Simtronics is pleased to announce the put on the market of the GD1, a new generation of open path detector.
The GD1 innovates by creating a new standard of toxic gas detection. At the heart of the detector is a tuneable laser diode that eliminates environmental effects from sun, rain, and fog. The laser scans single absorption lines where there is no interference from other gases. This new technology constitutes an important progress with exceptional performances and a extreme reduced maintenance.
Unlike traditional methods for detecting H2S (MOS or EC cell), the GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk. Compared to traditional detectors the GD1 offers:
• Faster detection
• Reduced maintenance
• A life calibration
• Fast acting
The GD1 is also available with a dual output gas configuration, Methane and Hydrogen Sulphide.
Supplied with worldwide hazardous area approvals. Suitable for use in SIL 2 systems.
With its level of detection lower than 5ppm and it is faster response time (T90 < 5 sec) the GD1 is ideal to ensure the personnel safety on petrochemical installations onshore or offshore or for the sites of treatment of waster water.
Furthermore, the GD1 offers real cost savings, using a single transmitter / receiver pair, the detector covers distances of up to 100 metres. Installation and maintenance costs are reduced as fewer devices are needed to cover the same risk as several point detectors.
As with all Simtronics’ products, the GD1 is designed for early detection of hazardous events. It’s built to work safely in extreme areas and withstand the hardest environments onshore and offshore.
|
|
|
The Model S4000CH Intelligent Sensor is a microprocessor- based transmitter designed for use with General Monitors' catalytic bead sensors. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Complies with ANSI/ISA 12.13.01-2000 performance requirements for combustible gas detectors.
|
|
The gas measuring systems for explosive gases and vapors made by J. Dittrich Elektronic determine the concentration of explosive gases and vapors in air in an ambient temperature from -10 to +50° C.
A pellistor or semiconductor sensor detects methane (CH4), hydrogen (H2), propane (C3H8), alcohol and benzine; additional hydrocarbons on request.
The calibration is carried out with the aid of the respective test gas by means of a potentiometer; however, a certain amount of cross-sensitivity of the sensor with regard to the other substances always remains.
Low-cost infrared measuring system for methane
Since the cross-sensitivity of the sensors gives rise to problems when monitoring methane, J. Dittrich Elektronic developed a new infrared measuring system which detects specifically methane quicker, more accurately and at less cost than conventional infrared systems.
|
|
|
The Model S4000C Intelligent Sensor is a microprocessor-based transmitter designed for use with General Monitors' catalytic bead sensors. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Complies with ANSI/ISA 12.13.01-2000 performance requirements for combustible gas detectors.
|
|
MSA provides detectors for continuous monitoring of virtually all hazards of combustible atmospheres, toxic gases, oxygen deficieny and fire using detection methods that best suit your application.
|
|
The effectiveness of SIMTRONICS remote detectors (accuracy, fast response time and high reliability) guarantees the ultimate protection against the risks associated with gases in industrial environments.
The housings are given a special surface treatment to improve their resistance to corrosion (stainless steel or aluminium housings).
The measurement process is based on OXYCOL™ low temperature catalytic oxidation, enabling detection of all combustible gases and gives the detector an extremely long lifetime.
All the explosimeters are equipped with :
• An exclusive system of alarm verification in case of scale overrun,
• A linear response,
• A high stability,
• A very short response time.
The interchangeable and removable cartridges (as well as the support independent from the electronic box) make the remote detector easy to use and maintain.
All commands, configurations and readouts are remotely accessible using the infrared remote controller.
|
|
Gas sensors series 400, 500, 600, 700 and 800
The gas sensors are connected to the
corresponding units. The sensors are suitable
for dusty and dirty environments.
Depending on the version (measuring
principle), they are used to detect inflammable
and explosive or toxic gases. All
sensors of this series feature a 4-20 mA
output signal. The gases and vapours
which can be detected comprise:
methane, propane, butane, hydrogen, acetylene,
ammonia, acetone, alcohol and
fuel vapours, CO, CO2, O2, etc. Please
enquire for calibration for other gases.
|
|
• Increased sensitivity for critical applications
The GD10PE is designed for critical applications involving large volumes of air with high velocity. The kind of applications that require reliable detection of low gas concentrations and a fast response.
Typical critical applications include the monitoring of air intakes for HVAC systems in living quarters or generators, and monitoring for potential gas leakages in areas with high temperatures in gas turbine packages.
The GD10PE is a stable instrument, and with a measuring range of 0 – 20%LEL the sensitivity for the GD10PE is 5 times higher than standard point detectors. GD10PE is designed for installation in air ducts and for mounting through walls and bulkheads in places such as pump rooms.
• Based on SimSource™ IR-source
The patented, silicon-based SimSource™ IR-source has a number of unique features and is insensitive to shock and vibration.
Its long-term performance is stable. SimSource™ has an expected in-service life of 60 years exceeding all current competing technologies, which often have an expected in-service life of only 2 to 4 years. SimSource™ comes with an uncompromising 15 years warranty. SimSource™ does not need to be replaced during its service life.
|
|
Gas and CO leakage has caused thousands of people's death. You can take necessary precaution easily! We include LNG detector, LPG detector and CO detection in our product line. They are perfect for household use, offices, factories, basements, indoor parkings, storage, boiler room, kitchens...
Our detector equipped with power and 2-step LED indicators, which provide clear information about power and alarm. The state-of-the-art sensing element is UL apppreoved, which ensures the reliability of the detector. The various models provide different solutions to protect household from any possible damage which might be caused from gas applications. You can also have AGS-4xx series detecting both CO and LNG for a complete protection.
This product series is CE approved.
|
|
Features:
Rugged, ultra-compact (4.2 x 2.4 x 1.4 in / 10.7 x 6.0 x 3.6 cm) and lightweight (5.6 oz. / 160 g)
Simple one-button operation
Standard datalogger (16 hours) and eventlogger (10 events)
Durable, stainless steel alligator clip
Integral concussion-proof boot for the most rugged environments
Continuous LCD shows simultaneous gas concentrations for H2S,CO, O2, and combustibles (0-100% LEL or 0-5.0% Methane)
Powered by a lithium polymer battery (run-time typically 14 hours;recharge in less than 3 hours)
Provides 95 dB alarm tone and bright wide-angled alarm bars
Equipped with internal vibrating alarm for high noise areas
Backlight: in alarm (auto) and on demand reactivation
Four alarm levels: Instant Low and High Alarm for all gases;TWA (time weighted average) and STEL (short term exposure limit) for H2S, CO; OL (over limit alarm)
Simple automatic calibration procedure
Fully compatible with BW's MicroDock II automatic test and calibration system
Records TWA, STEL and maximum exposures to gas and displays readings on command
User selectable options include: confi dence beep, latching alarm, calibration due date, bump due date, "SAFE" display function, multi-language, span concentration values, combustible sensor measurement selection (0-100%LEL or 0-5.0% v/v methane) and stealth mode
Full function self-test of: sensor, battery, circuitry and audible/visual/vibration alarms
Delivered ready for use with sensors, lithium polymer battey, stainless steel alligator belt clip, calibration hose/cap and instructions
|
|
|
The Model TS4000 Intelligent Toxic Gas Detector continuously monitors toxic gases in the ppm range or oxygen deficiency, delivering highly accurate detection and protection. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs.
|
|
J. Dittrich Elektronic gas measuring systems for toxic gases and vapors determine the concentration of toxic gases and vapors in the air mixture at an ambient temperature of -10 to +50° C.
Specific electrochemical sensors measure ammonia (NH3), chlorine (Cl2), carbon monoxide (CO), oxygen (O2), hydrogen sulphide (H2S), nitrogen dioxide (NO2) and nitrogen monoxide (NO) in the ppm range.
The sensors are calibrated with the help of the respective test gas using a potentiometer; there is no or only negligible cross-sensitivity to other substances.
|
|
MSA provides detectors for continuous monitoring of virtually all hazards of combustible atmospheres, toxic gases, oxygen deficieny and fire using detection methods that best suit your application.
|
|
Gas detection : O2, H2S, NH3, CO, NO, NO2, H2, SO2, Cl2, HCl, HCN…
The modern technologies used offer a high resistance to the humidity and temperature compensation as well as stability over time. In order to meet every requirement, SIMRAD Optronics ICARE proposes two different detection technologies :
• Electrochemical cells enabling a wide detection range and excellent selectivity.
• Semi-conductor cells providing extended detector lifetime.
The interchangeable and removable cartridge along with the wall mounting,
independent from the electronic housing, make this detector particularly simple to use.
• NH3 detection, low temperature
To meet needs of cold chains, a low temperature version enables detection down to -40°C.
|
|
The IGD MKIII flammable gas detector has been in service for many years gaining an enviable reputation for reliability and performance.
Developed originally for the off shore oil and gas industries using IGD's patented pellistor technology the MKIII today finds applications across many industries from drilling platfoms to boiler monitoring and everything in between.
Now ATEX approved the MKIII and available with a range of EEXd controllers, rack cards and 4-20mA output interfaces.
|
|
|
Combining state of the art technology with a rugged explosion-proof housing, the GasPoint II analyzes a wide variety of both toxic and combustible gases to high levels of precision. Engineered to rigorous specifications, the unit is specifically designed to provide enhanced performance and reliability in the most adverse industrial conditions. Once installed, this highly customizable and powerful tool provides around the clock protection identifying hazards and triggering appropriate reactive measures such as ventilation activation.
|
|
Gas detectors E2606 are intended for air quality monitoring - control of combustible gas and oxygen concentration and prevention of gas leaks in confined spaces.
Depending on version the gas detector E2606 uses either advanced metal-oxide semiconductor or an electrochemical gas sensor. Concentration of combustible (methane, butane,hydrogen, etc) gases can be measured.
- Temperature range -20..+50 °C, <90 %RH
- Output relay 230V, 3A
- Supply 230 VAC or 24 VDC
- Diffusion, flow-through and remote sensor versions
- Visual and audible alarms, adjustable output relay
- Linearized analog output 4-20 mA
- RS485 Modbus RTU interface option for direct Fieldbus networking
- Wall-mount
|
|
|
Vulcain Inc., a world leader in gas detection for over three decades, has designed the Vulcain 201T series to meet or exceed safety requirements in a variety of commercial and industrial applications. These transmitters can work in a network mode with our Vulcain 201C or Vulcain 301C controller through their RS-485 link, or can be used in a stand-alone configuration offering 4-20mA and alarm relay outputs.
|
|
|
Dräger's product range covers a wide variety of types: catalytic bead or infra-red IR sensor technology point or open path detection increased safety, intrinsically safe or explosion proof analog 4 to 20 mA, digital HART or RS 485 signal output with or without local display with or without on-board relays low budget or high end equipment Your local representative will gladly help you determine the right product for your application
|
|
Gas detectors E2606 are intended for air quality monitoring - control of combustible gas and oxygen concentration and prevention of gas leaks in confined spaces.
Depending on version the gas detector E2606 uses either advanced metal-oxide semiconductor or an electrochemical gas sensor. Concentration of combustible (methane, butane,hydrogen, etc) can be measured.
- Measuring range 0..5 %vol.
- Temperature range -20..+50 °C
- Output relay 230 VAC, 8A
- Supply 230 VAC or 24 VDC
- Diffusion, flow-through and remote sensor versions
- Visual and audible alarms, adjustable output relay
- Linearized analog output 4-20 mA
- RS485 Modbus RTU interface option for direct Fieldbus networking
- Wall-mount
|
|
|
All combustible and explosive gases are combined under the term "EX". Normally the LEL range (lower explosion level) is measured and in some cases in ppm range - by fixed systems or portable gas monitors.
|
|
The IGD MKIII flammable gas detector has been in service for many years gaining an enviable reputation for reliability and performance.
Developed originally for the off shore oil and gas industries using IGD's patented pellistor technology the MKIII today finds applications across many industries from drilling platfoms to boiler monitoring and everything in between.
Now ATEX approved the MKIII and available with a range of EEXd controllers, rack cards and 4-20mA output interfaces.
|
|
|
Biosystems, LLC, a Bacou-Dalloz® Company, is a leading supplier of gas detectors, respiratory maintenance equipment and monitoring systems, worldwide. Founded in 1981, Biosystems is headquartered in Middletown, Connecticut.
|
|
The Dräger-Tube system is an established method for measuring and detecting contaminants in the soil, water and air. The Dräger-Tube method of measurement is used for investigating soil pollution, for investigating liquid samples, and for air analysis.
More than 500 substances can be detected and measured using the Dräger-Tube system. Typical applications include the monitoring of workplace air, emission measurements, quality control, process control and monitoring of compressed air for breathing apparatus, as well as environmental and hazardous substance detection applications.
|
|
The Tocsin 102 series of gas detectors are designed for cost effective hazardous area gas detection solutions. They incorporate micro processor technology to give a stable 4-20mA process signal output or digital addressable output. The addressable output option allows detectors to be networked on a single cable run giving dramatic reduction in installation costs. Combine with the Tocsin 903 controller for local display and calibration. The in built processor can be used to pre-calibrate the sensor prior to installation. Alternatively calibration can be achieved on site via the Oliver IGD control panel or locally using a handheld PC device or laptop. A range of sensing technologies can be incorporated into the housing to provide the most appropriate detection method.
Available sensor types include
Infra Red
Electrochemical Devices
Gas Detected Include
Flammable Gases
Carbon Dioxide
Carbon Monoxide
Nitric Oxide
Nitrogen Dioxide
Hydrogen Cyanide
Chlorine
Hydrogen Sulphide
Ammonia
Oxygen
Sulphur Dioxide
Hydrogen Chloride
|
|
The LumaSense Photoacoustic Field Gas-Monitor Innova - 1412 is a highly accurate, reliable and stable quantitative gas monitor. Its measurement principle is based on the photoacoustic infra-red detection method. This means that the 1412 can measure almost any gas that absorbs infra-red light.
Appropriate optical filters (up to 5 + water vapor) are installed in the 1412's filter carousel so that it can selectively measure the concentration of up to 5 component gases and water vapor in any air sample. Further, the instrument can compensate for interference between the measured gases, using the unique Cross-compensation feature. The 1412's detection limit is gas-dependent but typically in the 10-² ppm region.
|
|
|
The need to continuously and simultaneously measure the concentration of several gases arises frequently in industrial and community applications. For these kinds of measurements, Dräger offers a complete product line to provide our customers with custom solutions.
|
|
G450 Series - New 4-Gas Detector
Watertight design
The compact and lightweight 4-gas detector continuously measures CO, H2S, O2, and combustibles in ambient air. It's functional and watertight design (IP67) incorporates an impact proof, rubberized housing to meet the toughest requirements of harsh environments.
_____________________________________________________
GfG is a world leader for gas detection and measurement technology. For over 40 years GfG has specialized in designing, developing and producing the safest and most reliable equipment and sensors available.
GfG offers an extensive range of portable monitors and fixed systems. The product range includes sensors, the world´s smallest gas monitors, micro-processor controlled multi-gas detectors and computer aided system solutions. GfG provides diverse solutios for Toxic, Explosive and Oxygen gas detection in air and water.
GfG equipement is used in a variety of applications and industries including automotive, chemical industries, landfills, steel industries, hospitals, mining, public utilities, food processing, research institutes, universities and wherever the protection of life and property is needed.
|
|
For over 40 years GfG has been specializing in the development and manufacturing of systems for the measurement of explosive and toxic gases, oxygen as well as further parameters in air and water used in communities, chemical industry, fire and civil protection, mining, power supply, food processing industry, shipping, steel industry, agriculture and also research institutes and universities.Our range extends from sensors, to the smallest gas measuring device in the world, microprocessor driven multimeter with data storage to computer supported systems.
At GfG measuring instruments and sensors are developed by a highly-qualified team of engineers and scientists. A special focus is the development of sensors with the measuring system of IR-absorption, catalytic combustion and thermal conduction.
|
|
|