector On-Column Injection Unit Direct Injection Unit Programmed Temperature Vaporization Injector Detectors Flame Ionization Detector Flame Photometric Detector Thermal Conductivity Detector Flame Thermionic ...
Shimadzu Europa
Maximize the operational efficiency and profitability of your lab with the Thermo Scientific™ TRACE™ 1600 Series Gas Chromatograph and its unique modular concept for optimized instrumental usage. The TRACE 1610 GC is ...
The GC fully absorbs advanced technology from similar foreign products and adopts industry-leading manufacturing technology and processes in China, ensuring the reliability and trouble-free opération time of the instrument. It can not ...
... -A80 comprehensive mud logging gas chromatograph, which conforms to standards of logging gas chromatograph. Adopted several kinds of domestic and foreign advanced technology, HK-A80 is also equipped with ...
... phase 10 platform temperature programme with a temperature range of 5 °C to 400 °C. Features an APC controlled Flame Ionization Detector (FID) with high sensitivity for a range of analyses. Built-in provision ...
... Technical Specifications Configuration: Bench-top or rack-mount 19″ Power: 230 V AC, 50/60 Hz, 2 Amp Detector: FID Flame Ionization Detector Carrier Gas: Pure Hydrogen (99.99%)
... data engineers.Several detectors can be equipped in this GC such as (FID,TCD...).According to the testing requirements for welding shielding gas, a portable gas chromatograph analysis with TCD ...
EIT Solutions Co., Ltd
The OGC is a gas chromatography equipped with FID detector and two Capillary column and multi port valve and it’s software and hardware is tuned for analyzing light hydrocarbon in rang of C1 to C5 or C1 to C8. The OGC ...
... LCD displays. 3.PVC keyboard, easy to operate. 4.Dual CPUs design, excellent electromagnetic interference protection. 5.Dual FID detectors, dual gas circuits system, self-diagnosis function. 6.Ignite automatically. 7.Constant ...
Gas Chromatograph » Automatically apply the working curve of toluene to calculate the total content of all unknown peaks in the spectrum. » It can calculate the content of each component and the total content of ...
MAG PROCESS GAS CHROMATOGRAPH FOR ANALYSIS OF LIQUEFIED HYDROCARBONS This chromatograph in explosion-proof design is intended for on-line automatic measurement of the content of organic and non-organic ...
BACS LLC
... Self-protective function: 1) Overrun temperature protection;2) Short circuit hint;3) TCD filament protection;4) FID flame out hint;5) PFD exposed-light protection;6) Keyboard locking with password; etc.,ensuring ...
Beijing Beifen-Ruili Analytical Instrument
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining