The GammaRAE II-R is two instruments in one: it has the rapid response of a detector and the accurate dose measurement of a dosimeter. It is designed specifically to meet the needs of first responders.
This instrument contains two separate sensors. The Cesium Iodide (CsI) scintillator provides a fast, two-second response to radiological threats, while the energy-compensated PIN diode provides high dose rate range coverage and accurate dose measurements.
The GammaRAE II-R accumulates accurate total dose. Stored dosage data can be cumulative or reset for each use period. It alerts the wearer with a loud audible alarm, big, bright flashing LEDs, and a built-in vibration alarm. For stealth operations, law enforcement personnel can disable each alarm individually.
Immersible (IP67) design makes for reliable operation in wet environments and easy decontamination. IS certification permits operation in potentially flammable/explosive environments. |
|
| ... products without technical information |
| |
Small Industrial Motor Alarm is an omnidirectional siren,which are mainly used in Various industrial environments,such as factory buildings,workshops,warehouses,mining industry,etc
The character of siren list as follow:
1.Power arbitrary choices: (cell or
battery) DC 12 V, 24V, 48V, the exchange of 110 V, 120V, 220V
2. High frequency; 700 Hz - 1700Hz alarm sound very easy to distinguish between noise and the environment, clear, piercing and sharp.
3. Extensive application areas: automobiles, trains, ships, airports, ports, Crossing platform, silver floor, schools, hospitals, residential areas, shopping centers, warehouses, hotels, military units, factory construction, mining, sluice, and other places.
4. Strong compatibility; With smoke detectors, gas industrial gas sensors, infrared sensors, liquid level sensors, timer, anti-theft alarm system, such as the various-connected sensors can also be used alone, which is different from other alarm signals in the high-frequency sound alarm sound source.
5. Several installation forms: horizontal, vertical, activities - and vehicle-mounted, fixed, wall-type, embedded.
6.Design: fashion, unique, innovative, artistic, and easy to integrate into the use of premises, both embellishment and played beautiful scenery |
|
Menvier and JSB are market leaders in the fields of fire detection systems. The product range now includes:
- Conventional Fire Panels and Ancillaries
- Analogue Addressable Fire Panels and Ancillaries
Fire Solutions Catalogue and Design Guide are available
|
|
| When automatic 24/7 fire protection is required, select from our complete line of AUTOPULSE® detection, control and fire suppression system release panels. Detection options include smoke, heat and flame detection. Also consider our VESDA® aspirating smoke detection technology. |
|
| ... products without technical information |
| |
| ... products without technical information |
| |
Electromagnetic Inteference (EMI) causes equipment malfunction in many applications. EMI is an increasingly persistant problem anywhere sensitive electronics equipment is used.
Typical issues associated with EMI are equipment lock-ups, random equipment malfunction, data corruption, software and parametric errors along with many others.
|
|
Stop leaking your money!! AWS series water leak alarm provides an efficient and ecomonic way to prevent any possible damage or loss caused by leakage.
The AWS series water leak alarm equipped with LED and siren to inform you when any leakage occurred.
- Adjustable sensitivity level.
- Detecting loop provides efficient protection by warning alarm
- With water-proof and anti-insect
- Length of detecting line is adjustable upon request.
- Easy installation, with Wall mount & Rail-rack mount type for flexible applications
It is perfect for offices, storage room, data room, server room, monitoring center, pipes, or tanks. |
|
The Intelligent Professional transmitter pairs with the iT Alarm, a DIN-rail mountable alarm with three programmable industrial relays for use in vibration industrial monitoring systems or process control systems. The iT401 Alarm, which compares the 4-20 mA input from the transmitter against user-defined high or low setpoints, triggers the relays and/or provides an alert when the input deviates from acceptable levels. The front panel controls and digital LED readout make this unit very user friendly.
The real advantage of this unit is that it can also be used with any 4-20 mA sensor, including pressure, temperature, flow, speed and especially Wilcoxon’s popular LPS™ vibration transducers. |
|
| ... products without technical information |
| |
| Available for single or dual alarm applications, Lake's Flow Alarms/Switches can protect expensive equipment and reduce downtime by ensuring sufficient flows of coolants and lubrication. Offered in aluminum, brass or stainless steel for compatibility with most fluids, all units feature NEMA Type 4X enclosures to withstand outdoor/exposed applications and frequent maintenance wash downs. Field adjustable alarm setting allows for convenient changes with an allen wrench. |
|
Low Volume Flowmeter and -switches
Variable Area Flowmeter and -switches
Paddle Type Flowmeter and -switches
Rotating Vane Flowmeter and -switches
Flow Measurement without Moving Parts
Flow indicator |
|
Easily view status of station alarms. Save engineering time and effort with simple wiring and configuration. Dip switch selection provides for either N/O or N/C input. View alarms even if there has been a power interruption. Alarms are sealed in until acknowledged. Substation and Plant Grade Equipment provides for secure operation in station environments. Wide temperature range (-40° to +85°C) and surge protection. Manned Station Annunciator - Output contact can drive alarm horn or external light. Super-bright LED output provides easily visible indication of alarm point in any ambient lighting condition. Unmanned Station Annunciator - Seal-in of momentary alarms provides a visual indication of event history.
|
|
| Configurable indicators for temperature, pressure, force, current and AC voltage, position, normalized inputs, with up to 4 alarm outputs, analog retransmission output, serial communication |
|
The LHL, LHI meets or exceeds factory Mutual (FM) Approval Standard temperature Limit switches Class 3545.
They are designed to automatically shut down a process when the measured value exceeds a pre-programmed value.
Alarm masking:
Puts the alarms in the stand by condition (mask) during instrument power up or professional masks a deviation or band alarm if the alarm condition is a
result of a set point change. In both situations the instrument maintains the alarm masking for the duration of the alarm condition.
Logic input:
These instruments are equipped with a logic input used to acknowledge an alarm condition by an external contact.
Maximum and/or minimum data hold:
The LHI is able to memorize the maximum and the minimum measured value. This function is automatically enabled at instrument power up
and it is always active.
Supplier of power supply failure indication:
These instruments are able to signal if a power failure occurs during normal instrument operation.
Power fail recovery settings are user configurable. |
|
The model 1390 indicator offers a field scalable professional display and dual, configurable professional alarms to meet your changing pressure indication requirements. The available optically isolated mA/VDC linear retransmission enables the user to log process trends, a valuable feature for SPC and SQC. A simple front professional panel instrument calibration and compact professional profile make the model 1390 the ideal indicator for your process.
|
|
| ... products without technical information |
| |
Low Volume Flowmeter and -switches
Variable Area Flowmeter and -switches
Paddle Type Flowmeter and -switches
Rotating Vane Flowmeter and -switches
Flow Measurement without Moving Parts
Flow indicator |
|
FEATURES:
- Control/Monitor/Alarm via GSM mobile phone, no distance limitation. User can control/monitor/alarm their devices all over the world.
- 8 channels Analog input (4 -20 mA)
- 8 Relay outputs
- 8 Switch inputs, normal open, close alarm
- 8 Analog inputs: system can preset 4 mA and 20 mA input value according the real measuring value and setting display unit. It can read actual measuring data via the SMS (Short Message) requested, such as CH1= 28.0 C. CH2=53.7 %RH, CH3=7.01 pH........CH8= 230.5 ACV.
- Enable or disable Analog input alarm (High alarm, Low alarm) via SMS.
- Enable or disable switch Input alarm (close alarm) via SMS.
- Set relay output On/Off via SMS
- Dot matrix LCD display show Analog input value, Switch input and Relay output status.
- All setting value will be saved into EPROM IC, no loss.
- Mobile telephone can call out all channel measuring value, status of Switch input and Relay output at any time.
- Can default two telephone no., alarm SMS can be sent to two users.
- Build GSM mobile modem (dual band).
- After the SMS command sent by mobile phone, the confirm message will be sent back to the mobile, safe and no loss.
- Intelligent application , innovation, wide range, no limitation |
|
SATELNODE X8SR is the basic VHF receiver of the SATEL local area transfer system. Together with SATELCODE alarm transmitter from SATEL, it provides the easiest way of setting up a wireless alarm transfer system.
The SATELNODE X8SR comprises of a high quality radio receiver with excellent selectivity and stability.
It is capable of processing coded messages from SATELCODE professional transmitter.
The SATELNODE X8SR is also equipped with an RS-232 interface, which provides a flexible means of programming the industrial radio modem with a PC, to meet the varying needs of applications.
By means of the SATELCODE / SATELNODE alarm transfer equipment, SATEL has drastically lowered the threshold of setting up a local alarm transfer system.
SATELCODE is a versatile VHF radio transmitter from SATEL's extensive selection of radio modems. Together with its counterpart, the SATELNODE receiver, it provides the easiest way of setting up a wireless alarm transfer connection between two points.
The SATELCODE transmits a message that includes both address and alarm information. The number of possible different messages amounts several tens of thousands.
The configuration of a SATELCODE / SATELNODE system is straightforward and the installation quick and easy. The user benefits from minimum time spent in planning and materialization fo an alarm system. The radio modems are extremely reliable. The operation costs of the alarm transfer system are low, as there are practically no network charges. |
|
The space-saving communication-solution for technical installations.
Modem / SMS Alarm-Messender
All “CombiLine” models became developed specially for industrial surroundings and they are corresponding to the most currently data-transmission-norms.
With the help of the included software package, the modules will be configured easily over the COMinterface.
8 alarm-signal-inputs, 2 switchable signal-outputs.
By activation the input lines, faults will be announced by sending an SMS message and displayed on a mobile phone, voltage breakdowns will be indicated as well.
While power interruption, the modules remain in operation by using an optional built-in NiMH accumulator. |
|
| ... products without technical information |
| |
|
|