- Hydraulics - Pneumatics >
- Filter and Separator >
- Compact drain
Compact drains
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Operating pressure: 10 bar - 250 bar
... operation and minimal maintenance without having to remove from the line • Compact and light weight, reducing installation costs • Hardened disc and seat for long life • One trap covers a wide range ...
Spirax Sarco
Operating pressure: 0 bar - 16 bar
... done by the drain valves. In ordinary drains, there is always loss of compressed air. Most of the condensate drains hâve a 4 mm orifice. This 4 mm orifice bleeds about 34 cfm, which is ...
Operating pressure: 1 bar - 13 bar
Discharge capacity: 0 kg/h - 167 kg/h
Operating temperature: 2 °C - 65 °C
Automatic mechanical condensate drain AOK 13PA has been developed for fully automatic discharging of condensate or any other non-aggressive fluid from compressed air system. The unit can be installed as external drain ...
Operating pressure: 0 bar - 16 bar
Operating temperature: 1 °C - 50 °C
... very compact solution with unique installation flexibility and reliability. Typical application is in refrigeration dryers and filters due to its compact size and light weight of less than 500 grams. ...
Operating pressure: 63, 40 bar
Operating temperature: 400, 300, 450 °C
... close immediately. The traps in the DK series are correspondingly simple in structure, feature a small, compact body and are low in cost. USE Compact steam trap for ...
GESTRA AG
Operating pressure: 0 bar - 16 bar
Operating temperature: 1 °C - 50 °C
Electronic zero air loss drain The KAPTIV-CS (Compact Solution) removes all types of condensate from compressed air systems up to 100 m³/min. without the loss of compressed air. The KAPTIV-CS is cost ...
Jorc Industrial
... 1 weighs 3.5 kg, and even the heaviest DRT-6 only 53 kg. The ultra light and compact design makes the terminator easy to install. ・All that needs to be done is to take a small amount of processed water ...
Operating pressure: 50, 16 bar
Operating temperature: 2 °C - 50 °C
... electronic timer. The drains are compact and can be installed on all compressed air system components like compressors, aftercoolers, dryers, filters and pressure vessels, regardless of their size ...
Parker Gas Separation and Filtration Division EMEA
Operating pressure: 1, 3, 2 MPa
Discharge capacity: 450 kg/h - 25,000 kg/h
Operating temperature: 350, 220, 240 °C
Free Float® Steam Traps for Process Use JX series steam traps can be installed on various types of equipment that uses steam as a heat source. The series covers a wide range of condensate loads, from ...
TLV Euro Engineering
... Electromechanical drainer E220: known for its small size, high draining capability, timer regulating start-and-stop, a test button and working alarms. Electric drainer LD: equipped with a mechanical tank, allows ...
Operating pressure: 17 bar
Operating temperature: 232 °C
... efficiency and long-lasting reliability. Add the advantages of valves integrated into one compact trap/valve casting, and you extend the benefits into installation, trap testing and maintenance. All ...
Armstrong International, Inc.
Acid condensate neutralizer for boilers up to 35Kw, transparent bowl, supplied with 20mm connection fittings, wall fixing kit, 2 calcium carbonate refills Available size: 3/4' x 20mm
... Series electric timed drain is effective over a wide range of applications because its dual timer allows the user to accurately set the correct drain cycle. Its compact size and light ...
Operating pressure: 1 bar - 16 bar
The proven, level-controlled UFM condensate drain stands for reliable and fully automated condensate drainage without pressure losses. This is made possible by a capacitive sensor that permanently detects ...
Operating pressure: 0 bar - 300 bar
Operating temperature: -20 °C - 70 °C
... operating safety of the entire ar- mature. The purge block is characterized by a compact design and the purge valves installed lateral over the cylinders shoulders. It has a small dead volume and by ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining