Current transformers

Do you need help making a decision?  Take a look at our buying guide
115 companies | 496 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
Search
Current transformers | Choosing the right transformer
There are 5 main types of transformers. The differences between each transformer are related to the types of applications possible. Current transformers: these are transformers in which the secondary current is proportional to the primary current. They can be used with all low-frequency alternating currents. Power transformers: these are distribution transformers with a voltage of one phase higher than 1,000V. They are used to transport electricity over...
current transformer
current transformer
DCDC414-002

Electric power: 3,000 W
Primary voltage: 420 V - 850 V
Secondary voltage: 14 V

Features •ZVS Phase-Shift Full-bridge 3kW transformer •Work with ZVS inductor 14µH / 14Apk •Recommended output inductor 1µH / 180Adc •Switching frequency 100kHz •UL94 and RoHS materials (F/155°C) •Design based ...

See the other products
PREMO
instrument transformer
instrument transformer
TT35A series

Primary current: 5 A - 450 A

Current transformer with built-in transducers ø 35mm Primary current field-selectable 9 programmable ranges Output 0..,20mA - 4..,20mA - 0...10V d.c. 4-wire technology, a.c. auxiliary supply

See the other products
IME Spa
instrument transformer
instrument transformer
IOSK

The head type IOSK oil paper insulated current transformers follows the current IEC and IEEE/ANSI standards. It is outstanding in controlling insulation stress using fine graded bushing. ...

See the other products
Trench Group
instrument transformer
instrument transformer
CT

Split-Core Current Transformers Split-Core Current Transformers (CTs) are designed for applications where it is difficult or uneconomical to open the primary conductor ...

current transformer
current transformer
CT1231-A1

Primary current: 30 A

Current transformers for energy meters single phase and three phase metering in Residential Metering applications. KEY FEATURES •High Linearity •Low cost •PCB Mountable •High Over current ...

See the other products
Electrohms
instrument transformer
instrument transformer

Since 1984, the current transformers from CG operate with high quality performance in 60 countries. These transformers comply with international quality standards to ensure efficient ...

See the other products
CG Power Systems
current transformer
current transformer
004805500

Primary voltage: 1.3 V
Secondary voltage: 1.3 V
Primary current: 50, 1 A

Applications „ Balanced systems: network analyzers, automatic power factor correction systems (PFCs) Features „ Connection terminal with cover (IP20) for universal connection, no fork needed „ Bus bar or din rail mounting, included complete ...

See the other products
ETI
current transformer
current transformer
M53Q series

Primary voltage: 50 V - 300 V
Secondary voltage: 5 V

Ebony Series Measuring and Protection The range of Crompton Instruments Ebony current transformers offers wide system current ratings, apertures, busbar and case sizes to suit every ...

See the other products
Crompton Instruments
current transformer
current transformer
ATM9

Electric power: 3,060, 2,570, 490 kVA
Primary voltage: 25,000 V
Secondary voltage: 2,570 V

EMU Type ATM9 Main Transformer Type:ATM9 Usage: Type CRH2 EMU with speed of 200KM/h and above Main technical features Mode: Single-phase, shell-type, non-pressure sealed type; Mode of rectification: Input ...

rectifier transformer
rectifier transformer
OTR

Primary voltage: 0 V - 170,000 V
Secondary voltage: 0 V - 750,000 V
Primary current: 0 A - 100,000 A

... secondary LV windings, variable flux regulation by booster or by autotransformer. These transformers are used to feed rectifiers, converting AC sources to DC and supplying an adjustable ...

current transformer
current transformer

Electric power: 750, 1,000, 1,500, 2,000 kVA
Primary voltage: 40 V - 600 V
Secondary voltage: 23 V - 240 V

Electromagnetic control components demand inrush currents up to 10 times the transformers nominal rating without sacrificing secondary voltage stability beyond practical limits. International ...

current transformer
current transformer
C-08

Primary current: 15, 20, 5, 10 A
Secondary current: 2 mA - 20 mA
Frequency: 50, 60 Hz

CURRENT TRANSFORMERS FOR ELECTRONIC ENERGY METERS FEATURES: -Adopted high permeability core, high accuracy, excellent linear performance; -Anti-combustion plastics case; -Encapsulated with epoxy resin ...

See the other products
Yueqing RunEasy Electronic Technology Co.,Ltd.
current transformer
current transformer
Salvo

Primary voltage: 415 V
Secondary voltage: 230 V

Salvo Transformer Powered Doors Salvo Transformer is used to convert power supplies of 415VAC down to 230VAC. It is only required on sites where 230VAC is not available. It is supplied ...

current transformer
current transformer
JLD series

Primary voltage: 12 kV - 170 kV
Primary current: 1 A - 5,000 A
Frequency: 16.7, 50, 60 Hz

... bushing and the coupled current transformer part. The wall bushing provides the insulation against high voltage and also represents the primary winding of the current transformer. ...

See the other products
PFIFFNER International AG
current transformer
current transformer

Electric power: 7,000 kVA
Primary voltage: 11 kV

11KV 0.2CL Single Phase Outdoor Oil Current Transformer

power transformer
power transformer
ADLT6000

Primary current: 2.5 A - 605 A

... Characteristics of technical parameters Control way:Vector control without PG,V/F control. Overload way:150% rated current at 60s;180%rated current at 10s. Starting torque:0.5HZ/150%(SVC)(without PG ...

See the other products
Andeli Group Company
current transformer
current transformer
AKH-0.66/K-Φ series

Primary current: 6,000 A

... 0.66/K-Φ series current transformer General Current Transformer (CT) is used to transform the high AC current to small easily ...

See the other products
ACREL CO., LTD.
current transformer
current transformer
936A

Electric power: 15 W
Output power kVA: 8.5 kVA
Primary voltage: 85 V - 264 V

... the sense transformer core flux to zero and produces an accurate output current independent of burden. The Model 936A was designed primarily for use with the Model 935A Current Source ...

current transformer
current transformer
T60404-A4xxx series

Electric power: 0 kVA
Primary voltage: 0 V
Secondary voltage: 0 V

The VAC type series for AC current transformers comprises various versions for a large number of applications. AC current transformers ...

See the other products
Vacuumschmelze GmbH & Co. KG
current transformer
current transformer
QI-300-I

Primary voltage: 11 V
Secondary voltage: 30 V
Primary current: 300 A

... transducer is loop-powered with current 4-20 mA so needs no direct power supply. It is the first loop-powered Hall effect transformer with 0.5% accuracy on the market. RMS AC/DC loop-powered ...

See the other products
qeed
current transformer
current transformer
ZT0 series

Secondary voltage: 6 mV - 21 mV
Primary current: 8.5 mA - 25 mA

Application: Heater Over Current Sensor Earth leakage breaker Ground fault circuit interrupter Residual current circuit breaker U.P.S. (Uninterrupted Power System) Protection of ...

See the other products
Thousand Hundred Industrial Co., Ltd.
current transformer
current transformer
POS SERIES

Output power kVA: 0 kVA - 0.04 kVA
Primary voltage: 0.7 kV
Primary current: 75 A - 300 A

... POS Series window-type low-voltage current transformers, intended for 600V (max.) power systems, are appropriate for electric engineering applications and distribution switchgears. Every ...

See the other products
CHALLENGE INDUSTRIAL CO., Ltd
current transformer
current transformer
LZB01-0.72

Primary voltage: 0.6 kV
Primary current: 1, 3 A
Frequency: 60 Hz

The current transformer is wound block type casting insulated indoor type product. It is used for measuring current、standardization、isolation、electricity power and relay ...

See the other products
Shenzhen Chuangyin Technology co., ltd.
current transformer
current transformer
AE120 series

Electric power: 0.05 kVA - 0.75 kVA
Primary voltage: 230, 460, 575 V
Secondary voltage: 95, 115 V

... Series Industrial Control Transformers are designed specifically for machine tool control circuit applications. These transformers have the ability to handle potentially damaging high in-rush currents ...

See the other products
Acme Electric
current transformer
current transformer
CMCT102

Primary current: 5 A

Model :CMCT102 Rated Input Current :5A Rated Output Current :2.5mA Turns Ratio :2000:1 Phase Angle Error :≤20'(Input 1A,sampling resistor 100Ω) Linear Range :0~20A(sampling resistor 100Ω) Mounting ...

See the other products
Cheemi Technology Co., Ltd
exhibit your products

& reach your clients in one place, all year round

Exhibit with us