MARINE-APPROVED FIRE ALARM CONTROL SYTEMS
All MaviGard Marine Products are Lloyd certified.
They can be used in all sea vehicles.
Conventional System Features System Features
8, 16, 32 or 64 zone capacity
Microprocessor-controlled
Protection from electromagnetic interference
Stable sensitivity of detectors
Twin fire alarm indicators for 360° viewing
2 sounder outputs, 1 fire relay, 1 fault relay
Microprocessor-controlled switched mode power supply
Clamp terminals on detector bases to ensure firm contact
Analogue Addressable System Features
1, 2, 4 or 8 loops.
Up to 1016 x 32 address capacity.
Up to 64 programmable zones.
Microprocessor controlled design.
1000 event log memory.
Programmable and supervised sounder outputs.
Analogue value display measured by detectors.
PCBs are protected by metal case.
Protection from electromagnetic interference
Communication interrupt for fast fire alarm identification in 1.5 sec.
Loop polling in 7.5 seconds.
LCD with backlight.
Cause-effect programming.
|
|
|
When automatic 24/7 fire protection is required, select from our complete line of AUTOPULSE® detection, control and fire suppression system release panels. Detection options include smoke, heat and flame detection. Also consider our VESDA® aspirating smoke detection technology.
|
|
HAREZMIC SERIES INTELLIGENT ANALOGUE ADDRESSABLE SYSTEM ACCESSORIES
VIP (Very Intelligent Protocol) compatible.SSPB (Russia) and GOST R certified.
Approved by Kazakhstan, Oman, UAE, and Bahrain Civil Defence authorities.
Microprocessor-controlled
"Sof" addressable by use of Address Programmer
Easily programable by use of Loop Manager
Able to integrate into the cause-effect scenarios.
LED-indicated activation
Monitoring analogue value
Mesuring contamination level
Aesthetic design
Production by surface-mount technology
|
|
MG-9000 SERIES INTELLIGENT ANALOGUE ADDRESSABLE FIRE DETECTORS
VIP (Very Intelligent Protocol) compatible. EN 54, EMC-CE and SSPB (Russia) and GOST R certified. Approved by Kazakhstan, Oman, UAE and Bahrain Civil Defence authorities.
Features
EN 54-5 ve EN 54-7 certified
Twin fire alarm indicators for 360° viewing
Soft addressable by use of Address Programmer
Remote indicator output
Communication interrupt for fast fire
alarm detection in 3 sec
Stable sensitivity
PCB protected by metal case
Protection from electromagnetic interference
MG-3510 Addressable Mounting Base compatible
MG-3600 Recessed Mounting Base compatible
Microprocessor-controlled
Clamp terminals to ensure firm contact with the base
Produced by use of Surface Mount Technology
|
|
|
|
|
|
MG/MGR-2000 SERIES CONVENTIONAL FIRE DETECTORS
Designed and produced according to EN 54 by use of Surface Mount Technology
providing stable sensitivity. EN 54, EMC-CE and SSPB (Russia) and GOST R certified.Approved by Kazakhstan, Oman, UAE and Bahrain Civil Defence authorities...
Superior design and excellent functional features of the MaviGard detectors are the result of the Research & Development work done using latest technological achievements in the fire alarm industry. Detectors are produced with Surface Mount Technology (SMT). Detector PCB is protected against electromagnetic interference and corrosion by minimizing contact with external medium. MG series detectors are compatible with all fire alarm control panels,
MGR series detectors are compatible with all security alarm control panels. All detectors are provided with blue plastic cover, which protects detector from dust, dirt etc. during construction and paint. Detectors are produced in white as standard but, according to customer's choice, various colours are available. Detectors can be provided with magnet-testing feature on customer's demand.
Features
* Stable sensitivity
* Microprocessor-controlled
* MGR models with relay output
* Twin fire alarm indicators for 360°
viewing
* PCB protected by metal case
* Protection from electromagnetic
interference
* Clamps terminals to ensure firm
contact with the base
* MG-3500 Universal Mounting Base
compatible
* MG-3600 Recessed Mounting Base
compatible
* Remote indicator output
* In MGR series normally close relay
output as standard (normally openalso available)
|
|
|
|
|
|
MAVIGARD MG-104 SERIES CONVENTIONAL EXTINGUISHANT CONTROL PANEL
MG-104 Series operates on cross-zone principle, has 4 detection zones and one
extinguishant release output which can be programmed according to site
needs. SSPB (Russia) and GOST R certified. Approved by Kazakhstan and Oman Civil Defence authorities.
Highlights
* 4 zones, 1 extinguishant release output
* Configurable latching/non-latching zones
* Configurable detection of short circuit as fire alarm
* Distinguished detector/MCP alarm detection
* Programmable 1st Stage sounder output delay
* Programmable extinguishant release duration
* Extinguishant release countdown timer
* Manual and Automatic/Manual extinguishant modes
* 1st and 2nd Stage relay outputs
* Solenoid valve and actuator compatible
* Remote control
* 6 programmable relay outputs
Features
Soft-touch buttons
Microprocessor-controlled
PCBs made by use of Surface Mount Technology
3 programmable and supervised sounder outputs
Compatible with all popular conventional fire detectors
Protection against electromagnetic interference
Optional repeater panels
Optional relay modules
Auxiliary power supply output
Display and LED test by use of single button
Built-in silencable buzzer
|
|
The Insure Flow, Residential Alarmed Backflow System
Residential fire sprinkler systems are designed to save lives, but even the best systems won't work with closed backflow valves.
General Air Products has developed the Insure Flow, a new and innovative solution to the potentially devastating problem caused by an unsupervised closure of a backflow control valve.
Every unit is pre-assembled for fast installation and alarmed for valve closure and system flow.
|
|
HCP-1008E, 8-Zone Expandable Fire Alarm Control Panel
STANDARD FEATURES
8 Class B (Style B) Initiating Circuits which may be configured as 4 Class A (Style D) Circuits. Expandable up to 24 Class B or 12 Class A Initiating Circuits.
4 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.7 Amps max. per circuit)
Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audible may be configured as Steady, Temporal Code, California Code or March Time.
Each Initiating Circuit can be configured as Alarm, Supervisory, Waterflow or Trouble
Two outputs for 4 wire resetable smoke power supply (200 mA max. each)
Alarm verification on Initiating Circuits
Easy configuration via push buttons and SLIDE switches on the front panel
|
|
|
Selecting the right industrial fire alarm signal involves more than calculating decibel levels or choosing one light source over another . It involves ensuring that a signal can operate properly and effectively in the environment in which it will be used.
|
|
|
|
|
|
FN-LCD-N (9th Edition), LCD Network Annunciator,
STANDARD FEATURES
Dual RS-485 ports for primary fire network
RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 16 FN-4127-IO boards
2 built-in RS-232 interfaces for programming via a PC and serial printer interface
4 on board programmable Form C relays rated at 1 Amp at 30VDC (Fire, Supervisory, Trouble & Auxiliary)
Same controls as the FireNET fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
Local piezo sounder for event notification
Supports user codes & firefighter key to enable access & controls
Powered by FireNET Aux 24VDC or UL fire listed Aux. 24VDC supply
Available in red or charcoal, and can be surface or flush mounted (using trim ring)
True network annunciator, any or all panels can be routed to the FN-LCD-N. In addition, each event category can be individually routed to the FN-LCD-N
Up to 64 FireNET panels & FN-LCD-N's can be networked together in any combination
500mA of auxiliary power available rated at 24VDC
Auto-learn feature
Built-in help & alarm information screens
Fire Drill function
Each FN-LCD-N is completely independent
Supports up to 32 FN-4127-IO boards on RS485 expansion port
The FN-LCD-N can be configured to remote reset, silence, resound, any or all panels on the network in any combination
|
|
Functions and display
- Alarm Indicator
The indicator shows, which time/tempera-ture conditions have been violated. The first violated condition is shown in the first column. All further violated conditions will be shown in the second column.
- Time Conditions
The transportation time, programmed between 1 to 48 days according to customer requirements, is subdivided into 24 time segments.
Example:
one time segment: 6 hours
total transportation time: 6 days
- Alarm Time Indicator
The arrow together with the word ALARM shows when the alarm conditions have been violated. (in which time segment after the start)
- Measurement Zones
The time/temperature parameters can be programmed according to customer requirements. (cumulative or single event)
Example:
21°C Alarm after 72h
>34°C Alarm after 2h
|
|
TS 85 R siren autoprotetta, autoalimentata, for outside. Flash built-in HALOGEN. Double container in steel, treaty with cataphoresis, color red.
TECHNICAL CHARACTERISTICS
Feeding: 24 Vcc.
Absorption in quiet 3 but, alarm 1,8 To.
Vain battery: n. 2 from 1,2 Ah 12 V, connected in series.
Dimensions 280x235x95 milimeter
|
|
|
|
|
|
MAXLOGIC MG-16160 INTELLIGENT ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANELS
The latest Maxlogic Analogue Addressable Fire Alarm Control Panel operates on
unique VIP communication protocol which is combatible to use with all MaviGard
Harezmic products. An easy way to use in large sites up to 16 loops and 2032
addresses.
FEATURES
EN54-2 and EN54-4
Compatible with MaviGard Harezmic Series addressable devices.
Up to 64 panels and/or repeater panels can be assembled into a network
LCD (240 x 64 characters) with blue backlight
1000 event log memory
1000 user-defined zones
Extendable loops up to 16 loops, max. 2032 address capasity
Detailed fire alarm and fault warnings
Top priority of fire alarm indication,
different buttons for fire and other events,
caterogical classification due to events.
Real time clock
Communication interrupt for fast fire alarm detection in 1.5 sec
Loop polling in 7.5 sec
4 programmable supervised remote control inputs
Models with printer available
Protection from electromagnetic interference
Communiation with RS232/RS485,GPRS/TCP-IP
Microprocessor-controlled design
Supervised peripheral devices, extension cards (power supply, loop extensions,
printer...)
Day and Night mode, pre-alarm, contamination warning
Virtual panel, supervisor applications
Input/output modules can be connected to panel directly
Advanced control/monitoring features
Creating cause-effect scenarios due to device or zones
By the help of Boot Loader software
updating software on the site
Event selection for input/output devices
Advanced parametric arrangement options for input/output devices
Creating user-defined event type
|
|
HAREZMIC MG-7100 SINGLE LOOP INTELLIGENT ANALOGUE ADDRESSABLE
FIRE ALARM CONTROL PANEL
Single loop structure, stylish exterior design and enhanced programmability make the MG-7100 an economical and technologically top-level solution for small and medium sites. EN 54 and SSPB (Russia) and GOST R certified. Approved by Kazakhstan, Oman, UAE, and Bahrain Civil Defence authorities.
Features
Very Intelligent Communication Protocol
Display priority to fire events
Polling interrupt for fast alarm detection
64 x 240 pixel LCD with adjustable blue backlight
Password-protected access levels
Printer output
Displaying detector measurements
Real-time clock
1000 event log memory
Microprocessor-controlled
PCBs made by use of Surface Mount Technology
2 programmable and supervised sounder outputs
3 programmable relay outputs
16 user-defined zones
Loop polling in 7.5 sec
Protection against electromagnetic interference
Auxiliary power supply output
Soft-touch buttons
Built-in silenceable buzzer
|
|
CONVENTIONAL FIRE ALARM CONTROL PANELS
MODELS:
MP-8 Series
MG-8 Series
MS-64 Series
SD64+ Series
FEATURES:
Highlights
2, 4, 8, 16, 32, 64 zone models(differs due to panel models)
Zonal Fire and Fault LED indicators
Button control key
Zone Test and Zone Disable modes
Zone location text on front panel
Soft-touch buttons
Microprocessor-controlled
PCBs made by use of Surface Mount
Technology
Supervised Sounder outputs
Supervised Relay outputs
Compatible with all popular conventional fire detectors
Protection against electromagnetic interference
Optional repeater panels
Optional relay modules
Auxiliary power supply output
LED test by use of single button
For more information email us
|
|
General Information
4 loop analogue addressable fire panel utilisting soft addressing technology and incorporating a highly versatile touch screen user interface.
Supplied with extended autonomy battery and integral printer
Touch screen user interface
Integral battery and power supply
Integral printer
Optional hinged lockable cover
Wide range of compatible interfaces
Specification
Brand: Menvier
Dimensions (mm): L495 X D200 x H400
Weight (KG): 27
Cable Entry: Top or rear
IP Rating: IP20
No. of Loops: 4
Standby Period: Dependant on system loading
|
|
|
|
|
|
FireNET (9th Edition)
Analog Addressable Fire Alarm Control Panel
STANDARD FEATURES
UL 864 9th edition approved
Analog design using Hochiki's advanced DCP protocol for fast and robust communication
Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
Uses standard wire, no shielded or twisted pair required on SLC loops
Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
4 on board Class B (style Y) NAC circuits rated at 2.5 Amp each
Programmable sensitivity levels per device & automatic day/night sensitivity modes
Automatic daily calibration & drift compensation routine
Large 8-line x 40-character LCD display (320 char.)
2 or 4 loop versions (800 addresses/sub-addr. max.)
Dual RS-485 bus for panel network
2 built-in RS-232 interfaces for programming via a PC and serial printer interface
5 on board programmable Form C relays rated at 1 amp at 30VDC (Fire1, Fire2, trouble, supervisory, aux.)
500mA of auxiliary power available rated at 24 VDC
Loop Explorer Windows® configuration utility
*500 network wide software zones
Network Capability of up to 64 panels
RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 16 FN-4127-IO boards
Auto-learn feature
Built in help and alarm information screens
Fire Drill test function
Walk Test function
Alarm Verification feature
FireNET is UL listed for Central Station Service when used with the Bosch D9068 contact dialer
Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including: *Cause & Effect action, *Disable function configuration, *Test mode configuration
|
|
General Information
2 loop analogue addressable fire control panel to operate with JSB analogue detectors
Up to 198 addresses per loop
Compact enclosure
16 LED zonal indicators
Specification
Brand: JSB
Dimensions (mm): L330 x D90 x H270
Weight (KG): 5.4
ANA Number: 5021621242384
Cable Entry: Top or rear
IP Rating: IP20
No. of Loops: 2
Standby Period: User specified
|
|
| ... products without technical information |
| |
The GammaRAE II-R is two instruments in one: it has the rapid response of a detector and the accurate dose measurement of a dosimeter. It is designed specifically to meet the needs of first responders.
This instrument contains two separate sensors. The Cesium Iodide (CsI) scintillator provides a fast, two-second response to radiological threats, while the energy-compensated PIN diode provides high dose rate range coverage and accurate dose measurements.
The GammaRAE II-R accumulates accurate total dose. Stored dosage data can be cumulative or reset for each use period. It alerts the wearer with a loud audible alarm, big, bright flashing LEDs, and a built-in vibration alarm. For stealth operations, law enforcement personnel can disable each alarm individually.
Immersible (IP67) design makes for reliable operation in wet environments and easy decontamination. IS certification permits operation in potentially flammable/explosive environments.
|
|
|
|
|
|
|
Ionizing radiation that is associated with radioactivity cannot be directly detected by our senses. Ionization is the process whereby the radiation has sufficient energy to strip electrons away from atoms. The ionization results in the formation of free electrons and an ionized atom that has lost some of its orbital electrons. Examples of ionizing radiation include particles such as alpha and beta particles, and photon radiation such as x-rays and gamma rays. Neutrons and protons can also cause ionizations. Since radiation can be harmful to our health, we need detectors that are capable of sensing the presence and intensity of radiation and convert it into an electrical signal to provide suitable alarm. Geiger-Müller tubes are gas-filled radiation detectors that are useful, cheap and robust. A GM tube basically detects the presence and intensity of radiation (particle frequency, rather than energy). Geiger counters are used to detect radiation (usually gamma and beta radiation, but some models can also detect alpha radiation).Geiger-mueller counters respond to the commonly encountered types of radiation, namely, alpha and beta particles as well as gamma and x-radiation. In general, GM counters cannot determine the type, energy, or vectors of the detected radiation. Generally they are used for detecting and measuring radioactivity that consists of low level beta particles and gamma-ray radiation. It has high sensitivity, versatility with various types of radiation, wide variety of shapes and windows, large output signal and reasonable cost.
|
|
| ... products without technical information |
| |
Public Address & General Alarm System ― PA/GA
Guardian Telecom partners with engineering companies, integrators, resellers and end-users to design, implement and commission small to full-blown system configurations. On-site sound surveys and computer assisted sound modeling are some of the Guardian services available to help you achieve maximum results for PA system sound coverage.
Specific client feature base and operation procedures can be customized into Guardian PA/GA systems instead of limited off-the-shelf designs. High quality components for system longevity are paramount and features such as redundant system capability make implemented Guardian PA/GA systems that much safer - for longer.
Visit the Guardian Telecom website www.guardiantelecom.com for more information on Guardian’s PAGA models as well as the full line of Industrial Communication Telephones and services.
|
|
|
|
|
|
Elemec plus
Digitally Controlled Public Address and General Alarm System
* Up to 19.2kW of audio power per system
* Fully duplicated or single system
* Multiple Hot Standby power amplifiers
* Plug and socket construction for easy maintenance
* Up to 16 fully monitored full featured microphone panels over 3-pair cable
* I.S. ATEX microphone panels to Group IIB/C
* Robust 300W intelligent power amps
* Ultrasonic loudspeaker network monitoring
* System status and fault log monitoring via Ethernet link
* Message storage and replay
* System status and fault log monitoring
* Auxiliary Audio Input e.g. music
* Fibre Optic link to remote amplifiers
* CE Marked
Description:
The Elemec plus is a Digitally Controlled Public Address and Alarm System (PA/GA). Designed principally for life critical installations in the Oil and Gas market, it is also suitable for many industrial communications requirements.
The equipment is specifically and fundamentally designed as failsafe, with extensive system and fault status monitoring for maximum availability at all times.
In addition to General Paging and Emergency Broadcasts, Alarms can be automatically initiated, e.g. from Fire and Gas Alarm and Emergency Shut Down Systems. Alarm tones or pre-recorded digital voice evacuation messages can be broadcast.
GAI-Tronics provides the essential control and monitoring system for the PAGA High Integrity Public Address & Alarm System commonly used on Oil & Gas Platforms, FPSO's, Power Stations & Oil Refineries, Chemical Plants & Industrial Complexes Worldwide where the safety of all personnel is of immense importance.
|
|
The powerful indicator N1500 offers among its universal input and the 2 relay outputs for the monitoring of the threshold values many other functions. The Min.- and Max.-values can be prompted with just a keystroke. Also there is a Hold and a Peak-Hold Function whose readouts can be deleted using either the function key or the digital input. The high tact frequency of 15 measurements/second (5 measurements/second when using linear input, thermocouples or Pt100) allows the N1500 indicator to monitor fast processes. It offers also the possibility to linearise the measurement signal when using non-linear input signals (mV, V, mA).
Features:
- Universal input
- Linearization of mV, V, mA signals
- 2 Relay outputs
- 6 Alarm features
- Voltage output 24 VDC for external 2-wire transmitter
- Memory for MAX and MIN values, hold and peak features
See more information in our shop:
***www.temperature-shop.de***
|
|
Various sizes displays with or without alarm functions.
Different mounting types f.ex wall or panel mounting.
|
|
Electromagnetic Inteference (EMI) causes equipment malfunction in many applications. EMI is an increasingly persistant problem anywhere sensitive electronics equipment is used.
Typical issues associated with EMI are equipment lock-ups, random equipment malfunction, data corruption, software and parametric errors along with many others.
|
|
| ... products without technical information |
| |
|
|