The National Electrical Code requires GFCI protection of receptacles located outdoors and in bathrooms, garages and spa areas. This GFCI circuit breaker provides protection against overloads, short circuits and ground faults. It detects very low levels of electrical current leaks (ground faults), and acts quickly to shut off power, preventing serious shock.
Features and Benefits
* UL Listed (Molded Case Circuit Breakers No. 489 and Ground Fault Circuit Interrupters No. 943).
* Class A (.005 ampere ground fault trip level).
* Available from 15-30 Amps 1 Pole, 15-50A 2 Pole.
* Voltage is 120 and 240 volt ratings
|
|
Hitachi Mould Case Circuit Breaker ( Fuse-Free Breakers ) & Earth Leakage Breakers are designed for circuit protection of low-voltage distribution systems. They are suitable for applications as main breakers, protection of branch, feeder circuits and connected apapratus.
Quick contact inspection/ Easy contact replacement.
Easy wiring/ High safety/ High Reliability.
DIN rail mounting mechanism.
|
|
- Protection against overload, short-circuit and ground fault.
- Offering economical solution with compact and increased interrupting
capacities.
- Employing a fixed thermal and fixed magnetic trip.
- Frames made of rigid materials of engineering plastics
- Offering the physically same size with MCCBs.
|
|
|
|
|
|
Over the past century, GE has designed and manufactured literally tens of thousands of medium and high voltage circuit breakers. Although many of the older designs are no longer manufactured, many units remain in service. GE can deliver solutions for these breakers without the cost and downtime associated with complete equipment replacement. If you have any of the following breakers in service, we can provide parts or engineered solutions to support your maintenance needs:
Features and Benefits
* Parts designed and manufactured to the original or improved specifications.
* Parts in stock for fast delivery when you need them.
* Engineering support to provide support for your specific requirements.
* Extend the service life of your equipment with Genuine GE Parts, designed by the original manufacturer assuring reliable fit and performance.
* Increase rating capacity with packaged engineered solutions.
* Save time with easy to install original parts
* On-site service installation or supervision optionally available.
|
|
|
|
|
|
Gerapid high speed DC circuit breakers are single-pole circuit breakers designed for use in high energy, high reliability DC power distribution systems. They are suitable for protection of mains and semiconductors (converters/rectifiers) in railway and industrial applications. Feeder circuit breakers and rectifier circuit breakers are available with operating currents up to 8,000ADC and operating voltages up to 3600VDC. They have a very high interruption capacity combined with a current limiting characteristic.
Innovative materials, superior circuit breaking capacity and outstanding dielectric performance ensure service continuity and protection during adverse system events. The technology and quality of these circuit breakers produce high reliability, extended maintenance intervals and uncomplicated serviceability for all fixed installations
Features and Benefits
- Ratings up to 8000A and 4000 Vdc (3,600 Vdc, ANSI)
- IEC 947-2, EN50123-2, and ANSI C37.14 Certifications
- Solenoid drive (integral control unit, mechanically latched, no auxiliary power required to keep contacts closed)
- Available electrodynamic release for very high speed switching
- Two Stage contact system extends life of main contacts
- Compact, enclosed construction
- Full range of accessories, including up to 10 auxiliary contacts
Applications
- Traction power (light rail transit, tram, subway, maglev, etc.)
- Industrial plant protection (electrolysis plants, iron and steel mills, etc.)
- Mining
- Chemical, petrochemical
- Power generation
- Research/experimental (e.g., physics, particle accelerator protection)
|
|
Features and Benefits :
- Parts designed and manufactured to the original or improved specifications.
- Parts in stock for fast delivery when you need them.
- Engineering support to provide support for your specific requirements.
- Extend the service life of your equipment with Genuine GE Parts, designed by the original manufacturer assuring reliable fit and performance.
- Increase rating capacity with packaged engineered solutions.
- Save time with easy to install original parts
- On-site service installation or supervision optionally available.
Product Scope:
- MagneBlast Medium Voltage vertical lift circuit breakers.
- FK, FKD, FKA and VIB medium and high voltage outdoor distribution breakers.
- ARA generator breakers.
- ATB high Voltage transmission breakers.
- Type MC and AG dc breakers.
|
|
Siemens high-voltage circuit-breakers offer the optimum technical and economical solution for every requirement. Depending on the application and the voltage level, they are equipped with the following combinations of arc quenching principle and operating mechanism:
* Self-compression principle with stored energy spring mechanism
* Puffertype with hydraulic mechanism
All the live- and dead-tank circuit-breakers, as well as the gas-insulated switchgear (GIS), are equipped with the same components. Longevity, reliability and highest availability in all climate zones in the world distinguish Siemens high-voltage circuit-breakers from all others.
|
|
808
Single pole purely magnetic circuit breaker,
fast acting, for pcb mouting
8340-G2
Hydraulic-magnnetic circuit breaker, push-pull actuation, threadneck panel mounting
8340-G2-DC110V
Hydraulic magnetic circuit breaker with push-pull actuation for DC110V applications
8340-F
Toggle-operated hydraulic-magnetic
circuit breaker, flange mounting
8340-T
Toggle-operated hydraulic-magnetic
circuit breaker for rail mounting
8345
Toggle-operated hydraulic-magnetic circuit breaker, flange mounting, ratings up to 125 A
8345-DC110V
Toggle-operated hydraulic-magnetic circuit breaker, flange mounting, ratings up to 125 A
|
|
Description
Special technical features of live-tank design: On live-tank circuit-breakers, the interrupter chamber is arranged in the insulator which can be either porcelain or of a composite material, and is at high potential; with the voltage level determining the length of the insulators for the interrupter chamber and the insulator column.
|
|
|
|
|
|
General description:
EntelliGuard® G circuit breakers are the newest line of GE low-voltage circuit breakers, the next step in the evolution of a line known for its exceptional reliability and performance. They are available in 3- and 4-pole designs rated from 400A to 6000A, with fault interruption ratings up to 150kAIC
Integral to the EntelliGuard G breakers are the new, state-of-the-art EntelliGuard TU Trip Units, which provide superior system protection, system reliability, monitoring and communications.The breaker-trip unit system delivers superior circuit protection without compromising either selectivity or arc flash protection.
The EntelliGuard breaker-trip unit system demonstrates yet again GE's core competencies in reliable electric power distribution, circuit protection and personnel protection.
Modern economic reality and the regulatory environment demand system performance while recognizing the need to protect against the arc flash hazards that expose maintenance personnel to dangerous levels of heat, electrical energy, debris from damaged equipment and concussive forces. The challenge is to provide both better personnel protection by minimizing arc flash hazards and maintain electrical power to mission-critical loads. But these objectives often seem to conflict, pitting the speed and sensitivity required to optimize safety against the sequence of operations and interlocking required to maximize power system availability.
|
|
Main Circuit Breakers
100 to 225A. THQM main breakers are configured to allow top or bottom feed without modification.
Feeder Plug-in Circuit Breakers
15 to 200A. Choose from 1/2" THQP or 1" THQL & TQDL breakers with options for 1 to 3 poles. THQP breakers allow the use of smaller load centers that save money and space in both new installations and service upgrades.
Ground Fault Circuit Interrupter (GFCI)
15 to 50A. 1" THQL breakers with options for 1 or 2 poles. This GFCI circuit breaker provides protection against overloads, short circuits and ground faults.
Arc Fault Circuit Interrupter (AFCI)
Branch/Feeder AFCI - 15 to 20 amp, ½" or 1", 1 or 2 pole
Combination AFCI - 15 to 20 amp, 1", single pole
|
|
Features and Benefits:
- True closed-door drawout design
- Field-installable accessories
- One standardized wiring diagram for all breakers with dedicated secondary disconnect and breaker accessory points
- Trip unit display through the breaker escutcheon with metering and trip information
- Three choices of solid-state trips with function and cost variability:
Power+ with basic overload and short circuit protection, and optional ground fault trip target
MicroVersaTrip Plus with full range of overcurrent and ground-fault protective functions
MicroVersaTrip PM with advanced metering, communications and protective relaying options.
- Maintenance convenience and safety
- Maximum selectivity with downstream devices
- Minimum downtime
|
|
|
Terasaki has a full range of Moulded Case Circuit Breakers from 30A to 4000A, and Air Circuit Breakers from 800A to 6300 A.
|
|
|
Raychem PESD electrostatic discharge protection devices are designed for I/O port protection in high-speed data transmission applications, PESD devices shunt ESD away from sensitive circuitry in electronic devices. The PESD devices provide exceptionally low capacitance, they perform better than other comparable components in TLP (transmission line pulse) testing, as well as IEC61000-4-2 testing, especially after multiple hits (up to 1000). The devices offer a lower trigger voltage and a lower clamping voltage than typical polymer ESD (electrostatic discharge) devices, resulting in improved protection of sensitive electronic components.
|
|
|
|
|
|
Features and Benefits :
- Modular design with interchangeable footprint and parts for all breaker sizes
- Comprehensive mechanical and electrical interlocks for operating safety
- Virtually maintenance-free vacuum interrupter contacts
- Direct reading erosion indicator for vacuum interrupter contacts
- Superior vacuum interrupter technology
- Reliable, quite arc interruption
- Extensive factory testing
- Operator convenience
- Reduced maintenance required over product life
- High degree of reliability and product integrity
Product Scope:
- Modular, standardized frame size, regardless of voltage or interrupting capacity.
- Most of the frame parts, primary conductors, disconnects, and mechanisms are interchangeable throughout the breaker product line
- Can be used in systems rated 4.16kV - 250 MVA through 13.8kV - 1500 MVA at 1200, 2000, 3000, 3500, and 4000 A (in fan-cooled equipment)
- Ratings 27kV 16kA & 25kA, 1200 & 2000A are available.
- Designed and tested to all applicable ANSI, IEEE , and NEMA standards, and carry a UL and CSA label.
|
|
|
The heart of the GE PowerVac® circuit breaker is the vacuum interrupter. GE pioneered this interrupter technology beginning with experimental work in the 1920's. Today, the vacuum design remains superior to other arc interruption technologies by providing a smaller footprint and simpler design.
|
|
Application - Miniature circuit breakers ETIMAT DC are
used for protection of conductors in direct current
electric circuits. 1-pole circuit breakers are used for
voltages up to 220 V d.c.
and for higher voltages (up to 440 V d.c.) 2-pole circuit
breakers with poles connected in a series.
When connecting the MCB ETIMAT DC man must pay
attention to polarity.
If connected in a wrong way, the MCB can be destroyed.
You cannot use two 1-pole MCBs instead of one 2-pole MCB.
|
|
Q-Line Miniature Circuit Breakers
15 to 100A. THQB and THQC types. Available in bolt-on and Cable-in Cable-out (lug-lug) versions.
E2000 Miniature Circuit Breakers
0.5 to 63A. These miniature circuit breakers offer superior supplemental overload and short circuit protection. The E2000 line has two levels of interruption capacity, 6 kAIC and 10 kAIC.
|
|
Field finable
accessories
J Short-circuit capacity 6kA (EN 60898)
1 Tripping characteristic
B,C,D
Application
Domestic and commercial distribution
Rated voltage: 230V / 400V-
Frequency: 50 / 60 Hz
Calibration temperature: 30°C
Terminal capacity: 35 mm2
Electrical endurance: 30,000
Mechanical endurance: 40,000
Poles: 1p 1p+N 2p 3p 3p+N 4p
Mounting: 35mm symmetrical DIN rail (EN 50022-DIN 46277)
Standards: EN 60898, EN 60947-2, EN 20317
Nominal current ratings from 0.3 to 63A
The TemDin2 range of Miniature Circuit Breakers have been designed for protection of electrical installations against overload and short circuits.
Tripping curves
The TemDin 2 series of Miniature Circuit Breakers are manufactured in accordance with EN 60898 (tripping characteristics B, C and D)
- Curve B: magnetic trip threshold = 3 - 5 In
- Curve C: magnetic trip threshold = 5 - 10 In
- Curve D: magnetic trip threshold = 10 - 20ln
|
|
Nominal current ratings from 10 to 40A
Miniature circuit breakers designed for protection of
electrical installations against overloads and short circuits
Features
- Short-circuit capacity : 6kA ( EN 60898 )
- Tripping characteristic : C
- Application : Dommestic distribution
|
|
|
The "Record Plus" family of circuit breakers has been developed as a line of aesthetically and technically coordinated protection devices for LV distribution and control applications.
|
|
. Types: BK series, BF series, BS series, FB series, RK series
2. Ratings
(1) Miniature Circuit Breakers
1) BK series
- BKN: 1 to 4pole up to 63A & 6kA (IEC60898)
- BKN-b: 1 to 4pole up to 63A 10kA (IEC60898)
- BKH: 1 to 4pole from 63 to 125A 10kA (IEC60947-2)
2) BF series
- 6~50A Max 2.5kA at 415VAC (IEC60947-2)
3) BS series
- 6~30A, 1.5kA at 110/220VAC
4) FB series
- 3~30A, 5~50A, 60~100A, 2.5kA at 460VAC 2, 3pole
(2) Residual Current Devices: RK series
1) RKN type (RCCB): Confirming to IEC61008, Protection against ground fault, 25~63A, 30, 100, 300mA
2) RKP type (RCBO): Confirming to IEC61009,
|
|
Modular circuit-breakers up to 63A
Description
Nominal current: 1 to 63A
Large choice of breaking capacities and tripping curves: B,C,D...
Compliance with standards: IEC EN 60898 or IEC 60947-2 depending on the version, certified by national official authorities
Suitable for isolation in accordance with industrial standards: IEC 60947
Operating voltage: up to 440 Vac, insulation voltage: 500V
Optional add-on earth leakage modules: C60 Vigi
Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
|
|
|
|
|
|
Low voltage moulded case circuit breakers are used for the switching and protection of power supply cables, motors
and other electrical equipment against overloads and short circuit faults. It provides, beside protection function other
functions as remote ON/OFF operation, undervoltage protection, main switch, ...
They are available in range from 16 A up to1600 A in 3 and 4 pole versions.
Advantages:
- Small dimensions,modular sizes
- Possibility of field-instalable accessories - up to 630 AF series 2
- High short circuit breaking capacity (up to 100 kA)
- Fast break mechanism (F.B.M.)
- Reduced energy let throught I2t - minimises thermal stresses
- Reduced tripping time - minimises damage after fault
- Reduced peak short current ampacity - minimised electrodynamic stresses on conductors and
protected equipment
- Installation on mounting plate, 125 AF also on DIN-rail
- Wide range of accessories
- Compact design with high mechanical strenght
- High withstand voltages (8 kV a.c.)
- Voltage level up to 690 V a.c. and 250 V d.c. - only MCCB's with thermal-magnetic triping unit
- Direct opening - recommendation according to standard IEC 60204-1 - up to 630 AF series 2
- Common internal accessories - up to 630 AF series 2
- Visual safety
- Unsurpassed flexibility
|
|
|
SN moulded case circuit breakers are used for switching and protecting low-voltage installations in larger residential properties and business as well as industrial buildings. They ensure reliable protection against overload and short circuits, and can also be used as a main disconnection switch. Rated currents of SN moulded case circuit breakers are in the range from 16 A to 1600 A.
|
|
|
|
|
|
Record Plus™ Thermal Magnetic Trip
3 to 100A. The FC100 and FB100 Record Plus breakers provide a new standard of performance offering multiple levels of interruption capacities, global code approvals, compact size, dual AC/DC ratings, and a broad range of accessories.
Record Plus™ Electronic Trip
125 to 600A. The FG600 Record Plus breaker offers the highest short circuit ratings in the industry, all in a traditional 400A frame.
Spectra RMS™ Electronic Trip
15 to 1200A. These industrial SE150, SF250, SG600 and SK1200 breakers have a digital, solid state, RMS sensing trip system with field installable, front-mounted rating plugs to establish or change the breaker ampere rating.
Thermal Magnetic
15 to 1200A. Our industrial thermal magnetic E150, F225, J600 and K1200 breakers provide a proven, cost effective solution.
Mag-Break® Motor Circuit Protector
Magnetic only circuit breakers. Available in frame types E, F, J, K, and Tri-Break.
Lighting Circuit Breakers
15 to 100A. TEY breakers available with plug-in or bolt-on mounting options.
|
|
|
|
|
|
The majority of distribution systems are designed to an ultimate circuit rating (lcu). An lcu rated MCCB provides the optimum protection in terms of safe and economical selection.
Certain applications may require protection wich is designed to the more onerous service short circuit rating (lcu).
Terasaki's TemBreak Plus range can provide a wide choice of MCCBs with superior lcs ratings up to 85kA at 440V AC.
lcu=o-co 2 full short circuits
lcs=o-co-co 3 full short circuit
All TemBreak Plugin and drawout MCCBs are fitted with a safety trip as standard. If an attempt is made to remove an MCCB while ON it will automatically trip.
The neutral pole of all TemBreak MCCBs are of early make / late break design. This eliminates the risk of abnormal line to neutral voltages which may damage sensitive electronic equipment.
TemBreak MCCBs from 125AF to 1600AF are suitable for isolation as defined by IEC 947-2. Positive Contact Indication (PCI) is achieved via the toggle mechanism. Padlocks can only be installed if the contacts are fully open or closed.
|
|
RCCB Record Plus: FD63/160 frame size
Rated at 160A, the FD63/160 frame size is designed for use in both a DIN-rail environment with modular equipment and in industrial applications. It is supplied with IPXXB terminals suitable for direct connection of one or two conductors totalling up to 95 mm² and is available as a thermal-magnetic breaker, a moulded case switch, and as a magnetic-only motor circuit protector.
The FD63/160 bridges the gap between residential miniature circuit breakers and industrial moulded case circuit breakers.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI
3 and 4 pole versions available
FD63 to 63A and FD160 to 160A
Full range of add-on accessories, including:
thermal magnetic/magnetic trip units
auxiliary contacts
completely integrated add-on devices available
rotary handles
electrical operators
connectivity - 60 mm system
|
|
1. General
Meta-MEC MCCBs shall comply with IEC 947-1 and 947-2 standards or with the corresponding standards applicable in the
member countries (EN 60 947-1, 2) :
- Rated operational voltage of 600 V AC (50/60 Hz)
- Rated insulation voltage of 690 V AC (50/60 Hz)
- Suitable for isolation, as defined by IEC 947-2
- ISO 9000 standard.
2. Types & Ratings
- AB type, GB type, UL listed type
- It covers all ratings from 3A to 1600A.
3. Application
- Line protection
- Motor/generator protection
- Starter combination
4. Type of trip unit
- Thermal-magnetic release
- Electronic release
- Hydraulic-magnetic release
- Magnetic release only without thermal trip
5. Certification: KEMA CB certification, CE document of conformity, UL, CCC
|
|
630 A to 3200 A moulded case circuit-breakers
Description
Nominal current from 630 to 3200 A
2 breaking capacities:200kA at 440V - 75kA at 690V for 630 and 800A LB frames
4 breaking performances from 50 to 150 kA at 415 V
Voltage rating:up to 690 V
2 physical sizes from 630 to 3200 A
A single pole pitch of 70 mm
3 and 4-pole versions
solation with positive break indication
4 Micrologic control units enriched by measurement, energy management and network analysis functions
Earth leakage protection built into electronic protection Wide range of common auxiliaries and accessories interchangeable on site
Compliance with international standards IEC 60947-1 and 2, IEC 68230 for type 2 tropicalisation
Compliance with specifications of marine classification companies:Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
|
|
|
|