clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.
With the bright color power meter display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.
Applications
Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
Load studies - Verify electrical system capacity before adding loads
|
|
296: 4,000 count manual ranging digital clamp-on meter with analog bar graph, True RMS, frequency, % harmonic distortion, data hold, Min/Max/Peak, and sleep mode/auto off.
293: 4,000 count manual ranging digital clamp-on meter with analog bar graph, True RMS, frequency, trim mode, data hold, peak hold, and sleep mode/auto off.
291: 4,000 count manual ranging digital clamp-on meter with data hold, and peak hold
275: 11,000 count autoranging digital clamp-on meter with True RMS, frequency, capacitance, temperature, non-contact voltage detection, data hold, relative mode, Min/Max/Peak, peak hold, sleep mode/auto off, 0.5% Basic DC accuracy
270: 4,000 count autoranging digital clamp-on meter with analog bar graph, frequency, capacitance, temperature, non-contact voltage detection, data hold, relative mode, Min/ Max/Peak, peak hold, sleep mode/auto off
265: 4,000 count autoranging digital clamp-on meter with frequency, capacitance, data hold, and sleep mode/auto off
250: 4,000 count manual ranging digital clamp-on meter with data hold, and peak hold |
|
Description:
True RMS for accurate measurement when harmonics are present.
- Extra-high-capacity 2000A measurement.
- Measures True Power, Apparent Power, Reactive Power, Power Factor, voltage, current, and frequency.
- Calculates total power and power factor on 3-phase, 3-wire, and 3-phase, 4-wire, and 1-phase, 3-wire circuits using stored measurement.
- Stores up to 4 sets of measurements for calculation on multi-phase and multi-wire circuits.
- Large, easy-to-read, dual 4-digit, 4000-count LCD display for high resolution.
- Instantly recall the calculated Power Factor.
- Accessories included: (1) 9V battery, test leads, carrying case. |
|
| Amp-Clamp current probes, used with analog VOMS provide accurate measurements of high AC current found in power systems and related control circuitry. The Amp-Clamp jaws are closed over a conductor in the circuit and the current load is indicated on the connected meter. The 150-2 has six ranges (up to 300 ACA) and is available with banana and reverse banana plugs. |
|
| ... products without technical information |
| |
|
|