The Series A6 is a microprocessor based controller for positive, negative, and differential pressure as well as velocity and flow. The Series A6 has a 316L Stainless Steel cover to meet clean room and other high purity and wash down requirements. It features (2) 8A SPDT relays for control and an optional digitally scaleable 4-20 mA output. The associated software package allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the OLED display or uploaded using an Opti Link™ programming key. The OLED also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications.
|
|
|
|
|
|
The precise regulation of the air flow into sewage basins does not only influence the optimal quality of your cleaning process but furthermore still saves pure money because the energy-intensive compressed air is well applied in optimal quantities.
A too low oxygen supply leads to insufficient pollutant reduction and consequently to a reduced cleaning performance. In the worst case, an infringement of the desired limits occurs.
A too generous ventilation doesn’t bring any higher cleaning performance, but the energy costs for useless compressor performance can impair your installation effectiveness quite considerably.
Deltafit secures optimum oxygen input to your prozess, saves pure energy costs, works also under heaviest conditions for years without any maintenance – and fault-free. The optimally adapted components are prooving their precision and reliability in thousands of industrial installations in the entire process industry. The ready-to-go-setup components are ready mounted and do not need any startup efforts after installation!
Fluids: Air for sewage basins or combustion air in process industries
Pipe diameters: 65..500 mm (2,5”-20”) (others on request)
Process conditions: -40..250 °C (others on request)
0..10 bar (others on request)
Ultrapure to higly inpure air
|
|
|
|
|
|
Fluids: Gas, Steam, Liquids
Diameters of pipes/ channels:
0..20 mm deltaflow DF8
15..100mm deltaflow DF10M
65..3000mm deltaflow DF25
500..15000mm deltaflow DF50
Operating conditions:
-250..1240 °C
0..800 bar
Pure to extremely contaminated, aggressive media
Eexia
TRD
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how %u2013 systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software
|
|
LSP 1 - air-flushing system for dust laden gases
Used together with dp primaray elements such as orifice, venturi or pitot tubes, LSP1 permits the measurement of extremely dusty gases.
Connected to a dp-Primary element and the dp-transmitter, the LSP1 cleans the dp-channels of the promary element efficiently from dust, dirt and condensation.
The LSP1 has been developed and tested in close co-operation with leading power plant operators and is also used successfully for security installations and cut-off installations.
Applications
Primary, secondary and recycled air-volume-measurement, measurement of waste-gas volume in the chemical industry, power plants and incineration plants.
Dusty return air from the production
A ir containing cement
Blast furnace gas, coke-gas, throat-gas
Maintenance intensive primary cells like venturis, orifices, nozzles can be equipped subsequently
|
|
|
|
|
|
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how – systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software
|
|
|
|
|
|
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how – systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software
|
|
|
|
|
|
Flow Measurement
Honeywell's flow transmitters measure differential pressure, absolute or gauge pressure and process temperature.
Smartline Configuration Toolkit
Honeywell's Smartline Configuration Toolkit (SCT 3000) is an engineering and maintenance tool designed to complement the Honeywell Smart Field Communicator. The SCT 3000 allows easy access to all Smartline configuration database parameters using Windows technology.
SMV 3000 Smart Multivariable
Honeywell's SMV 3000 Smart Multivariable Flow Transmitter measures three separate process variables simultaneously with the ability to calculate compensated mass or volume flow rate as a fourth process variable according to standard industry methods for air, gases, steam and liquids.
MCToolkit
The Honeywell MC Toolkit Configurator is a Pocket PC-based engineering and maintenance tool for configuring, monitoring, diagnosing and managing smart field instruments/devices.
VersaFlow, Coriolis
The VersaFlow mass flow sensor reliably measures mass flow, density, volume, temperature, mass or volume concentration, and solids content
VersaFlow, Magnetic
The VersaFlow Mag 4000 is suitable for the most demanding applications. All meters consist of a sensor and a converter that may be integrally or remotely mounted.
VersaFlow, Ultrasonic
The Honeywell VersaFlow Sonic 1000 is an ultrasonic clamp-on flowmeter that can be mounted on the outside of a pipe to measure the flowrate of liquids.
VersaFlow, Vortex
The VersaFlow Vortex 100 is the only vortex flow meter with integrated pressure and temperature compensation in 2-wire technology
|
|
Materials of Construction
This fitting is made of the following components:-
* The body is produced in acetal copolymer
* 'O'Rings are nitrile rubber
* The collet is produced in acetal copolymer with stainless steel teeth
|
|
|
|
|
|
The DRESSER®ROOTS® Style 351 Pipeline Strainer is designed to protect precision devices, such as regulation and metering equipment installed downstream of the strainer, from entrained system debris such as plastic shavings, fine particles of dirt, stones, gravel, rust, pipe scale and weld slag.
Check out these Style 351 product features:
- Low pressure drop is achieved through a large element area and venturi port design.
- The elements are interchangeable and consist of corrosion resistant stainless steel in 20 and 100 mesh configurations and back-up disc for long service life.
- The streamlined flow path is sealed with an elastomeric ring in the body bore which provides positive debris removal and prevents debris from traveling downstream.
- The debris bow! has sufficient volume to provide extended service intervals and is tapped for cleaning or valve attachment for blowdown.
- Available in threaded, flanged or weld end configurations.
- Ideally suited for natural gas and compressed air applications.
- May be installed in vertical or horizontal position.
|
|
Description:
The Model FD-1500 Filter Dryer filters and de-hydrates supply gas for Flexflo™ Pilots. The FD-1500 Filter-Dryer provides superior filtration and dehydration with 110 square inches of 10 micron filtering media and 2.0 pounds of silica gel. The FD-1500 incorporates an easy-to-replace "spin on" cartridge made up of a high quality, high capacity nylon and fiberglass filter element reinforced with stainless steel mesh. All FD-1500's are fully Hydrotest to 2.5 times the working pressure to ensure the integrity of the pressure vessel. Final Filter Element.
|
|
Flowcon: Automatic Flow Regulator
Accurate Control and Perfect Process Monitoring
- Precise, stable mold temperature through automatic control
- The development of this unit is based on many years of applied experience.
- Microprocessor controlled accuracy +/- 1°C
- Up to 8 zones can be controlled individually.
- Storage of setup data for 7 different molds
- A tolerance window can be set on the display. If the temperature exceeds the tolerance a buzzer or alarm contact is activated.
- Serial interface for data transfer to lmm standard
- Secures the quality of the molding process by perfect temperature control and monitoring.
- Plunger type solenoid valves with large seat diameter ensure operation even with poor water quality.
|
|
Users of conventional universal display units can have difficulty in making use of their device´s options menu. Special applications require many more functions that are often not available with conventional units.
KRAL BEM 300 to 500 electronic units enhances the KRAL Volumeter performance.
Your advantages:
- Two-channel, i.e. differential measurement.
- Temperature and pressure pulse compensation.
- Measurement conversion.
- 7 point linearization.
- Limit value for a relay output, i.e. regulation of a bypass valve.
- Threshold value for signal suppression.
- Clear and easily readable display.
- Accurate handling by the use of a clear menu structure.
- Multiple mounting options. (KRAL Volumeter, wall, pipe, control panel).
|
|
FS5000 Flow Switch Controller
The FS5000 Flow Switch Controller is designed for use in applications that require flow/no-flow control of metering pumps and other devices. It includes a flow switch and three (3) 115V receptacles that are powered with flow and one (1) 115V service receptacle. Power indicator light, flow indicator light and test switch are included.
|
|
| ... products without technical information |
| |
|
|