Aluminium honeycomb vent panels for EMC screening in a range of styles and sizes. Steel honeycomb vents are also available.
|
|
• HIGH LEVEL OF EMI/RFI SUPPRESSION COMBINED
TO PASSAGE OF AIR IN SHIELDED ENCLOSURES
• ALUMINIUM HONEYCOMB FOR HIGHEST AIRFLOW OF
ANY VENT MEDIUM (LOW STATIC PRESSURE DROP)
• ALUMINIUM WIRE SCREEN SANDWICHED BETWEEN
RIGID EXPANDED MESHES FOR DUST ARRESTING
(INLET COOLING PANELS)
• FURNISHED READY TO INSTALL WITH STANDARD
ALUMINIUM FRAME AND EMI SHIELDING GASKET
(fastener or thru-holes on the frame for fixing)
|
|
SILAIR is a panel for electromagnetic protection and screening for ventilation, heating ducts, lighting apertures…
The metal honeycomb cells of SILAIR use the waveguide principle which provides excellent attenuation but a minimal loss of pressure.
It allows air to circulate while ensuring the electrical screening of the aperture.
The outer frame enables the SILAIR panel to be fixed to its support. In certain cases a conductive gasket is recommended between the frame and its support.
|
|
|
Leader Tech introduces its high performance EMI shielded air vent panels to its product range. Air vent panels are manufactured using aluminum, steel or brass and are available in various plating finishes and mounting configurations allowing for installation in most applications.
|
|
|
|
|
|
StreamShield™ Commercial EMI Vents
- available with fire barrier coatings
Low cost StreamShield vent panels provide high levels of EMI shielding in applications such as computer network and wireless infrastructure cabinets. These vent panels feature aluminum honeycomb within rolled aluminum frames. The result is a lightweight, high airflow solution for enclosures requiring both cooling and high levels (50 dB at 10 GHz) of shielding. An optional intumescent coating provides fire barrier properties. On exposure to flame or heat at 300°F (149°C) the coating expands rapidly to fill the honeycomb cells and prevent flame passage. Standard panels feature 1/8 inch (3.2 mm) honeycomb cells, 1/4 inch (6.4 mm) thick. Complete frame/honeycomb assemblies are chromate conversion coated.
SLIMVENT™ Thin Profile EMI Vents
Chomerics' SLIMVENT™ air ventilation panels provide 90 dB attenuation at 1 MHz to 50 dB at 10 GHz. The panels are made from expanded aluminum or monel (nickel-copper) foil, secured in an extruded aluminum frame only 0.187 inch (4.75 mm) thick. This narrow profile is ideal for accommodating critical space limitations at air intake and exhaust ports. The frame has an integral wire mesh gasket for EMI shielding at the mounting interface. SLIMVENT air panels are fabricated to customer specifications.
CHO-ITO™ - ITO Coated Conductive Windows
Chomerics offers a range of EMI shielded windows with ITO conductive coatings for use in EMI/RFI shielding applications. The combination of high visible light transmission, near neutral color and low electrical resistance make an ideal EMI/RFI shield for electronic displays requiring moderate shielding effectiveness and high quality optical properties. CHO-ITO™ is a cost effective alternative to a mesh laminated window.
WIN-SHIELD™ Shielded Windows and
Contrast Enhancement Filters
Chomerics WIN-SHIELD windows are performance-tested glass and plastic assemblies for displays requiring EMI radiation or susceptibility shielding. They provide highly effective EMI shielding and exceptional optical clarity. Windows can be produced in glass, plastic, or combinations of both. Shielding is provided by wire mesh or by deposited conductive coatings. Chomerics' prototype-to-production service includes an extensive line of spectrally matched filters to meet stringent contrast enhancement performance requirements for both flat and curved configurations.
|
|
What differentiates ATI-Circular EMI Vents from other conventional panels is the shape.
Billets, rods, bar and plate stock are fabricated into rigid frames for structural support.
Core materials of honeycomb in assorted thickness and cell size, 3-layer screen, multi-layered screen, rigid grill and combinations may be selected for circular vent assemblies. EMI gaskets and environmental seals can be applied. Plating options enhance shielding effectiveness. Through hole locations are customized for easy surface mount installation with standard 8-32 rivnuts or .203 diameter holes. ATI Circular Vent Panels are designed for a precise fit of round openings on mounting walls or enclosures. Circular Vents are ideal in applications where a conventional rectangular vent may impede mounting space. Alco's special circular vent process can be fabricated in ATI 90° Cell, ATI-Dual Stack or ATI 3-Layer designs.
|
|
|
ATI Dual Stack Ventilation panel is a high level EMI shielded air filter with superior performance. Extruded aluminum profiles surround dual layers of ¼-inch honeycomb and welded in place. Both honeycomb layers are positioned 90 degrees to each other, optimizing shielding effectiveness and minimizing the polarization characteristics of straight aluminum honeycomb. Alco-Multi Gasket, a combination of neoprene sponge and monel mesh or Alco-Knit, is installed on the panel. Hole locations are customized for easy surface mount installation with standard 8-32 rivnuts or .203 diameter holes. Plating options enhance shielding effectiveness.
|
|
|
ATI's brass and steel honeycomb vent panels are recommended when structural integrity, H-Field shielding effectiveness, harsh environmental conditions and durability are primary concerns. Brass or steel extrusions are customized to surround brass or steel honeycomb and welded in place. Continuous flow soldering provides enhanced contact between the honeycomb and frame improving integrity. Alco Multi-Gasket, a combination of neoprene sponge and monel mesh fit, most applications although Alco-Knit or conductive gaskets are available. Standard through holes and spacing for surface mounting installation is customized. Vents without gasketing can be welded in place. Brass vents are typically finished with tin lead plating. Steel vents are commonly finished with tin plating. Other plating options available. Ideal for mobile military transportation, communication shelters or equipment where EMP or TEMPEST is required.
|
|
|
ATI-Thin Filter is the thinnest profile EMI shielded air filter. Extruded aluminum surrounds a singular thin piece of expanded monel or aluminum metal screen and welded in place. Alco-Knit or conductive gasket increase shielding effectiveness. Through hole locations are customized for easy surface mount installation. Plating options enhance shielding effectiveness. ATI- Thin Filters are frequently placed at intake and exhaust areas and are best utilized where narrow space limitations are a requirement.
|
|
| ... products without technical information |
| |
Transportation fan, directfloated, circulating or being certain cover disk.
Sizes:
VRT 400 - VRT 1,250 (D mm)
Employment:
To the promotion of dust, soot, splinter and fiber parts, to 90°C
Technical data:
V = to 15 m ³ /s
Delta pt = to 6,000 Pa
P = to 75kW
Optionally with Keilriemenantrieb
|
|
|
|
|
|
FD range, air conveying blower
-Blower housings made of abrasion resistant cast iron
-hinged housing cover lid for inspection and cleaning
-welded sheet steel impellers with radial blades
-Maintenance-free squirrel cage rotor motors to IP54
The units can only be supplied in the housing position pictured.
Accessories: Various connectors for both inlet and outlet side.
RD F range
The RD F range can be used for conveying of light and non-abrasive bulk.
The blower parts are made of aluminium cast, the impellers are made of welded sheet steel. The solid construction of the practically maintenance
free medium pressure blowers is the basis for a long lasting service life and low operation cost. Inspection and cleaning may only be carried out at these blowers by unscrewing the housing cover plate. All drive motors are made to IP 54 enclosure, class F thermal insulation and comply with EN 60034-1 (VDE 530 Part 1). The motor power is oversized in order to have sufficient reserve for the conveying.
|
|
The aphonic grid is made from sound-absorbing fins in galvanized steel
V shaped. The grid is supplied with anti-rain profiles and one inner
protection grid. Optionally the grids are available in stainless steel or
aluminum. more frequent using is silencing of air treatment units of
evaporative towers, boiler rooms, etc.
Insulation indexes
AKR 300 = Rw 18
AKR 500 = Rw 21
|
|
-Compact heater
-Heating capacity adjusts to ambient temperature
-Adjustable temperature range
-Temperature safety cut-out
-Clip fixing
-Optical indicator
Semiconductor fan heaters prevent the formation of condensation and ensure an even temperature in switch and control equipment.
The built-in regulator is used to set the desired temperature.
Approvals: UL File Nr. E 204590
|
|
Technical details
- Protection class I - protection type IP 20
- Fan features:
- constant
-Mounting position: Air outlet, top or side
- Connection:
Connecting terminal 0,08-2,5mm²
- Fastening:
Snap fitting DIN rail
- Off blow temerature: 120°C
- Case temperature: 45°C
|
|
FV-40BD1H
Thermo Ventilator - PTC Type ( FV-40BD1H )
PTC heater
Integrated muti-functional ventilator
'Alleru-buster filter' equipped
Heater capacity = 2400W
Air volume = 160 m3/h (venitaltion)
FV-40BD1R
Thermo Ventilator - PTC Type ( FV-40BD1R )
PTC heater
Integrated muti-functional ventilator
'Alleru-buster filter' equipped
Heater capacity = 1400W
Air volume = 160 m3/h (ventialtion)
FV-40BD1W
Thermo Ventilator - PTC Type ( FV-40BD1W )
PTC heater
Integrated muti-functional ventilator
'Alleru-buster filter' equipped
Heater capacity = 2400W
Air volume = 160 m3/h (venitaltion)
|
|
|
Canon Precision's fan motors, with energy saving designs incorporated, are some of the quietest in the industry. The improved bearing design achieves longer operating life than predecessors, and allows operation at higher temperature ranges. High airflow variants are also available.
|
|
|
|
|
|
Fan Driver/Electric Oil Cooler Control
Fan Driver Overview
Kar-Tech's Fan Driver/Electric Oil Cooler Control is a low-cost, highly intelligent control module for controlling electric DC fans or oil coolers for use in mobile hydraulic applications. The Fan Driver can drive a single fan in both directions with sustained supply current of 10 amps (up to 30 amp optional). An onboard temperature input accepts a sensor or switch for fan on temperature (programmable with a sensor input), and by using programmable ramp up and ramp down times, shock on the motor and mounting flanges is reduced or eliminated.
At A Glance:
- Powerful: Sustained 10 or 30 amp supply current in either fan forward or reverse in a 4"x3" package.
- Intelligent: Forward and reverse directions with ramp up and down
- Built To Last: Epoxy-potted "hockey puck" enclosure eliminates the issues in a mobile environment
- User Programmable: Onboard potentiometer-based programming, or use Kar-Tech's Palm Pilot interface
Basic Technical Info:
The Fan Driver operates between a range of +9 to 35VDC, and is protected for voltage spikes and reverse battery. It can provide up to 2 outputs capable of supplying 10 amps per, with a 30 amp option. It is supplied in a 4.2"x3.07"x1.4" enclsoure which is fully encapsulated; 5 16ga. loomed GXL wires provide connections.
Typical Applications:
- Electric DC fans
- DC Motor control
|
|
Switches and controllers
with integrated motor protection
switches: 1-, 2-, 3-step
Control unit:
transformer
5-step and stepless, electronic stepless
Regulated by:
stepless, temperature-, pressure-, humidity-, air velocity
Electronic Control Units
Electronic control units for stepless speed control of voltage-controlled 1- or 3-phase fans. The devices are available in various ratings and formats. Rosenberg offers electronic control units with manual speed selection as well as devices for simple control applications (temperature-pressure control).
|
|
| ... products without technical information |
| |
AIR-1-HT
Independent filter fan units designed for large Sterile Rooms and/or Laminated Airflow Systems, where the levels of cleanliness, noise and absorption are extremely strict.
The AIR-1-HT series Filter Fan Units offer cutting edge technology for modern Sterile Rooms.
Appliances:
Sterile Rooms and Laminar Airflow Systems for the Microelectronic, Electronic, Optical, Mechanical, Aerospace, Pharmaceutical, Medical industries and Hospitals.
|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
|
|