MTM Power GmbH, the specialist for high quality power supplies, offers in its program DC/DC converters for automotive applications. The series WRC is available with 30, 60, 100 and 150 W. The converters are designed for mobile use acc. to EN 50 155, LES-DB-BN 411 002 and IEC 571-1 (railway, automotive). The battery voltages 24, 36, 72, 90 and 110 V +40/-45 % are covered with three input voltage ranges. All four power ranges have a high efficiency and are available with single or dual output voltages. The converters have an extreme high reliability (MTBF >1.000.000 h, TA = +40 °C) and an isolation of at least 2,1 kVDC (prim.-sec.). The temperature range is -40...+85 °C acc. to EN 50 155. Other important features are resistance against vibrations and reverse polarity protection at the input. The power supplies can be used in 19" racks or for wall mounting with H15 connector. The series WRC needs no ground load, is short circuit protected and has extensive monitoring and protection systems.
|
|
DCS50
Battery powered DC/DC Converters for 19 inch Rack mounting purposes are available from the Huhn-Rohrbacher Power Supply Company. The power range covers 50 to 150 watts.
* 19"-Eurostandard
* EMI Compliant Design
* 3U / 8 HP / 160mm
* Wide Range Input 2:1
* Single Output 50 Watts
* Galvanic Insulation
* CE Sign
|
|
TPCMQ48 DC/DC Converters
1U High, Up to 700 Watts with Integral Hot-Swap Provision
* 48VDC to 12 or 24VDC
* Includes Isolated 5V, ¼A Standby Output
* Hot-Swap Operation
* Wide Range 40 to 60VDC Input
* Integral LED Status Indicators
* I2C Serial Data Bus Option
* Up to 8.8 Watts/Cubic Inch Power Density
* Low Profile: 1.6 Inches (41mm) High
* Single Hot-Swappable Connector
* Reverse Air Flow Option
* Staged Pin Engagement
* ORing Diode on Output
* 1U, 19” Rack Holds 3 Units
* Active Current Sharing
* Optimized Thermal Management
* No Minimum Load
* Control & Monitoring Features
* DC to DC Converter
|
|
DC/DC 19“
Single output 20 - 100 watts
Plug-in Power Supplies for your 19-inch application.
– 19" plug-in module
– Primary/secondary insulation 3000 VAC
– Overvoltage protection
– Output SELV according to EN 60950 and permanent short-circuit proof
– Remote on/off
– Parallel connection possible with load sharing
– EMC Standards EN 50081-1 and EN 50082-2
– VMEbus signals or Power-Fail available upon request
|
|
DC/DC 19“
Multiple output 50 - 70 watts
Plug-in Power Supplies for your 19-inch application.
– 19" plug-in module
– Primary/secondary insulation 3000 VAC
– Overvoltage protection
– Output permanent short-circuit proof
– Ripple at output < 25 mVpp
– Interference emission according to EN 55011 / EN 55022 Class B
– Outputs SELV according to EN 60950
|
|
| ... products without technical information |
| |
ManualPresses are the economical solution for short run productions. The design of these presses is the direct result of our experience in multiple applications. They carry the hallmark of quality and precision. They provide:
Flexibility
- fast and easy set up
- quick and repeatable tool changeover
Ergonomic design
- hand lever position can be varied by 360°
- left and right hand versions available
Precision alignment
- smaller than 0.05 mm (precision ram and table bores)
Maintenance free
|
|
RACK PRESSES 400 kg / 600 kg
The rack and pinion main feature is providing constant linear power over the whole travel according to the applied load.
|
|
Manual Rack and Pinion Presses 2kN - 4kN
Sturdy and easy to operate presses
Cylindrical or V-shaped ways with adjustable stop
The press is guided by an H7 machined flat guidance
The daylight can be adjusted quickly and easily
A solid clamp safeguards the exact position of the press head
Table with wide T grooved clamping surfaces
Extended throat and height frames can be supplied but only for the 4kN HZP
The range of application can be substantially expanded by means of customer-specific accessory equipment
|
|
| ... products without technical information |
| |
|
|
|
|
General
The models of series EA-PS 800 19” are available as sin-
gle, dual or triple output power-supplies. By combining the
synchronised-rectifer and semi-resonant converter princip-
le, an effciency of up to 92% is achieved, thus making them
highly effcient and extremely reliable as a result.
Output
A choice of output voltages between 3.3V, 5V, 12-15V and
24V at power levels of 80W, 150W and 240W are available.
All outputs, main and supplementary, are provided with a
static current limit and a power limit circuit and are stabilised
independently, making them truly zero-load compatible,
fully short-circuit- and overload-proof.
All output voltages can be trimmed within a specifc range
by potentiometers located in the front panel to accommo-
date sensitive loads, and are visualised via LEDs.
The integrated OVP protects the equipment connected
from DC overvoltage damage.
Input
A wide input range of 90 up to 264 V AC (90…360 V DC)
with active PFC (power factor correction) makes them
suitable for a worldwide usage or as isolated DC/DC con-
verters as well.
Remote sense
The remote sensing circuit located at the H15 connector
can be connected to the input terminals of the load in order
to compensate for the voltage loss across the main output
wires, ensuring a stable and precise voltage to sensitive
equipment connected.
|
|
|
|
|
|
Features:
54 Models: 5 to 1000 Vdc, 3 to 900 Adc
Series and parallel master/slave operation
High dielectric withstand: 2500 Vac
50 Hz and 60 Hz input frequency
All user interface circuitry referenced to earth ground
OVT and OCT shutdown standard
Automatic V/I crossover
RS232 interface with SCPI commands
Optional IEEE-488, RS485, and Ethernet programming
Front panel potentiometers for stepless rotary control
Front panel calibration
User friendly controls and indicators
Remote Interface Software with self-teaching features
Drivers: Certified LabWindows/CVI and LabVIEW for GPIB, Serial, and TCP/IP communications
Load dependent cooling
High power factor
CE Mark
Magna-Power Electronics PQ SERIES combines the best of dc power processing with multiprocessor embedded control. A combination of high and medium frequency power processing technologies improves response, shrinks package size, and reduces cost. PQ SERIES power supplies are current fed and are more tolerant to abusive loads than conventional switching power supplies.
|
|
|
|
|
|
80 Models: 16 to 1000 Vdc, 20 to 2700 Adc
FEATURES:
Series and parallel master/slave operation
High dielectric withstand: 2500 Vac
50 Hz to 400 Hz input frequency
All user interface circuitry referenced to earth ground
OVT and OCT shutdown standard
Automatic V/I crossover
RS232 interface with SCPI commands
Optional IEEE-488, RS485, and Ethernet programming
Front panel potentiometers for stepless rotary control
Front panel calibration
User friendly controls and indicators
Remote Interface Software with self-teaching features
Drivers: Certified LabWindows/CVI and LabVIEW for GPIB, Serial, and TCP/IP communications
Load dependent cooling
High power factor
CE Mark
Magna-Power Electronics TS SERIES combines the best of dc power processing with multiprocessor embedded control. A combination of high and medium frequency power processing technologies improves response, shrinks package size, and reduces cost. TS SERIES power supplies are current fed and are more tolerant to abusive loads than conventional switching power supplies.
|
|
1U High, Up to 450 Watts with PFC and Hot-Swap Provision
FEATURES
- Includes Isolated 5V, ¼A Standby Output
- Hot-Swap Operation
- 12, 24 or 48VDC Outputs
- I2C Serial Data Bus Option
- Integral LED Status Indicators
- Up to 5.6 Watts/Cubic Inch
- Power Factor Corrected
- Low Profile: 1.6 Inches (41mm) High
- Single Hot-Swappable Connector
- Staged Pin Engagement
- ORing Diodes on Output
- 1U, 19" Racks Hold 2 or 3 Units*
- Active Current Sharing
- Universal 85 to 264VAC Input
- Class B EMI Input Filter
- Optimized Thermal Management
- No Minimum Load
- Control & Monitoring Features
- Front-End Switcher - PCG & TPCG
- SEMI F47 Compliant at Hi-Line
|
|
INTERTEC offers the widest selection of explosion-proof heaters worldwide.
- ATEX/CENELEC approvals for Europe
- CSA/NRTL approvals for America
- GOST approvals for the Russian Federation
Our EX-heaters in combination with EX-controllers satisfy all requirements from freeze protection as well as high demands in the analyse technic.
For further questions please contact: Tel.+49-9445/9532-0
|
|
THERM HI "smart heater" is a system consisting of
an explosion-proof electric heater and a
microprocessor, designed to control the air
temperature in instrument enclosures and protective
cabinets and to limit the surface temperature of the
heater.
The "option E" is equipped with an intrinsically safe
sensor, thus allowing measurement and accurate
regulation of the temperature of the instruments and
equipment (e.g. of manifolds).
... THERM HI heaters are designed to solve
sophisticated and complex heating problems in
hazardous areas, and in particular for high
temperature maintenance of analyzing equipment.
|
|
Heaters
Compact heaters to keeping at a moderate temperature of cabinets and housings with electrical electronic installations.
In switchgear cabinets condensation with variations in temperature, which can lead to malfunctions or to losses of the components in the switchgear cabinet, forms. Heaters prevent subnormal temperatures and work against the emergence of condensation. Heater blowers provide additionally for the even distribution of warm interior air. The heaters are appropriate for continuous operation.
|
|
-Pressure clamp connectors
-Dynamic heating up
-Wide voltage range
-Temperature limiting
-Energy saving
-Clip fixing
-Quick installation
These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature may not fall below a minimum value.
The aluminium profile heater body design has a chimney effect and distributes the heat evenly.
The pressure clamp connectors save time and simplify installation.
|
|
Low surface temperature
Quick mounting due to clip fixing
Double insulated (plastic)
Wide voltage range
Small size
Compact heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air.
The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design.
Our complete range of thermostats and hygrostats can directly be connected to the heater CS 060.
This heater is also available in a version with plug-in thermostat requiring no additional wiring (CSF 060).
Both versions are designed for permanent operation.
|
|
Technical details
• Protection class II (double insulated)
- protection type IP 54 (DK = IP 20)
• Temperature behavior:
· Self control, in variation of ambient temperature
· Dynamic heating-up
• Auxiliary fan attachable for improved air distribution
–> Auxiliary fan
• 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 2 x 0.75 mm² Silikon
–> Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm²
• Mounting position: vertical
• 3 Fastening alternatives (optional)
|
|
Heaters for the thermo-regulation of enclosures, for application on DIN rail, and available in three version:
- with bipolar (15-30W) or three-pole (45-150W) power cable
- with three-pole terminal block (45-150W)
- ventilated (250-400W)
|
|
|
Condensation poses a particular risk for control electronics, especially with outdoor siting, but also indoors. Various different output categories ensure that the correct thermal output is always available. In this way, the total required thermal output can be distributed with complete accuracy within an enclosure.
|
|
Units for DIN or screw mounting.
TH heaters, installed separately from cooling unit, must be connected to a TMC thermostat. When used to prevent cabinet condensate they should be electrically connected also when cabinet is off.In this cabinet it’s better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution.
|
|
Technical details
- Protection class I (ground wire) - protection type IP 54 (DK = IP 20)
- Temperature setting:
ON 25 °C - OFF 55 °C (operating temperature of heating
system itself)*
Tropical version possible: ON 35 °C - OFF 65 °C
-> Other settings upon request
- 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
- > Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm²
- Mounting position: vertical
- 2 fastening alternatives (optional)
Snap fitting for 35 mm DIN rail (figure 1)*
Screw fastening (figure 2)
|
|
PTC units for DIN bar application.
EH/FH heaters, installed separately from cooling unit, must be connected to TMC thermostat. When used to prevent cabinet condensate they should be eletrically connected also when cabinet is off.In this cabinet it’s better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution.
|
|
Technical Details
• Protection class I (ground wire) - protection type IP 65
• Temperature setting:
ON 25 °C - OFF 55 °C (operating temperature of
heating system itself)
Tropical version possible: ON 35 °C - OFF 65 °C
–> Other settings upon request
• Connection
Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
–> Other lengths upon request
• Mounting position: vertical
• Fastening
|
|
|
|