The Epson fieldbus systems are the ideal connection of an Epson robot with an industrial fieldbus system. No matter if Devicenet or Profibus, the connection of fieldbusses to an Epson controller is completely integrated into the Epson developer surface Epson RC+.
So it is possible to use the high performant fieldbusses.
|
|
3U VME Boards
Complete line of 3U VME chassis & CPU boards along with a diverse line of plug in boards such as industrial I/O and communications, PCMCIA, VME ModPack & PMC carriers, ModPack and fieldbus.
For chassis, please follow the link systems. |
|
* PMC100TX - 10/100BaseTX Ethernet Module :
The PMC 100TX is a high performance ethernet controller PMC module providing connection to a 10baseT or 100BaseTX network. It uses the PCnet-Fast+ and NetPHY-1 chipset from AMD. Connection to the network is via a low profile RJ45 style connector on the PMC front panel. Comprehensive software support is available for Windows 9x , NT, 2000 and VxWorks.
* PMC100FX - 100BaseFX Fibre Ethernet Controller :
The PMC 100Fx is a PMC Module providing a high performance ethernet controller for connection to a fibre network. It is available in two forms, multi-mode which has a range of up to 5 Kilometers or single mode which is capable of driving distances up to 46Km with suitable fibre. It uses the PCnet-Fast and NetPHY-1 chipset from AMD and connects to the fibre via an SC connector on the PMC front panel. ST connectors are available to special order. This connector is angled at 34° to the module ensuring minimum bending of the attached fibre. |
|
SYSTEM-90E provides interface modules to both InterBus and Profibus-DP standard fieldbusses. Decentral installations using equipment of various manufacturers may thus be implemented in a sophisticated yet cost effective way.
All modules comply with the respective standards, ensuring reliable plug-and-play when building and implementing fieldbus architectures.
Fieldbusses
Profibus slave: PBS-1
InterBus slave: IBS-3
InterBus master: IMA-1 |
|
| ... products without technical information |
| |
deltadue® series acquisition modules with fieldbus for DIN rail mounting
A complete range of compact and flexible modules open to the external world
deltadue® acquisition instruments series is composed by single and double channel analog modules and by 6 inputs and 2 outputs digital modules.
|
|
The ISbus fieldbus system product series includes components and systems for use on Profibus PA and FOUNDATION fieldbus H1
Installation in Zone 1, Zone 2, Zone 21, Zone 22 and Division 2
Different field device couplers to connect intrinsically safe and non-intrinsically safe fieldbus
Integration of simple, binary signals in the fieldbus via intelligent digital I/O couplers
Redundant fieldbus power supply with galvanic isolation of fieldbus segments for FOUNDATION fieldbus H1
Field housings of different sizes and materials, such as plastic, stainless steel and aluminium
System solutions for field installations and integrated solutions in combination with remote I/O |
|
| Foundation Fieldbus H1 level has been designed as a digital replacement of the 4 to 20mA standard in the process industries. Foundation Fieldbus is also a LAN (Local Area Network) for instruments used in both process and manufacturing automation with built-in capability to distribute the control application across the network. The physical wiring is also fully compatible with intrinsic safety (IS) or nonincendive wiring standards and may be used in hazardous, as well as general purpose areas. In hazardous areas standard explosion-proofing or power limited concepts may be used, as well as IS concepts, offering greater cabling design flexibility. |
|
| The DeviceNet protocol dramatically reduces costs by integrating up to 62 devices on a 4-wire trunk network. Communications data is carried over two wires with a second pair of wires carrying power. Discrete and analog devices may be connected into the DeviceNet protocol. |
|
| AS-Interface networks up to 62 field devices onto a single pair of wires that delivers both signal and power. Actuator Sensor Interface, or AS-Interface, was developed by a group of sensor manufacturers and introduced into the market in 1994. Since that time, it has become the de facto standard for discrete sensors in process industries throughout the world. AS-Interface may be used in hazardous process environments using explosion proof, tray cable, nonincendive and for nonincendive wiring protection concepts. |
|
| ... products without technical information |
| |
| ... products without technical information |
| |
| Valves specifically designed to enable users to comply with particular industrial safety requirements and safe working practices. |
|
| ASi fieldbussystem suitably for small, distributes clusters of PLC combination PLC, entrance/output interface and distribution block integrated by actuators and sensors field bus ii-system modular system for up to 64 Stationenn |
|
deltadue® series control modules with fieldbus for DIN rail mounting
A complete range of compact and flexible modules open to the external world
ASCON's process control experience and the increasing need for integration of the control systems have brought to the development of the deltadue® series temperature and control modules, single and dual loop.
|
|
| The Prism Series, designed for corrosive process environments, attaches directly to Sanitary Diaphragm and Angle Valves. This rugged, feature-rich platform, offers a full array of communication and switching options as well as discrete integral pneumatic control for single-acting valve actuator operation. |
|
| The Quartz explosion/flame proof design is FM/CSA approved and ATEX certified for use in hazardous environments. And with the epoxy coated anodized aluminum enclosure it may be used in corrosive heavy wash down areas as well. |
|
| The Axiom is a discrete valve communication & control device for quarter-turn automated valves. The advanced position sensor offers reliable long-life performance with push-button settings that may be made quickly and conveniently. The integral pneumatic pilot valve offers contemporary features which further enhance the operating performance of your automated valve system. And, with the Axiom's rugged construction will withstand your most challenging plant environments. |
|
| ... products without technical information |
| |
ACCELENS Inclinometers
Inclinometer based on a MEMS acceleration sensor
CANopen Interface
Measuring Range +/-80° and 360° Degrees
Horizontal and vertical mounting
Up to three measuring axis
Rugged Aluminum Housing
BCD Switches for Adjusting Baudrate and Node Number
Switchable Terminal Resistor
|
|
Features:
CA 306 and PB 306: Simple preset units with front thumbwheel switches, for easy remote setting of single parameters (i.e. setspeed of a drive) via fieldbus. By pressing the ENTER button, the actual BCD setting will be transmitted to the selected register of the target unit as PDO or SDO (CANBUS) or hold in the polling register for readout (PROFIBUS)
Front dimensions 96x48 mm
CA 340 and PB 340: Simple indicators unit for remote display of all register data which are available on the network. The use of this display can provide operator information about any of actual process data or parameter settings, at any place around the machine. The CAN version is able to handle PDO objects as well as SDO objects.
Front dimensions 96x48 mm
Bright 6 decade LED display with 15 mm size
CA 541 and PB 541: This unit combines both, preset switch and indicator. Whilst the BCD switch allows to make register changes via fieldbus, the LED display provides information about the actual setting of the same or any other register.
Front dimensions 96x72 mm
Bright 6 decade LED display with 15 mm size |
|
CAN bus
External switch
External switch MAX
Node
Termination
Profibus
External switch
External switch MAX
Node
Termination
Profibus Ex i: External switch
SafetyBUS p: Preferred types are generally available from stock |
|
|
|