The TemBreak series offers the models of the 800A to 1600A frames with the breaking capacity up to 125 kA, and this series consists of thermal adjustable type and electronic type that allows you to select the most suitable breaker for your system
Features of the TemBreak Electronic Moulded Case Circuit Breaker:
- Long time delay trip, short time delay trip, and instantaneous trip are available as standard.
- All of long time delay trip, short time delay trip, pretrip alarm, and ground fault trip can be adjusted. The rated current can be adjusted in a range between 50% and 100%. For short time delay trip, ramp characteristics can be selected with the switch to enable selective coordination with lower breakers and fuses.
- The multi-protective device uses the r.m.s. value control. It samples peak current every 0.5msec. to calculate a root-mean-square value. Therefore, harmonics up to 19 th harmonic are accurately detected at 50 Hz to prevent any malfunction from occurring due to harmonics.
|
|
|
Motor protection switch with higher switching capacity and up-to-date supplements. Fifteen adjustable ranges cover current area from 0.1 to 32 A. Due to high switching capacity, the additional protection from short circuits is required rarely.
|
|
Enclosed DOL starters, safety switch disconnectors, thermal-magnetic motor circuit breakers
Description
TeSys wall-mounted DOL starters LG, LJ
Enclosed DOL starters are used to control starting or stopping of the machine
TeSys motor-starter solutions incorporate 2 auxiliary contacts which allow them to be integrated in safety wiring diagrams
TeSys Vario switch disconnectors
Installed on an enclosure or in a cabinet, these rotary control switch disconnectors act as circuit load breakers
Available in open or enclosed version
Fixed on the front panel or DIN rail mounted
Padlockable versions
Thermal-magnetic motor circuit breakers TeSys GV2-ME
|
|
Modular circuit-breakers for the protection of motor supply circuits
Description
Rating current:4 to 80 A
Breaking capacities:50kA under 380/415 V
Tripping curves:MA (short -circuit protection to combine with suitable overload protection)
Compliance with standards: IEC 60947-2, certified by national official authorities; NG125LMA + Telemecanique contactor and thermal relay combination in compliance with IEC 60947-4
Suitable for isolation in accordance with industrial standards:IEC 60947
Operating voltage:up to 500 Vac, insulation voltage:690V
Optional add-on earth leakage modules:Vigi NG125
Optional auxiliaries:indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
|
|
Power Break II Insulated Case Circuit Breakers are highly compact, heavy-duty breakers that combine ease of use, asethetics and state-of-art performances in 200 through 4000-Amp frame sizes, rated for up to 200,000 Amps RMS symmetrical for 240Vac, in drawout and stationary versions.
Now available with the new EntelliGuard® TU Trip Unit which provides excellent selectivity and arc flash energy protection.
Features and Benefits
* Compact, Lightweight design
* Modular, drop-in accessories common to all frame sizes
* Flush-Mounted pump handle
* Manually and electrically operated versions in same compact envelope
* Double Insulated ON/OFF buttons
* 72-point pre-wired , dedicated secondary terminals
* Modular, field-installable motor operator
* EntelliGuard TU Trip Unit featuring Reduced Energy Let-Through (RELT) setting
* Modular auxiliary switches with up to 12 NO/NC set of contacts
* Charge-after-close mechanism
* Manual discharge of springs without closing
* Suitable for reverse feed™
|
|
|
|
|
|
High Performance Circuit Breakers:
410
Thermal-magnetic circuit breakers,
various mounting methods, toggle operated
412
Thermal circuit breaker with threadneck
mounting and push-pull actuation
413
Thermal circuit breaker with threadneck
mounting and push-pull actuation
428
Thermal-magnetic circuit breaker,
plug-in type, with manual release button
437
Thermal-magnetic circuit breaker
with remote trip coil, toggle operated
446/447/449
Thermal-magnetic circuit breaker, base
mounting, special dual button manual release
452
Thermal-magnetic circuit breaker with
threadneck mounting and push-pull actuation
482
Thermal circuit breaker with threadneck
mounting and push-pull operation
483
Thermal aircraft style circuit breaker,
temperature-compensated and explosion-proof
4120
Thermal circuit breaker with threadneck mounting, temperature-compensated and explosion-proof
4140
Thermal circuit breaker with threadneck mounting, single pole, robust design
4930
Remote control circuit breaker, single pole, temperature-compensated
5140
Thermal circuit breaker with threadneck
mounting, three-pole, robust design
520/530
Thermal-magnetic circuit breaker with toggle actuaction, double pole (520) or three-pole (530)
583
Thermal circuit breaker with threadneck mounting, temperature-compensated and explosion-proof
|
|
Residual current circuit breakers EFI are used for protection against indirect touching of parts under voltage, for
prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation
and for protection against direct contacts of parts under voltage in case of I < 30mA. Residual current circuit breakers
can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective
conductor are separated (VDE 0100 Teil 410).
Types - Our programme comprises residual current circuit breakers which are sensitive to alternating residual current
(AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).
|
|
|
With a residual current circuit breaker (RCCB) the following protective measures are available: fault protection, protection against fire and additional protection in case of direct contact.
|
|
The PolyZen device is a thermally protected, precision Zener diode that helps protect circuits from overvoltage & overcurrent fault conditions.
|
|
Actuator Style = Push to Reset
Button Color = Black
Termination Type = 6.35 [.250] Straight Quick Connect Tab
Current Rating (Amps.) = 10
Operating Voltage, Max. = 32 VDC, 250 VAC
Number of Poles = 1
Trip Time at 200% = 2.2 to 15 Seconds
Interrupt Capacity = 1,000 A @ 32 VDC or 250 VAC
Mounting Options = Snap-In Panel Mount
Approved Standards = UL Recognized, SEV Approved, VDE Approved, Demko Approved, CSA Certified
|
|
104
Thermal circuit breaker, integral type, single pole
104-PR
Thermal circuit breaker for pcb mounting, single pole
105
Thermal circuit breaker for snap-in mounting, single pole
106
Thermal circuit breaker for threadneck panel mounting, single pole
127
Thermal circuit breaker with manual release button, plug-in or snap in panel mounting
129-L11-H-KF
Thermal automotive circuit breaker with manual release, for base mounting
157/158
Thermal single pole circuit breaker, threadneck panel mounting or integral type
1110
Push-push thermal switch/circuit breaker combination, single pole
1140-E
Single pole thermal circuit breaker, integral type
1140-F
Thermal circuit breaker for snap-in panel mounting, single pole
|
|
Application Flexility
In Switchboards , motor control centers and lighting and in power panelboards. General Electric molded case Circuit breakers are being used to provide reliable circuit protection. Molded case circuit breakers in individual enclosures are also being used in numerous applications
Minimum Downtime
Downtime is reduced and fuse replacement is eliminated with circuit breakers. In case of overload or short circuit, the breaker trips, opening the circuit and protecting the conductors. When normal conditions are restored, the breaker can be closed("ON") again.
Features and Benefits
* Molded Case
* Thermal Magnetic Trip
* Proven Reliability
* Provide Cost effective Solutions
* Multiple types to fit in your application
|
|
|
Loadline Y-Frame MCCBs span a range of current ratings from 20A to 1600A in just 6 modular frame sizes. All electronic Y Frame devices comply with IEC 947-2 selectivity utilisation category B, and all frame sizes are complete with a full range of accessories including shunt trips, under voltage releases, auxiliary contacts, pre-trip alarm contacts, earth fault protection, motor operators, terminal covers, rotary handles and plug-in capability. The advanced technologies employed within the range ensure problems caused by harmonics, DC applications, temperature rise and discrimination / selectivity issues can be easily overcome by simple selection of the appropriate device.
|
|
|
|
|
|
201
Thermal-magnetic circuit breaker for rail mounting, low resistance option
2210-S2
Thermal-magnetic circuit breaker, socket or panel mounting, single or multipole
2210-S291
Thermal-magnetic circuit breaker, single pole, with auxiliary contacts
2210-T2
Thermal-magnetic circuit breaker for rail mounting, single or multipole
2215-L
Thermal-magnetic circuit breaker, small width, pcb or threadneck panel mounting
2215-G
Thermal-magnetic circuit breaker, small width, threadneck mounting
2215-F1
Double pole thermal-magnetic circuit breaker, pcb or flange mounting
3120-...-M...
Rocker actuated thermal-magnetic circuit breaker, snap-in mounting
3120-...-M...
Push button operated thermal-magnetic circuit breaker, snap-in mounting
3120-F7..-M...
Rocker-actuated thermal magnetic circuit breaker, snap-in mounting, new design
3200
Plug-in type thermal-magnetic circuit breaker with manual release facility
3300 fast acting
3400 standard delay
Thermal-magnetic circuit breaker with auxiliary contact option, threadneck mounting
3500 standard version
4000 low resistance version
Thermal-magnetic circuit breaker with manual release facility, flange mounting
3600 standard version
3900 low-resistance verson
Thermal-magnetic circuit breaker with auxiliary contacts, socket mounting
|
|
Indoor medium voltage switches
Vacuum circuit-breaker type V...
according to IEC 62271-100 + A1
• Rated voltage 12 kV, 24 kV, 36 kV and 38.5 kV
• Rated current 630 A, 1250 A, 1600 A and 2000 A
|
|
Power/Vac® Vacuum Breakers
1200 to 4000A. GE pioneered this interrupter technology beginning with experimental work in the 1920's. Today, the vacuum design remains superior to other arc interruption technologies by providing a smaller footprint and simpler design.
Power/Vac® Replacement Vacuum Breakers
1200 to 3000A. GE Power/Vac® Vertical Lift (VL) breakers provide an economical and efficient way for customers to upgrade existing GE Magne-Blast Type AM (Air Magnetic) vertical lift circuit breakers.
Power/Vac® Vacuum Distribution Breakers
200 to 1120A. GE's outdoor distribution breaker uses the same proven vacuum interrupter technology as found in GE's Power/Vac breaker installed in metalclad, medium voltage switchgear.
Power/Vac® Vacuum Distribution Recloser Breakers
200 to 1120A. The GE Distribution Recloser helps customers maximize uptime and minimize outages by clearing non-persistent or temporary overhead faults.
|
|
- For use on closed vessels and piping systems to
control induced vacuum within safe limits
- Adjustable from 1/4" - 20" (8-508mm) Hg vacuum - factory
set at 2" (51mm) Hg vacuum
- 3/4" NPT straight shank
- Maximum operating temperature 366°F(186°C)
- Maximum operating pressure 150 psig (10.3 bar)
|
|
|
|
|
|
1. General
1) High reliability of the operating mechanism
- Separate design of the main circuit from the operating mechanism.
- Adopt the toggle link method.
- Improved the reliability of electric circuit.
- Adopt the rapid auto-reclosing method as a standard option. (O-0.3sec.-CO-3min.-CO)
2) High interrupting performance
- Make short of the interrupting time. (3cycles)
- Increase the rated short-circuit withstand characteristics. (1sec. to 3sec.)
3) Great operational safety
- Reinforce the insulation in the conduct, by adopting the molded housing in each phase.
- Built in the device making the contacts open first when draw in and out.
- Adopt the tulip-shape connection between the cradle and the VCB.
2. Type: LVB
3. Ratings
- Rated voltage: 7.2kV, 12kV, 17.5kV, 24kV
- Rated normal current: 630A, 1250A, 2000A, 2500A
- Rated short-time withstand current: Max. 40kA
4. Wide range of accessories (optional)
5. Applied standard: IEC 62271-100 (M2, E2(List1), C2 class)
6. Certification: KEMA, KERI
|
|
Decription:
Barrier terminal block.
Ratings:
Volts:
- 600V
Amps:
- 115A
Agency Information:
CE, UL E62622; CSA LR15364.
Marking:
Marking strip optional, consult factory.
Note:
*Consult factory for torque ratings for CP and Q options.
Poles:
2- to 6-poles.
Wire Range:
#2 n #14 CU/#8 AL.
Torque Rating*:
2-3, 50 in-lb; 4-6, 45 in.-lb; 8, 40 in.-lb; 10-14, 35 in-lb.
Options For Load Side Connector:
CP: Sems pressure plate, rated 60A, 600V
Q: Quick-Connect, rated 50A, 600V
To order options, enter letter code in front of Catalog Number
|
|
|
Yaskawa SF6 gas rotary-arc circuit breakers are rated for applications in power generating plants, substations, and industrial plants at 3.6kV to 15kV. Yaskawa SF6 gas rotary-arc circuit breakers are safer to operate than vacuum and other competitive types because a two-stage pressure switch in each of the interrupters continuously monitors the gas pressure. This series of Yaskawa SF6 gas rotary-arc circuit breakers offer excellent interrupting characteristics, comparable to air-magnetic breakers, with continuous current ranging from 600 to 3000 amps. In addition, the surgeless nature of the current interruption eliminates the need for surge arrestors to dampen voltage spikes related to current chopping and switching surges. This feature makes the Yaskawa SF6 gas rotary-arc circuit breakers ideal for the protection of motors, capacitors, and transformers. This series of circuit breakers conforms to applicable ANSI, IEC and JEC st
|
|
Circuit Breaker and Transient Voltage Surge Suppressor
The Siemens circuit breaker and transient voltage surge suppressor is comprised of a highly effective TVSS module integrated with (2) 1-pole circuit breakers. This device incorporates the robust features of our secondary circuit breaker surge arrester with a lower clamping voltage ratings.
Two red LED indicator lights are provided to show that surge protection is provided for all circuits connected to the panelboard. As a Siemens exclusive feature, the device notifies the owner of loss of surge protection by tripping one or both of the circuit breakers. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided.
|
|
- No minimum order quantities
- Same day shipment on in-stock products
|
|
|
|
|
|
Maximum safety and continuity of the electric power supply
REC2 is a self-reclosing system that uses consecutive time sequences, with an additional insulation control capacity, so that it does not reclose the unit until the problem has been solved. Therefore, it maintains the highest continuity of the electrical service under the maximum safety levels, with the minimum number of reclosures needed when the electrical installation requires so. Years of experience in these applications leads us to:
- A safe earth leakage protection unit.
- Maximum self-reclosing guarantees.
- More compact and modular.
The new REC2 can act in two ways, according to prior selection:
- Self-reclosing, by time (various reclosure attempts in a time sequence)
- A second option is that once the earth leakage system has tripped, the unit checks if there is a leak, measuring the insulation of the installation before the self-reclosing process is carried out.
The system guarantees the maximum continuity of the electric power supply in homes, shops, industries, etc. while it guarantees the protection against any form of earth leakage.
|
|
Transformer differential protection systems: DQ2S 2, DQ3S 2
Devices DQ2S2 and DQ3S2 are complex protectors for use with transformers- and motors.
Their main purpose is to stabilize differential protection. Two base models are available:
- DQ2S 2 for two-winding transformers
- DQ3S2 for three-winding transformers
|
|
Load break switch: switchblade with integral arc-strangler load breaking device for hinge-style mounting. This product includes a stationary core and a spring-loaded sliding sleeve which could quickly cut off the arc produced between the mounting contact and blade during load breaking operation.
Rated voltage: up to 15.5kV
Rated continuous current: up to 200A
|
|
Residual current circuit breakers up to 125A
Description
Nominal current:1 to 125 A
30mA sensitivity:additional protection against direct contact (in accordance with IEC 364)
100, 300, 500 mA sensitivities:additional protection against fire and indirect contact (in accordance with IEC 364)
B type:protection of installations with three-phase rectifier
Type "si": protection of sensitive circuits (computing equipment) and those prone to disturbances (ballast lighting, power electronics)
Selective version :tripping of the device the closest to the fault
Compliance with standards:IEC EN 61008 certified by national official authorities
Suitable for isolation in accordance with industrial standards: IEC 60947
Operating voltage:up to 440Vac, insulation voltage: 500V
Optional auxiliaries:indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
|
|
Typical Applications
Warn of trouble by providing an alarm output if a process signal exceeds a high or low limit.
Create an independent emergency shut-down system to avert undesirable situations in the event of central power failure or DCS shutdown.
Combination alarm trip and transmitter modules reduce costs when both alarming and monitoring functions are needed at the same location.
Sense dangerous conditions, and shut down equipment, before it is damaged.
Compare two variables and trip an alarm when the difference between the two exceeds a preset value.
Install multi-trip alarms to provide several levels of warning and shutdown actions.
Use for reliable, and cost-effective, on/off control of pumps and motors.
|
|
|
GE's BreakMasterTM metal enclosed load interrupter switches provide dependable, economical load switching and protection for medium voltage circuit applications from 2.4kV through 15kV in 600 or 1200 ampere load interrupting ratings. Used mainly as a primary or secondary disconnect switch for transformers, the variety of configurations in which BreakMaster is available also make it useful for specific distribution needs. It can be inserted as a main or feeder switch in PowerVac switchgear or LimitAmp motor controller lineups. Fault current protection is available using a complete line of current limiting or expulsion fuses.
|
|
|
Ensto's family of load break switches consists of 3-pole switches with additional poles and accessories: handles, shafts, auxiliary contacts and terminal covers.
|
|
|
In application of new concept mechanism of bendable type blade structure LG Tri-MEC Air Insulited Load Break Switch (LBS) has been equipped with further advanced technology and in a system switching the circuits when checking, measuring, testing and repairing the instruments. at branch point with 3 phase load break switch designed customer-orientedly and considerably. In particular, a bendable type blade structure is significantly small in operation radius in contrast with existing direct line one and an arc discharge angle at the time of breaking operation is under 50°, thereby reducing the danger of accident by an arc remarkably. And it is suitable for a metal Enclosed, Pad-Mounted Switchgear and Package Substation thanks to higher insulation-resistant power and is equipped with durability, stability and economical efficiency. E2 class mechanical strength based on new standard application.
|
|
|
|