Dimensions acc. to IEC 60297 or IEEE 1101.1, Aluminum or sheet steel versions, up to superior EMC level. Large selection of assembly options.
|
|
Elma offers AC and DC horizontal enclosures in 2U and 5U heights and a DC-only version in 4U height. They include a wide range of backplane, shelf management,and other options. Pluggable and redundant fan trays, PEMs and shelf managers provide the highest level of availability (99.999%). The units have been optimized via backplane signal integrity studies and chassis thermal simulation.
The 2nd Gen 19" rackmount vertical ATCA chassis is designed for carrier-grade applications. The 13U chassis features a 14 -slot Dual Star or Mesh backplane. The unit is fully pluggable, designed for NEBS compliance, and radial or bussed IPMB shelf management. The chassis has been optimized via thermal simulation studies.
|
|
|
MicroTCA is complementary to PICMG3.0 ATCA. Where AdvancedTCA is optimized for very high capacity and high performance applications, MicroTCA is designed to address cost sensitive and physically smaller applications with lower capacity, performance, and perhaps less stringent availability requirements. MicroTCA preserves many of the important philosophies of AdvancedTCA, including basic interconnect topologies and management structure.
|
|
- 4U 19'' Rackmount Industrial Chassis for IPC or Mainboard :
- Rugged design constructed in 1.2mm Heavy duty steel and
it's a cost effective solution
- One 12cm lntake cooling for excellent cooling cycle and
comes with washable air filter
- Design for various industrial computer for networking,
communication applications and related solutions
|
|
one cabling solution for your equipment
- Ten sizes of cable ducting plus associated accessories.
- Optimal ducting sizes for maximum cabling capacity.
- Simplified installation:
- snap-off tongues for cable entry,
- 4 types of fixing accessories to suit the application: screw, clip-in, door mounting and chassis mounting.
- Important: no metal component parts enter the inside of the trunking, thus maintaining electrical insulation.
|
|
| ... products without technical information |
| |
Data and energy
Unrivalled worldwide, eks Engel presents a new Hybrid Splice Box inside the FIMP product line that makes it possible to combine data and energy.
Furthermore, a new version with a SC-RJ coupling which allows combining multimode, singlemode and POF in one plug will be presented. The front panel of the Hybrid Splice Box can be outfitted with up to four RJ45 Click&Snap-, or alternatively with two Smart Hole-Modules.
|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
This new concept of modular power connection allows a variety of applications, specifically adaptable to all users.
The wide range of current ratings available (40 to 1000 A) as well as the different levels of watertightness and shielding possibilities, offer connector solutions to numerous applications such as traction motors, converters, transformers, intercar power lines ...
|
|
G12 - 12 Module Solution
Easy Glide Docking
* Provides an easy way of guiding a fixture into position prior to engagement
* Runners along the platform provide a smooth-sliding action
* Ideal feature when using large scale fixtures
Tabletop Configuration
* The tabletop configuration allows the S6 and G12 to be mounted to any horizontal surface
* Rear covers are available to protect wiring from the receiver to the test equipment
QuadraTrack™ Engagement
* Engaging Mechanism in the form of a pair of slotted steel slides located in the Receiver
* Distributes uniform pressure to four points on the ITA during engagement and disengagement
* Precise signal integrity between the Receiver and ITA is maintained by QuadraTrack™ engagement system
Slide Configuration
* The Slide Kits for the S6 and G12 allow access to test instrumentation and wiring
* Multiple Accessories are available for this configuration such as the Cable Tray and the Keyboard Tray Kit
|
|
|
|
|
|
FULLTEST4058 model was designed from HT ITALIA to performing essential tests in industrial environments on electrical machines devices and partially type-tested assemblies (PTTA) in compliance with EN60204-1 and EN60439-1 respectively.
The meter principally performing Continuity test on potential equalising conductors with >10AAC test current, Insulation Resistance with 500VDC test voltage and Withstanding tests with 1000AC test voltage (for electrical machine devices) and 2500V test voltage (for individual test on PTTA assemblies switchboards).
Withstanding test is performed also in BURN mode with no limits on trip-out current. Discharging Time measures of internal capacitance and on external plugs of device under test complete the list of possible test with this meter.As FULLTEST4050 more advanced model also FULLTEST4058 have a built-in internal memory to save all measurement results and a RS-232 PCs interface for directly transfer of saved tests by dedicated Windows software.
The model is fitted inside a practical and protected plastic case board with no flammability and a membrane keyboard for rapid selection of functions is included on the frontal panel together a wide custom display.
FULLTEST4058 is the ideal solution for any kind of verifier and/or industrial installer to performing easily and rapid test on industrial appliances.
|
|
| ... products without technical information |
| |
|
|
|
|
CitectFacilities integrates all your facilities systems, including HVAC, lighting, fire, CCTV and access control, across your entire enterprise to deliver a single facilities monitoring and control solution. The software can connect to hardware devices supplied from multiple vendors, in single or multiple sites.
What does this mean for you?
A single, central view of all facilities systems is essential for property owners and facilities managers:
PROPERTY OWNERS
CitectFacilities provides strategic information that lets property owners reduce facility operating costs and improve tenant service. Existing and future facilities equipment investments are protected and the high scalability provides a low risk, low entry cost option that lets you expand your facilities application according to your business plan.
FACILITY MANAGERS
Facility Managers gain real-time visibility of all facilities systems, including central alarm management, with CitectFacilities. This raises staff productivity and improves responsiveness to tenants. Open protocols and open architecture gives you the flexibility to integrate building automation technology suited to your facility.
|
|
Heaters
Compact heaters to keeping at a moderate temperature of cabinets and housings with electrical electronic installations.
In switchgear cabinets condensation with variations in temperature, which can lead to malfunctions or to losses of the components in the switchgear cabinet, forms. Heaters prevent subnormal temperatures and work against the emergence of condensation. Heater blowers provide additionally for the even distribution of warm interior air. The heaters are appropriate for continuous operation.
|
|
Heaters for the thermo-regulation of enclosures, for application on DIN rail, and available in three version:
- with bipolar (15-30W) or three-pole (45-150W) power cable
- with three-pole terminal block (45-150W)
- ventilated (250-400W)
|
|
|
Condensation poses a particular risk for control electronics, especially with outdoor siting, but also indoors. Various different output categories ensure that the correct thermal output is always available. In this way, the total required thermal output can be distributed with complete accuracy within an enclosure.
|
|
-Pressure clamp connectors
-Dynamic heating up
-Wide voltage range
-Temperature limiting
-Energy saving
-Clip fixing
-Quick installation
These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature may not fall below a minimum value.
The aluminium profile heater body design has a chimney effect and distributes the heat evenly.
The pressure clamp connectors save time and simplify installation.
|
|
Low surface temperature
Quick mounting due to clip fixing
Double insulated (plastic)
Wide voltage range
Small size
Compact heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air.
The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design.
Our complete range of thermostats and hygrostats can directly be connected to the heater CS 060.
This heater is also available in a version with plug-in thermostat requiring no additional wiring (CSF 060).
Both versions are designed for permanent operation.
|
|
Units for DIN or screw mounting.
TH heaters, installed separately from cooling unit, must be connected to a TMC thermostat. When used to prevent cabinet condensate they should be electrically connected also when cabinet is off.In this cabinet it’s better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution.
|
|
Technical details
- Protection class I (ground wire) - protection type IP 54 (DK = IP 20)
- Temperature setting:
ON 25 °C - OFF 55 °C (operating temperature of heating
system itself)*
Tropical version possible: ON 35 °C - OFF 65 °C
-> Other settings upon request
- 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
- > Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm²
- Mounting position: vertical
- 2 fastening alternatives (optional)
Snap fitting for 35 mm DIN rail (figure 1)*
Screw fastening (figure 2)
|
|
PTC units for DIN bar application.
EH/FH heaters, installed separately from cooling unit, must be connected to TMC thermostat. When used to prevent cabinet condensate they should be eletrically connected also when cabinet is off.In this cabinet it’s better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution.
|
|
Technical details
• Protection class II (double insulated)
- protection type IP 54 (DK = IP 20)
• Temperature behavior:
· Self control, in variation of ambient temperature
· Dynamic heating-up
• Auxiliary fan attachable for improved air distribution
–> Auxiliary fan
• 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 2 x 0.75 mm² Silikon
–> Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm²
• Mounting position: vertical
• 3 Fastening alternatives (optional)
|
|
Technical Details
• Protection class I (ground wire) - protection type IP 65
• Temperature setting:
ON 25 °C - OFF 55 °C (operating temperature of
heating system itself)
Tropical version possible: ON 35 °C - OFF 65 °C
–> Other settings upon request
• Connection
Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
–> Other lengths upon request
• Mounting position: vertical
• Fastening
|
|
Product group P3
Pivoting frame for directed ventilation
Electric data:
• Protection class I (ground wire)
• Protection type IP 20
• Connecting leads 0,5m 3x0,75 mm² PVC
Other lengths upon request
Utilizing a circulation fan avoids head accumulation and formation of heat pockets inside control cabinets. When heaters are installed, their efficiency is increased by circulation fans. The resulting air circulation dissipates heat through the surface of the cabinet and so, a cooling effect is achieved.
|
|
... see all the products in the category
Axial fans
|
|
|