|
|
Ion chromatography should be fun and should not get on your nerves. Metrohm does everything it can to ensure that your IC system will work reliably with minimum service, maintenance and costs. Metrosep separating columns stand for good quality, a long working life and excellent results.
Some of our new columns for ion chromatography:
Metrosep Dual 4 - 25
Separation of some standard anions in less than a minute, e.g. nitrate in just 45 seconds - faster than many FIA systems.
Metrosep A Supp 7 - 250
Separation column for the simultaneous determination of the standard anions, the oxo halides and dichloroacetic acid.
Metrosep A Supp 10 - 50
Allows very fast separations of the standard anions. Ideal for straightforward separation tasks and non-critical matrices.
Visit our homepage to see our whole range of ion chromatography columns.
|
|
GC Columns
Varian, Inc. FactorFour Columns:
Highly Inert Capillary Columns with the Lowest Bleed Specifications -Guaranteed
- Accurate peak identification - achieving more reliable results
- Superior response for traces - better quantification
- Enhanced detector performance - increasing productivity and reducing costs
- Faster stabilization - longer instrument uptime, so increasing your productivity
The Varian FactorFour family of capillary columns provides a complete range of stationary phases suitable for industrial, toxicology, chemical and environmental applications. FactorFour highly inert ultra-low bleed columns offer a bleed specification up to four-fold lower than comparable competitive products.
|
|
HPLC Columns
Fast LC Columns
Pursuit XRs Ultra 2.8 and Pursuit UPS 2.4 are designed to offer faster analysis with existing LC and LC/MS systems. They allow chromatographers to analyze samples faster while achieving higher resolution and reducing the cost per analysis without the need for capital investment. Both columns provide:
Method Development Flexibility - lower backpressures allow flows and mobile phases to be tailored to meet your applications needs
Maximum value. High performance separations achieved without the need for a new ultra high pressure system
|
|
|
Agilent J&W GC Columns are designed and manufactured to offer excellent and reproducible performance for the benign to the most difficult types of samples. With the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds,and the tightest column-to-column reproducibility - Agilent GC columns are of higher quality and perform better than any other columns on the market. In addition to the column selections below, Agilent also offers custom columns to meet your needs.
|
|
GC Columns
Hamilton's PRECIX GC columns are designed for environmental analysis, quality control of foods and many more applications.
|
|
Heliflex® AT™-1
- Excellent general purpose columns
- Similar to DB™-1, Rtx™-1, SPB™-1, SPB-Sulfur, SP™-2100, HP™-1, HP™-101, ULTRA™-1, BP™-1, CP-Sil™-5-CB, 007™-1, OV™-1, SE™-30, DC™-200, RSL™-150,RSL-160, PE-1, ZB-1
Specifications
Phase: 100% Dimethylpolysiloxane
Polarity: Non-polar General Purpose Column
USP Designation: G1, G2, G38
Ideal for: General Purpose
|
|
|
Agilent J&W GC Columns are designed and manufactured to offer excellent and reproducible performance for the benign to the most difficult types of samples. With the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds,and the tightest column-to-column reproducibility - Agilent GC columns are of higher quality and perform better than any other columns on the market.
|
|
High Pressure Glass Columns & Accessories:
Adjustable Endpieces for High Pressure Glass Columns
O-Rings for High Pressure Glass Columns
Packing Funnels for High Pressure Glass Columns
POROS® High Pressure Glass Columns
Replacement Column Bodies for High Pressure Glass Columns
PEEK™ Columns & Accessories:
Self Pack® Empty Columns, PEEK™
Self Pack® Packing Device for PEEK™ Columns
Spare Parts for Legacy Systems:
BioCAD® Chromatography Instrument Spare Parts
Stainless Steel Columns & Accessories:
Self Pack® Empty Columns, Stainless Steel
Self Pack® Packing Device for Stainless Steel Columns
Self Pack® Stainless Steel Column Adaptor
|
|
|
Acclaim® is a versatile family of reversed-phase HPLC columns. Here we present a selection of applications that show how these columns perform for the kinds of analyses that you care about.
|
|
Hamilton's polymeric HPLC columns combine the inertness and pH stability of polymeric supports with the pressure stability and durability of silica-based columns. Column packings are available for reversed phase, anion exchange, cation exchange, and ion exclusion separations.
Hamilton offers 19 different polymer-based HPLC columns for reversed phase, anion exchange, cation exchange and ion exclusion separations. Two silica-based C8 and C18 column materials are available for reversed phase separations.
|
|
|
These Drying Cartridges are designed for convenience and safety. Simply thread the 32 or 45mm bottom cap onto System 45 glassware, insert drying cartridge on top of the cap, thread top cap over cartridge. Desiccant may be placed directly between the two caps by placing two Zytex® liners in the caps and filling the top cap with desiccant. Drying cartridges may also be used with all glassware using GL-32 or GL-45 threads. Supplied with top and bottom cap and one drying cartridge
|
|
GraceSmartTM HPLC Columns
GraceSmart WebSpotlight
- Smart Quality
- Smart Performance
- Smart Value
Grace Davison Discovery Sciences sets a new standard in HPLC columns. From the silica particle to the finished product, our streamlined manufacturing delivers smart quality and smart performance. GraceSmart™ HPLC Phases use high purity silica and are monomerically bonded with uniform coverage. This translates into symmetrical peaks for acids/bases, and predictable reversed phase selectivity. GraceSmart™ columns show similar or better efficiency and asymmetries for challenging base and acid components in comparison to industry leading columns.
|
|
|
|
|
|
IC and RFIC Columns
Hydroxide-Selective Anion Columns
Hydroxide-selective, anion-exchange columns are optimized for use with a hydroxide eluent. Choose a hydroxide eluent column for use with an eluent generator for gradient work or trace analysis. Hydroxide eluents for isocratic or gradient elution are very convenient with Reagent-FreeTM Ion Chromatography (RFICTM) technology using electrolytic generation of the eluent. RFIC technology simplifies methods development for hydroxide-gradient systems since the electrolytic eluent generator provides gradient methods that are simpler to use than manually prepared isocratic eluents. Modern continuous-eluent-suppression systems are designed to suppress hydroxide eluents, even at very high eluting strengths.
Carbonate-Based Anion Columns
Each of these anion-exchange columns are optimized for use with a carbonate/bicarbonate eluent. Carbonate eluent columns are useful for well-characterized isocratic separations, including regulated methods for drinking and wastewater.
Specialty Anion Columns
Specialty columns are anion-exchange columns that can be used with nonsuppressible eluents such as nitric acid in combination with a variety of detection modes, including amperometric and UV-VIS detection.
Cation Columns
Cation-exchange columns are designed for high-resolution separations of inorganic cations, ammonium, amines, and transition metals. These columns provide an excellent approach to separations of alkylamines, alkanolamines, and quaternary ammonium ions.
Transition Metal Columns
Transition metal columns are designed for determination of transition and lanthanide metals in diverse sample matrices.
Ion Exclusion Columns
In ion-exclusion separations, Donnan exclusion causes strong acids to elute in the void volume of the column. Weak acids that are protonated in the acidic eluent are not subject to Donnan exclusion and penetrate into the pores of the packing. Separation is accomplished by differences in pKa, size, and hydrophobicity.
Trap Columns
Trap columns are short columns installed in the system to prevent unwanted analytes from interfering with the separation of your analytes of interest. IonPac trap columns contain high-capacity, low-efficiency, ion-exchange resin. The columns strip trace contaminants from the eluent and prevent them from reaching the guard and analytical columns. The trap is installed in the eluent line prior to the injection valve to prevent spurious peaks during gradient chromatography. These trap columns are specialized columns that remove unwanted analytes from the sample, and are installed before the analytical column.
Concentrator Columns
IonPac concentrator columns are designed primarily for high purity water analysis. The concentrator column strips ions from a measured volume of an aqueous sample matrix, concentrating the analyte species and lowering detection limits.
|
|
KNAUER HPLC and UHPLC columns
KNAUER offers an extensive range of columns and phases for HPLC. Our more than 35 years of experience in the field of liquid chromatographic separation techniques is evidenced by each and every column we deliver. High performance quality sorbents such as our very own Eurospher provide for excellent results. The process of manufacturing our HPLC separation columns has been thoroughly optimized. Strict criteria guarantee outstanding quality in batch-to-batch reproduction.
We design and manufacture HPLC column hardware ranging from 2 mm ID to 62 mm ID. Available column lengths range from 5 mm up to 300 mm. The column hardware is made of high quality stainless steel with a specially treated inner surface. The new Vertex plus column hardware has been further enhanced in terms of stability and lowest dispersion. PEEK columns for biocompatible applications are also available. Many models can be equipped with an integrated precolumn.
|
|
Smartline Column Oven 4050
Optimally suited for the majority of HPLC applications.
This column oven features heating and active Peltier cooling in the range from 10° below room temperature up to 140°C. Its contact oven design and equilibrating of the mobile phase before the column inlet ensure an even temperature distribution over the entire column for improved separation results. Active column eluate cooling minimizes peak broadening and noise/drift in subsequent detection.
|
|
Smartline Column Oven 4050
Optimally suited for the majority of HPLC applications.
This column oven features heating and active Peltier cooling in the range from 10° below room temperature up to 140°C. Its contact oven design and equilibrating of the mobile phase before the column inlet ensure an even temperature distribution over the entire column for improved separation results. Active column eluate cooling minimizes peak broadening and noise/drift in subsequent detection.
|
|
|
|