|
|
The most versatile, complete light source available with up to three singlemode wavelengths on a single port, or four wavelengths (two multimode and two singlemode) on two ports.
Applications
Link-loss characterization
Fiber identification
Key Features and Benefits
Can transmit with a wavelength-identification digital encrypted protocol so that any compatible unit can automatically use the proper calibration parameters
Autonomy of 120 hours
Instrument identification available in six languages
Highest output power in the industry
Three-year warranty and recommended calibration interval, for dramatically reduced cost of ownership
|
|
|
|
|
|
Features :
* 8 channels of user-selectable laser source modules
* ±3pm wavelength stability with ±0.003dB power stability
* Customer specified WDM DFB sources covering S, C, and L-bands at up to 20mW per channel
* Internal synchronous modulation to 500kHz
* Fiber optic switch modules available
* GPIB/IEEE488 and RS-232 interfaces
The FOM-7900B is a high-performance fiber-optic test and development platform with eight channels supporting plug-in laser source and fiber optic switch modules. This system provides a cost-effective solution for WDM and CWDM test applications including EDFA, SOA, and fiber optic component characterization.
Front panel plug-in modules are offered at user-specified wavelengths from 1475-1625nm including service channels at 1310, 1480, 1510, and 1625nm. Each channel can be tuned over a 1.7nm range with 0.001nm resolution. These sources can be customized to meet special requirements including fiber optic connector type, PM alignment and fiber, and center wavelength on ITU grid points.
For higher density WDM system requirements, up to 25 additional FOM-7900B mainframes can be linked together for a total of 200 channels, all controlled from a single GPIB address.
|
|
PerkinElmer’s new LED Fiber Optic Illuminator couples high intensity LED white light into fiber optic bundles for applications including medical endoscopy1, microscopy, and machine vision. It offers an energy-efficient, maintenance-free alternative to halogen and metal-halide fiber optic illuminators.
The LED source is comprised of high-power white LEDs, patent-pending optics to precisely couple light into fiber optics, heat sink and fan, linear light intensity control, and AC power supply. It has been designed to couple light into 3 -10 mm fiber.
|
|
Fiberoptic Light Sources
This style lighting uses two parts: a light source to create the light and a light guide to carry it to the target. Light sources come in a variety of wattages and bulb styles depending upon the application.
The LSX50 uses a high intensity discharge metal-halide solarc lamp, which offers five times the light output per watt compared to halogen sources. This is the light source best suited for coupling fiber optic cables, as it efficiently launches light into small diamter fiber bundles. It has an ACMI adapter interface, light attenuator and power cord.
|
|
SpectraGen 100 SLH light source
Internal halogen light source.
Compact design
Quick, easy and tool-less lamp change
Perfect color rendering
Operates with lamps between 35 W and 100 W
Fiber optics and power connection remain undisturbed during lamp replacement
Low noise fan assisted cooling
Suitable for dry locations only
|
|
he KOHERAS SuperK™ has been the first commercial solution to provide scientists in diverse fields of research with a tool which was previously unavailable. Leading scientific institutions are working with this source and have given invaluable input for further development.
The KOHERAS SuperK™ is now available in four configurations:
SuperK™ Compact - 100 mW average output power from 500 to 2400 nm, typical fixed repetition rate 25kHz, pulse width 1 - 2 ns
SuperK™ Versa - > 1.5 Watt from 490 to 2400 nm, typical fixed repetition rate 40/80 MHz, master-source pulse width ~5 pS
SuperK™ Power - > 2.8 Watt from 460 to 2400 nm, typical fixed repetition rate 40/80 MHz, master-source pulse width ~5 pS
SuperK™ Extreme - > 4.5 Watt from 460 to 2400 nm, typical fixed repetition rate 40/80 MHz, master-source pulse width ~5 pS
|
|
BaySpec’s MiniliteTM Series fiber-coupled Narrowband and Wideband Light Sources are designed to enhance Spectral Domain OCT, Medical Imaging, Fiber Optic Sensing, Analytical Spectroscopy, and Test & Measurement capabilities in the 800nm-1650 nm wavelength region. Devices benefit from low-cost field proven telecommunication components.
Key Features:
- Card-mount or Bench-top Models available
- Fiber optic coupled, wide spectral coverage
- 5V wall power plug-and-play
- Solid state light source, reliable operation in harsh environments
- Operates over wide 0 to +70◦C temperature range
- Operates in high +85% relative humidity environments
- Covers wavelength ranges from 800-1650 nm
|
|
Lumitex Medical Devices creates, manufactures and distributes unique, cool devices for medical illumination. Our mission is to engineer light into sensitive applications that require light without heat or electricity, in user-friendly forms.
Our patented technologies are used to treat jaundice in infants, help surgeons better visualize deep surgical cavities, and provide ambient lighting in surgical equipment and suites.
Our engineering staff works closely with surgeons and medical companies to design the best solution for each lighting need. We apply a variety of unique light-delivery technologies that allow us to optimize trade-offs between flexibility, lighting characteristics and cost.
|
|
| ... products without technical information |
| |
|
|
|
|
High Sensitivity Spectrometers
The Maya series of spectrometers are particularly well suited for measurements in the UV range. Due to their high sensitivity, Maya spectrometers are also very well suited for low light level applications that require low detection limits and great dynamic range.
Applications
» Health Care measurements
» Light analysis
» Environmental monitoring
» Medical analysis
» Chemical research
» Physical characterisation
» Biology measurements
Features
» Back-thinned 2D FFT-CCD detectors
» Optional propriety order-sorting filters
» USB interface
» Fully programmable strobe signals
(single or continuous)
» 10 onboard digital user-programmable GPIOs
» Optical resolution up to ~ 0.035 nm FWHM
Advantages
» Excellent UV response
» Great signal-to-noise characteristics
» Wide dynamic range
» Up to 90% quantum efficiency
» No need for UV-sensitive coatings
» Low-noise electronics
» User friendly
» Runs on Windows, Mac OS or Linux
For more info please visit our website: www.oceanoptics.eu/maya
|
|
USB Series
The USB series of spectrometers are multipurpose spectrometer and can be used for most reflection, transmission and absorption measurements. The USB spectrometers are fast and are responsive from 200 to 1100 nm.
Applications
» Laboratory research
» Colour analysis
» Biochemical monitoring
» Light analysis
» Textile measurements
» Chemical identification
Features
» 1,000 full spectra per second
» Onboard, 2-MHz A/D converter
» Onboard programmable microcontroller
» USB-to-PC interface
» Linear CCD-array detector
» RoHS and CE compliance
» 10 user-programmable digital I/Os for interfacing to other equipment
» Trigger modes
Advantages
» Excellent UV response
» Easy setup
» User friendly
» No external power supply
» Flexible
» User-configured wavelength range and resolution
|
|
HR Series
The HR series of spectrometers provides users with high spectral response and optical resolution in a single unit. HR spectrometers are used where fast reactions need to be monitored and high resolution is necessary, such as characterizing lasers, measuring gas absorbance, and determining atomic emission lines.
Applications
» Semi conductor analysis
» Chemical research
» Gas absorbance measurements
» Defense material characterisation
» Paint & coating analysis
» Food analysis
Features
» Powerful 2-MHz A/D converter
» Programmable electronics
» USB-to-PC interface
» Linear CCD-array detector
» RoHS and CE compliance
» Trigger modes
Advantages
» Optical Resolutions up to 0.02 nm (FWHM)
» Plug and play operation
» No external power supply
» Flexible
» User-configured wavelength range and resolution
|
|
Jaz Series
The Jaz series form a revolution in optical sensing. Jaz units are unique stand alone systems consisting of stackable modules. The modular set up allows you to customize the system to your (changing) application needs. Jaz is ideal for field measurements, process analysis and remote sensing.
Applications
» Industrial process control
» Environmental analysis
» Agricultural enhancements
» Animal research
» Solar measurements
» Waste water analysis
» Light characterisation
Features
» Powerful onboard microprocessor
» Onboard display
» Modular / stackable
» Components share common electronics
» Ethernet connectivity
» SD card for data storage
» Battery module
» RoHS compliant
Advantages
» Standalone
» Modules operate both separately and together
» No need for PC
» No need for external power supply
» Flexible
» Portable
» User-friendly
» Replaceable slits and gratings
» Remotely accessible via computer
|
|
|
|
|
|
The AvaSpec-3648 Fiber Optic Spectrometers is based on the AvaBench-75 symmetrical Czerny-Turner design with 3648 pixel CCD Detector Array. The spectrometer has a fiber optic entrance connector (standard SMA, others possible), collimating and focusing mirror and diffractional grating. A choice of 16 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range. The AvaSpec-3648 comes with a 16 bit AD converter, and USB2.0 high speed interface. The AvaSpec- 3648 is especially suitable for measuring high resolution applications and thanks to the 10µsec electronic shutter has a wide dynamic range. An optional detector coating can enhance the CCD performance for the UV range and a detector collection lens offers high sensitivity.
Digital IO ports enable external triggering and control of shutter and pulsed light sources from the Avantes line of instruments.
The AvaSpec-3648 has a USB2 interface with fast data sampling of 270 spectra per second and data transfer in 3.7 msec and supports analog in-and outputs as well. Optional BluetoothÒ (-BT) communication and an SD card for on-board saving of spectra can be added. The AvaSpec-3648-USB2 runs on USB power and comes with AvaSoft-basic, a complete manual and USB interface cable. Multiple (up to 127) USB2 spectrometers with different detector types can be externally coupled (see section multi-channel spectrometers).
|
|
The AvaSpec-2048 Fiber Optic Spectrometer is based on the AvaBench-75 symmetrical Czerny-Turner design with 2048 pixel CCD Detector Array. The spectrometer has a fiber optic entrance connector (standard SMA, others possible), collimating and focusing mirror and diffractional grating. A choice of 15 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range. The AvaSpec-2048 can be delivered with 2 platforms of electronics with 14 bit AD converter; either with USB1.1 or the new USB2.0 interface. The AvaSpec-2048 is especially suitable for low light level and high resolution applications. An optional detector coating enhances the CCD performance for the UV range and a detector collection lens offers high sensitivity. Digital IO ports enable external triggering and control of shutter and pulsed light sources from the Avantes line of instruments.
|
|
The AvaSpec-2048x14 Fiber Optic Spectrometers is a back-thinned type CCD spectrometer with high quantum efficiency and high UV sensitivity. The optical design is based on the AvaBench-75 symmetrical Czerny-Turner design with a 2048x14 pixels high UV sensitive CCD image sensor. The image sensor is used as a linear array of 2048 pixels binning the vertical 14 pixels to optimize efficiency. The spectrometer has a fiber optic entrance connector (standard SMA, others possible), collimating and focusing mirror and a diffractional grating. A choice of 16 different gratings with different dispersion and blaze angles enable applications in the 200-1160nm range. The AvaSpec-2048x14 comes with a 16 bit AD converter, and USB2.0 high speed interface.
The AvaSpec- 2048x14 is especially suitable for measuring low light, fluorescence and UV- applications. Digital IO ports enable external triggering and control of shutter and pulsed light sources from the Avantes line of instruments.
|
|
Avantes offers a large family of laboratory spectrometer :
AvaSpec-128 Fiber Optic Spectrometer ; AvaSpec-2048TEC Thermo-electric Fiber Optic Spectrometer ; AvaSpec-256 ; AvaSpec Bluetooth Wireless Fiber Optic Spectrometer ; AvaSpec-1024 Fiber Optic Spectrometer ; AvaSpec stand alone Fiber Optic Spectrometer ; AvaSpec-2048 Fiber Optic Spectrometer ; AvaSpec-3648 Fiber Optic Spectrometer ; AvaSpec-2048x14 High UV-sens CCD Spectrometer ; AvaSpec-NIR256 Near-Infrared
Fiber Optic Spectrometer ; AvaSpec-Multichannel Fiber Optic Spectrometer ; AvaSpec-2048FT Fast Trigger Fiber Optic Spectrometer.
|
|
The NIR256-2.1 and NIR256-2.5 Near-infrared Spectrometers are designed for applications that require sensitivity in the near-infrared region such as tunable laser wavelength characterization and general NIR spectroscopy.
|
|
|
|
|
|
The AvaSpec-3648 Fiber Optic Spectrometers is based on the AvaBench-75 symmetrical Czerny-Turner design with 3648 pixel CCD Detector Array. The spectrometer has a fiber optic entrance connector (standard SMA, others possible), collimating and focusing mirror and diffractional grating. A choice of 15 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range. The AvaSpec-3648 comes with a 14 bit AD converter, and USB2.0 high speed interface. The AvaSpec- 3648 is especially suitable for measuring high speed and high resolution applications, such as LIBS and pulsed light sources. An optional detector coating can enhance the CCD performance for the UV range and a detector collection lens offers high sensitivity.
Digital IO ports enable external triggering and control of shutter and pulsed light sources from the Avantes line of instruments.
The new AvaSpec-3648 has a USB2 interface with fast data sampling of 270 spectra per second and data transfer in 3.7 msec and supports analog in-and outputs as well. Optional BluetoothÒ (-BT) communication and an SDRAM card for on-board saving of spectra can be added. The AvaSpec-3648-USB2 runs on USB power and comes with AvaSoft-basic, a complete manual and USB interface cable.
|
|
Quest™ X (BRC112E-V)
Features:
- UV and UV/Vis/NIR versions and Custom configured ranges
- Built-in 16 bit digitizer and USB PC interface
- High performance to cost ratio
- 0.5 and 1.5 nm spectral resolution versions as default
- Plug-and-play high speed USB 2.0/1.1 interface
- Up to over 180 complete spectra/s transfer speed via USB 2.0
- Low UV stray light
- 1 ms to 65,535 ms integration time control range
BRC112E-U and V products are low cost, high performance CCD spectrometers designed for UV, Vis and NIR applications. The devices employ a response enhanced 2048 element linear CCD array, built-in 16 bit digitizer with high speed USB 2.0/1.1 interface and low stray light optical bench.
The spectrometers come in two standard wavelength ranges; BRC112E-U covers UV and UV/Vis/NIR, and five standard configurations for BRC112E-V.
|
|
|
|
|
|
Astra SWIR Spectrometer
Features
- Wavelength range 1100 to approx 2200nm
- TE cooled InGaAs aray detector
- Original concave holographic grating
- Fibre Optic coupled
- PC controlled via USB2
- No moving parts
- Integral Tungsten-Halogen lamp
- Fast Scanning
- Programmable digital I/O
- Programmable analogue output
The integrated design of the AstraNet NIR fibre optic coupled spectrometer conserves bench space by housing all power supplies, electronics, optics and light sources in one attractively styled cover.
The instrument includes a powerful Tungsten-Halogen lamp, which is controlled by the electronics and synchronised with the detector. Full wavelength scans take a few mS and the intuitive software provides many interesting features. The digital I/O facility allows the software to be externally triggered, or provides a trigger to other devices.
The wide range of accessories includes cuvette holders, flowcells, immersion probes and reflectance probes. AstraNet can provide customised fixtures for almost any type of sample.
|
|
|
The high performance NIR InGaAs spectrometers use a linear photo diode array detector with 512 pixels (1024 optional) to provide maximum sensitivity. The NIR InGaAs spectrometers use single strand SMA-905 fiber optic input. Several models provide a variety of operational ranges and resolutions suitable for both spectroscopy and optical spectrum analysis. NIR applications include chemical ID and moisture analysis, SpectroRadiometry and optical power measurements, laser characterization, microsensor applications, and thicker thin-film measurements.
|
|
Prime™ V (BTC651E)
Features
- High QE with back-thinned 2-D CCD
- High throughput with 0.22 NA fast spectrograph
- Compact design: 210 x 119 x 130.5 mm
- 750 - 1075 nm wavelength coverage
- Other wavelength ranges are available upon request
- 2-D imaging capabili
BTC651E combines high efficiency optics, back-thinned CCD, and imaging spectrograph to provide the highest possible detection sensitivity in its class.
The BTC651E series spectrometers offer high throughput in a compact package. Low light applications, particularly Raman or Fluorescence benefit from the high photometric sensitivity.
With an improvement of 4 to 5 times greater than that of conventional crossed Czerny-Turner spectrographs and excellent imaging quality, a high performance low cost spectrometer is easy to use and affordable.
|
|
|
HAMAMATSU mini-spectrometers are polychromators integrated with optical elements , an image sensor and a circuit. Light to be measured is guided into the entrance port through an optical fiber and the spectrum measured with the built-in image sensor is output from the USB port to a PC for data acquisition.
|
|
TRISTAN OEM
Open-frame spectrometer for industrial applications
The TRISTAN OEM is an open-frame spectrometer designed for integration into existing hardware environments.
Performance
- Spectral range: 200-2200 nm
- Grating 100-1200 l/mm
- Slit size: 10 µm / 40 µm / 25 µm / 50 µm x 3 µm
- Stray light: 0.1% - 0.8%
- Resolution, optical: 0.5 - 15 nm
|
|
Fiber-optic spectrometers are optical instruments designed to measure light intensity in ultraviolet, visible, and infrared spectral regions. Light sources are often used with these spectrometers to illuminate a target or to act as a reference
Melles Griot offers two types of spectrometers. The standard resolution spectrometer is based on a 45-mm focal length optical bench with a 102-pixel detector. The high-resolution spectrometer uses a 75-mm focal length optical bench with a 2048-pixel detector. Both are available with a wide variety of gratings, slits and accessories.
|
|
TRISTAN USB
High Resolution Minispectrometer
TRISTAN USB was developed with the aim of making spectroscopy as easy as taking snapshots with a digital camera. Four off-the-shelf solutions have been designed around the most common requirements for spectral range, optical resolution and sensitivity. The TRISTAN USB provides the highest resolution that has ever been available in a TRISTAN spectrometer.
Performance
- Spectral range: 200 - 1100 nm
- Detector: CCD, 3648 pixel
- Resolution, optical: 1 -1.8 nm
- Stray light: 0.2% - 0.3%
- Dark noise: 1,8%
|
|
| ... products without technical information |
| |
|
|