|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
... see all the products in the category
UPSs
|
FemtoPower1060-x-s are passively mode-locked 300 fs fibre lasers operating in the 1060 nm spectral range and delivering up to 5 W of average power.
The lasers consist of a master source, high power fibre amplifier and optical pulse compressor. The lasers are air-cooled, maintenance free and do not require any adjustments.
APPLICATIONS
Fundamental study
Micromachining
Bio-medical
Metrology
|
|
|
The Model 1005 amplifies and conditions the contact closure or digital pulse signal from the Niagara flowmeters and converts it to a powered 4-20 mA output. The 4-20 mA signal is proportional to flow rate and can be used to interface with chart recorders, computers, or other instrumentation. The Model 1005 is factory calibrated with 4 mAs set at zero flow and 20 mAs set at the customer specified flow rate.
|
|
For over 35 years, LDS Nicolet has provided state-of-the-art data acquisition solutions for the test and measurement community. Today, we are the world's premier provider of out-of-the-box, ready to use systems for a diversity of physical and electrical applications. The Genesis system builds on a reputation of high performance acquisition and signal conditioning by providing a flexible, cost effective platform to meet all data acquisition and transient acquisition needs. With the Genesis, LDS Nicolet introduces the future of data acquisition.
Based on the concept of a mainframe with plug-in modules, the Genesis offers a wealth of capabilities. Up to 128 channels can be installed within a rack mainframe (56 channels in the portable tower mainframe), and multiple mainframes can be combined to an even larger system. Up to 400 MegaSample memory per board allows for high definition transient capture. Built-in data transfer acceleration gives you an overview of MegaSamples of data within seconds. With the world's best performance signal conditioning and 16-bit accuracy, Genesis is the right solution for your difficult measurement task.
Genesis Features
Combines Transient Recorder and Streaming Data Acquisition Capabilities
Programmable High-Performance Signal Conditioning
Sample Rates from
200 kS/s to 100 MS/s per Channel
Transient RAM to 400 MS per card, 12.8 GB per System Max.
Tower Mainframe with 7 slots or Rack Version with 16 slots (see lower picture)
Master Slave Option for Synchronized Acquisition on up to 1080 Channels
Unlimited Recording Size and Duration
IRIG and GPS Time Code Options
Local SCSI Drive Storage for Safety Critical Applications
|
|
PRODUCT RANGE GENERAL PRESENTATION
The electronic allows the vibration of the viscometer and processes the amplitude variations in order to deliver a linear viscosity response.
7000 RANGE
• Viscosity and temperature transmitter
• Maximal process temperature 100°C
• Mounting on standard DIN rail
• Analog output 4-20 mA
• RS 485 output
800x RANGE
• Viscosity controller
• Maximal process temperature 200°C or 300°C
• Flush-type mounting
• Analog output 4-20 mA
• RS 485 output
• Output relay (switching power 2A - 250VAC)
OPTIONS :
• Viscosity and temperature processor
• Temperature compensation
• additional analog output 4-20 mA
• Viscosity controller (All or nothing, PID)
|
|
In order to keep the NOx measurement in EPA method 7E and 20 in an economic frame, for example for applications like diesel NOx monitoring or automobile NOx monitoring, the conversion of NOx into NO with Nox Converter is the best economical and reliable solution.
The sample gas streams through a catalyst filled cartridge inserted into an oven which is heated up to over 400°C. The catalyst converts the NOx to NO and thus makes the analysis possible with IR analysers.
Gas Converter BÜNOx
Gas converter NO2 -> NO
High conversion rate at low temperature
Long lifetime
No cross-sensitivity on CO and H2O
Microcontroller
|
|
|
|