|
|
|
The Series A6 is a microprocessor based controller for positive, negative, and differential pressure as well as velocity and flow. The Series A6 has a 316L Stainless Steel cover to meet clean room and other high purity and wash down requirements. It features (2) 8A SPDT relays for control and an optional digitally scaleable 4-20 mA output. The associated software package allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the OLED display or uploaded using an Opti Link™ programming key. The OLED also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications.
|
|
|
|
|
|
The precise regulation of the air flow into sewage basins does not only influence the optimal quality of your cleaning process but furthermore still saves pure money because the energy-intensive compressed air is well applied in optimal quantities.
A too low oxygen supply leads to insufficient pollutant reduction and consequently to a reduced cleaning performance. In the worst case, an infringement of the desired limits occurs.
A too generous ventilation doesn’t bring any higher cleaning performance, but the energy costs for useless compressor performance can impair your installation effectiveness quite considerably.
Deltafit secures optimum oxygen input to your prozess, saves pure energy costs, works also under heaviest conditions for years without any maintenance – and fault-free. The optimally adapted components are prooving their precision and reliability in thousands of industrial installations in the entire process industry. The ready-to-go-setup components are ready mounted and do not need any startup efforts after installation!
Fluids: Air for sewage basins or combustion air in process industries
Pipe diameters: 65..500 mm (2,5”-20”) (others on request)
Process conditions: -40..250 °C (others on request)
0..10 bar (others on request)
Ultrapure to higly inpure air
|
|
|
|
|
|
Fluids: Gas, Steam, Liquids
Diameters of pipes/ channels:
0..20 mm deltaflow DF8
15..100mm deltaflow DF10M
65..3000mm deltaflow DF25
500..15000mm deltaflow DF50
Operating conditions:
-250..1240 °C
0..800 bar
Pure to extremely contaminated, aggressive media
Eexia
TRD
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how %u2013 systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software
|
|
|
|
|
|
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how – systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software
|
|
LSP 1 - air-flushing system for dust laden gases
Used together with dp primaray elements such as orifice, venturi or pitot tubes, LSP1 permits the measurement of extremely dusty gases.
Connected to a dp-Primary element and the dp-transmitter, the LSP1 cleans the dp-channels of the promary element efficiently from dust, dirt and condensation.
The LSP1 has been developed and tested in close co-operation with leading power plant operators and is also used successfully for security installations and cut-off installations.
Applications
Primary, secondary and recycled air-volume-measurement, measurement of waste-gas volume in the chemical industry, power plants and incineration plants.
Dusty return air from the production
A ir containing cement
Blast furnace gas, coke-gas, throat-gas
Maintenance intensive primary cells like venturis, orifices, nozzles can be equipped subsequently
|
|
|
|
|
|
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how – systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software
|
|
|
|
|
|
Flow Measurement
Honeywell's flow transmitters measure differential pressure, absolute or gauge pressure and process temperature.
Smartline Configuration Toolkit
Honeywell's Smartline Configuration Toolkit (SCT 3000) is an engineering and maintenance tool designed to complement the Honeywell Smart Field Communicator. The SCT 3000 allows easy access to all Smartline configuration database parameters using Windows technology.
SMV 3000 Smart Multivariable
Honeywell's SMV 3000 Smart Multivariable Flow Transmitter measures three separate process variables simultaneously with the ability to calculate compensated mass or volume flow rate as a fourth process variable according to standard industry methods for air, gases, steam and liquids.
MCToolkit
The Honeywell MC Toolkit Configurator is a Pocket PC-based engineering and maintenance tool for configuring, monitoring, diagnosing and managing smart field instruments/devices.
VersaFlow, Coriolis
The VersaFlow mass flow sensor reliably measures mass flow, density, volume, temperature, mass or volume concentration, and solids content
VersaFlow, Magnetic
The VersaFlow Mag 4000 is suitable for the most demanding applications. All meters consist of a sensor and a converter that may be integrally or remotely mounted.
VersaFlow, Ultrasonic
The Honeywell VersaFlow Sonic 1000 is an ultrasonic clamp-on flowmeter that can be mounted on the outside of a pipe to measure the flowrate of liquids.
VersaFlow, Vortex
The VersaFlow Vortex 100 is the only vortex flow meter with integrated pressure and temperature compensation in 2-wire technology
|
|
Materials of Construction
This fitting is made of the following components:-
* The body is produced in acetal copolymer
* 'O'Rings are nitrile rubber
* The collet is produced in acetal copolymer with stainless steel teeth
|
|
|
|
|
|
The DRESSER®ROOTS® Style 351 Pipeline Strainer is designed to protect precision devices, such as regulation and metering equipment installed downstream of the strainer, from entrained system debris such as plastic shavings, fine particles of dirt, stones, gravel, rust, pipe scale and weld slag.
Check out these Style 351 product features:
- Low pressure drop is achieved through a large element area and venturi port design.
- The elements are interchangeable and consist of corrosion resistant stainless steel in 20 and 100 mesh configurations and back-up disc for long service life.
- The streamlined flow path is sealed with an elastomeric ring in the body bore which provides positive debris removal and prevents debris from traveling downstream.
- The debris bow! has sufficient volume to provide extended service intervals and is tapped for cleaning or valve attachment for blowdown.
- Available in threaded, flanged or weld end configurations.
- Ideally suited for natural gas and compressed air applications.
- May be installed in vertical or horizontal position.
|
|
Description:
The Model FD-1500 Filter Dryer filters and de-hydrates supply gas for Flexflo™ Pilots. The FD-1500 Filter-Dryer provides superior filtration and dehydration with 110 square inches of 10 micron filtering media and 2.0 pounds of silica gel. The FD-1500 incorporates an easy-to-replace "spin on" cartridge made up of a high quality, high capacity nylon and fiberglass filter element reinforced with stainless steel mesh. All FD-1500's are fully Hydrotest to 2.5 times the working pressure to ensure the integrity of the pressure vessel. Final Filter Element.
|
|
| ... products without technical information |
| |
Available Temperature Range: -400°F to +350°F
continuous (to +400°F intermittent heat).
End Fittings: MS flared and flanged styles are
recommended. Other types available on request.
Bearing Styles: Ceramic hybrid ball bearings sizes 1¼”
through 12”. Stainless steel ball bearings sizes ¼” through
1”.
Materials: 316 stainless steel standard. Consult with
applications group for corrosive applications. Broad material
list available.
*** Linearity is density-dependent for a given meter.
Consult factory for details.
|
|
The CAT3 is a DC or AC powered, microprocessor
controlled transmitter. It outputs a pulse scaled per unit of
flow, and analog signal proportional to flow rate. The
CAT3 can be configured with High and Low alarms.
|
|
Low cost.
· Outstanding accuracy.
· Provides wide flow ranges (10:1 to 100:1 turndown ranges available).
· One piece 316/316L S/S Construction for most pressures.
· For use with unique Hoffer high pressure 316/316L or carbon steel mating flange kits,
supplied complete with SAE J429 Grade 8 high yield strength bolts and "O" rings.
· Operate over a wide range of temperatures.
· Sizes 1/4" through 2". Pressure ratings of 3,000, 6,000, 8,000, and 10,000 psi available
for most sizes.
· Larger sizes and pressures available upon request. Contact factory.
|
|
OUTSTANDING FEATURES
· Low cost.
· Outstanding accuracy.
· Provides wide flow ranges (10:1 to
100:1 turndown ranges available).
· Wide variety of process connections
available.
· Wide selection of construction
materials.
· Operate over a wide range of
temperatures and pressures.
|
|
The Hoffer Sanitary Design Turbine flowmeter is accepted as
meeting 3-A Sanitary Standard No. 28-03 for measurement of
process liquids where high sanitary standards are required.
Available in 11 sizes, ¼” to 3” with standard Tri-Clamp™
fittings, covering flow rates for 0.35 to 650 GPM.
|
|
The flowmeter pickup coil senses
the motion of the rotor and converts it
to a pulsing electrical signal which is
of a discrete digital nature. Three
basic pickup types are offered for use
with the MF Series which will satisfy
standard electrical interface
requirements for turbine flowmeters.
|
|
Paddlewheel flow meters for pipe sizes 1/2-8 inches
-High-quality ruby bearings for excellent low-flow performance and long life
-One easily-replaced moving part
-Pickup exerts no magnetic drag on the rotor
-Square-wave frequency output can connect directly to PLC’s or counter controls
-Indicator or transmitter can be mounted on the flowmeter or remote
|
|
1MX = Magnetic pickup coil with 1” riser on meter body for mounting of
enclosures and electronics.
1MX3/0=Magnetic pickup coil with 1" riser and enclosure Class I, Groups C & D.
PED-CE =PED-CE mark required for Europe requires the operating temperature and
pressure be given and will be marked on the housing.
CE = CE mark required for Europe.
|
|
The Hoffer Sanitary Design Turbine flowmeter is accepted as
meeting 3-A Sanitary Standard No. 28-03 for measurement of
process liquids where high sanitary standards are required.
Available in 11 sizes, ¼” to 3” with standard Tri-Clamp™
fittings, covering flow rates for 0.35 to 650 GPM.
|
|
Hoffer flow control
Controls turbine flowmeters
Of all the various types of flow transducers available to industry today. None are so universally applicable as turbine flowmeters. They continue to be the most common way to measure flow electronically and have the ability to measure available upon request offering detailed, technical information.
|
|
FLOW RANGE (Note 1)
Ranges shown are standard ranges — other ranges are available. Contact Hoffer Flow Controls Applications Group.
BEARING TYPES (Note 2)
—CB Hybrid Ceramic, Self-lubricating shielded ball bearings. Ball bearings must be used on CO2, may be used on H2O and never on H2O/Sand or CS.
—C Hard Carbon Composite sleeve bearings. For use on H2O only.
—T Tungsten Carbide sleeve bearings. Tungsten Carbide must be used on H2O/Sand and CS, may be used on H2O, and never used on CO2.
|
|
Hoffer inline turbine flowmeters are
velocity measuring devices, which is
to say they measure the average
velocity of a fluid flowing through
the body of the meter. See
Illustration 1 for details on the
construction of the Hoffer inline
turbine flowmeter. Mounted within
the body of a Hoffer liquid turbine
flowmeter is a vaned rotor.
|
|
PLASTIC IMPELLER FLOWMETERS FOR CHEMICALS
These flowmeters have a pulse out. Construction is simple. Rangability is good. Cost is low.
SRP and SRT flowmeters
-3/8 to 1 inch
-5-40 GPM max flows
-20-150 LPM max flows
-TFE or Polypro bodies
-Threaded ports
-High resolution rotors optional
-Ruby bearings
-Very high rangability
|
|
The Hoffer Sanitary Design Turbine flowmeter is accepted as
meeting 3-A Sanitary Standard No. 28-03 for measurement of
process liquids where high sanitary standards are required.
Available in 11 sizes, ¼” to 3” with standard Tri-Clamp™
fittings, covering flow rates for 0.35 to 650 GPM.
|
|
We are proud that you have selected a Hoffer Turbine Mini-
Flowmeter, the finest precision flow transducer on the market.
The Hoffer MF Series of Mini-Flowmeters are designed to meet the
need for a high quality low flow measurement device for service in
low to moderate viscosity clean liquids and for gas applications.
|
|
Hoffer flow control
Controls turbine flowmeters
Of all the various types of flow transducers available to industry today. None are so universally applicable as turbine flowmeters. They continue to be the most common way to measure flow electronically and have the ability to measure available upon request offering detailed, technical information.
|
|
OUTSTANDING FEATURES
· Low cost.
· Outstanding accuracy.
· Provides wide flow ranges.
· Wide variety of process connections
available.*
· Operate over a wide range of
temperatures and pressures.
· Exclusive use of hybrid ceramic ball
bearings provide superior life.
|
|
LC Turbine Flow Meters
- Sizes: 1/4" through 12"
- Flow Rates: 0.25 - 12,000 GPM
- End Connections: ANSI, NPT (¼ to 2"), Tri Clover, Flare Tube, Wafer
- Pressure Ratings: 150 - 2,500 ANSI
- Materials of Construction: Body: 304,316,316L SS; Rotor: 17-4 pH SS
- Bearing: Metal Ball, Carbide Sleeve, Cryo Ball, Fluorosint Sleeve
- Accuracy: Capable of ±0.25% of rate over 10:1 range
- Repeatability: Capable of 0.05% of reading over entire range
|
|
|
|